{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,11,21]],"date-time":"2026-11-21T05:20:42Z","timestamp":1795238442710,"version":"4.10.3"},"reference-count":34,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2019,2,14]],"date-time":"2019-02-14T00:00:00Z","timestamp":1550102400000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2019,2,14]],"date-time":"2019-02-14T00:00:00Z","timestamp":1550102400000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Nat Commun"],"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:p>Subcortical neuronal activity is highly relevant for mediating communication in large-scale brain networks. While electroencephalographic (EEG) recordings provide appropriate temporal resolution and coverage to study whole brain dynamics, the feasibility to detect subcortical signals is a matter of debate. Here, we investigate if scalp EEG can detect and correctly localize signals recorded with intracranial electrodes placed in the centromedial thalamus, and in the nucleus accumbens. Externalization of deep brain stimulation (DBS) electrodes, placed in these regions, provides the unique opportunity to record subcortical activity simultaneously with high-density (256 channel) scalp EEG. In three patients during rest with eyes closed, we found significant correlation between alpha envelopes derived from intracranial and EEG source reconstructed signals. Highest correlation was found for source signals in close proximity to the actual recording sites, given by the DBS electrode locations. Therefore, we present direct evidence that scalp EEG indeed can sense subcortical signals.<\/jats:p>","DOI":"10.1038\/s41467-019-08725-w","type":"journal-article","created":{"date-parts":[[2019,2,14]],"date-time":"2019-02-14T06:03:38Z","timestamp":1550124218000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":285,"title":["Subcortical electrophysiological activity is detectable with high-density EEG source imaging"],"prefix":"10.1038","volume":"10","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-7891-5636","authenticated-orcid":false,"given":"Martin","family":"Seeber","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Lucia-Manuela","family":"Cantonas","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Mauritius","family":"Hoevels","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Thibaut","family":"Sesia","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Veerle","family":"Visser-Vandewalle","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Christoph M.","family":"Michel","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2019,2,14]]},"reference":[{"key":"8725_CR1","doi-asserted-by":"publisher","first-page":"2195","DOI":"10.1016\/j.clinph.2004.06.001","volume":"115","author":"CM Michel","year":"2004","unstructured":"Michel, C. M. et al. EEG source imaging. Clin. Neurophysiol. 115, 2195\u20132222 (2004).","journal-title":"Clin. Neurophysiol."},{"key":"8725_CR2","doi-asserted-by":"publisher","first-page":"171","DOI":"10.1146\/annurev-bioeng-062117-120853","volume":"20","author":"B He","year":"2018","unstructured":"He, B., Sohrabpour, A., Brown, E. & Liu, Z. Electrophysiological Source Imaging: A noninvasive window to brain dynamics. Annu. Rev. Biomed. Eng. 20, 171\u2013196 (2018).","journal-title":"Annu. Rev. Biomed. Eng."},{"key":"8725_CR3","doi-asserted-by":"publisher","first-page":"371","DOI":"10.1016\/j.neuroimage.2011.12.039","volume":"61","author":"CM Michel","year":"2012","unstructured":"Michel, C. M. & Murray, M. M. Towards the utilization of EEG as a brain imaging tool. Neuroimage 61, 371\u2013385 (2012).","journal-title":"Neuroimage"},{"key":"8725_CR4","doi-asserted-by":"crossref","unstructured":"Michel C.M., He B. EEG Mapping and Source Imaging. In: Niedermeyer's Electroencephalography: Basic Principles, Clinical Applications, and Related Fields Seventh Edition (Eds.: D.L. Schomer & F.H. Lopes da Silva). Oxford University Press, New York, 2018, Chapter 45, pp. 1135\u20131156.","DOI":"10.1093\/med\/9780190228484.003.0045"},{"key":"8725_CR5","doi-asserted-by":"publisher","first-page":"38","DOI":"10.1136\/jnnp-2013-305515","volume":"85","author":"P