{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,26]],"date-time":"2026-08-26T19:25:25Z","timestamp":1787772325283,"version":"build-2784847793"},"reference-count":30,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2023,7,31]],"date-time":"2023-07-31T00:00:00Z","timestamp":1690761600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2023,7,31]],"date-time":"2023-07-31T00:00:00Z","timestamp":1690761600000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Nat Commun"],"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:p>Visible light optical elements such as lenses and mirrors have counterparts for X-rays. In the visible regime, a variable focusing power can be achieved by an Alvarez lens which consists of a pair of inline planar refractors with a cubic thickness profile. When the two refractors are laterally displaced in opposite directions, the parabolic component of the wavefront is changed resulting in a longitudinal displacement of the focus. This paper reports an implementation of this concept for X-rays using two planar microfabricated refractive elements. The Alvarez X-ray lens can vary the focal distance of an elliptical X-ray mirror or a planar compound X-ray lens over several millimetres. The study presents the first demonstration of an Alvarez X-ray lens which adaptively corrects defocus and astigmatism aberrations of X-ray optics. In addition, the Alvarez X-ray lens eliminates coma aberration in an elliptical mirror, to the lowest order, when combining the lens with an adjustment of the pitch angle of the mirror.<\/jats:p>","DOI":"10.1038\/s41467-023-40347-1","type":"journal-article","created":{"date-parts":[[2023,7,31]],"date-time":"2023-07-31T05:02:05Z","timestamp":1690779725000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":10,"title":["Alvarez varifocal X-ray lens"],"prefix":"10.1038","volume":"14","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-4919-8957","authenticated-orcid":false,"given":"Vishal","family":"Dhamgaye","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"David","family":"Laundy","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Hossein","family":"Khosroabadi","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Thomas","family":"Moxham","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-9635-7757","authenticated-orcid":false,"given":"Sara","family":"Baldock","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-5224-7062","authenticated-orcid":false,"given":"Oliver","family":"Fox","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-6593-7740","authenticated-orcid":false,"given":"Kawal","family":"Sawhney","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2023,7,31]]},"reference":[{"key":"40347_CR1","doi-asserted-by":"publisher","first-page":"837","DOI":"10.1107\/S1600577514019286","volume":"21","author":"M Eriksson","year":"2014","unstructured":"Eriksson, M., Van der Veen, J. F. & Quitmann, C. Diffraction-limited storage rings\u2013a window to the science of tomorrow. J. Synchrotron Radiat. 21, 837\u2013842 (2014).","journal-title":"J. Synchrotron Radiat."},{"key":"40347_CR2","doi-asserted-by":"publisher","first-page":"1234","DOI":"10.1126\/science.1202366","volume":"334","author":"GE Ice","year":"2011","unstructured":"Ice, G. E., Budai, J. D. & Pang, J. W. The race to x-ray microbeam and nanobeam science. Science 334, 1234\u20131239 (2011).","journal-title":"Science"},{"key":"40347_CR3","doi-asserted-by":"publisher","first-page":"025007","DOI":"10.1103\/RevModPhys.90.025007","volume":"90","author":"L Mino","year":"2018","unstructured":"Mino, L. et al. Materials characterization by synchrotron x-ray microprobes and nanoprobes. Rev. Mod. Phys. 90, 025007 (2018).","journal-title":"Rev. Mod. Phys."},{"key":"40347_CR4","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1016\/j.physrep.2022.05.001","volume":"974","author":"D Cocco","year":"2022","unstructured":"Cocco, D. et al. Wavefront preserving X-ray optics for Synchrotron and Free Electron Laser photon beam transport systems. Phys. Rep. 974, 1\u201340 (2022).","journal-title":"Phys. Rep."},{"key":"40347_CR5","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1038\/s41598-018-35611-0","volume":"8","author":"S Matsuyama","year":"2018","unstructured":"Matsuyama, S. et al. Nanofocusing of X-ray free-electron laser using wavefront-corrected multilayer focusing mirrors. Sci. Rep. 8, 1\u20131 (2018).","journal-title":"Sci. Rep."},{"key":"40347_CR6","doi-asserted-by":"publisher","first-page":"051904","DOI":"10.1063\/1.4960593","volume":"109","author":"K Sawhney","year":"2016","unstructured":"Sawhney, K., Laundy, D., Dhamgaye, V. & Pape, I. Compensation of X-ray mirror shape-errors using refractive optics. Appl. Phys. Lett. 109, 051904 (2016).","journal-title":"Appl. Phys. Lett."