{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,2,19]],"date-time":"2026-02-19T14:05:51Z","timestamp":1771509951405,"version":"3.50.1"},"reference-count":14,"publisher":"Springer Science and Business Media LLC","license":[{"start":{"date-parts":[[2026,2,16]],"date-time":"2026-02-16T00:00:00Z","timestamp":1771200000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2026,2,16]],"date-time":"2026-02-16T00:00:00Z","timestamp":1771200000000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Int J Impot Res"],"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:p>Suturing the corporotomies over the penile implant yields water-tight closure, reducing the risk of hematoma and subsequent infection, though at the risk of needle puncture of the inflatable cylinders. This prospective randomized controlled study evaluates Shaeer\u2019s Corporotomy Closure Technique (SCCT); a surgical technique to enhance the ease and safety of suturing the corporotomies closed, by everting the corporotomy edges. The study was performed in a single center, between 2022 and 2025, in Cairo, Egypt. Three-piece inflatable penile prosthesis (iPP) implantation was performed for 32 patients with erectile dysfunction refractory to medical treatment, excluding cases of previous penile surgery, Peyronie\u2019s disease, corporal fibrosis or radical prostatectomy, or those receiving anticoagulant therapy. Patients were randomized into two groups. The Control Group had the corporotomies closed by tying the pre-placed stay sutures. SCCT Group had the corporotomies sutured closed with the edges everted using horizontal mattress sutures placed on each side of the intended corporotomy, two on each corpus cavernosum. After corporotomy, the stay sutures were tied, everting the edges. The everted corporotomy edges were then sutured closed in a running fashion. Operative time was 9.5% (5\u2009min) shorter in the Control Group (47.7\u2009\u00b1\u20095.3\u2009mins vs. 52.7\u2009\u00b1\u20094.4\u2009mins, p\u2009=\u20090.009). Drain output at 24\u2009h was 78.8% (59.4 cc\u2019s) higher for Control Group (75.4\u2009\u00b1\u200932.8 cc\u2019s vs. 16\u2009\u00b1\u20098.6 cc\u2019s, p\u2009&lt;\u20090.001), (Table\u00a01, Fig.\u00a05). Total drain output was 81.5% (77.5 cc\u2019s) higher in Control Group (95.1\u2009\u00b1\u200964.8 cc\u2019s vs. 17.6\u2009\u00b1\u200912 cc\u2019s, p\u2009&lt;\u20090.001). For both groups, no intra-operative complications, infections or device mechanical failures were recorded through the follow up period; 14 months\u2009\u00b1\u20094.4. One case in Control Group developed a scrotal hematoma, and two cases developed scrotal tissue induration surrounding the pump, delaying deflation and cycling. SCCT allows safer suturing of the corporotomies.<\/jats:p>","DOI":"10.1038\/s41443-026-01225-8","type":"journal-article","created":{"date-parts":[[2026,2,16]],"date-time":"2026-02-16T11:19:02Z","timestamp":1771240742000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":0,"title":["Shaeer\u2019s corporotomy closure technique for safer suturing of the corpora: a randomized controlled study"],"prefix":"10.1038","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-3811-9969","authenticated-orcid":false,"given":"Osama","family":"Shaeer","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"suffix":"Jr.","given":"Kamal O.K.M.","family":"Shaeer","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Kamal","family":"Shaeer","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2026,2,16]]},"reference":[{"key":"1225_CR1","doi-asserted-by":"publisher","first-page":"924","DOI":"10.1016\/S0022-5347(17)35650-1","volume":"150","author":"DK Montague","year":"1993","unstructured":"Montague DK. Penile prosthesis corporotomy closure: a new technique. J Urol. 1993;150:924\u20135.","journal-title":"J Urol"},{"key":"1225_CR2","doi-asserted-by":"publisher","first-page":"S832","DOI":"10.21037\/tau.2017.06.07","volume":"6","author":"TK O\u2019Rourke Jr","year":"2017","unstructured":"O\u2019Rourke TK Jr, Erbella A, Zhang Y, Wosnitzer MS. Prevention, identification, and management of post-operative penile implant complications of infection, hematoma, and device malfunction. Transl Androl Urol. 2017;6:S832\u2013s48.","journal-title":"Transl Androl Urol"},{"key":"1225_CR3","doi-asserted-by":"publisher","first-page":"1187","DOI":"10.1016\/j.juro.2011.07.042","volume":"186","author":"TS Kohler","year":"2011","unstructured":"Kohler TS, Hellstrom WJ. Using wound drains for the uncomplicated penile prosthesis. J Urol. 2011;186:1187\u20139.","journal-title":"J Urol"},{"key":"1225_CR4","doi-asserted-by":"publisher","first-page":"722","DOI":"10.1089\/sur.2017.089","volume":"18","author":"H Cheng","year":"2017","unstructured":"Cheng H, Chen BP, Soleas IM, Ferko NC, Cameron CG, Hinoul P. Prolonged operative duration increases risk of surgical site infections: a systematic review. Surg Infect. 