{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,24]],"date-time":"2026-10-24T17:11:58Z","timestamp":1792861918411,"version":"4.5.0"},"reference-count":21,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2017,11,16]],"date-time":"2017-11-16T00:00:00Z","timestamp":1510790400000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2017,11,16]],"date-time":"2017-11-16T00:00:00Z","timestamp":1510790400000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Nat Commun"],"abstract":"<jats:title>Abstract<\/jats:title><jats:p>Endoscopic optical coherence tomography (OCT) has emerged as a valuable tool for advancing our understanding of the histomorphology of various internal luminal organs and studying the pathogenesis of relevant diseases. To date, this technology affords limited resolving power for discerning subtle pathological changes associated with early diseases. In addition, it remains challenging to access small luminal organs or pass through narrow luminal sections without potentially causing trauma to tissue with a traditional OCT endoscope of a 1-1.5\u2009mm diameter. Here we report an ultracompact (520\u2009\u00b5m in outer diameter and 5\u2009mm in rigid length) and super-achromatic microprobe made with a built-in monolithic fiber-optic ball lens, which achieves ultrahigh-resolution (1.7\u2009\u00b5m axial resolution in tissue and 6\u2009\u00b5m transverse resolution) for endoscopic OCT imaging at 800\u2009nm. Its performance and translational potential are demonstrated by in vivo imaging of a mouse colon, a rat esophagus, and small airways in sheep.<\/jats:p>","DOI":"10.1038\/s41467-017-01494-4","type":"journal-article","created":{"date-parts":[[2017,11,10]],"date-time":"2017-11-10T10:54:36Z","timestamp":1510311276000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":99,"title":["Super-achromatic monolithic microprobe for ultrahigh-resolution endoscopic optical coherence tomography at 800\u2009nm"],"prefix":"10.1038","volume":"8","author":[{"given":"Wu","family":"Yuan","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Robert","family":"Brown","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Wayne","family":"Mitzner","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Lonny","family":"Yarmus","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Xingde","family":"Li","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2017,11,16]]},"reference":[{"key":"1494_CR1","doi-asserted-by":"publisher","first-page":"970","DOI":"10.1038\/nm0995-970","volume":"1","author":"JG Fujimoto","year":"1995","unstructured":"Fujimoto, J. G. et al. Optical biopsy and imaging using optical coherence tomography. Nat. Med. 1, 970\u2013972 (1995).","journal-title":"Nat. Med."},{"key":"1494_CR2","doi-asserted-by":"publisher","first-page":"2037","DOI":"10.1126\/science.276.5321.2037","volume":"276","author":"GJ Tearney","year":"1997","unstructured":"Tearney, G. J. et al. In vivo endoscopic optical biopsy with optical coherence tomography. Science 276, 2037\u20132039 (1997).","journal-title":"Science"},{"key":"1494_CR3","doi-asserted-by":"publisher","first-page":"2405","DOI":"10.1364\/BOE.8.002405","volume":"8","author":"MJ Gora","year":"2017","unstructured":"Gora, M. J., Suter, M. J., Tearney, G. J. & Li, X. D. Endoscopic optical coherence tomography: technologies and clinical applications. Biomed. Opt. Express 8, 2405\u20132444 (2017).","journal-title":"Biomed. Opt. Express"},{"key":"1494_CR4","doi-asserted-by":"publisher","first-page":"1206","DOI":"10.1161\/01.CIR.93.6.1206","volume":"93","author":"ME Brezinski","year":"1996","unstructured":"Brezinski, M. E. et al. Optical coherence tomography for optical biopsy: properties and demonstration of vascular pathology. Circulation 93, 1206\u20131213 (1996).","journal-title":"Circulation"},{"key":"1494_CR5","doi-asserted-by":"publisher","DOI":"10.1117\/1.2399454","volume":"11","author":"AR Tumlinson","year":"2006","unstructured":"Tumlinson, A. R. et al. In vivo ultrahigh-resolution optical coherence tomography of mouse colon with an achromatized endoscope. J. Biomed. Opt. 11, 064003 (2006).","journal-title":"J. Biomed. Opt."