{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,11,9]],"date-time":"2026-11-09T19:29:54Z","timestamp":1794252594299,"version":"4.9.0"},"reference-count":44,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2020,7,31]],"date-time":"2020-07-31T00:00:00Z","timestamp":1596153600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2020,7,31]],"date-time":"2020-07-31T00:00:00Z","timestamp":1596153600000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Nat Commun"],"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:p>Currently, human magnetic resonance (MR) examinations are becoming highly specialized with a pre-defined and often relatively small target in the body. Conventionally, clinical MR equipment is designed to be universal that compromises its efficiency for small targets. Here, we present a concept for targeted clinical magnetic resonance imaging (MRI), which can be directly integrated into the existing clinical MR systems, and demonstrate its feasibility for breast imaging. The concept comprises spatial redistribution and passive focusing of the radiofrequency magnetic flux with the aid of an artificial resonator to maximize the efficiency of a conventional MR system for the area of interest. The approach offers the prospect of a targeted MRI and brings novel opportunities for high quality specialized MR examinations within any existing MR system.<\/jats:p>","DOI":"10.1038\/s41467-020-17598-3","type":"journal-article","created":{"date-parts":[[2020,7,31]],"date-time":"2020-07-31T06:05:51Z","timestamp":1596175551000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":50,"title":["Ceramic resonators for targeted clinical magnetic resonance imaging of the breast"],"prefix":"10.1038","volume":"11","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-2473-1938","authenticated-orcid":false,"given":"Alena","family":"Shchelokova","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Viacheslav","family":"Ivanov","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Anna","family":"Mikhailovskaya","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-7480-1466","authenticated-orcid":false,"given":"Egor","family":"Kretov","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ivan","family":"Sushkov","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Svetlana","family":"Serebryakova","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Elizaveta","family":"Nenasheva","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Irina","family":"Melchakova","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Pavel","family":"Belov","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-4674-5767","authenticated-orcid":false,"given":"Alexey","family":"Slobozhanyuk","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-6359-0763","authenticated-orcid":false,"given":"Anna","family":"Andreychenko","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2020,7,31]]},"reference":[{"key":"17598_CR1","unstructured":"Mordor Intelligence LLP. Magnetic Resonance imaging (MRI) Market-Growth, Trends, and Forecast (2019\u20132024) (Mordor Intelligence LLP, 2019). https:\/\/www.marketinsightsreports.com\/reports\/08071391083\/magnetic-resonance-imaging-mri-market-growth-trends-and-forecast-2019-2024"},{"key":"17598_CR2","doi-asserted-by":"crossref","first-page":"e4039","DOI":"10.1002\/nbm.4039","volume":"32","author":"E Krikken","year":"2018","unstructured":"Krikken, E. et al. Homogeneous B1\n+ for bilateral breast imaging at 7 T using a five dipole transmit array merged with a high density receive loop array. NMR Biomed. 32, e4039 (2018).","journal-title":"NMR Biomed."},{"key":"17598_CR3","doi-asserted-by":"crossref","DOI":"10.1017\/CBO9780511760976","volume-title":"Introduction to Medical Imaging Physics, Engineering and Clinical Applications","author":"NB Smith","year":"2010","unstructured":"Smith, N. B. & Webb, A. Introduction to Medical Imaging Physics, Engineering and Clinical Applications (Cambridge Univ. Press, UK, 2010)."