{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,24]],"date-time":"2026-10-24T02:19:33Z","timestamp":1792808373676,"version":"4.5.0"},"reference-count":57,"publisher":"Springer Science and Business Media LLC","license":[{"start":{"date-parts":[[2025,5,12]],"date-time":"2025-05-12T00:00:00Z","timestamp":1747008000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2025,5,12]],"date-time":"2025-05-12T00:00:00Z","timestamp":1747008000000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Int J Impot Res"],"abstract":"<jats:title>Abstract<\/jats:title>\n          <jats:p>Reservoir placement for the inflatable penile prosthesis has evolved over time with surgical safety and functional outcomes driving innovative changes. This state of the art review describes contemporary placement options for the inflatable penile prosthesis reservoir, including traditional space of Retzius placement and other alternate reservoir placements. The space of Retzius remains a familiar location for virgin placements while submuscular placement has gained popularity for its versatility and lower risk of visceral injury. The lateral retroperitoneal location can be considered for a patient with a hostile pelvis. A comparison of complications and functional outcomes highlights benefits and drawbacks of each location. This review aims to equip the prosthetic urologist with modern techniques and a surgical armamentarium that can address any reservoir placement.<\/jats:p>","DOI":"10.1038\/s41443-025-01082-x","type":"journal-article","created":{"date-parts":[[2025,5,12]],"date-time":"2025-05-12T08:26:14Z","timestamp":1747038374000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":6,"title":["Reservoir placement options: a state of the art review"],"prefix":"10.1038","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-1846-5952","authenticated-orcid":false,"given":"Samuel","family":"Ivan","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jessica","family":"Pryor","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Fenizia","family":"Maffucci","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jay","family":"Simhan","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2025,5,12]]},"reference":[{"key":"1082_CR1","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1038\/s41443-019-0164-5","volume":"32","author":"G Hatzichristodoulou","year":"2020","unstructured":"Hatzichristodoulou G. Surgical therapy as constant future gold standard for penile disorders. Int J Impot Res. 2020;32:1. https:\/\/doi.org\/10.1038\/s41443-019-0164-5.","journal-title":"Int J Impot Res."},{"key":"1082_CR2","doi-asserted-by":"publisher","first-page":"80","DOI":"10.1016\/0090-4295(73)90224-0","volume":"2","author":"FB Scott","year":"1973","unstructured":"Scott FB, Bradley WE, Timm GW. Management of erectile impotence. Use of implantable inflatable prosthesis. Urology. 1973;2:80\u20132.","journal-title":"Urology"},{"key":"1082_CR3","doi-asserted-by":"publisher","first-page":"2774","DOI":"10.1111\/jsm.12311","volume":"10","author":"I Vakalopoulos","year":"2013","unstructured":"Vakalopoulos I, Kampantais S, Ioannidis S, Laskaridis L, Dimopoulos P, Toutziaris C, et al. High patient satisfaction after inflatable penile prostheses implantation correlates with female partner satisfaction. J Sex Med. 2013;10:2774\u201381.","journal-title":"J Sex Med"},{"key":"1082_CR4","doi-asserted-by":"publisher","first-page":"67","DOI":"10.1093\/jsxmed\/qdad154","volume":"21","author":"J Beirnaert","year":"2023","unstructured":"Beirnaert J, Pinar U, Benarroche D, Akakpo W, Roupr\u00eat M. Evaluation of patient satisfaction using the validated French version of the SSIPI questionnaire after inflatable penile implantation. J Sex Med. 2023;21:67\u201371.","journal-title":"J