{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,6,5]],"date-time":"2026-06-05T04:34:08Z","timestamp":1780634048860,"version":"3.54.1"},"reference-count":19,"publisher":"Springer Science and Business Media LLC","issue":"6","license":[{"start":{"date-parts":[[2026,2,6]],"date-time":"2026-02-06T00:00:00Z","timestamp":1770336000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2026,2,6]],"date-time":"2026-02-06T00:00:00Z","timestamp":1770336000000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Eye"],"published-print":{"date-parts":[[2026,4]]},"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:sec>\n                    <jats:title>Purpose<\/jats:title>\n                    <jats:p>This retrospective, non-randomised, observational cohort study investigated the efficiency of a novel 23G trocar adapter to accelerate silicone oil (SO) injection during endotamponading vitreoretinal surgery.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Subjects<\/jats:title>\n                    <jats:p>\n                      A total of 105 eyes were included consecutively. Only 23G procedures were eligible. Indications for SO injection were retinal detachment, recurrent retinal detachment, or SO exchange in eyes with retinal instability using either the high-flow viscous-fluid-extraction accessory cannula as the 23G trocar sleeve adapter (1362.VFE2, Dutch Ophthalmic Research Centre [DORC], Zuidland, the Netherlands;\n                      <jats:italic>n<\/jats:italic>\n                      <jats:sub>Densiron 68<\/jats:sub>\n                      \u2009=\u200930,\n                      <jats:italic>n<\/jats:italic>\n                      <jats:sub>DORC Silicone 5000<\/jats:sub>\n                      \u2009=\u200930) or the universal polyvinyl chloride (PVC) infusion tube as the standard method (1279.VFI, DORC;\n                      <jats:italic>n<\/jats:italic>\n                      <jats:sub>Densiron 68<\/jats:sub>\n                      \u2009=\u200930,\n                      <jats:italic>n<\/jats:italic>\n                      <jats:sub>DORC Silicone 5000<\/jats:sub>\n                      \u2009=\u200915). Eyes with aphakia, traumatic retinal conditions, or combined surgical procedures were excluded.\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods<\/jats:title>\n                    <jats:p>Pars plana vitrectomy was performed, and after complete fluid\u2013air exchange, SO was injected. The trocar sleeve adapter group was treated with an injection pressure of 2.5\u2009bar and with the trocar valve removed. The standard group was treated with 4\u2009bar pressure and with the valve left in place. The time needed to achieve functionally complete filling of the vitreous cavity with SO was recorded. Safety outcomes included the number of device disconnection events and the occurrence of any major complications.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results<\/jats:title>\n                    <jats:p>\n                      Multiple linear regression analysis showed that the injection duration was significantly affected by SO type (\n                      <jats:italic>\u03b2<\/jats:italic>\n                      \u2009=\u2009342.6, 95% confidence interval [CI]: 270.1\u2013415.1,\n                      <jats:italic>p<\/jats:italic>\n                      \u2009&lt;\u20090.0001), device type (\n                      <jats:italic>\u03b2<\/jats:italic>\n                      \u2009=\u2009190.3, 95% CI: 117.2\u2013263.5,\n                      <jats:italic>p<\/jats:italic>\n                      \u2009&lt;\u20090.0001), and axial length (\n                      <jats:italic>\u03b2<\/jats:italic>\n                      \u2009=\u200940.3, 95% CI: 21.6\u201359.1,\n                      <jats:italic>p<\/jats:italic>\n                      \u2009&lt;\u20090.0001). Application of the 23G