{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,30]],"date-time":"2026-10-30T00:17:54Z","timestamp":1793319474506,"version":"4.5.0"},"reference-count":23,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2019,7,16]],"date-time":"2019-07-16T00:00:00Z","timestamp":1563235200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2019,7,16]],"date-time":"2019-07-16T00:00:00Z","timestamp":1563235200000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Nat Commun"],"abstract":"<jats:title>Abstract<\/jats:title><jats:p>Iatrogenic injury of the ureters is a feared complication of abdominal surgery. Zwitterionic near-infrared fluorophores are molecules with geometrically-balanced, electrically-neutral surface charge, which leads to renal-exclusive clearance and ultralow non-specific background binding. Such molecules could solve the ureter mapping problem by providing real-time anatomic and functional imaging, even through intact peritoneum. Here we present the first-in-human experience of this chemical class, as well as the efficacy study in patients undergoing laparoscopic abdominopelvic surgery. The zwitterionic near-infrared fluorophore ZW800-1 is safe, has pharmacokinetic properties consistent with an ideal blood pool agent, and rapid elimination into urine after a single low-dose intravenous injection. Visualization of structure and function of the ureters starts within minutes after ZW800-1 injection and lasts several hours. Zwitterionic near-infrared fluorophores add value during laparoscopic abdominopelvic surgeries and could potentially decrease iatrogenic urethral injury. Moreover, ZW800-1 is engineered for one-step covalent conjugatability, creating possibilities for developing novel targeted ligands.<\/jats:p>","DOI":"10.1038\/s41467-019-11014-1","type":"journal-article","created":{"date-parts":[[2019,7,16]],"date-time":"2019-07-16T10:03:16Z","timestamp":1563271396000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":75,"title":["A zwitterionic near-infrared fluorophore for real-time ureter identification during laparoscopic abdominopelvic surgery"],"prefix":"10.1038","volume":"10","author":[{"given":"Kim S.","family":"de Valk","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-5114-3584","authenticated-orcid":false,"given":"Henricus J.","family":"Handgraaf","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Marion M.","family":"Deken","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Babs G.","family":"Sibinga Mulder","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Adrianus R.","family":"Valentijn","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Anton G.","family":"Terwisscha van Scheltinga","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Joeri","family":"Kuil","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Michiel J.","family":"van Esdonk","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jaap","family":"Vuijk","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Rob F.","family":"Bevers","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Koen C.","family":"Peeters","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Fabian A.","family":"Holman","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"John V.","family":"Frangioni","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jacobus","family":"Burggraaf","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Alexander L.","family":"Vahrmeijer","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2019,7,16]]},"reference":[{"key":"11014_CR1","doi-asserted-by":"publisher","first-page":"507","DOI":"10.1038\/nrclinonc.2013.123","volume":"10","author":"AL Vahrmeijer","year":"2013","unstructured":"Vahrmeijer, A. L., Hutteman, M., van der Vorst, J. R., van de Velde, C. J. & Frangioni, J. V. Image-guided cancer surgery using near-infrared fluorescence. Nat. Rev. Clin. Oncol. 10, 507\u2013518 (2013).","journal-title":"Nat. Rev. Clin. Oncol."},{"key":"11014_CR2","doi-asserted-by":"publisher","first-page":"148","DOI":"10.1038\/nbt.2468","volume":"31","author":"HS Choi","year":"2013","unstructured":"Choi, H. S. et al. Targeted zwitterionic near-infrared fluorophores for improved optical imaging. Nat. Biotechnol. 31, 148\u2013153 (2013).","journal-title":"Nat. Biotechnol."