Sex Med"},{"key":"1082_CR5","doi-asserted-by":"publisher","first-page":"564","DOI":"10.1038\/s41443-022-00603-2","volume":"35","author":"J La","year":"2023","unstructured":"La J, Loeb CA, Barham DW, Miller J, Chung E, Gross MS, et al. Satisfaction rates of inflatable penile prosthesis in men who have sex with men are high. Int J Impot Res. 2023;35:564\u20138.","journal-title":"Int J Impot Res"},{"key":"1082_CR6","doi-asserted-by":"crossref","unstructured":"Cinar NB, Saribacak A, Atwater BL, Gross MS, Wilson SK, Culha M. Patient satisfaction study for the new Rigicon Infla10 inflatable penile prosthesis including single surgeon safety and outcomes data. J Sex Med. 2025;22:344\u20138.","DOI":"10.1093\/jsxmed\/qdae168"},{"key":"1082_CR7","doi-asserted-by":"publisher","first-page":"6","DOI":"10.1016\/j.urology.2022.03.026","volume":"166","author":"LE Miller","year":"2022","unstructured":"Miller LE, Khera M, Bhattacharyya S, Patel M, Nitschelm K, Burnett AL. Long-term survival rates of inflatable penile prostheses: systematic review and meta-analysis. Urology. 2022;166:6\u201310.","journal-title":"Urology."},{"key":"1082_CR8","doi-asserted-by":"publisher","first-page":"2599","DOI":"10.1016\/j.juro.2006.08.012","volume":"1761","author":"NB Dhar","year":"2006","unstructured":"Dhar NB, Angermeier KW, Montague DK. Long-term mechanical reliability of AMS 700CX\/CXM inflatable penile prosthesis. J Urol. 2006;1761:2599\u2013601.","journal-title":"J Urol"},{"key":"1082_CR9","doi-asserted-by":"publisher","first-page":"1074","DOI":"10.1111\/j.1743-6109.2007.00540.x","volume":"41","author":"SK Wilson","year":"2007","unstructured":"Wilson SK, Delk JR, Salem EA, Cleves MA. Long-term survival of inflatable penile prostheses: single surgical group experience with 2,384 first-time implants spanning two decades. J Sex Med. 2007;41:1074\u20139.","journal-title":"J Sex Med"},{"key":"1082_CR10","doi-asserted-by":"publisher","first-page":"1475","DOI":"10.1016\/S0022-5347(05)64477-1","volume":"168","author":"SK Wilson","year":"2002","unstructured":"Wilson SK, Henry GD, Delk JR, Cleves MA. The mentor Alpha 1 penile prosthesis with reservoir lock-out valve: effective prevention of auto-inflation with improved capability for ectopic reservoir placement. J Urol. 2002;168:1475\u20138.","journal-title":"J Urol"},{"key":"1082_CR11","doi-asserted-by":"publisher","first-page":"273","DOI":"10.1111\/jsm.12361","volume":"11","author":"G Henry","year":"2014","unstructured":"Henry G, Hsiao W, Karpman E, Bella AJ, Carrion R, Jones L, et al. A guide for inflatable penile prosthesis reservoir placement: pertinent anatomical measurements of the retropubic space. J Sex Med. 2014;11:273\u20138.","journal-title":"J Sex Med"},{"key":"1082_CR12","doi-asserted-by":"publisher","first-page":"2040","DOI":"10.1016\/j.juro.2014.11.095","volume":"193","author":"DT Oberlin","year":"2015","unstructured":"Oberlin DT, Matulewicz RS, Bachrach L, Hofer MD, Brannigan RE, Flury SC. National practice patterns of treatment of erectile dysfunction with penile prosthesis implantation. J Urol. 2015;193:2040\u20134.","journal-title":"J Urol"},{"key":"1082_CR13","doi-asserted-by":"publisher","first-page":"293","DOI":"10.1016\/j.urpr.2017.06.006","volume":"5","author":"TJ Pagliara","year":"2018","unstructured":"Pagliara TJ, Viers BR, Scott J, Morey AF. Extended experience with high submuscular placement of urological prosthetic balloons and reservoirs: refined technique for optimal outcomes. Urol Pract. 