{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,26]],"date-time":"2026-08-26T23:44:35Z","timestamp":1787787875584,"version":"build-2784847793"},"reference-count":20,"publisher":"Springer Science and Business Media LLC","issue":"3","license":[{"start":{"date-parts":[[2025,11,5]],"date-time":"2025-11-05T00:00:00Z","timestamp":1762300800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.springernature.com\/gp\/researchers\/text-and-data-mining"},{"start":{"date-parts":[[2025,11,5]],"date-time":"2025-11-05T00:00:00Z","timestamp":1762300800000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/www.springernature.com\/gp\/researchers\/text-and-data-mining"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Hypertens Res"],"published-print":{"date-parts":[[2026,3]]},"DOI":"10.1038\/s41440-025-02410-w","type":"journal-article","created":{"date-parts":[[2025,11,5]],"date-time":"2025-11-05T08:59:24Z","timestamp":1762333164000},"page":"1025-1029","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":7,"title":["The quest for accurate wearable blood pressure monitors"],"prefix":"10.1038","volume":"49","author":[{"given":"George S.","family":"Stergiou","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ariadni","family":"Menti","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Dimitrios","family":"Mariglis","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Anastasios","family":"Kollias","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2025,11,5]]},"reference":[{"key":"2410_CR1","doi-asserted-by":"publisher","first-page":"1293","DOI":"10.1097\/HJH.0000000000002843","volume":"39","author":"GS Stergiou","year":"2021","unstructured":"Stergiou GS, Palatini P, Parati G, O\u2019Brien E, Januszewicz A, Lurbe E, et al. European Society of Hypertension practice guidelines for office and out-of-office blood pressure measurement. J Hypertens. 2021;39:1293\u2013302.","journal-title":"J Hypertens"},{"key":"2410_CR2","doi-asserted-by":"publisher","first-page":"957","DOI":"10.1161\/HYPERTENSIONAHA.125.24822","volume":"82","author":"R Mukkamala","year":"2025","unstructured":"Mukkamala R, Shroff SG, Kyriakoulis KG, Avolio AP, Stergiou GS. Cuffless blood pressure measurement: where do we actually stand?. Hypertension. 2025;82:957\u201370.","journal-title":"Hypertension"},{"key":"2410_CR3","doi-asserted-by":"publisher","first-page":"2074","DOI":"10.1097\/HJH.0000000000003483","volume":"41","author":"GS Stergiou","year":"2023","unstructured":"Stergiou GS, Avolio AP, Palatini P, Kyriakoulis KG, Schutte AE, Mieke S, et al. European Society of Hypertension recommendations for the validation of cuffless blood pressure measuring devices: European Society of Hypertension Working Group on Blood Pressure Monitoring and Cardiovascular Variability. J Hypertens. 2023;41:2074\u201387.","journal-title":"J Hypertens"},{"key":"2410_CR4","unstructured":"IEEE standard for wearable cuffless blood pressure measuring devices. IEEE Std 1708-2014. 2014. pp. 1\u201338. https:\/\/standards.ieee.org\/standard\/1708-2014.html. [Accessed 15 Sep. 2025]."},{"key":"2410_CR5","unstructured":"IEEE standard for wearable, cuffless blood pressure measuring devices - amendment 1. IEEE Std 1708a-2019 (Amendment to IEEE Std 1708-2014). 2019. pp. 1\u201335. https:\/\/standards.ieee.org\/standard\/1708a-2019.html. [Accessed 15 Sep. 2025]."},{"key":"2410_CR6","unstructured":"Non-invasive sphygmomanometers \u2014 Part 3: Clinical investigation of continuous automated measurement type. International Organization for Standardization (ISO) 81060-3. 2022. www.iso.org. [Accessed 15 Sep. 2025]."