},{"key":"17598_CR4","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1002\/cmr.b.10090","volume":"19B","author":"DM Peterson","year":"2003","unstructured":"Peterson, D. M. et al. Common mode signal rejection methods for MRI: reduction of cable shield currents for high static magnetic field systems. Concepts Magn. Reson. Part B 19B, 1\u20138 (2003).","journal-title":"Concepts Magn. Reson. Part B"},{"key":"17598_CR5","volume-title":"RF Coils for MRI","author":"J Vaughan","year":"2012","unstructured":"Vaughan, J. & Griffiths, J. RF Coils for MRI (Wiley, New York, 2012)."},{"key":"17598_CR6","doi-asserted-by":"crossref","first-page":"438","DOI":"10.3322\/caac.21583","volume":"69","author":"CE DeSantis","year":"2019","unstructured":"DeSantis, C. E. et al. Breast Cancer Statistics, 2019. CA Cancer J. Clin. 69, 438\u2013451 (2019).","journal-title":"CA Cancer J. Clin."},{"key":"17598_CR7","doi-asserted-by":"crossref","first-page":"1804","DOI":"10.1016\/S0140-6736(11)61350-0","volume":"378","author":"M Morrow","year":"2011","unstructured":"Morrow, M., Waters, J. & Morris, E. MRI for breast cancer screening, diagnosis, and treatment. Lancet 378, 1804\u20131811 (2011).","journal-title":"Lancet"},{"key":"17598_CR8","doi-asserted-by":"crossref","first-page":"689","DOI":"10.1148\/radiol.2015150425","volume":"278","author":"S Bickelhaupt","year":"2016","unstructured":"Bickelhaupt, S. et al. Fast and noninvasive characterization of suspicious lesions detected at breast cancer X-ray screening: capability of diffusion-weighted MR imaging with MIPs. Radiology 278, 689\u2013697 (2016).","journal-title":"Radiology"},{"key":"17598_CR9","doi-asserted-by":"crossref","first-page":"895","DOI":"10.1002\/mrm.27079","volume":"80","author":"S Zhang","year":"2018","unstructured":"Zhang, S. et al. CEST-Dixon for human breast lesion characterization at 3T: a preliminary study. Magn. Reson. Med. 80, 895\u2013903 (2018).","journal-title":"Magn. Reson. Med."},{"key":"17598_CR10","doi-asserted-by":"crossref","unstructured":"S\u00e1nchez-Gonz\u00e1lez, J. and Luna, A. in Diffusion MRI Outside the Brain: A Case-Based Review and Clinical Applications (eds Luna, A., Ribes, R., & Soto J. A.) 51\u201372 (Springer Science & Business Media, 2011).","DOI":"10.1007\/978-3-642-21052-5_4"},{"key":"17598_CR11","doi-asserted-by":"crossref","first-page":"155","DOI":"10.1016\/j.jmr.2012.11.024","volume":"229","author":"E Vinogradov","year":"2013","unstructured":"Vinogradov, E., Dean Sherry, A. & Lenkinski, R. E. CEST: from basic principles to applications, challenges and opportunities. J. Magn. Reson. 229, 155\u2013172 (2013).","journal-title":"J. Magn. Reson."},{"key":"17598_CR12","doi-asserted-by":"crossref","first-page":"952","DOI":"10.1002\/(SICI)1522-2594(199911)42:5<952::AID-MRM16>3.0.CO;2-S","volume":"42","author":"KP Pruessmann","year":"1999","unstructured":"Pruessmann, K. P. et al. SENSE: sensitivity encoding for fast MRI. Magn. Reson. Med. 42, 952\u2013962 (1999).","journal-title":"Magn. Reson. Med."},{"key":"17598_CR13","doi-asserted-by":"crossref","first-page":"1202","DOI":"10.1002\/mrm.10171","volume":"47","author":"MA Griswold","year":"2002","unstructured":"Griswold, M. A. et al. Generalized autocalibrating partially parallel acquisitions (GRAPPA). Magn. Reson. Med. 47, 1202\u20131210 (2002).","journal-title":"Magn. Reson. Med."},{"key":"17598_CR14","doi-asserted-by":"crossref","first-page":"1182","DOI":"10.1002\/mrm.21391","volume":"58","author":"M Lustig","year":"2007","unstructured":"Lustig, M., Donoho, D. & Pauly, J. M. Sparse MRI: the application of compressed sensing for rapid MR imaging. Magn. Reson. Med. 58, 1182\u20131195 (2007).","journal-title":"Magn. Reson. Med."