2018;5:293\u20138.","journal-title":"Urol Pract"},{"key":"1082_CR14","doi-asserted-by":"publisher","first-page":"2039","DOI":"10.1016\/j.jsxm.2021.09.015","volume":"18","author":"M Kavoussi","year":"2021","unstructured":"Kavoussi M, Cook GS, Nordeck SM, Dropkin BM, Joice GA, Badkhshan S, et al. Radiographic assessment of inflatable penile prosthesis reservoir location variability in contemporary practice. J Sex Med. 2021;18:2039\u201344.","journal-title":"J Sex Med"},{"key":"1082_CR15","first-page":"10946","volume":"28","author":"JN Schardein","year":"2021","unstructured":"Schardein JN, Trussell JC. Reservoir induced bladder rupture: a complication of inflatable penile prosthesis revision surgery. Can J Urol. 2021;28:10946\u201352.","journal-title":"Can J Urol"},{"key":"1082_CR16","doi-asserted-by":"publisher","first-page":"41","DOI":"10.1038\/ijir.2012.31","volume":"25","author":"BB Garber","year":"2013","unstructured":"Garber BB, Morris A. Intravesical penile implant reservoir: case report, literature review, and strategies for prevention. Int J Impot Res. 2013;25:41\u20134.","journal-title":"Int J Impot Res"},{"key":"1082_CR17","doi-asserted-by":"publisher","first-page":"2064","DOI":"10.1111\/j.1743-6109.2009.01277.x","volume":"6","author":"AC Kramer","year":"2009","unstructured":"Kramer AC, Chason J, Kusakabe A. Report of two cases of bladder perforation caused by reservoir of inflatable penile prosthesis. J Sex Med. 2009;6:2064\u20137.","journal-title":"J Sex Med"},{"key":"1082_CR18","doi-asserted-by":"publisher","first-page":"758","DOI":"10.1016\/j.ijscr.2014.06.023","volume":"5","author":"H Abboudi","year":"2014","unstructured":"Abboudi H, Bolgeri M, Nair R, Chetwood A, Symes A, Thomas P. \u201cA reservoir within a reservoir\u201d - An unusual complication associated with a defunctioned inflatable penile prosthesis reservoir. Int J Surg Case Rep. 2014;5:758\u201360.","journal-title":"Int J Surg Case Rep."},{"key":"1082_CR19","doi-asserted-by":"publisher","first-page":"521","DOI":"10.1016\/j.sxmr.2018.12.005","volume":"7","author":"J Clavell-Hern\u00e1ndez","year":"2019","unstructured":"Clavell-Hern\u00e1ndez J, Shah A, Wang R. Non-infectious reservoir-related complications during and after penile prosthesis placement. Sex Med Rev. 2019;7:521\u20139.","journal-title":"Sex Med Rev"},{"key":"1082_CR20","doi-asserted-by":"publisher","first-page":"334","DOI":"10.1002\/sm2.85","volume":"3","author":"T Cui","year":"2015","unstructured":"Cui T, Terlecki R, Mirzazadeh M. Infrequent reservoir-related complications of urologic prosthetics: a case series and literature review. Sex Med. 2015;3:334\u20138.","journal-title":"Sex Med"},{"key":"1082_CR21","first-page":"59","volume":"2","author":"JP Selph","year":"2014","unstructured":"Selph JP, McKim SE, Langston JP, Carson CC. Deep venous thrombosis as a complication of reservoir placement in post-prostatectomy erectile dysfunction and urinary incontinence prosthetic surgery. Sex. Med Rev. 2014;2:59\u201363.","journal-title":"Med Rev"},{"key":"1082_CR22","doi-asserted-by":"publisher","first-page":"462","DOI":"10.1016\/S0090-4295(02)02115-5","volume":"61","author":"DG da Justa","year":"2003","unstructured":"da Justa DG, Bianco FJ, Ogle A, Dhabuwala CB. Deep venous thrombosis due to compression of external iliac vein by the penile prosthesis reservoir. Urology 2003;61:462.","journal-title":"Urology"},{"key":"1082_CR23","doi-asserted-by":"publisher","first-page":"2956","DOI":"10.1111\/j.1743-6109.2008.01012.x","volume":"5","author":"F Deho\u2019","year":"2008","unstructured":"Deho\u2019 F, Henry GD, Marone EM, Sacca\u2019 A, Chiesa R, Rigatti P, et al. Severe vascular complication after implantation of a three\u2010piece inflatable penile prosthesis. J Sex Med. 2008;5:2956\u20139.","journal-title":"J Sex Med"},{"key":"1082_CR24","doi-asserted-by":"publisher","first-page":"1185","DOI":"10.1111\/j.1743-6109.2006.00266.x","volume":"42","author":"D Brison","year":"2007","unstructured":"Brison D, Ilbeigi P, Sadeghi-Nejad H. Reservoir repositioning