},{"key":"11014_CR3","doi-asserted-by":"publisher","first-page":"6258","DOI":"10.1002\/anie.201102459","volume":"50","author":"HS Choi","year":"2011","unstructured":"Choi, H. S. et al. Synthesis and in vivo fate of zwitterionic near-infrared fluorophores. Angew. Chem. Int. Ed. Engl. 50, 6258\u20136263 (2011).","journal-title":"Angew. Chem. Int. Ed. Engl."},{"key":"11014_CR4","doi-asserted-by":"publisher","first-page":"52","DOI":"10.1007\/s11307-015-0870-4","volume":"18","author":"H Hyun","year":"2016","unstructured":"Hyun, H. et al. 700-nm Zwitterionic near-infrared fluorophores for dual-channel image-guided surgery. Mol. Imaging Biol. 18, 52\u201361 (2016).","journal-title":"Mol. Imaging Biol."},{"key":"11014_CR5","doi-asserted-by":"publisher","first-page":"516","DOI":"10.1002\/cmmi.1484","volume":"7","author":"H Hyun","year":"2012","unstructured":"Hyun, H. et al. cGMP-compatible preparative scale synthesis of near-infrared fluorophores. Contrast Media Mol. Imaging 7, 516\u2013524 (2012).","journal-title":"Contrast Media Mol. Imaging"},{"key":"11014_CR6","doi-asserted-by":"publisher","first-page":"104","DOI":"10.1055\/s-0030-1254297","volume":"23","author":"SE Delacroix Jr.","year":"2010","unstructured":"Delacroix, S. E. Jr. & Winters, J. C. Urinary tract injures: recognition and management. Clin. Colon Rectal Surg. 23, 104\u2013112 (2010).","journal-title":"Clin. Colon Rectal Surg."},{"key":"11014_CR7","doi-asserted-by":"publisher","first-page":"1406","DOI":"10.1007\/s00464-014-3814-1","volume":"29","author":"P Andersen","year":"2015","unstructured":"Andersen, P., Andersen, L. M. & Iversen, L. H. Iatrogenic ureteral injury in colorectal cancer surgery: a nationwide study comparing laparoscopic and open approaches. Surg. Endosc. 29, 1406\u20131412 (2015).","journal-title":"Surg. Endosc."},{"key":"11014_CR8","doi-asserted-by":"crossref","first-page":"331","DOI":"10.1097\/MOU.0000000000000175","volume":"25","author":"O Engel","year":"2015","unstructured":"Engel, O., Rink, M. & Fisch, M. Management of iatrogenic ureteral injury and techniques for ureteral reconstruction. Curr. Opin. Urol. 25, 331\u2013335 (2015).","journal-title":"Curr. Opin. Urol."},{"key":"11014_CR9","doi-asserted-by":"crossref","first-page":"19","DOI":"10.1111\/tog.12073","volume":"16","author":"V Minas","year":"2014","unstructured":"Minas, V., Gul, N., Aust, T., Doyle, M. & Rowlands, D. Urinary tract injuries in laparoscopic gynaecological surgery; prevention, recognition and management. Obstet. Gynaecol. 16, 19\u201328 (2014).","journal-title":"Obstet. Gynaecol."},{"key":"11014_CR10","doi-asserted-by":"publisher","first-page":"1005","DOI":"10.1148\/radiographics.22.5.g02se081005","volume":"22","author":"RB Dyer","year":"2002","unstructured":"Dyer, R. B. et al. Complications of ureteral stent placement. Radiographics 22, 1005\u20131022 (2002).","journal-title":"Radiographics"},{"key":"11014_CR11","doi-asserted-by":"publisher","first-page":"2197","DOI":"10.1016\/j.juro.2007.06.049","volume":"178","author":"E Tanaka","year":"2007","unstructured":"Tanaka, E. et al. Real-time intraoperative ureteral guidance using invisible near-infrared fluorescence. J. Urol. 178, 2197\u20132202 (2007).","journal-title":"J. Urol."},{"key":"11014_CR12","doi-asserted-by":"publisher","first-page":"78","DOI":"10.1016\/j.surg.2009.12.003","volume":"148","author":"A Matsui","year":"2010","unstructured":"Matsui, A. et al. Real-time, near-infrared, fluorescence-guided identification of the ureters using methylene blue. Surgery 148, 78\u201386 (2010).","journal-title":"Surgery"},{"key":"11014_CR13","doi-asserted-by":"publisher","first-page":"909","DOI":"10.1038\/nrd3845","volume":"11","author":"J Bowes","year":"2012","unstructured":"Bowes, J. et al. Reducing safety-related drug attrition: the use of in vitro pharmacological profiling. Nat. Rev. Drug Discov. 11, 909\u2013922 (2012).","journal-title":"Nat. Rev. Drug Discov."},{"key":"11014_CR14","doi-asserted-by":"publisher","first-page":"659","DOI":"10.1096\/fj.07-9574LSF","volume":"22","author":"S Reagan-Shaw","year":"2008","unstructured":"Reagan-Shaw, S., Nihal, M. & Ahmad, N. Dose translation from animal to human studies revisited. FASEB J. 22, 659\u2013661 (2008).","journal-title":"FASEB J."},{"key":"11014_CR15","unstructured":"FDA. Estimating the Maximum Safe Starting Dose in Initial Clinical Trials for Therapeutics in Adult Healthy Volunteers (FDA, Maryland, 2005)."