2017;18:722\u201335.","journal-title":"Surg Infect"},{"key":"1225_CR5","doi-asserted-by":"publisher","first-page":"87","DOI":"10.1038\/s41443-023-00710-8","volume":"37","author":"D Osmonov","year":"2025","unstructured":"Osmonov D, Ragheb AM, Petry T, Eraky A, Bettocchi C, Lamers KG, et al. Value of prolonged scrotal drainage after penile prosthesis implantation: a multicenter prospective nonrandomized pilot study. Int J Impot Res. 2025;37:87\u201391.","journal-title":"Int J Impot Res"},{"key":"1225_CR6","doi-asserted-by":"publisher","first-page":"619","DOI":"10.1111\/j.1743-6109.2008.01200.x","volume":"6","author":"GD Henry","year":"2009","unstructured":"Henry GD. The henry mummy wrap and the henry finger sweep surgical techniques. J Sex Med. 2009;6:619\u201322.","journal-title":"J Sex Med"},{"key":"1225_CR7","doi-asserted-by":"publisher","first-page":"265","DOI":"10.1111\/jsm.12728","volume":"12","author":"BB Garber","year":"2015","unstructured":"Garber BB, Bickell M. Delayed postoperative hematoma formation after inflatable penile prosthesis implantation. J Sex Med. 2015;12:265\u20139.","journal-title":"J Sex Med"},{"key":"1225_CR8","unstructured":"Shaeer O, Shaeer, OKM, Shaeer, K Shaeer\u2019s Corporotomy Closure Technique: Bringing Suturing Back VJSM2025 Available from: https:\/\/www.vjsm.info\/videos\/all\/shaeers-corporotomy-closure-technique-bringing-suturing-back."},{"key":"1225_CR9","doi-asserted-by":"publisher","first-page":"82","DOI":"10.1038\/s41443-023-00697-2","volume":"37","author":"AE Braun","year":"2025","unstructured":"Braun AE, Swerdloff D, Sudhakar A, Patel RD, Gross MS, Simhan J. Defining the incidence and management of postoperative scrotal hematoma after primary and complex three-piece inflatable penile prosthesis surgery. Int J Impot Res. 2025;37:82\u20136.","journal-title":"Int J Impot Res"},{"key":"1225_CR10","doi-asserted-by":"publisher","first-page":"S9","DOI":"10.1016\/j.jsxm.2022.01.028","volume":"19","author":"D Osmonov","year":"2022","unstructured":"Osmonov D, Ragheb A, Romero-Otero J, Bettocchi C, van Renterghem K, J\u00fcnemann K, et al. To drain or not to drain an inflatable penile prosthesis implantation? a multi-institutional experience tracking scrotal hematoma and infection occurrence. J Sex Med. 2022;19:S9.","journal-title":"J Sex Med"},{"key":"1225_CR11","doi-asserted-by":"publisher","first-page":"190","DOI":"10.1016\/j.urology.2017.06.002","volume":"108","author":"AT Rozanski","year":"2017","unstructured":"Rozanski AT, Viers BR, Liu AG, Shakir NA, Pagliara TJ, Scott JM, et al. Oxidized regenerated cellulose (Fibrillar) reduces risk of postoperative corporal bleeding following inflatable penile prosthesis surgery. Urology. 2017;108:190\u20134.","journal-title":"Urology"},{"key":"1225_CR12","doi-asserted-by":"publisher","first-page":"869","DOI":"10.1111\/jsm.12510","volume":"11","author":"SD Cohen","year":"2014","unstructured":"Cohen SD, Francois Eid J. Hemostatic matrix during corporotomy closure. J Sex Med. 2014;11:869\u201372.","journal-title":"J Sex Med"},{"key":"1225_CR13","doi-asserted-by":"publisher","first-page":"143","DOI":"10.1111\/j.1743-6109.2004.04058_5.x","volume":"1","author":"RM Andrianne","year":"2004","unstructured":"Andrianne RM. New technique for hydraulic penile prosthesis insertion and corporotomy closure. J Sex Med. 2004;1:143.","journal-title":"J Sex Med"},{"key":"1225_CR14","doi-asserted-by":"publisher","first-page":"508","DOI":"10.1093\/jsxmed\/qdaf009","volume":"22","author":"S Helo","year":"2025","unstructured":"Helo S, Bonakdar Hashemi M, Ziegelmann MJ, Lybbert DT, Piraino J, Guillen Lozoya AH, et al. Chlorhexidine gluconate application, diabetes, revision surgery, and extended operative time increase risk for penile implant infection. J Sex Med. 2025;22:508\u201316.","journal-title":"J Sex Med"}],"container-title":["International Journal of Impotence Research"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.nature.com\/articles\/s41443-026-01225-8.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.nature.com\/articles\/s41443-026-01225-8","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.nature.com\/articles\/s41443-026-01225-8.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,2,19]],"date-time":"2026-02-19T13:06:56Z","timestamp":1771506416000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.nature.com\/articles\/s41443-026-01225-8"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,2,16]]},"references-count":14,"alternative-id":["1225"],"URL":"https:\/\/doi.org\/10.1038\/s41443-026-01225-8","relation":{},"ISSN":["0955-9930","1476-5489"],"issn-type":[{"value":"0955-9930","type":"print"},{"value":"1476-5489","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,2,16]]},"assertion":[{"value":"5 June 2025","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"29 October 2025","order":2,"name":"revised","label":"Revised","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"5 January 2026","order":3,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"16 February 2026","order":4,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"The authors declare no competing interests.","order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}},{"value":"Informed consent was obtained from all individual participants included in the study.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Informed consent"}}]}}