and successful thrombectomy for deep venous thrombosis secondary to compression of pelvic veins by an inflatable penile prosthesis reservoir. J Sex Med. 2007;42:1185\u20137.","journal-title":"J Sex Med"},{"key":"1082_CR25","doi-asserted-by":"publisher","first-page":"190","DOI":"10.1016\/j.sxmr.2015.10.008","volume":"4","author":"P Perito","year":"2016","unstructured":"Perito P, Wilson S. The history of nontraditional or ectopic placement of reservoirs in prosthetic urology. Sex Med Rev. 2016;4:190\u20133.","journal-title":"Sex Med Rev"},{"key":"1082_CR26","doi-asserted-by":"publisher","first-page":"464","DOI":"10.1111\/jsm.13011","volume":"12","author":"T Hakky","year":"2015","unstructured":"Hakky T, Lentz A, Sadeghi-Nejad H, Khera M. The evolution of the inflatable penile prosthesis reservoir and surgical placement. J Sex Med. 2015;12:464\u20137.","journal-title":"J Sex Med"},{"key":"1082_CR27","doi-asserted-by":"publisher","first-page":"415","DOI":"10.1111\/jsm.13004","volume":"12","author":"AW Pastuszak","year":"2015","unstructured":"Pastuszak AW, Lentz AC, Farooq A, Jones L, Bella AJ. Technological improvements in three-piece inflatable penile prosthesis design over the past 40 years. J Sex Med. 2015;12:415\u201321.","journal-title":"J Sex Med"},{"key":"1082_CR28","doi-asserted-by":"publisher","DOI":"10.1007\/s11934-021-01041-1","volume":"22","author":"M Van Dyke","year":"2021","unstructured":"Van Dyke M, Baumgarten AS, Ortiz N, Hudak SJ, Morey AF. State of the reservoir: current concepts of penile implant reservoir placement and potential complications. Curr Urol Rep. 2021;22:20.","journal-title":"Curr Urol Rep."},{"key":"1082_CR29","doi-asserted-by":"publisher","first-page":"2759","DOI":"10.1111\/j.1743-6109.2012.02807.x","volume":"9","author":"LA Levine","year":"2012","unstructured":"Levine LA, Hoeh MP. Review of penile prosthetic reservoir: complications and presentation of a modified reservoir placement technique. J Sex Med. 2012;9:2759\u201369.","journal-title":"J Sex Med"},{"key":"1082_CR30","doi-asserted-by":"publisher","first-page":"539","DOI":"10.1016\/j.urology.2007.04.009","volume":"70","author":"BR Lane","year":"2007","unstructured":"Lane BR, Abouassaly R, Angermeier KW, Montague DK. Three-piece inflatable penile prostheses can be safely implanted after radical prostatectomy through a transverse scrotal incision. Urology 2007;70:539\u201342.","journal-title":"Urology"},{"key":"1082_CR31","doi-asserted-by":"publisher","first-page":"126","DOI":"10.1038\/s41443-019-0171-6","volume":"32","author":"M Falcone","year":"2020","unstructured":"Falcone M, Pucci L, Garaffa G, Cocci A, Gillo A, Capece M, et al. An outcomes analysis of penile prosthesis implantation following radical cystoprostatectomy and urinary diversion: a multicentric retrospective cohort study. Int J Impot Res. 2020;32:126\u201332.","journal-title":"Int J Impot Res"},{"key":"1082_CR32","doi-asserted-by":"publisher","first-page":"907","DOI":"10.1016\/j.jsxm.2018.01.014","volume":"15","author":"J Loh-Doyle","year":"2018","unstructured":"Loh-Doyle J, Patil MB, Sawkar H, Wayne K, Boyd SD. 3-piece inflatable penile prosthesis placement following radical cystoprostatectomy and urinary diversion: technique and outcomes. J Sex Med. 2018;15:907\u201313.","journal-title":"J Sex Med"},{"key":"1082_CR33","doi-asserted-by":"publisher","first-page":"215","DOI":"10.1038\/ijir.2017.26","volume":"29","author":"MS Gross","year":"2017","unstructured":"Gross MS, Stember DS, Garber BB, Perito PE. A retrospective analysis of risk factors for IPP reservoir entry into the peritoneum after abdominal wall placement. Int J Impot Res. 2017;29:215\u20138.","journal-title":"Int J Impot Res"},{"key":"1082_CR34","doi-asserted-by":"crossref","unstructured":"Atwater