},{"key":"17598_CR15","doi-asserted-by":"crossref","first-page":"148","DOI":"10.1002\/cmr.a.20219","volume":"38A","author":"AG Webb","year":"2011","unstructured":"Webb, A. G. Dielectric materials in magnetic resonance. Concepts Magn. Reson. Part A 38A, 148\u2013184 (2011).","journal-title":"Concepts Magn. Reson. Part A"},{"key":"17598_CR16","doi-asserted-by":"crossref","first-page":"358","DOI":"10.1002\/mrm.22695","volume":"65","author":"QX Yang","year":"2011","unstructured":"Yang, Q. X. et al. Reducing SAR and enhancing cerebral signal-to-noise ratio with high permittivity padding at 3 T. Magn. Reson. Med. 65, 358\u2013362 (2011).","journal-title":"Magn. Reson. Med."},{"key":"17598_CR17","doi-asserted-by":"crossref","first-page":"1285","DOI":"10.1002\/mrm.23108","volume":"67","author":"WM Teeuwisse","year":"2012","unstructured":"Teeuwisse, W. M., Brink, W. M. & Webb, A. G. Quantitative assessment of the effects of high-permittivity pads in 7 Tesla MRI of the brain. Magn. Reson. Med. 67, 1285\u20131293 (2012).","journal-title":"Magn. Reson. Med."},{"key":"17598_CR18","doi-asserted-by":"crossref","first-page":"383","DOI":"10.1002\/mrm.26344","volume":"78","author":"Z Yu","year":"2017","unstructured":"Yu, Z., Xin, X. & Collins, C. M. Potential for high-permittivity materials to reduce local SAR at a pacemaker lead tip during MRI of the head with a body transmit coil at 3\u2009T. Magn. Reson. Med. 78, 383\u2013386 (2017).","journal-title":"Magn. Reson. Med."},{"key":"17598_CR19","doi-asserted-by":"crossref","first-page":"2842","DOI":"10.1002\/mrm.26943","volume":"79","author":"S Rupprecht","year":"2018","unstructured":"Rupprecht, S. et al. Improvements of transmit efficiency and receive sensitivity with Ultrahigh dielectric constant (uHDC) ceramics at 1.5 T and 3 T. Magn. Reson. Med. 79, 2842\u20132851 (2018).","journal-title":"Magn. Reson. Med."},{"key":"17598_CR20","doi-asserted-by":"crossref","first-page":"59","DOI":"10.1016\/j.jmr.2018.12.013","volume":"299","author":"I Zivkovic","year":"2019","unstructured":"Zivkovic, I. et al. High permittivity ceramics improve the transmit field and receive efficiency of a commercial extremity coil at 1.5 Tesla. J. Magn. Reson. 299, 59\u201365 (2019).","journal-title":"J. Magn. Reson."},{"key":"17598_CR21","doi-asserted-by":"crossref","first-page":"1753","DOI":"10.1002\/mrm.26771","volume":"79","author":"AL Neves","year":"2018","unstructured":"Neves, A. L. et al. Compressed perovskite aqueous mixtures near their phase transitions show very high permittivities: new prospects for high-field MRI dielectric shimming. Magn. Reson. Med. 79, 1753\u20131765 (2018).","journal-title":"Magn. Reson. Med."},{"key":"17598_CR22","doi-asserted-by":"crossref","first-page":"1900912","DOI":"10.1002\/adma.201900912","volume":"31","author":"MAC Moussu","year":"2019","unstructured":"Moussu, M. A. C. et al. Systematic analysis of the improvements in magnetic resonance microscopy with ferroelectric composite ceramics. Adv. Mater. 31, 1900912 (2019).","journal-title":"Adv. Mater."},{"key":"17598_CR23","doi-asserted-by":"crossref","first-page":"849","DOI":"10.1126\/science.291.5505.849","volume":"291","author":"MC Wiltshire","year":"2001","unstructured":"Wiltshire, M. C. et al. Microstructured magnetic materials for RF flux guides in magnetic resonance imaging. Science 291, 849\u2013851 (2001).","journal-title":"Science"},{"key":"17598_CR24","doi-asserted-by":"crossref","first-page":"81","DOI":"10.1016\/j.jmr.2009.12.005","volume":"203","author":"MJ Freire","year":"2010","unstructured":"Freire, M. J. et al. On the applications of \u00b5r=-1 metamaterial lenses for magnetic resonance imaging. J. Magn. Reson. 203, 81\u201390 (2010).","journal-title":"J. Magn. Reson."