{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,11,7]],"date-time":"2026-11-07T04:42:15Z","timestamp":1794026535191,"version":"4.8.0"},"reference-count":85,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2025,3,22]],"date-time":"2025-03-22T00:00:00Z","timestamp":1742601600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2025,3,22]],"date-time":"2025-03-22T00:00:00Z","timestamp":1742601600000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"funder":[{"DOI":"10.13039\/501100005380","name":"Federal Department of the Environment, Transport, Energy, and Communications | Bundesamt f\u00fcr Energie","doi-asserted-by":"publisher","award":["SI\/502257"],"award-info":[{"award-number":["SI\/502257"]}],"id":[{"id":"10.13039\/501100005380","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Nat Commun"],"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:p>As heat pumps become more prevalent in residential buildings, effective performance monitoring is essential. Design flaws, incorrect settings, and faults can escalate energy consumption and costs, leading to discrepancies in user expectations and hindering the widespread adoption of this technology crucial for the heating transition. However, field studies using large data sets to offer insights into real-world performance and methods for identifying low-performing systems in practical, scalable applications are lacking. In the largest field study to date, we analyze sensor data from 1023 heat pumps across Central Europe monitored over two years. Based on existing approaches for controlled laboratory conditions, we derive methods to evaluate and classify real-world performance using operational data. Applying these methods, we find that 17% of air-source and 2% of ground-source heat pumps do not meet existing efficiency standards. Additionally, around 10% of systems are oversized, while approximately 1% are undersized. This underscores the need for standardized post-installation performance evaluation procedures and digital tools to provide actionable feedback for users and installers to enhance operational efficiency and guide future installations.<\/jats:p>","DOI":"10.1038\/s41467-025-58014-y","type":"journal-article","created":{"date-parts":[[2025,3,22]],"date-time":"2025-03-22T09:56:19Z","timestamp":1742637379000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":56,"title":["Estimation of energy efficiency of heat pumps in residential buildings using real operation data"],"prefix":"10.1038","volume":"16","author":[{"ORCID":"https:\/\/orcid.org\/0009-0007-7319-1142","authenticated-orcid":false,"given":"Tobias","family":"Brudermueller","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0009-0007-8495-2971","authenticated-orcid":false,"given":"Ugne","family":"Potthoff","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-4842-1117","authenticated-orcid":false,"given":"Elgar","family":"Fleisch","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-5034-2023","authenticated-orcid":false,"given":"Felix","family":"Wortmann","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-1399-4676","authenticated-orcid":false,"given":"Thorsten","family":"Staake","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2025,3,22]]},"reference":[{"key":"58014_CR1","unstructured":"International Energy Agency (IEA). Heat pumps. https:\/\/www.iea.org\/energy-system\/buildings\/heat-pumps (International Energy Agency (IEA), Paris, 2023)."},{"key":"58014_CR2","doi-asserted-by":"publisher","first-page":"104967","DOI":"10.1016\/j.eneco.2020.104967","volume":"92","author":"O Ruhnau","year":"2020","unstructured":"Ruhnau, O., Hirth, L. & Praktiknjo, A. Heating with wind: economics of heat pumps and variable renewables. Energy Econ. 92, 104967 (2020).","journal-title":"Energy Econ."