B, Krug A, Gross MS, Marty-Roix R, Chapin L, Morey AF. A review of the safety and efficacy of inflatable penile prosthesis ectopic reservoir placement. Sex Med Rev. 2025;13:20\u201332.","DOI":"10.1093\/sxmrev\/qeae067"},{"key":"1082_CR35","doi-asserted-by":"publisher","first-page":"1425","DOI":"10.1016\/j.jsxm.2016.06.012","volume":"13","author":"MJ Ziegelmann","year":"2016","unstructured":"Ziegelmann MJ, Viers BR, Lomas DJ, Westerman ME, Trost LW. Ectopic penile prosthesis reservoir placement: an anatomic cadaver model of the high submuscular technique. J Sex Med. 2016;13:1425\u201331.","journal-title":"J Sex Med"},{"key":"1082_CR36","doi-asserted-by":"publisher","first-page":"603","DOI":"10.1111\/jsm.12000","volume":"10","author":"AF Morey","year":"2013","unstructured":"Morey AF, Cefalu CA, Hudak SJ. High submuscular placement of urologic prosthetic balloons and reservoirs via transscrotal approach. J Sex Med. 2013;10:603\u201310.","journal-title":"J Sex Med"},{"key":"1082_CR37","doi-asserted-by":"publisher","first-page":"457","DOI":"10.1111\/bju.15106","volume":"126","author":"AS Baumgarten","year":"2020","unstructured":"Baumgarten AS, Kavoussi M, VanDyke ME, Ortiz NM, Khouri RK, Ward EE, et al. Avoiding deep pelvic complications using a \u201cFive-Step\u201d technique for high submuscular placement of inflatable penile prosthesis reservoirs. BJU Int. 2020;126:457\u201363.","journal-title":"BJU Int"},{"key":"1082_CR38","doi-asserted-by":"publisher","first-page":"371","DOI":"10.1038\/s41443-020-0269-x","volume":"32","author":"SK Wilson","year":"2020","unstructured":"Wilson SK, Simhan J, Osmonov D. Should occasional implanters learn ectopic placement of IPP reservoirs? Int J Impot Res. 2020;32:371\u20138.","journal-title":"Int J Impot Res"},{"key":"1082_CR39","doi-asserted-by":"publisher","first-page":"239","DOI":"10.1016\/j.juro.2014.07.082","volume":"193","author":"E Karpman","year":"2015","unstructured":"Karpman E, Brant WO, Kansas B, Bella AJ, Jones LA, Eisenhart E, et al. Reservoir alternate surgical implantation technique: preliminary outcomes of initial PROPPER study of low profile or spherical reservoir implantation in submuscular location or traditional prevesical space. J Urol. 2015;193:239\u201344.","journal-title":"J Urol"},{"key":"1082_CR40","doi-asserted-by":"publisher","first-page":"1309","DOI":"10.1016\/j.jsxm.2022.05.143","volume":"19","author":"A Khoei","year":"2022","unstructured":"Khoei A, Racik N, Bansal U, Flores F, Khera M. The low submuscular reservoir placement with transfascial fixation for inflatable penile prostheses. J Sex Med. 2022;19:1309\u201312.","journal-title":"J Sex Med"},{"key":"1082_CR41","doi-asserted-by":"publisher","first-page":"224","DOI":"10.1016\/j.jsxm.2020.10.011","volume":"18","author":"D Yang","year":"2021","unstructured":"Yang D, Heslop D, Houlihan M, Helo S, Ziegelmann M, K\u00f6hler TS. The tubing, hitch and lasso, intussusception anchor (THALIA) technique: a novel approach to fixate the penile implant reservoir. J Sex Med. 2021;18:224\u20139.","journal-title":"J Sex Med"},{"key":"1082_CR42","doi-asserted-by":"publisher","first-page":"205","DOI":"10.1093\/jsxmed\/qdac026","volume":"20","author":"ME VanDyke","year":"2023","unstructured":"VanDyke ME, Kavoussi M, Langford BT, Badkhshan S, Nealon SW, Franzen BP, et al. Increasing role of counterincision for high submuscular penile prosthesis reservoir placement. J Sex Med. 2023;20:205\u20139.","journal-title":"J Sex Med"},{"key":"1082_CR43","doi-asserted-by":"publisher","first-page":"1535","DOI":"10.1016\/j.urology.2014.08.029","volume":"84","author":"PH Chung","year":"2014","unstructured":"Chung PH, Morey AF, Tausch TJ, Simhan J, Scott JF. High submuscular placement of urologic prosthetic balloons and reservoirs: 