},{"key":"2410_CR7","doi-asserted-by":"publisher","first-page":"368","DOI":"10.1161\/HYPERTENSIONAHA.117.10237","volume":"71","author":"GS Stergiou","year":"2018","unstructured":"Stergiou GS, Alpert B, Mieke S, Asmar R, Atkins N, Eckert S, et al. A Universal Standard for the validation of blood pressure measuring devices: Association for the Advancement of Medical Instrumentation\/European Society of Hypertension\/International Organization for Standardization (AAMI\/ESH\/ISO) Collaboration Statement. Hypertension. 2018;71:368\u201374.","journal-title":"Hypertension"},{"key":"2410_CR8","unstructured":"Noninvasive sphygmomanometers - Part 2: Clinical investigation of intermittent automated measurement type. International Organization for Standardization (ISO) 81060-2. 2018. www.iso.org. [Accessed 15 Sep. 2025]."},{"key":"2410_CR9","doi-asserted-by":"publisher","first-page":"1874","DOI":"10.1097\/HJH.0000000000003480","volume":"41","author":"G Mancia","year":"2023","unstructured":"Mancia G, Kreutz R, Brunstr\u00f6m M, Burnier M, Grassi G, Januszewicz A, et al. 2023 ESH Guidelines for the management of arterial hypertension The Task Force for the management of arterial hypertension of the European Society of Hypertension. J Hypertens. 2023;41:1874\u20132071.","journal-title":"J Hypertens"},{"key":"2410_CR10","doi-asserted-by":"crossref","unstructured":"McEvoy JW, McCarthy CP, Bruno RM, Brouwers S, Canavan MD, Ceconi C, et al; ESC Scientific Document Group. 2024 ESC Guidelines for the management of elevated blood pressure and hypertension. Eur Heart J. 2024;45:3912\u20134018.","DOI":"10.1093\/ehjcvp\/pvae084"},{"key":"2410_CR11","first-page":"e212","volume":"82","author":"DW Jones","year":"2025","unstructured":"Jones DW, Ferdinand KC, Taler SJ, Johnson HM, Shimbo D, Abdalla M, et al. 2025 AHA\/ACC\/AANP\/AAPA\/ABC\/ACCP\/ACPM\/AGS\/AMA\/ASPC\/NMA\/PCNA\/SGIM guideline for the prevention, detection, evaluation, and management of high blood pressure in adults. A Report of the American College of Cardiology\/American Heart Association Joint Committee on Clinical Practice Guidelines. JACC. 2025;82:e212\u2013e316.","journal-title":"JACC"},{"key":"2410_CR12","unstructured":"Apple debuts Apple Watch Series 11, featuring groundbreaking health insights. Press release, Sep. 9, 2025. https:\/\/www.apple.com\/newsroom\/2025\/09\/apple-debuts-apple-watch-series-11-featuring-groundbreaking-health-insights\/. Accessed 14 Sep. 2025."},{"key":"2410_CR13","unstructured":"Hypertension Notification Feature on Apple Watch. 2025. chrome-extension:\/\/efaidnbmnnnibpcajpcglclefindmkaj\/ https:\/\/www.apple.com\/health\/pdf\/Hypertension_Notifications_Validation_Paper_September_2025.pdf. [Accessed 14 Sep. 2025]."},{"key":"2410_CR14","doi-asserted-by":"publisher","first-page":"853","DOI":"10.1111\/jch.13499","volume":"21","author":"M Kuwabara","year":"2019","unstructured":"Kuwabara M, Harada K, Hishiki Y, Kario K. Validation of two watch-type wearable blood pressure monitors according to the ANSI\/AAMI\/ISO81060-2:2013 guidelines: Omron HEM-6410T-ZM and HEM-6410T-ZL. J Clin Hypertens. 2019;21:853\u20138.","journal-title":"J Clin Hypertens"},{"key":"2410_CR15","first-page":"843","volume":"19","author":"L Yi","year":"2022","unstructured":"Yi L, Lv ZH, Hu SY, Liu YQ, Yan JB, Zhang H, et al. Validating the accuracy of a multifunctional smartwatch sphygmomanometer to monitor blood pressure. J Geriatr Cardiol. 2022;19:843\u201352.","journal-title":"J Geriatr Cardiol"},{"key":"2410_CR16","doi-asserted-by":"publisher","first-page":"353","DOI":"10.1097\/MBP.0000000000000608","volume":"27","author":"W Zhang","year":"2022","unstructured":"Zhang W, Zhou YN, Zhou Y, Wang JG. Validation of the watch-type HUAWEI WATCH D oscillometric wrist blood pressure monitor in adult Chinese. Blood Press Monit. 