},{"key":"1494_CR6","doi-asserted-by":"publisher","first-page":"984","DOI":"10.1378\/chest.10-0753","volume":"138","author":"RG Michel","year":"2010","unstructured":"Michel, R. G., Kinasewitz, G. T., Fung, K. M. & Keddissi, J. I. Optical coherence tomography as an adjunct to flexible bronchoscopy in the diagnosis of lung cancer: a pilot study. Chest 138, 984\u2013988 (2010).","journal-title":"Chest"},{"key":"1494_CR7","doi-asserted-by":"publisher","first-page":"238","DOI":"10.1038\/nm.3052","volume":"19","author":"MJ Gora","year":"2013","unstructured":"Gora, M. J. et al. Tethered capsule endomicroscopy enables less invasive imaging of gastrointestinal tract microstructure. Nat. Med. 19, 238\u2013240 (2013).","journal-title":"Nat. Med."},{"key":"1494_CR8","doi-asserted-by":"publisher","first-page":"886","DOI":"10.1016\/j.gie.2013.11.016","volume":"79","author":"MJ Suter","year":"2014","unstructured":"Suter, M. J. et al. Esophageal-guided biopsy with volumetric laser endomicroscopy and laser cautery marking: a pilot clinical study. Gastrointest. Endosc. 79, 886\u2013896 (2014).","journal-title":"Gastrointest. Endosc."},{"key":"1494_CR9","doi-asserted-by":"publisher","first-page":"1446","DOI":"10.1016\/j.rmed.2015.09.006","volume":"109","author":"Y Chen","year":"2015","unstructured":"Chen, Y. et al. Validation of human small airway measurements using endobronchial optical coherence tomography. Respir. Med. 109, 1446\u20131453 (2015).","journal-title":"Respir. Med."},{"key":"1494_CR10","doi-asserted-by":"publisher","DOI":"10.1126\/scitranslmed.aag1424","volume":"8","author":"DC Adams","year":"2016","unstructured":"Adams, D. C. et al. Birefringence microscopy platform for assessing airway smooth muscle structure and function in vivo. Sci. Transl. Med. 8, 359RA131 (2016).","journal-title":"Sci. Transl. Med."},{"key":"1494_CR11","doi-asserted-by":"publisher","first-page":"1281","DOI":"10.1016\/j.chest.2016.07.033","volume":"150","author":"M Ding","year":"2016","unstructured":"Ding, M. et al. Measuring Airway remodeling in patients with different copd staging using endobronchial optical coherence tomography. Chest 150, 1281\u20131290 (2016).","journal-title":"Chest"},{"key":"1494_CR12","doi-asserted-by":"publisher","first-page":"3894","DOI":"10.1364\/OL.36.003894","volume":"36","author":"D Lorenser","year":"2011","unstructured":"Lorenser, D. et al. Ultrathin side-viewing needle probe for optical coherence tomography. Opt. Lett. 36, 3894\u20133896 (2011).","journal-title":"Opt. Lett."},{"key":"1494_CR13","doi-asserted-by":"publisher","first-page":"2016","DOI":"10.1364\/OL.39.002016","volume":"39","author":"J Xi","year":"2014","unstructured":"Xi, J. et al. Diffractive catheter for ultrahigh-resolution spectral-domain volumetric OCT imaging. Opt. Lett. 39, 2016\u20132019 (2014).","journal-title":"Opt. Lett."},{"key":"1494_CR14","doi-asserted-by":"publisher","first-page":"250","DOI":"10.1364\/OL.41.000250","volume":"41","author":"W Yuan","year":"2016","unstructured":"Yuan, W. et al. Optimal operational conditions for supercontinuum-based ultrahigh-resolution endoscopic OCT imaging. Opt. Lett. 41, 250\u2013253 (2016).","journal-title":"Opt. Lett."},{"key":"1494_CR15","doi-asserted-by":"publisher","first-page":"1520","DOI":"10.1364\/OL.25.001520","volume":"25","author":"XD Li","year":"2000","unstructured":"Li, X. D., Chudoba, C., Ko, T., Pitris, C. & Fujimoto, J. G. Imaging needle for optical coherence tomography. Opt. Lett. 25, 1520\u20131522 (2000).","journal-title":"Opt. Lett."},{"key":"1494_CR16","doi-asserted-by":"publisher","first-page":"863","DOI":"10.1109\/JSTQE.2009.2035362","volume":"16","author":"Y Wu","year":"2010","unstructured":"Wu, Y. et al. Robust high-resolution fine OCT needle for side-viewing interstitial tissue imaging. IEEE J. Sel. Top. Quant. Elect. 16, 863\u2013869 (2010).","journal-title":"IEEE J. Sel. Top. Quant. Elect."},{"key":"1494_CR17","doi-asserted-by":"publisher","first-page":"1791","DOI":"10.1364\/OL.30.001791","volume":"30","author":"VXD Yang","year":"2005","unstructured":"Yang, V. X. D. et al. Interstitial Doppler optical coherence tomography. Opt. Lett. 30, 1791\u20131793 (2005).","journal-title":"Opt. Lett."