2-year experience and patient-reported outcomes. Urology 2014;84:1535\u201340.","journal-title":"Urology"},{"key":"1082_CR44","doi-asserted-by":"publisher","first-page":"18","DOI":"10.1038\/s41443-019-0201-4","volume":"32","author":"D Osmonov","year":"2020","unstructured":"Osmonov D, Chomicz A, Tropmann-Frick M, Arndt KM, J\u00fcnemann KP. High-submuscular vs. space of Retzius reservoir placement during implantation of inflatable penile implants. Int J Impot Res. 2020;32:18\u201323.","journal-title":"Int J Impot Res"},{"key":"1082_CR45","doi-asserted-by":"publisher","first-page":"298","DOI":"10.1016\/j.urology.2020.07.039","volume":"145","author":"AS Baumgarten","year":"2020","unstructured":"Baumgarten AS, Kavoussi M, Ortiz NM, Khouri RK, Ward EE, Hudak SJ, et al. High submuscular IPP reservoir placement: the \u201cFive-Step\u201d technique. Urology 2020;145:298.","journal-title":"Urology"},{"key":"1082_CR46","doi-asserted-by":"publisher","first-page":"605","DOI":"10.1111\/jsm.12408","volume":"11","author":"DS Stember","year":"2014","unstructured":"Stember DS, Garber BB, Perito PE. Outcomes of abdominal wall reservoir placement in inflatable penile prosthesis implantation: a safe and efficacious alternative to the space of Retzius. J Sex Med. 2014;11:605\u201312.","journal-title":"J Sex Med"},{"key":"1082_CR47","doi-asserted-by":"publisher","first-page":"210","DOI":"10.1016\/j.jsxm.2019.10.016","volume":"17","author":"D Osmonov","year":"2020","unstructured":"Osmonov D, Christopher AN, Blecher GA, Falcone M, Soave A, Dahlem R, et al. Clinical Recommendations From the European Society for Sexual Medicine Exploring Partner Expectations, Satisfaction in Male and Phalloplasty Cohorts, the Impact of Penile Length, Girth and Implant Type, Reservoir Placement, and the Influence of Comorbidities and Social Circumstances. J Sex Med. 2020;17:210\u201337.","journal-title":"J Sex Med"},{"key":"1082_CR48","doi-asserted-by":"publisher","first-page":"968","DOI":"10.1016\/j.jsxm.2017.05.002","volume":"14","author":"EM Capoccia","year":"2017","unstructured":"Capoccia EM, Phelps JN, Levine LA. Modified inflatable penile prosthesis reservoir placement into space of retzius: comparing outcomes in men with or without prior pelvic surgery. J Sex Med. 2017;14:968\u201373.","journal-title":"J Sex Med"},{"key":"1082_CR49","doi-asserted-by":"publisher","first-page":"581","DOI":"10.1016\/j.juro.2018.10.013","volume":"201","author":"JC Hern\u00e1ndez","year":"2019","unstructured":"Hern\u00e1ndez JC, Trost L, K\u00f6hler T, Ring J, Traweek R, Alom M, et al. Emerging complications following alternative reservoir placement during inflatable penile prosthesis placement: a 5-year multi-institutional experience. J Urol. 2019;201:581\u20136.","journal-title":"J Urol"},{"key":"1082_CR50","doi-asserted-by":"publisher","first-page":"2688","DOI":"10.21037\/tau-20-923","volume":"9","author":"D Grimberg","year":"2020","unstructured":"Grimberg D, Wang S, Carlos E, Nos\u00e9 B, Harper S, Lentz AC. Counter incision is a safe and effective method for alternative reservoir placement during inflatable penile prosthesis surgery. Transl Androl Urol. 2020;9:2688\u201396.","journal-title":"Transl Androl Urol"},{"key":"1082_CR51","doi-asserted-by":"publisher","first-page":"279","DOI":"10.1038\/ijir.2010.16","volume":"22","author":"RJ Hartman","year":"2010","unstructured":"Hartman RJ, Helfand BT, McVary KT. Outcomes of lateral retroperitoneal reservoir placement of three-piece penile prosthesis in patients following radical prostatectomy. Int J Impot Res. 2010;22:279\u201383.","journal-title":"Int J Impot Res"},{"key":"1082_CR52","doi-asserted-by":"publisher","first-page":"35","DOI":"10.1016\/j.urology.2021.02.021","volume":"152","author":"JC