2022;27:353\u20136.","journal-title":"Blood Press Monit"},{"key":"2410_CR17","doi-asserted-by":"publisher","first-page":"437","DOI":"10.14740\/cr1569","volume":"14","author":"WL Lee","year":"2023","unstructured":"Lee WL, Danaee M, Abdullah A, Wong LP. Is the blood pressure-enabled smartwatch ready to drive precision medicine? supporting findings from a validation study. Cardiol Res. 2023;14:437\u201345.","journal-title":"Cardiol Res"},{"key":"2410_CR18","doi-asserted-by":"publisher","first-page":"793","DOI":"10.1111\/jch.14179","volume":"23","author":"K Kario","year":"2021","unstructured":"Kario K, Tomitani N, Iwashita C, Shiga T, Kanegae H. Simultaneous self-monitoring comparison of a supine algorithm-equipped wrist nocturnal home blood pressure monitoring device with an upper arm device. J Clin Hypertens. 2021;23:793\u2013801.","journal-title":"J Clin Hypertens"},{"key":"2410_CR19","doi-asserted-by":"crossref","unstructured":"Parati G, Pengo MF, Avolio A, Azizi M, Bothe TL, Burnier M, et al; ESH Working Group on Blood Pressure Monitoring and Cardiovascular Variability. Nocturnal blood pressure: pathophysiology, measurement and clinical implications. Position paper of the European Society of Hypertension. J Hypertens. 2025;43:1296\u2013318.","DOI":"10.1097\/HJH.0000000000004053"},{"key":"2410_CR20","doi-asserted-by":"publisher","DOI":"10.1038\/s41440-025-02345-2","author":"Y Zhou","year":"2025","unstructured":"Zhou Y, Zhang W, Wang XY, Zhou Y, Li Y, Wang JG. Accuracy of a wearable watch-type oscillometric blood pressure monitor in rest and ambulatory blood pressure measurements. Hypertens Res. 2025. https:\/\/doi.org\/10.1038\/s41440-025-02345-2.","journal-title":"Hypertens Res"}],"container-title":["Hypertension Research"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.nature.com\/articles\/s41440-025-02410-w.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.nature.com\/articles\/s41440-025-02410-w","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.nature.com\/articles\/s41440-025-02410-w.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,3,4]],"date-time":"2026-03-04T23:02:19Z","timestamp":1772665339000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.nature.com\/articles\/s41440-025-02410-w"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,11,5]]},"references-count":20,"journal-issue":{"issue":"3","published-print":{"date-parts":[[2026,3]]}},"alternative-id":["2410"],"URL":"https:\/\/doi.org\/10.1038\/s41440-025-02410-w","relation":{},"ISSN":["0916-9636","1348-4214"],"issn-type":[{"value":"0916-9636","type":"print"},{"value":"1348-4214","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,11,5]]},"assertion":[{"value":"22 September 2025","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"25 September 2025","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"5 November 2025","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Compliance with ethical standards"}},{"value":"GS conducted clinical development and validation studies for various manufacturers of cuff and cuffless blood pressure measurement technologies and devices and advised manufacturers on device and software development. AM, DM, and AK contributed to clinical development and validation studies for various manufacturers of blood pressure measurement devices with payments made to the Athens University Special Account for Research Grants.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Conflict of interest"}},{"value":"This content has been made available to all.","name":"free","label":"Free to read"}]}}