},{"key":"17598_CR25","first-page":"031083","volume":"8","author":"M Dubois","year":"2018","unstructured":"Dubois, M. et al. Kerker effect in ultrahigh-field magnetic resonance imaging. Phys. Rev. X 8, 031083 (2018).","journal-title":"Phys. Rev. X"},{"key":"17598_CR26","doi-asserted-by":"crossref","first-page":"34618","DOI":"10.1021\/acsami.7b06949","volume":"9","author":"R Schmidt","year":"2017","unstructured":"Schmidt, R. & Webb, A. Metamaterial combining electric- and magnetic-dipole-based configurations for unique dual-band signal enhancement in ultrahigh-field magnetic resonance imaging. ACS Appl. Mater. Interfaces 9, 34618\u201334624 (2017).","journal-title":"ACS Appl. Mater. Interfaces"},{"key":"17598_CR27","doi-asserted-by":"crossref","first-page":"1832","DOI":"10.1002\/adma.201504270","volume":"28","author":"AP Slobozhanyuk","year":"2016","unstructured":"Slobozhanyuk, A. P. et al. Enhancement of magnetic resonance imaging with metasurfaces. Adv. Mater. 28, 1832\u20131838 (2016).","journal-title":"Adv. Mater."},{"key":"17598_CR28","doi-asserted-by":"crossref","first-page":"aag2472","DOI":"10.1126\/science.aag2472","volume":"354","author":"AI Kuznetsov","year":"2016","unstructured":"Kuznetsov, A. I. et al. Optically resonant dielectric nanostructures. Science 354, aag2472 (2016).","journal-title":"Science"},{"key":"17598_CR29","doi-asserted-by":"crossref","first-page":"23","DOI":"10.1038\/nnano.2015.304","volume":"11","author":"S Jahani","year":"2016","unstructured":"Jahani, S. & Jacob, Z. All-dielectric metamaterials. Nat. Nanotechnol. 11, 23\u201336 (2016).","journal-title":"Nat. Nanotechnol."},{"key":"17598_CR30","doi-asserted-by":"crossref","DOI":"10.1038\/ncomms10362","volume":"7","author":"R Paniagua-Dom\u00ednguez","year":"2016","unstructured":"Paniagua-Dom\u00ednguez, R. et al. Generalized Brewster effect in dielectric metasurfaces. Nat. Commun. 7, 10362 (2016).","journal-title":"Nat. Commun."},{"key":"17598_CR31","doi-asserted-by":"crossref","first-page":"030801","DOI":"10.1063\/1.4949007","volume":"1","author":"S Kruk","year":"2016","unstructured":"Kruk, S. et al. Invited Article: broadband highly efficient dielectric metadevices for polarization control. APL Photonics 1, 030801 (2016).","journal-title":"APL Photonics"},{"key":"17598_CR32","doi-asserted-by":"crossref","first-page":"395","DOI":"10.1016\/j.jeurceramsoc.2009.04.008","volume":"30","author":"EA Nenasheva","year":"2010","unstructured":"Nenasheva, E. A. et al. Low loss microwave ferroelectric ceramics for high power tunable devices. J. Eur. Ceram. Soc. 30, 395\u2013400 (2010).","journal-title":"J. Eur. Ceram. Soc."},{"key":"17598_CR33","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1016\/j.pnmrs.2014.09.003","volume":"83","author":"A Webb","year":"2014","unstructured":"Webb, A. Cavity- and waveguide-resonators in electron paramagnetic resonance, nuclear magnetic resonance, and magnetic resonance imaging. Prog. Nucl. Magn. Reson. Spectrosc. 83, 1\u201320 (2014).","journal-title":"Prog. Nucl. Magn. Reson. Spectrosc."},{"key":"17598_CR34","doi-asserted-by":"crossref","DOI":"10.1002\/9781118633953","volume-title":"Magnetic Resonance Imaging: Physical Principles and Sequence Design","author":"RW Brown","year":"2014","unstructured":"Brown, R. W. et al. Magnetic Resonance Imaging: Physical Principles and Sequence Design. 2nd edn (Wiley Blackwell, New Jersey, 2014).","edition":"2nd edn"},{"key":"17598_CR35","doi-asserted-by":"crossref","first-page":"419","DOI":"10.1161\/CIRCEP.113.000116","volume":"6","author":"S Nazarian","year":"2013","unstructured":"Nazarian, S., Beinart, R. & Halperin, H. Magnetic resonance imaging and implantable devices. Circ. Arrhyth. Electrophysiol. 6, 419\u2013428 (2013).","journal-title":"Circ. Arrhyth. Electrophysiol."},{"key":"17598_CR36","doi-asserted-by":"crossref","first-page":"187ps9","DOI":"10.1126\/scitranslmed.3005686","volume":"5","author":"TE Yankeelov","year":"2013","unstructured":"Yankeelov, T. E. et al. Clinically relevant modeling of tumor growth and treatment response. Sci. Transl. Med. 5, 187ps9 (2013).","journal-title":"Sci. Transl. Med."