},{"key":"11014_CR16","doi-asserted-by":"publisher","first-page":"58762","DOI":"10.1039\/C4RA11225C","volume":"4","author":"H Hyun","year":"2014","unstructured":"Hyun, H. et al. Central C-C bonding increases optical and chemical stability of NIR fluorophores. RSC Adv. 4, 58762\u201358768 (2014).","journal-title":"RSC Adv."},{"key":"11014_CR17","doi-asserted-by":"publisher","first-page":"238","DOI":"10.5662\/wjm.v5.i4.238","volume":"5","author":"A Buia","year":"2015","unstructured":"Buia, A., Stockhausen, F. & Hanisch, E. Laparoscopic surgery: a qualified systematic review. World J. Methodol. 5, 238\u2013254 (2015).","journal-title":"World J. Methodol."},{"key":"11014_CR18","doi-asserted-by":"publisher","first-page":"574","DOI":"10.1016\/j.juro.2013.02.3187","volume":"190","author":"FP Verbeek","year":"2013","unstructured":"Verbeek, F. P. et al. Intraoperative near infrared fluorescence guided identification of the ureters using low dose methylene blue: a first in human experience. J. Urol. 190, 574\u2013579 (2013).","journal-title":"J. Urol."},{"key":"11014_CR19","doi-asserted-by":"publisher","first-page":"952","DOI":"10.1007\/s00464-016-5007-6","volume":"31","author":"LS Boogerd","year":"2017","unstructured":"Boogerd, L. S. et al. Laparoscopic detection and resection of occult liver tumors of multiple cancer types using real-time near-infrared fluorescence guidance. Surg. Endosc. 31, 952\u2013961 (2017).","journal-title":"Surg. Endosc."},{"key":"11014_CR20","doi-asserted-by":"publisher","first-page":"323","DOI":"10.1002\/jso.21943","volume":"104","author":"BE Schaafsma","year":"2011","unstructured":"Schaafsma, B. E. et al. The clinical use of indocyanine green as a near-infrared fluorescent contrast agent for image-guided oncologic surgery. J. Surg. Oncol. 104, 323\u2013332 (2011).","journal-title":"J. Surg. Oncol."},{"key":"11014_CR21","doi-asserted-by":"publisher","first-page":"1369","DOI":"10.1002\/bjs.7125","volume":"97","author":"T Ishizawa","year":"2010","unstructured":"Ishizawa, T. et al. Fluorescent cholangiography illuminating the biliary tree during laparoscopic cholecystectomy. Br. J. Surg. 97, 1369\u20131377 (2010).","journal-title":"Br. J. Surg."},{"key":"11014_CR22","doi-asserted-by":"publisher","first-page":"231","DOI":"10.1002\/ccd.1810170410","volume":"17","author":"R Benya","year":"1989","unstructured":"Benya, R., Quintana, J. & Brundage, B. Adverse reactions to indocyanine green: a case report and a review of the literature. Cathet. Cardiovasc. Diagn. 17, 231\u2013233 (1989).","journal-title":"Cathet. Cardiovasc. Diagn."},{"key":"11014_CR23","doi-asserted-by":"publisher","first-page":"249","DOI":"10.1111\/j.1365-2125.2007.03023.x","volume":"64","author":"A Cohen","year":"2007","unstructured":"Cohen, A. Should we tolerate tolerability as an objective in early drug development? Br. J. Clin. Pharmacol. 64, 249\u2013252 (2007).","journal-title":"Br. J. Clin. Pharmacol."}],"container-title":["Nature Communications"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.nature.com\/articles\/s41467-019-11014-1.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.nature.com\/articles\/s41467-019-11014-1","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.nature.com\/articles\/s41467-019-11014-1.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2022,12,17]],"date-time":"2022-12-17T00:24:37Z","timestamp":1671236677000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.nature.com\/articles\/s41467-019-11014-1"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2019,7,16]]},"references-count":23,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2019,12]]}},"alternative-id":["11014"],"URL":"https:\/\/doi.org\/10.1038\/s41467-019-11014-1","relation":{},"ISSN":["2041-1723"],"issn-type":[{"value":"2041-1723","type":"electronic"}],"subject":[],"published":{"date-parts":[[2019,7,16]]},"assertion":[{"value":"27 September 2018","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"5 June 2019","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"16 July 2019","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"J.V.F. is founder and CEO of Curadel, LLC, a for-profit company marketing the FLARE<sup>\u00ae<\/sup> technology platform for NIR fluorescence-guided surgery. The other authors declare no competing interests.","order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"3118"}}