trocar sleeve adapter significantly reduced the injection time needed to fill the vitreous cavity with Densiron 68, from 258.9\u2009\u00b1\u200974.7\u2009s (PVC; 95% CI: 231.0\u2013286.8; 241.5\u2009\u00b1\u200978\u2009s [median \u00b1 interquartile range]) to 89.8\u2009\u00b1\u200955.0\u2009s (95% CI: 69.3\u2013110.4; 76.0\u2009\u00b1\u200950.5\u2009s;\n                      <jats:italic>p<\/jats:italic>\n                      \u2009&lt;\u20090.0001, Fisher\u2019s LSD, two-way ANOVA). For DORC Silicone 5000, a time reduction from 773.7\u2009\u00b1\u2009257.7\u2009s (95% CI: 631.0\u2013916.4; 835.0\u2009\u00b1\u2009332.0) to 152.8\u2009\u00b1\u200944.5\u2009s was achieved (95% CI: 136.2\u2013169.4; 153.0\u2009\u00b1\u200966.5;\n                      <jats:italic>p<\/jats:italic>\n                      \u2009&lt;\u20090.0001, Fisher\u2019s LSD, two-way ANOVA). Comparisons of vitreous volume\u2013adjusted injection durations calculated using the VIVEX formula yielded similar results\u00a0(both\n                      <jats:italic>p<\/jats:italic>\n                      &lt; 0.0001). Three disconnection events occurred, and all procedures were completed without major complications.\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusions<\/jats:title>\n                    <jats:p>Although the 23G\u00a0trocar sleeve adapter was developed for SO extraction, it reduced the time required for low- and high-viscosity SO injection by three- and fivefold, respectively. The 23G trocar sleeve adapter thus has the potential to substantially shorten SO injection times in clinical practice, although randomised or crossover study designs will be required for validation.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1038\/s41433-026-04279-6","type":"journal-article","created":{"date-parts":[[2026,2,6]],"date-time":"2026-02-06T08:11:37Z","timestamp":1770365497000},"page":"783-788","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":1,"title":["Trocar sleeve adapter accelerates silicone oil injection in real-world vitreoretinal surgery"],"prefix":"10.1038","volume":"40","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-3587-6382","authenticated-orcid":false,"given":"Philip","family":"Wakili","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-6746-3681","authenticated-orcid":false,"given":"Colya N.","family":"Englisch","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Clemens N.","family":"Rudolph","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Charlotte","family":"Semoulin","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Philipp K.","family":"Roberts","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Clara E.","family":"Englisch","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Marc A.","family":"Macek","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Peter","family":"Szurman","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Karl T.","family":"Boden","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2026,2,6]]},"reference":[{"key":"4279_CR1","doi-asserted-by":"publisher","first-page":"546","DOI":"10.1001\/archopht.1987.01060040116047","volume":"105","author":"A Crisp","year":"1987","unstructured":"Crisp A, de Juan E Jr., Tiedeman J. Effect of silicone oil viscosity on emulsification. Arch Ophthalmol. 1987;105:546\u201350.","journal-title":"Arch Ophthalmol"},{"key":"4279_CR2","doi-asserted-by":"publisher","first-page":"2039","DOI":"10.1097\/IAE.0b013e3182561f98","volume":"32","author":"Y Toklu","year":"2012","unstructured":"Toklu Y, Cakmak HB, Ergun SB, Yorgun MA, Simsek S. Time course of silicone oil emulsification. Retina. 2012;32:2039\u201344.","journal-title":"Retina"},{"key":"4279_CR3","doi-asserted-by":"publisher","first-page":"273","DOI":"10.1136\/bjo.2010.192344","volume":"95","author":"RL Williams","year":"2011","unstructured":"Williams RL, Day MJ, Garvey MJ, Morphis G, Irigoyen C, Wong D, et al. Injectability of silicone oil-based tamponade agents. Br J Ophthalmol. 