},{"key":"17598_CR37","doi-asserted-by":"crossref","first-page":"873","DOI":"10.1007\/s00247-016-3560-8","volume":"46","author":"EA Smith","year":"2016","unstructured":"Smith, E. A. & Dillman, J. R. Current role of body MRI in pediatric oncology. Pediatr. Radiol. 46, 873\u2013880 (2016).","journal-title":"Pediatr. Radiol."},{"key":"17598_CR38","doi-asserted-by":"crossref","first-page":"348","DOI":"10.1038\/nature21369","volume":"542","author":"HC Hazlett","year":"2017","unstructured":"Hazlett, H. C. et al. Early brain development in infants at high risk for autism spectrum disorder. Nature 542, 348\u2013351 (2017).","journal-title":"Nature"},{"key":"17598_CR39","doi-asserted-by":"crossref","first-page":"363","DOI":"10.1055\/s-0035-1563735","volume":"19","author":"H Alizai","year":"2015","unstructured":"Alizai, H., Chang, G. & Regatte, R. MRI of the musculoskeletal system: advanced applications using high and ultrahigh field MRI. Semin. Musculoskelet. Radiol. 19, 363\u2013374 (2015).","journal-title":"Semin. Musculoskelet. Radiol."},{"key":"17598_CR40","doi-asserted-by":"crossref","first-page":"94","DOI":"10.1016\/j.jmr.2017.09.015","volume":"284","author":"T Ruytenberg","year":"2017","unstructured":"Ruytenberg, T. & Webb, A. G. Design of a dielectric resonator receive array at 7 Tesla using detunable ceramic resonators. J. Magn. Reson. 284, 94\u201398 (2017).","journal-title":"J. Magn. Reson."},{"key":"17598_CR41","doi-asserted-by":"crossref","first-page":"580","DOI":"10.1002\/mrm.23264","volume":"68","author":"IML van Kalleveen","year":"2012","unstructured":"van Kalleveen, I. M. L. et al. Adiabatic turbo spin echo in human applications at 7 T. Magn. Reson. Med. 68, 580\u2013587 (2012).","journal-title":"Magn. Reson. Med."},{"key":"17598_CR42","doi-asserted-by":"crossref","first-page":"187","DOI":"10.1038\/nature11971","volume":"495","author":"D Ma","year":"2013","unstructured":"Ma, D. et al. Magnetic resonance fingerprinting. Nature 495, 187\u2013192 (2013).","journal-title":"Nature"},{"key":"17598_CR43","doi-asserted-by":"crossref","DOI":"10.1038\/ncomms9069","volume":"6","author":"AE Miroshnichenko","year":"2015","unstructured":"Miroshnichenko, A. E. et al. Nonradiating anapole modes in dielectric nanoparticles. Nat. Commun. 6, 8069 (2015).","journal-title":"Nat. Commun."},{"key":"17598_CR44","doi-asserted-by":"crossref","first-page":"243901","DOI":"10.1103\/PhysRevLett.119.243901","volume":"119","author":"MV Rybin","year":"2017","unstructured":"Rybin, M. V. et al. High-Q supercavity modes in subwavelength dielectric resonators. Phys. Rev. Lett. 119, 243901 (2017).","journal-title":"Phys. Rev. Lett."}],"container-title":["Nature Communications"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.nature.com\/articles\/s41467-020-17598-3.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.nature.com\/articles\/s41467-020-17598-3","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.nature.com\/articles\/s41467-020-17598-3.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2022,12,5]],"date-time":"2022-12-05T19:13:24Z","timestamp":1670267604000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.nature.com\/articles\/s41467-020-17598-3"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2020,7,31]]},"references-count":44,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2020,12]]}},"alternative-id":["17598"],"URL":"https:\/\/doi.org\/10.1038\/s41467-020-17598-3","relation":{},"ISSN":["2041-1723"],"issn-type":[{"value":"2041-1723","type":"electronic"}],"subject":[],"published":{"date-parts":[[2020,7,31]]},"assertion":[{"value":"21 August 2019","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"25 June 2020","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"31 July 2020","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"A patent has been filed with the title \u201cCoil for magnetic resonance imaging of the breast\u201d (# 2018146803 (27.12.2018)).","order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"3840"}}