},{"key":"58014_CR3","unstructured":"International Energy Agency (IEA). Heating. https:\/\/www.iea.org\/energy-system\/buildings\/heating (International Energy Agency (IEA), Paris, 2023)."},{"key":"58014_CR4","doi-asserted-by":"publisher","first-page":"901","DOI":"10.1038\/s41560-022-01104-8","volume":"7","author":"J Rosenow","year":"2022","unstructured":"Rosenow, J., Gibb, D., Nowak, T. & Lowes, R. Heating up the global heat pump market. Nat. Energy 7, 901\u2013904 (2022).","journal-title":"Nat. Energy"},{"key":"58014_CR5","doi-asserted-by":"publisher","first-page":"235","DOI":"10.1016\/j.enpol.2016.03.041","volume":"94","author":"K Bauermann","year":"2016","unstructured":"Bauermann, K. German Energiewende and the heating market\u2013impact and limits of policy. Energy Policy 94, 235\u2013246 (2016).","journal-title":"Energy Policy"},{"key":"58014_CR6","doi-asserted-by":"publisher","first-page":"530","DOI":"10.1016\/j.apenergy.2014.04.111","volume":"131","author":"A Pensini","year":"2014","unstructured":"Pensini, A., Rasmussen, C. N. & Kempton, W. Economic analysis of using excess renewable electricity to displace heating fuels. Appl. Energy 131, 530\u2013543 (2014).","journal-title":"Appl. Energy"},{"key":"58014_CR7","doi-asserted-by":"publisher","first-page":"103255","DOI":"10.1016\/j.erss.2023.103255","volume":"104","author":"M Poblete-Cazenave","year":"2023","unstructured":"Poblete-Cazenave, M. & Rao, N. D. Social and contextual determinants of heat pump adoption in the US: implications for subsidy policy design. Energy Res. Soc. Sci. 104, 103255 (2023).","journal-title":"Energy Res. Soc. Sci."},{"key":"58014_CR8","first-page":"100009","volume":"1","author":"S Kokoni","year":"2021","unstructured":"Kokoni, S. & Leach, M. Policy mechanisms to support heat pump deployment: a UK case study based on techno-economic modelling. Renew. Sustain. Energy Transit. 1, 100009 (2021).","journal-title":"Renew. Sustain. Energy Transit."},{"key":"58014_CR9","doi-asserted-by":"crossref","unstructured":"Tanil, G. et al. Political and Public Perceptions, 85\u2013111 (Springer International Publishing, Cham, 2023).","DOI":"10.1007\/978-3-031-28065-8_5"},{"key":"58014_CR10","first-page":"10","volume":"37","author":"KC Engelen","year":"2023","unstructured":"Engelen, K. C. Heat pump fiasco. Int. Econ. 37, 10\u201313 (2023).","journal-title":"Int. Econ."},{"key":"58014_CR11","doi-asserted-by":"publisher","first-page":"1127","DOI":"10.1016\/j.renene.2006.04.014","volume":"32","author":"M Nast","year":"2007","unstructured":"Nast, M., Langni\u00df, O. & Leprich, U. Instruments to promote renewable energy in the German heat market-renewable heat sources act. Renew. Energy 32, 1127\u20131135 (2007).","journal-title":"Renew. Energy"},{"key":"58014_CR12","doi-asserted-by":"publisher","first-page":"150","DOI":"10.1016\/j.enpol.2015.06.004","volume":"85","author":"T Decker","year":"2015","unstructured":"Decker, T. & Menrad, K. House owners\u2019 perceptions and factors influencing their choice of specific heating systems in Germany. Energy Policy 85, 150\u2013161 (2015).","journal-title":"Energy Policy"},{"key":"58014_CR13","doi-asserted-by":"publisher","first-page":"70","DOI":"10.1186\/s42162-022-00250-3","volume":"5","author":"A Weigert","year":"2022","unstructured":"Weigert, A. Identification and classification of heat pump problems in the field and their implication for a user-centric problem recognition. Energy Inform. 5, 70 (2022).","journal-title":"Energy Inform."