Megevand","year":"2013","unstructured":"Megevand, P. et al. Electric source imaging of interictal activity accurately localises the seizure onset zone. J. Neurol., Neurosurg. & Psychiatry 85, 38\u201343 (2013).","journal-title":"J. Neurol., Neurosurg. & Psychiatry"},{"key":"8725_CR6","doi-asserted-by":"publisher","first-page":"2887","DOI":"10.1093\/brain\/awr243","volume":"134","author":"V Brodbeck","year":"2011","unstructured":"Brodbeck, V. et al. Electroencephalographic source imaging: a prospective study of 152 operated epileptic patients. Brain 134, 2887\u20132897 (2011).","journal-title":"Brain"},{"key":"8725_CR7","doi-asserted-by":"publisher","first-page":"689","DOI":"10.1002\/hipo.20819","volume":"21","author":"L Nahum","year":"2011","unstructured":"Nahum, L. et al. Rapid consolidation and the human hippocampus: Intracranial recordings confirm surface EEG. Hippocampus 21, 689\u2013693 (2011).","journal-title":"Hippocampus"},{"key":"8725_CR8","doi-asserted-by":"publisher","first-page":"517","DOI":"10.1227\/NEU.0000000000000298","volume":"74","author":"AM Lascano","year":"2014","unstructured":"Lascano, A. M. et al. Surgically relevant localization of the central sulcus with high-density somatosensory-evoked potentials compared with functional magnetic resonance imaging. Neurosurgery 74, 517\u2013526 (2014).","journal-title":"Neurosurgery"},{"key":"8725_CR9","doi-asserted-by":"publisher","first-page":"87","DOI":"10.1007\/s10548-014-0405-3","volume":"28","author":"S Klamer","year":"2014","unstructured":"Klamer, S. et al. Differences between MEG and high-density EEG source localizations using a distributed source model in comparison to fMRI. Brain Topogr. 28, 87\u201394 (2014).","journal-title":"Brain Topogr."},{"key":"8725_CR10","doi-asserted-by":"publisher","first-page":"e59856","DOI":"10.1371\/journal.pone.0059856","volume":"8","author":"Y Attal","year":"2013","unstructured":"Attal, Y. & Schwartz, D. Assessment of subcortical source localization using deep brain activity imaging model with minimum norm operators: a MEG study. PLoS One 8, e59856 (2013).","journal-title":"PLoS One"},{"key":"8725_CR11","doi-asserted-by":"publisher","first-page":"17827","DOI":"10.1523\/JNEUROSCI.5778-12.2013","volume":"33","author":"F Roux","year":"2013","unstructured":"Roux, F., Wibral, M., Singer, W., Aru, J. & Uhlhaas, P. J. The phase of thalamic alpha activity modulates cortical gamma-band activity: evidence from resting-state MEG recordings. J. Neurosci. 33, 17827\u201317835 (2013).","journal-title":"J. Neurosci."},{"key":"8725_CR12","doi-asserted-by":"publisher","first-page":"E10465","DOI":"10.1073\/pnas.1705414114","volume":"114","author":"P Krishnaswamy","year":"2017","unstructured":"Krishnaswamy, P. et al. Sparsity enables estimation of both subcortical and cortical activity from MEG and EEG. Proc. Natl Acad. Sci. USA 114, E10465\u2013E10474 (2017).","journal-title":"Proc. Natl Acad. Sci. USA"},{"key":"8725_CR13","doi-asserted-by":"publisher","first-page":"527","DOI":"10.1016\/j.neuroimage.2003.09.051","volume":"21","author":"R Grave de Peralta Menendez","year":"2004","unstructured":"Grave de Peralta Menendez, R., Murray, M. M., Michel, C. M., Martuzzi, R. & Gonzalez Andino, S. L. Electrical neuroimaging based on biophysical constraints. Neuroimage 21, 527\u2013539 (2004).","journal-title":"Neuroimage"},{"key":"8725_CR14","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1155\/2011\/813870","volume":"2011","author":"D Brunet","year":"2011","unstructured":"Brunet, D., Murray, M. M. & Michel, C. M. Spatiotemporal analysis of multichannel EEG: CARTOOL. Comput. Intell. Neurosci. 2011, 1\u201315 (2011).","journal-title":"Comput. Intell. Neurosci."},{"key":"8725_CR15","doi-asserted-by":"publisher","first-page":"77","DOI":"10.1016\/j.nicl.2014.06.005","volume":"5","author":"G Birot","year":"2014","unstructured":"Birot, G. et al. Head model and electrical source imaging: A study of 38 epileptic patients. NeuroImage: Clin. 5, 77\u201383 (2014).","journal-title":"NeuroImage: Clin."