},{"key":"1494_CR18","doi-asserted-by":"publisher","first-page":"223","DOI":"10.1364\/BOE.5.000223","volume":"5","author":"HS Cho","year":"2014","unstructured":"Cho, H. S. et al. High frame-rate intravascular optical frequency-domain imaging in vivo. Biomed. Opt. Express 5, 223\u2013232 (2014).","journal-title":"Biomed. Opt. Express"},{"key":"1494_CR19","doi-asserted-by":"publisher","first-page":"1947","DOI":"10.1364\/BOE.3.001947","volume":"3","author":"KM Tan","year":"2012","unstructured":"Tan, K. M. et al. Flexible transbronchial optical frequency domain imaging smart needle for biopsy guidance. Biomed. Opt. Exp. 3, 1947\u20131954 (2012).","journal-title":"Biomed. Opt. Exp."},{"key":"1494_CR20","doi-asserted-by":"publisher","first-page":"1567","DOI":"10.1056\/NEJMoa1106955","volume":"365","author":"JE McDonough","year":"2011","unstructured":"McDonough, J. E. et al. Small-airway obstruction and emphysema in chronic obstructive pulmonary disease. N. Engl. J. Med. 365, 1567\u20131575 (2011).","journal-title":"N. Engl. J. Med."},{"key":"1494_CR21","doi-asserted-by":"publisher","first-page":"11429","DOI":"10.1364\/OE.19.011429","volume":"19","author":"G Liu","year":"2011","unstructured":"Liu, G. et al. Intensity-based modified Doppler variance algorithm: application to phase instable and phase stable optical coherence tomography systems. Opt. Express 19, 11429\u201311440 (2011).","journal-title":"Opt. Express"}],"updated-by":[{"DOI":"10.1038\/s41467-018-03637-7","type":"correction","label":"Correction","source":"publisher","updated":{"date-parts":[[2018,3,14]],"date-time":"2018-03-14T00:00:00Z","timestamp":1520985600000}}],"container-title":["Nature Communications"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.nature.com\/articles\/s41467-017-01494-4","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.nature.com\/articles\/s41467-017-01494-4.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.nature.com\/articles\/s41467-017-01494-4.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2022,12,22]],"date-time":"2022-12-22T22:46:20Z","timestamp":1671749180000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.nature.com\/articles\/s41467-017-01494-4"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2017,11,16]]},"references-count":21,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2017,12]]}},"alternative-id":["1494"],"URL":"https:\/\/doi.org\/10.1038\/s41467-017-01494-4","relation":{"correction":[{"id-type":"doi","id":"10.1038\/s41467-018-03637-7","asserted-by":"object"}]},"ISSN":["2041-1723"],"issn-type":[{"value":"2041-1723","type":"electronic"}],"subject":[],"published":{"date-parts":[[2017,11,16]]},"assertion":[{"value":"3 May 2017","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"21 September 2017","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"16 November 2017","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"14 March 2018","order":4,"name":"change_date","label":"Change Date","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"Correction","order":5,"name":"change_type","label":"Change Type","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"The original version of this Article contained an error in the third sentence of the \u2018Animal studies\u2019 section of the Methods, which incorrectly read \u2018The sheep anesthesia was initiated with ketamine (25\u2009mg\u2009kg<sup>\u22121<\/sup>) and then maintained by continuous intravascular (IV) infusion of propofol (800\u2009mg\u2009kg<sup>\u22121<\/sup>\u2009h<sup>\u22121<\/sup>) during imaging.\u2019 The correct version states \u2018800\u2009\u00b5g\u2009kg<sup>\u22121<\/sup>\u2009h<sup>\u22121<\/sup>\u2019 in place of \u2018800\u2009mg\u2009kg<sup>\u22121<\/sup>\u2009h<sup>\u22121<\/sup>\u2019. This has been corrected in both the PDF and HTML versions of the article.","order":6,"name":"change_details","label":"Change Details","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"The authors declare no competing financial interests.","order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"1531"}}