},{"key":"58014_CR14","doi-asserted-by":"publisher","first-page":"121734","DOI":"10.1016\/j.apenergy.2023.121734","volume":"350","author":"T Brudermueller","year":"2023","unstructured":"Brudermueller, T., Kreft, M., Fleisch, E. & Staake, T. Large-scale monitoring of residential heat pump cycling using smart meter data. Appl. Energy 350, 121734 (2023).","journal-title":"Appl. Energy"},{"key":"58014_CR15","doi-asserted-by":"publisher","first-page":"476","DOI":"10.1016\/j.jobe.2018.02.013","volume":"18","author":"L Nolting","year":"2018","unstructured":"Nolting, L., Steiger, S. & Praktiknjo, A. Assessing the validity of European labels for energy efficiency of heat pumps. J. Build. Eng. 18, 476\u2013486 (2018).","journal-title":"J. Build. Eng."},{"key":"58014_CR16","doi-asserted-by":"publisher","first-page":"371","DOI":"10.1080\/09613218.2016.1159484","volume":"45","author":"MS Faye Wade","year":"2017","unstructured":"Faye Wade, M. S. & Hitchings, R. How installers select and explain domestic heating controls. Build. Res. Inf. 45, 371\u2013383 (2017).","journal-title":"Build. Res. Inf."},{"key":"58014_CR17","unstructured":"Tejeda, A., Milu, A., Riviere, P. & Marchio, D. Energy consequences of non-optimal heat pump parameterization. In International High Performance Buildings Conference. https:\/\/docs.lib.purdue.edu\/ihpbc\/110\/ (2014)."},{"key":"58014_CR18","doi-asserted-by":"publisher","first-page":"113156","DOI":"10.1016\/j.enpol.2022.113156","volume":"169","author":"A Weigert","year":"2022","unstructured":"Weigert, A., Hopf, K., G\u00fcnther, S. A. & Staake, T. Heat pump inspections result in large energy savings when a pre-selection of households is performed: a promising use case of smart meter data. Energy Policy 169, 113156 (2022).","journal-title":"Energy Policy"},{"key":"58014_CR19","doi-asserted-by":"publisher","first-page":"112561","DOI":"10.1016\/j.enbuild.2022.112561","volume":"277","author":"M Ryland","year":"2022","unstructured":"Ryland, M. & He, W. Heating economics evaluated against emissions: an analysis of low-carbon heating systems with spatiotemporal and dwelling variations. Energy Build. 277, 112561 (2022).","journal-title":"Energy Build."},{"key":"58014_CR20","doi-asserted-by":"publisher","first-page":"1025","DOI":"10.3390\/en15031025","volume":"15","author":"A Shah","year":"2022","unstructured":"Shah, A., Krarti, M. & Huang, J. Energy performance evaluation of shallow ground source heat pumps for residential buildings. Energies 15, 1025 (2022).","journal-title":"Energies"},{"key":"58014_CR21","first-page":"102829","volume":"54","author":"H Sadeghi","year":"2022","unstructured":"Sadeghi, H., Ijaz, A. & Singh, R. M. Current status of heat pumps in Norway and analysis of their performance and payback time. Sustain. Energy Technol. Assess. 54, 102829 (2022).","journal-title":"Sustain. Energy Technol. Assess."},{"key":"58014_CR22","doi-asserted-by":"publisher","first-page":"283","DOI":"10.1007\/s12053-012-9146-x","volume":"5","author":"S Caird","year":"2012","unstructured":"Caird, S., Roy, R. & Potter, S. Domestic heat pumps in the UK: user behaviour, satisfaction and performance. Energy Efficiency 5, 283\u2013301 (2012).","journal-title":"Energy Efficiency"},{"key":"58014_CR23","doi-asserted-by":"publisher","first-page":"836","DOI":"10.1016\/j.apenergy.2019.01.202","volume":"239","author":"F M\u00fcller","year":"2019","unstructured":"M\u00fcller, F. & Jansen, B. Large-scale demonstration of precise demand response provided by residential heat pumps. Appl. Energy 239, 836\u2013845 (2019).","journal-title":"Appl. Energy"},{"key":"58014_CR24","doi-asserted-by":"publisher","first-page":"011007","DOI":"10.1115\/1.4045819","volume":"1","author":"ZE Lee","year":"2020","unstructured":"Lee, Z. E. et al. Providing grid services with heat pumps: a review. ASME J. Eng. Sustain. Build. Cities 1, 011007 (2020).","journal-title":"ASME J. Eng. Sustain. Build. Cities"},{"key":"58014_CR25","doi-asserted-by":"publisher","first-page":"125298","DOI":"10.1016\/j.energy.2022.125298","volume":"262","author":"J Lizana","year":"2023","unstructured":"Lizana, J. et al. A national data-based energy modelling to identify optimal