},{"key":"8725_CR16","doi-asserted-by":"publisher","first-page":"627","DOI":"10.1016\/0013-4694(73)90216-2","volume":"35","author":"FH Lopes da Silva","year":"1973","unstructured":"Lopes da Silva, F. H., van Lierop, T. H. M. T., Schrijer, C. F. & Storm van Leeuwen, W. Organization of thalamic and cortical alpha rhythms: spectra and coherences. Electroencephalogr. Clin. Neurophysiol. 35, 627\u2013639 (1973).","journal-title":"Electroencephalogr. Clin. Neurophysiol."},{"key":"8725_CR17","doi-asserted-by":"publisher","first-page":"449","DOI":"10.1016\/0013-4694(80)90011-5","volume":"50","author":"FH Lopes da Silva","year":"1980","unstructured":"Lopes da Silva, F. H., Vos, J. E., Mooibroek, J. & van Rotterdam, A. Relative contributions of intracortical and thalamo-cortical processes in the generation of alpha rhythms, revealed by partial coherence analysis. Electroencephalogr. Clin. Neurophysiol. 50, 449\u2013456 (1980).","journal-title":"Electroencephalogr. Clin. Neurophysiol."},{"key":"8725_CR18","doi-asserted-by":"publisher","first-page":"1112","DOI":"10.1016\/j.neuron.2013.10.017","volume":"80","author":"F Lopes da Silva","year":"2013","unstructured":"Lopes da Silva, F. EEG and MEG: relevance to neuroscience. Neuron 80, 1112\u20131128 (2013).","journal-title":"Neuron"},{"key":"8725_CR19","doi-asserted-by":"publisher","first-page":"71","DOI":"10.1097\/00004691-200403000-00001","volume":"21","author":"CM Michel","year":"2004","unstructured":"Michel, C. M. et al. 128-channel EEG source imaging in epilepsy: clinical yield and localization precision. J. Clin. Neurophysiol. 21, 71\u201383 (2004).","journal-title":"J. Clin. Neurophysiol."},{"key":"8725_CR20","doi-asserted-by":"publisher","first-page":"300","DOI":"10.1002\/mds.22982","volume":"25","author":"S Marceglia","year":"2010","unstructured":"Marceglia, S. et al. Thalamic single-unit and local field potential activity in Tourette syndrome. Mov. Disord. 25, 300\u2013308 (2010).","journal-title":"Mov. Disord."},{"key":"8725_CR21","doi-asserted-by":"publisher","first-page":"875","DOI":"10.1162\/jocn.2009.21062","volume":"21","author":"MX Cohen","year":"2009","unstructured":"Cohen, M. X. et al. Good vibrations: cross-frequency coupling in the human nucleus accumbens during reward processing. J. Cogn. Neurosci. 21, 875\u2013889 (2009).","journal-title":"J. Cogn. Neurosci."},{"key":"8725_CR22","doi-asserted-by":"publisher","first-page":"4935","DOI":"10.1523\/JNEUROSCI.5580-10.2011","volume":"31","author":"A Bollimunta","year":"2011","unstructured":"Bollimunta, A., Mo, J., Schroeder, C. E. & Ding, M. Neuronal mechanisms and attentional modulation of corticothalamic alpha oscillations. J. Neurosci. 31, 4935\u20134943 (2011).","journal-title":"J. Neurosci."},{"key":"8725_CR23","doi-asserted-by":"publisher","first-page":"14341","DOI":"10.1523\/JNEUROSCI.0600-15.2015","volume":"35","author":"S Haegens","year":"2015","unstructured":"Haegens, S. et al. Laminar profile and physiology of the rhythm in primary visual, auditory, and somatosensory regions of neocortex. J. Neurosci. 35, 14341\u201314352 (2015).","journal-title":"J. Neurosci."},{"key":"8725_CR24","doi-asserted-by":"publisher","first-page":"6","DOI":"10.1007\/BF01815532","volume":"97","author":"H Berger","year":"1932","unstructured":"Berger, H. \u00dcber das elektrenkephalogramm des menschen. Arch. f\u00fcr Psychiatr. und Nervenkrankh. 97, 6\u201326 (1932).","journal-title":"Arch. f\u00fcr Psychiatr. und Nervenkrankh."},{"key":"8725_CR25","first-page":"155","volume":"167","author":"E Niedermeyer","year":"2005","unstructured":"Niedermeyer, E. The normal EEG of the waking adult. Electroencephalogr.: Basic Princ., Clin. Appl., Relat. Fields 167, 155\u2013164 (2005).","journal-title":"Electroencephalogr.: Basic Princ., Clin. Appl., Relat. Fields"},{"key":"8725_CR26","doi-asserted-by":"publisher","first-page":"337","DOI":"10.1016\/S0166-2236(99)01407-1","volume":"22","author":"M Steriade","year":"1999","unstructured":"Steriade, M. Coherent oscillations and short-term plasticity in corticothalamic networks. Trends Neurosci. 