},{"key":"40347_CR7","doi-asserted-by":"publisher","first-page":"14623","DOI":"10.1038\/ncomms14623","volume":"8","author":"F Seiboth","year":"2017","unstructured":"Seiboth, F. et al. Perfect x-ray focusing via fitting corrective glasses to aberrated optics. Nat. Comm. 8, 14623 (2017).","journal-title":"Nat. Comm."},{"key":"40347_CR8","doi-asserted-by":"publisher","first-page":"766","DOI":"10.1364\/JOSA.38.000766","volume":"38","author":"P Kirkpatrick","year":"1948","unstructured":"Kirkpatrick, P. & Baez, A. V. Formation of optical images by X-rays. J. Opt. Soc. Am. 38, 766\u2013774 (1948).","journal-title":"J. Opt. Soc. Am."},{"key":"40347_CR9","doi-asserted-by":"publisher","first-page":"1518","DOI":"10.1107\/S1600577520011765","volume":"27","author":"V Dhamgaye","year":"2020","unstructured":"Dhamgaye, V., Laundy, D., Baldock, S., Moxham, T. & Sawhney, K. Correction of the X-ray wavefront from compound refractive lenses using 3D printed refractive structures. J. Synchrotron Radiat. 27, 1518\u20131527 (2020).","journal-title":"J. Synchrotron Radiat."},{"key":"40347_CR10","doi-asserted-by":"publisher","first-page":"125","DOI":"10.1107\/S0909049510044365","volume":"18","author":"GB Vaughan","year":"2011","unstructured":"Vaughan, G. B. et al. X-ray transfocators: focusing devices based on compound refractive lenses. J. Synchrotron Radiat. 18, 125\u2013133 (2011).","journal-title":"J. Synchrotron Radiat."},{"key":"40347_CR11","doi-asserted-by":"publisher","first-page":"22455","DOI":"10.1364\/OE.25.022455","volume":"25","author":"E Kornemann","year":"2017","unstructured":"Kornemann, E. et al. Miniaturized compound refractive X-ray zoom lens. Opt. Express 25, 22455\u201322466 (2017).","journal-title":"Opt. Express"},{"key":"40347_CR12","doi-asserted-by":"publisher","first-page":"1514","DOI":"10.1107\/S1600577518010603","volume":"25","author":"SM Heald","year":"2018","unstructured":"Heald, S. M. & Dufresne, E. M. Using refractive lenses to provide a variable spot size for Kirkpatrick\u2013Baez mirrors. J. Synchrotron Radiat. 25, 1514\u20131516 (2018).","journal-title":"J. Synchrotron Radiat."},{"key":"40347_CR13","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1038\/srep24801","volume":"6","author":"S Matsuyama","year":"2016","unstructured":"Matsuyama, S. et al. Nearly diffraction-limited X-ray focusing with variable-numerical-aperture focusing optical system based on four deformable mirrors. Sci. Rep. 6, 1\u20138 (2016).","journal-title":"Sci. Rep."},{"key":"40347_CR14","first-page":"66","volume":"11491","author":"X Shi","year":"2020","unstructured":"Shi, X. et al. Prototype design and experimental tests of a zoom mirror system for the APS upgrade. Adv. X-Ray\/EUV Opt. Compon. XV SPIE 11491, 66\u201373 (2020).","journal-title":"Adv. X-Ray\/EUV Opt. Compon. XV SPIE"},{"key":"40347_CR15","unstructured":"Alvarez, L. W. & Humphrey, W. E. Variable Power Lens and System. U.S. Patent 3,507,565 Optical Res. and Dev. Corp. (1970)."},{"key":"40347_CR16","first-page":"24","volume":"49","author":"LW Alvarez","year":"1978","unstructured":"Alvarez, L. W. Development of variable- focus lenses and a new refractor. J. Am. Optom. Assoc. 49, 24\u201329 (1978).","journal-title":"J. Am. Optom. Assoc."},{"key":"40347_CR17","unstructured":"Hecht, E. Optics (Addison-Wesley, 2001), 4th edition, page 168."},{"key":"40347_CR18","doi-asserted-by":"publisher","first-page":"708","DOI":"10.1107\/S0909049511026306","volume":"18","author":"M Sanchez del Rio","year":"2011","unstructured":"Sanchez del Rio, M., Canestrari, N., Jiang, F. & Cerrina, F. SHADOW3: a new version of the synchrotron X-ray optics modelling package. J. Synchrotron Radiat. 18, 708\u2013716 (2011).","journal-title":"J. Synchrotron Radiat."},{"key":"40347_CR19","doi-asserted-by":"publisher","first-page":"060081","DOI":"10.1063\/1.5084712","volume":"2054","author":"MSD Rio","year":"2019","unstructured":"Rio, M. S. D. & Rebuffi, L. OASYS: a software for beamline simulations and synchrotron virtual experiments. AIP Conf. Proc. 2054, 060081 (2019).","journal-title":"AIP Conf. Proc."},{"key":"40347_CR20","doi-asserted-by":"publisher","first-page":"1484","DOI":"10.1364\/OPTICA.6.001484","volume":"6","author":"D Laundy","year":"2019","unstructured":"Laundy, D., Dhamgaye, V., Moxham, T. & Sawhney, K. Adaptable refractive correctors for x-ray optics. Optica 6, 1484\u20131490 (2019).","journal-title":"Optica"},{"key":"40347_CR21","unstructured":"Born, M., & Wolf, E. Principles of Optics. (Cambridge University Press, 1999)."