2011;95:273\u20136.","journal-title":"Br J Ophthalmol"},{"key":"4279_CR4","doi-asserted-by":"publisher","first-page":"1170","DOI":"10.1097\/IAE.0000000000003432","volume":"42","author":"M Hammer","year":"2022","unstructured":"Hammer M, Schickhardt SK, Munro D, Khoramnia R, Scheuerle A, Mayer CS, et al. The novel use of high-flow polyimide cannulas to improve silicone oil injectability in vitreoretinal surgery. Retina. 2022;42:1170\u20135.","journal-title":"Retina"},{"key":"4279_CR5","doi-asserted-by":"publisher","first-page":"905","DOI":"10.1007\/s00347-008-1795-y","volume":"105","author":"T Ach","year":"2008","unstructured":"Ach T, Hoh AE, Amberger R, Dithmar S. Exposure to light during vitreoretinal surgery. II: characteristics of endoilluminators. Ophthalmologe. 2008;105:905\u201310.","journal-title":"Ophthalmologe"},{"key":"4279_CR6","doi-asserted-by":"publisher","first-page":"e742","DOI":"10.1111\/aos.14038","volume":"97","author":"K Yamada","year":"2019","unstructured":"Yamada K, Kaneko H, Tsunekawa T, Shimizu H, Suzumura A, Namba R, et al. Silicone oil-associated retinal light exposure under a surgical microscope. Acta Ophthalmol. 2019;97:e742\u20136.","journal-title":"Acta Ophthalmol"},{"key":"4279_CR7","doi-asserted-by":"publisher","first-page":"e176233","DOI":"10.1001\/jamasurg.2017.6233","volume":"153","author":"CP Childers","year":"2018","unstructured":"Childers CP, Maggard-Gibbons M. Understanding costs of care in the operating room. JAMA Surg. 2018;153:e176233.","journal-title":"JAMA Surg"},{"key":"4279_CR8","doi-asserted-by":"crossref","unstructured":"Wilson DI, Te Water Naude AD. Snead MP Refinements in the use of silicone oil as an intraocular tamponade. Eye 2024;38:1810-5.","DOI":"10.1038\/s41433-024-03027-y"},{"key":"4279_CR9","doi-asserted-by":"publisher","first-page":"1894","DOI":"10.1097\/IAE.0000000000004535","volume":"45","author":"P Wakili","year":"2025","unstructured":"Wakili P, Boden KT, Rudolph CN, Szurman P, Roberts PK, Lorenz AT, et al. Efficiency of an innovative trocar adapter for faster silicone oil injection in vitreoretinal surgery: a comparative laboratory study. Retina. 2025;45:1894\u20139.","journal-title":"Retina"},{"key":"4279_CR10","doi-asserted-by":"crossref","unstructured":"Wakili P, Englisch CN, Szurman P, Englisch CE, Rudolph CN, Perez Guerra N. et al. Performance of a trocar sleeve adapter for faster silicone oil extraction in real-world vitreoretinal surgery. J. Clin. Med. 2025;14:6052.","DOI":"10.3390\/jcm14176052"},{"key":"4279_CR11","doi-asserted-by":"publisher","first-page":"205","DOI":"10.1007\/s40123-023-00838-2","volume":"13","author":"AF Borkenstein","year":"2024","unstructured":"Borkenstein AF, Borkenstein EM, Langenbucher A. VIVEX: a formula for calculating individual vitreous volume: a new approach towards tailored patient dosing regime in intravitreal therapy. Ophthalmol Ther. 2024;13:205\u201319.","journal-title":"Ophthalmol Ther"},{"key":"4279_CR12","doi-asserted-by":"publisher","first-page":"552","DOI":"10.7334\/psicothema2016.383","volume":"4","author":"MJ Blanca","year":"2017","unstructured":"Blanca MJ, Alarcon R, Arnau J, Bono R, Bendayan R. Non-normal data: is ANOVA still a valid option? Psicothema. 2017;4:552\u20137.","journal-title":"Psicothema"},{"key":"4279_CR13","doi-asserted-by":"publisher","first-page":"175","DOI":"10.3758\/BF03193146","volume":"39","author":"F Faul","year":"2007","unstructured":"Faul F, Erdfelder E, Lang AG, Buchner AG. Power 3: a flexible statistical power analysis program for the social, behavioral, and biomedical sciences. Behav Res Methods. 