heat storage capacity to support heating electrification. Energy 262, 125298 (2023).","journal-title":"Energy"},{"key":"58014_CR26","doi-asserted-by":"publisher","first-page":"332","DOI":"10.1016\/j.apenergy.2017.07.026","volume":"204","author":"J Love","year":"2017","unstructured":"Love, J. et al. The addition of heat pump electricity load profiles to GB electricity demand: evidence from a heat pump field trial. Appl. Energy 204, 332\u2013342 (2017).","journal-title":"Appl. Energy"},{"key":"58014_CR27","doi-asserted-by":"publisher","first-page":"122331","DOI":"10.1016\/j.apenergy.2023.122331","volume":"355","author":"C Halloran","year":"2024","unstructured":"Halloran, C., Lizana, J., Fele, F. & McCulloch, M. Data-based, high spatiotemporal resolution heat pump demand for power system planning. Appl. Energy 355, 122331 (2024).","journal-title":"Appl. Energy"},{"key":"58014_CR28","doi-asserted-by":"publisher","first-page":"112917","DOI":"10.1016\/j.enbuild.2023.112917","volume":"286","author":"S Watson","year":"2023","unstructured":"Watson, S., Crawley, J., Lomas, K. & Buswell, R. Predicting future GB heat pump electricity demand. Energy Build. 286, 112917 (2023).","journal-title":"Energy Build."},{"key":"58014_CR29","doi-asserted-by":"publisher","first-page":"112696","DOI":"10.1016\/j.rser.2022.112696","volume":"167","author":"A Rinaldi","year":"2022","unstructured":"Rinaldi, A., Yilmaz, S., Patel, M. K. & Parra, D. What adds more flexibility? an energy system analysis of storage, demand-side response, heating electrification, and distribution reinforcement. Renew. Sustain. Energy Rev. 167, 112696 (2022).","journal-title":"Renew. Sustain. Energy Rev."},{"key":"58014_CR30","doi-asserted-by":"publisher","first-page":"268","DOI":"10.1016\/j.apenergy.2016.11.103","volume":"192","author":"C Protopapadaki","year":"2017","unstructured":"Protopapadaki, C. & Saelens, D. Heat pump and PV impact on residential low-voltage distribution grids as a function of building and district properties. Appl. Energy 192, 268\u2013281 (2017).","journal-title":"Appl. Energy"},{"key":"58014_CR31","doi-asserted-by":"publisher","first-page":"116875","DOI":"10.1016\/j.energy.2019.116875","volume":"196","author":"O Terreros","year":"2020","unstructured":"Terreros, O. et al. Electricity market options for heat pumps in rural district heating networks in Austria. Energy 196, 116875 (2020).","journal-title":"Energy"},{"key":"58014_CR32","doi-asserted-by":"publisher","first-page":"100389","DOI":"10.1016\/j.esr.2019.100389","volume":"26","author":"C Bernath","year":"2019","unstructured":"Bernath, C., Deac, G. & Sensfu\u00df, F. Influence of heat pumps on renewable electricity integration: Germany in a European context. Energy Strategy Rev. 26, 100389 (2019).","journal-title":"Energy Strategy Rev."},{"key":"58014_CR33","unstructured":"International Energy Agency - Technology Collaboration Programme on Heat Pumping Technology (IEA - HPT TCP). Annex 56 on digitalization and IoT for heat pumps. https:\/\/heatpumpingtechnologies.org\/annex56\/ (2023)."},{"key":"58014_CR34","doi-asserted-by":"publisher","first-page":"6031","DOI":"10.3390\/su12156031","volume":"12","author":"SPAK Larsen","year":"2020","unstructured":"Larsen, S. P. A. K. & Gram-Hanssen, K. When space heating becomes digitalized: investigating competencies for controlling smart home technology in the energy-efficient home. Sustainability 12, 6031 (2020).","journal-title":"Sustainability"},{"key":"58014_CR35","doi-asserted-by":"publisher","first-page":"116769","DOI":"10.1016\/j.enconman.2023.116769","volume":"279","author":"Y Song","year":"2023","unstructured":"Song, Y., Rolando, D., Marchante Avellaneda, J., Zucker, G. & Madani, H. Data-driven soft sensors targeting heat pump systems. Energy Convers. Manag. 279, 116769 (2023).","journal-title":"Energy Convers. Manag."