},{"key":"40347_CR22","first-page":"368","volume":"8141","author":"MS del R\u00edo","year":"2011","unstructured":"del R\u00edo, M. S. & Dejus, R. J. XOP v2. 4: recent developments of the x-ray optics software toolkit. Adv. Comput. Methods X-Ray Opt. II 8141, 368\u2013372 (2011).","journal-title":"Adv. Comput. Methods X-Ray Opt. II"},{"key":"40347_CR23","doi-asserted-by":"publisher","first-page":"714","DOI":"10.1107\/S1600577519001656","volume":"26","author":"A Barannikov","year":"2019","unstructured":"Barannikov, A. et al. Optical performance and radiation stability of polymer X-ray refractive nano-lenses. J. Synchrotron Radiat. 26, 714\u2013719 (2019).","journal-title":"J. Synchrotron Radiat."},{"key":"40347_CR24","doi-asserted-by":"publisher","first-page":"387","DOI":"10.1063\/1.3463220","volume":"1234","author":"KJS Sawhney","year":"2010","unstructured":"Sawhney, K. J. S. et al. A test beamline on diamond light source. AIP Conf. Proc. 1234, 387\u2013390 (2010).","journal-title":"AIP Conf. Proc."},{"key":"40347_CR25","doi-asserted-by":"publisher","first-page":"221104","DOI":"10.1063\/1.3665063","volume":"99","author":"S Rutishauser","year":"2011","unstructured":"Rutishauser, S., Zanette, I., Weitkamp, T., Donath, T. & David, C. At-wavelength characterization of refractive x-ray lenses using a two-dimensional grating interferometer. Appl. Phys. Lett. 99, 221104 (2011).","journal-title":"Appl. Phys. Lett."},{"key":"40347_CR26","doi-asserted-by":"publisher","first-page":"23310","DOI":"10.1364\/OE.23.023310","volume":"23","author":"H Wang","year":"2015","unstructured":"Wang, H., Kashyap, Y. & Sawhney, K. Speckle based X-ray wavefront sensing with nanoradian angular sensitivity. Opt. Express 23, 23310 (2015).","journal-title":"Opt. Express"},{"key":"40347_CR27","doi-asserted-by":"publisher","first-page":"32","DOI":"10.1080\/08940886.2016.1198674","volume":"29","author":"T Goto","year":"2016","unstructured":"Goto, T. et al. Simulation and experimental study of wavefront measurement accuracy of the pencil-beam method. Synchrotron Radiat. News 29, 32\u201336 (2016).","journal-title":"Synchrotron Radiat. News"},{"key":"40347_CR28","doi-asserted-by":"publisher","first-page":"23420","DOI":"10.1364\/OE.18.023420","volume":"18","author":"CM Kewish","year":"2010","unstructured":"Kewish, C. M. et al. Reconstruction of an astigmatic hard x-ray beam and alignment of k-b mirrors from ptychographic coherent diffraction data. Opt. Express 18, 23420\u201323427 (2010).","journal-title":"Opt. Express"},{"key":"40347_CR29","doi-asserted-by":"publisher","first-page":"26961","DOI":"10.1364\/OE.26.026961","volume":"26","author":"T Zhou","year":"2018","unstructured":"Zhou, T., Wang, H., Fox, O. & Sawhney, K. Auto-alignment of X-ray focusing mirrors with speckle-based at-wavelength metrology. Opt. Express 26, 26961\u201326970 (2018).","journal-title":"Opt. Express"},{"key":"40347_CR30","doi-asserted-by":"publisher","first-page":"104104","DOI":"10.1063\/5.0041341","volume":"118","author":"TE Moxham","year":"2021","unstructured":"Moxham, T. E. et al. Aberration characterization of x-ray optics using multi-modal ptychography and a partially coherent source. Appl. Phys. Lett. 118, 104104 (2021).","journal-title":"Appl. Phys. Lett."}],"container-title":["Nature Communications"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.nature.com\/articles\/s41467-023-40347-1.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.nature.com\/articles\/s41467-023-40347-1","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.nature.com\/articles\/s41467-023-40347-1.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,7,31]],"date-time":"2023-07-31T05:03:04Z","timestamp":1690779784000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.nature.com\/articles\/s41467-023-40347-1"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2023,7,31]]},"references-count":30,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2023,12]]}},"alternative-id":["40347"],"URL":"https:\/\/doi.org\/10.1038\/s41467-023-40347-1","relation":{"has-preprint":[{"id-type":"doi","id":"10.21203\/rs.3.rs-1825147\/v1","asserted-by":"object"}]},"ISSN":["2041-1723"],"issn-type":[{"value":"2041-1723","type":"electronic"}],"subject":[],"published":{"date-parts":[[2023,7,31]]},"assertion":[{"value":"4 July 2022","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"12 July 2023","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"31 July 2023","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"The authors declare no competing interests.","order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"4582"}}