2007;39:175\u201391.","journal-title":"Behav Res Methods"},{"key":"4279_CR14","first-page":"2183","volume":"8","author":"VP Dave","year":"2014","unstructured":"Dave VP, Pathengay A, Schwartz SG, Flynn HW Jr. Endophthalmitis following pars plana vitrectomy: a literature review of incidence, causative organisms, and treatment outcomes. Clin Ophthalmol. 2014;8:2183\u20138.","journal-title":"Clin Ophthalmol"},{"key":"4279_CR15","doi-asserted-by":"publisher","first-page":"779","DOI":"10.1016\/j.oret.2018.01.001","volume":"2","author":"M Bhende","year":"2018","unstructured":"Bhende M, Raman R, Singh N, Jain M, Sharma T, Gopal L, et al. Risk factors for endophthalmitis after pars plana vitrectomies in a tertiary eye institute in India. Ophthalmol Retina. 2018;2:779\u201384.","journal-title":"Ophthalmol Retina"},{"key":"4279_CR16","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1097\/IAE.0b013e318156e015","volume":"28","author":"S Charles","year":"2008","unstructured":"Charles S. Illumination and phototoxicity issues in vitreoretinal surgery. Retina. 2008;28:1\u20134.","journal-title":"Retina"},{"key":"4279_CR17","doi-asserted-by":"publisher","first-page":"189","DOI":"10.1159\/000475760","volume":"58","author":"M Coppola","year":"2017","unstructured":"Coppola M, Cicinelli MV, Rabiolo A, Querques G, Bandello F. Importance of light filters in modern vitreoretinal surgery: an update of the literature. Ophthalmic Res. 2017;58:189\u201393.","journal-title":"Ophthalmic Res"},{"key":"4279_CR18","doi-asserted-by":"publisher","first-page":"1372","DOI":"10.1136\/bjo.84.12.1372","volume":"84","author":"PR van den Biesen","year":"2000","unstructured":"van den Biesen PR, Berenschot T, Verdaasdonk RM, van Weelden H, van Norren D. Endoillumination during vitrectomy and phototoxicity thresholds. Br J Ophthalmol. 2000;84:1372\u20135.","journal-title":"Br J Ophthalmol"},{"key":"4279_CR19","doi-asserted-by":"publisher","first-page":"61","DOI":"10.1016\/j.survophthal.2025.08.011","volume":"71","author":"ML Ruggeri","year":"2026","unstructured":"Ruggeri ML, Romano MR, Rossi T, Bacherini D, Ferrara M, Placentino L, et al. Silicone oil removal-related vision loss. Surv Ophthalmol. 2026;71:61\u201370.","journal-title":"Surv Ophthalmol"}],"container-title":["Eye"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.nature.com\/articles\/s41433-026-04279-6.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.nature.com\/articles\/s41433-026-04279-6","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.nature.com\/articles\/s41433-026-04279-6.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,4,8]],"date-time":"2026-04-08T15:20:21Z","timestamp":1775661621000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.nature.com\/articles\/s41433-026-04279-6"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,2,6]]},"references-count":19,"journal-issue":{"issue":"6","published-print":{"date-parts":[[2026,4]]}},"alternative-id":["4279"],"URL":"https:\/\/doi.org\/10.1038\/s41433-026-04279-6","relation":{},"ISSN":["0950-222X","1476-5454"],"issn-type":[{"value":"0950-222X","type":"print"},{"value":"1476-5454","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,2,6]]},"assertion":[{"value":"20 August 2025","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"13 January 2026","order":2,"name":"revised","label":"Revised","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"27 January 2026","order":3,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"6 February 2026","order":4,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"The authors declare no competing interests.","order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}},{"value":"Informed consent was obtained from all involved patients. The reported study adhered to the tenets of the Declaration of Helsinki and was approved by the local institutional review board (Ethikkommission bei der \u00c4rztekammer des Saarlandes, 243\/14).","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethics statement"}}]}}