},{"key":"58014_CR36","doi-asserted-by":"publisher","first-page":"102254","DOI":"10.1016\/j.jobe.2021.102254","volume":"39","author":"I Bellanco","year":"2021","unstructured":"Bellanco, I., Fuentes, E., Vall\u00e8s, M. & Salom, J. A review of the fault behavior of heat pumps and measurements, detection and diagnosis methods including virtual sensors. J. Build. Eng. 39, 102254 (2021).","journal-title":"J. Build. Eng."},{"key":"58014_CR37","doi-asserted-by":"publisher","first-page":"110275","DOI":"10.1016\/j.rser.2020.110275","volume":"134","author":"P Carroll","year":"2020","unstructured":"Carroll, P., Chesser, M. & Lyons, P. Air source heat pumps field studies: a systematic literature review. Renew. Sustain. Energy Rev. 134, 110275 (2020).","journal-title":"Renew. Sustain. Energy Rev."},{"key":"58014_CR38","doi-asserted-by":"publisher","first-page":"100","DOI":"10.1016\/j.buildenv.2012.01.013","volume":"53","author":"K Huchtemann","year":"2012","unstructured":"Huchtemann, K. & M\u00fcller, D. Evaluation of a field test with retrofit heat pumps. Build. Environ. 53, 100\u2013106 (2012).","journal-title":"Build. Environ."},{"key":"58014_CR39","unstructured":"Lowe, R. et al. Final report on analysis of heat pump data from the Renewable Heat Premium Payment (RHPP) scheme. https:\/\/assets.publishing.service.gov.uk\/media\/5a82b8faed915d74e62374d8\/DECC_RHPP_161214_Final_Report_v1-13.pdf (2017)."},{"key":"58014_CR40","unstructured":"Miara, M., G\u00fcnther, D., Langner, R., Helmling, S. & Wapler, J. 10 years of heat pumps monitoring in Germany. outcomes of several monitoring campaigns. from low-energy houses to un-retrofitted single-family dwellings. In 12th IEA Heat Pump Conference, 11 (2017)."},{"key":"58014_CR41","doi-asserted-by":"publisher","first-page":"111887","DOI":"10.1016\/j.rser.2021.111887","volume":"155","author":"R O\u2019Hegarty","year":"2022","unstructured":"O\u2019Hegarty, R., Kinnane, O., Lennon, D. & Colclough, S. Air-to-water heat pumps: review and analysis of the performance gap between in-use and product rated performance. Renew. Sustain. Energy Rev. 155, 111887 (2022).","journal-title":"Renew. Sustain. Energy Rev."},{"key":"58014_CR42","doi-asserted-by":"publisher","first-page":"2300379","DOI":"10.1002\/ente.202300379","volume":"11","author":"M L\u00e4mmle","year":"2023","unstructured":"L\u00e4mmle, M. et al. Heat pump systems in existing multifamily buildings: a meta-analysis of field measurement data focusing on the relationship of temperature and performance of heat pump systems. Energy Technol. 11, 2300379 (2023).","journal-title":"Energy Technol."},{"key":"58014_CR43","doi-asserted-by":"publisher","first-page":"172","DOI":"10.1016\/j.enbuild.2018.10.014","volume":"182","author":"J Deng","year":"2019","unstructured":"Deng, J., Wei, Q., Liang, M., He, S. & Zhang, H. Does heat pumps perform energy efficiently as we expected: field tests and evaluations on various kinds of heat pump systems for space heating. Energy Build. 182, 172\u2013186 (2019).","journal-title":"Energy Build."},{"key":"58014_CR44","doi-asserted-by":"publisher","first-page":"829","DOI":"10.1016\/j.renene.2021.08.130","volume":"180","author":"X Sun","year":"2021","unstructured":"Sun, X. et al. Seasonal heating performance prediction of air-to-water heat pumps based on short-term dynamic monitoring. Renew. Energy 180, 829\u2013837 (2021).","journal-title":"Renew. Energy"},{"key":"58014_CR45","doi-asserted-by":"publisher","first-page":"102446","DOI":"10.1016\/j.jobe.2021.102446","volume":"41","author":"B Gao","year":"2021","unstructured":"Gao, B. et al. Operation performance test and energy efficiency analysis of ground-source heat pump systems. J. Build. Eng. 41, 102446 (2021).","journal-title":"J. Build. Eng."