22, 337\u2013345 (1999).","journal-title":"Trends Neurosci."},{"key":"8725_CR27","doi-asserted-by":"publisher","first-page":"70","DOI":"10.1109\/TAU.1967.1161901","volume":"15","author":"P Welch","year":"1967","unstructured":"Welch, P. The use of fast Fourier transform for the estimation of power spectra: a method based on time averaging over short, modified periodograms. IEEE Trans. Audio Electro. 15, 70\u201373 (1967).","journal-title":"IEEE Trans. Audio Electro."},{"key":"8725_CR28","doi-asserted-by":"publisher","first-page":"179","DOI":"10.1006\/nimg.1998.0395","volume":"9","author":"AM Dale","year":"1999","unstructured":"Dale, A. M., Fischl, B. & Sereno, M. I. Cortical surface-based analysis. Neuroimage 9, 179\u2013194 (1999).","journal-title":"Neuroimage"},{"key":"8725_CR29","doi-asserted-by":"publisher","first-page":"341","DOI":"10.1016\/S0896-6273(02)00569-X","volume":"33","author":"B Fischl","year":"2002","unstructured":"Fischl, B. et al. Whole brain segmentation. Neuron 33, 341\u2013355 (2002).","journal-title":"Neuron"},{"key":"8725_CR30","doi-asserted-by":"publisher","first-page":"11","DOI":"10.1093\/cercor\/bhg087","volume":"14","author":"B Fischl","year":"2004","unstructured":"Fischl, B. Automatically parcellating the human cerebral cortex. Cereb. Cortex 14, 11\u201322 (2004).","journal-title":"Cereb. Cortex"},{"key":"8725_CR31","doi-asserted-by":"publisher","first-page":"825","DOI":"10.1006\/nimg.2002.1132","volume":"17","author":"M Jenkinson","year":"2002","unstructured":"Jenkinson, M. Improved optimization for the robust and accurate linear registration and motion correction of brain images. Neuroimage 17, 825\u2013841 (2002).","journal-title":"Neuroimage"},{"key":"8725_CR32","doi-asserted-by":"publisher","first-page":"S208","DOI":"10.1016\/j.neuroimage.2004.07.051","volume":"23","author":"SM Smith","year":"2004","unstructured":"Smith, S. M. et al. Advances in functional and structural MR image analysis and implementation as FSL. Neuroimage 23, S208\u2013S219 (2004).","journal-title":"Neuroimage"},{"key":"8725_CR33","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1002\/hbm.1058","volume":"15","author":"TE Nichols","year":"2002","unstructured":"Nichols, T. E. & Holmes, A. P. Nonparametric permutation tests for functional neuroimaging: a primer with examples. Hum. Brain. Mapp. 15, 1\u201325 (2002).","journal-title":"Hum. Brain. Mapp."},{"key":"8725_CR34","doi-asserted-by":"publisher","first-page":"177","DOI":"10.1016\/j.jneumeth.2007.03.024","volume":"164","author":"E Maris","year":"2007","unstructured":"Maris, E. & Oostenveld, R. Nonparametric statistical testing of EEG- and MEG-data. J. Neurosci. Methods 164, 177\u2013190 (2007).","journal-title":"J. Neurosci. Methods"}],"container-title":["Nature Communications"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.nature.com\/articles\/s41467-019-08725-w.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.nature.com\/articles\/s41467-019-08725-w","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.nature.com\/articles\/s41467-019-08725-w.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2022,12,16]],"date-time":"2022-12-16T16:05:27Z","timestamp":1671206727000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.nature.com\/articles\/s41467-019-08725-w"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2019,2,14]]},"references-count":34,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2019,12]]}},"alternative-id":["8725"],"URL":"https:\/\/doi.org\/10.1038\/s41467-019-08725-w","relation":{},"ISSN":["2041-1723"],"issn-type":[{"value":"2041-1723","type":"electronic"}],"subject":[],"published":{"date-parts":[[2019,2,14]]},"assertion":[{"value":"8 October 2018","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"28 January 2019","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"14 February 2019","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"C.M.M. declares having received remuneration for a research forum organized by Philips Healthcare. The remaining authors declare no competing interests.","order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"753"}}