Loh-Doyle","year":"2021","unstructured":"Loh-Doyle JC, Lin JS, Doumanian LR, Patil MB, Boyd SD. Outcomes of alternative reservoir placement in the lateral retroperitoneum during inflatable penile prosthesis placement. Urology 2021;152:35\u201341.","journal-title":"Urology"},{"key":"1082_CR53","first-page":"3351","volume":"13","author":"MC Smaldone","year":"2006","unstructured":"Smaldone MC, Cannon GM, Benoit RM. Subcutaneous reservoir placement during penile prosthesis implantation. Can J Urol. 2006;13:3351\u20132.","journal-title":"Can J Urol"},{"key":"1082_CR54","doi-asserted-by":"publisher","first-page":"378","DOI":"10.1016\/j.esxm.2020.04.004","volume":"8","author":"I Mykoniatis","year":"2020","unstructured":"Mykoniatis I, Osmonov D, Van Renterghem K. A modified surgical technique for reservoir placement during inflatable penile prosthesis implantation. Sex Med. 2020;8:378\u201382.","journal-title":"Sex Med"},{"key":"1082_CR55","doi-asserted-by":"publisher","first-page":"93","DOI":"10.1016\/j.urology.2015.10.027","volume":"88","author":"BB Garber","year":"2016","unstructured":"Garber BB, Bickell M. Subcutaneous placement of inflatable penile prosthesis reservoirs. Urology. 2016;88:93\u20136.","journal-title":"Urology."},{"key":"1082_CR56","doi-asserted-by":"publisher","first-page":"2115","DOI":"10.1111\/jsm.12203","volume":"10","author":"E Karpman","year":"2013","unstructured":"Karpman E, Sadeghi-Nejad H, Henry G, Khera M, Morey AF. Current opinions on alternative reservoir placement for inflatable penile prosthesis among members of the Sexual Medicine Society of North America. J Sex Med. 2013;10:2115\u201320.","journal-title":"J Sex Med"},{"key":"1082_CR57","first-page":"7465","volume":"21","author":"TJ Tausch","year":"2014","unstructured":"Tausch TJ, Morey AF, Zhao LC, Knoll P, Simhan J, Scott JF, et al. High submuscular versus space of Retzius placement of inflatable penile prosthesis reservoirs: results of a surgeon survey. Can J Urol. 2014;21:7465\u20139.","journal-title":"Can J Urol"}],"container-title":["International Journal of Impotence Research"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.nature.com\/articles\/s41443-025-01082-x.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.nature.com\/articles\/s41443-025-01082-x","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.nature.com\/articles\/s41443-025-01082-x.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,5,12]],"date-time":"2025-05-12T10:04:35Z","timestamp":1747044275000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.nature.com\/articles\/s41443-025-01082-x"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,5,12]]},"references-count":57,"alternative-id":["1082"],"URL":"https:\/\/doi.org\/10.1038\/s41443-025-01082-x","relation":{},"ISSN":["0955-9930","1476-5489"],"issn-type":[{"value":"0955-9930","type":"print"},{"value":"1476-5489","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,5,12]]},"assertion":[{"value":"8 January 2025","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"7 April 2025","order":2,"name":"revised","label":"Revised","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"28 April 2025","order":3,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"12 May 2025","order":4,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"JS is a consultant for Boston Scientific and Coloplast Corporation. SI, JP, and FM declare no competing interests.","order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}},{"value":"This work is a review of publicly available published data and did not collect any novel human subject data making it exempt from formal ethics committee evaluation. Any patient photos are published with informed consent.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethical approval"}}]}}