},{"key":"58014_CR46","doi-asserted-by":"publisher","first-page":"129537","DOI":"10.1016\/j.energy.2023.129537","volume":"285","author":"J Deng","year":"2023","unstructured":"Deng, J. et al. How to improve the energy performance of mid-deep geothermal heat pump systems: optimization of heat pump, system configuration and control strategy. Energy 285, 129537 (2023).","journal-title":"Energy"},{"key":"58014_CR47","first-page":"101255","volume":"46","author":"X Zhou","year":"2021","unstructured":"Zhou, X., Lin, W., Cui, P., Ma, Z. & Huang, T. An unsupervised data mining strategy for performance evaluation of ground source heat pump systems. Sustain. Energy Technol. Assess. 46, 101255 (2021).","journal-title":"Sustain. Energy Technol. Assess."},{"key":"58014_CR48","doi-asserted-by":"publisher","first-page":"111685","DOI":"10.1016\/j.rser.2021.111685","volume":"153","author":"S Noye","year":"2022","unstructured":"Noye, S., Mulero Martinez, R., Carnieletto, L., De Carli, M. & Castelruiz Aguirre, A. A review of advanced ground source heat pump control: Artificial intelligence for autonomous and adaptive control. Renew. Sustain. Energy Rev. 153, 111685 (2022).","journal-title":"Renew. Sustain. Energy Rev."},{"key":"58014_CR49","doi-asserted-by":"publisher","first-page":"1417","DOI":"10.1016\/j.apenergy.2019.01.177","volume":"238","author":"L Nolting","year":"2019","unstructured":"Nolting, L. & Praktiknjo, A. Techno-economic analysis of flexible heat pump controls. Appl. Energy 238, 1417\u20131433 (2019).","journal-title":"Appl. Energy"},{"key":"58014_CR50","unstructured":"European Standard EN 14825. Air conditioners, liquid chilling packages and heat pumps, with electrically driven compressors, for space heating and cooling, commercial and process cooling\u2013testing and rating at part load conditions and calculation of seasonal performance; German version EN 14825:2022 (2022)."},{"key":"58014_CR51","unstructured":"Nordman, R. et al. SEasonal PErformance factor and MOnitoring for heat pump systems in the building sector SEPEMO-Build: Final report. (Intelligent Energy Europe 2012)."},{"key":"58014_CR52","unstructured":"Norwegian Ministry of Energy. The Norwegian Water Resources and Energy Directorate (NVE). [XXX\/XXXX] Ecodesign regulation space \/ combination heaters COMMISSION REGULATION (EU) No [XXX\/XXXX] of [XX\/XX\/XXXX] implementing Directive 2009\/125\/EC of the European Parliament and of the Council with regard to ecodesign requirements for space heaters and combination heaters, repealing Commission Regulation (EU) No 813\/2013 and Council Directive 92\/42\/EEC. https:\/\/www.nve.no\/media\/15330\/space-heaters_ed_27032023.pdf (2023)."},{"key":"58014_CR53","doi-asserted-by":"publisher","first-page":"9291","DOI":"10.1039\/c2ee22653g","volume":"5","author":"I Staffell","year":"2012","unstructured":"Staffell, I., Brett, D., Brandon, N. & Hawkes, A. A review of domestic heat pumps. Energy Environ. Sci. 5, 9291\u20139306 (2012).","journal-title":"Energy Environ. Sci."},{"key":"58014_CR54","doi-asserted-by":"publisher","DOI":"10.1038\/ncomms5721","volume":"5","author":"G Verley","year":"2014","unstructured":"Verley, G., Esposito, M., Willaert, T. & Van den Broeck, C. The unlikely carnot efficiency. Nat. Commun. 5, 4721 (2014).","journal-title":"Nat. Commun."},{"key":"58014_CR55","doi-asserted-by":"crossref","unstructured":"O\u2019Donovan, A. & O\u2019Sullivan, P. In-use performance of air-to-water heat pumps: are the standards robust? In E3S Web of Conferences, 246, 06002 (EDP Sciences, 2021).","DOI":"10.1051\/e3sconf\/202124606002"},{"key":"58014_CR56","doi-asserted-by":"crossref","unstructured":"Brudermueller, T., Wirth, F., Weigert, A. & Staake, T. Automatic differentiation of variable and fixed speed heat pumps with smart meter data. In 2022 IEEE International Conference on Communications, Control, and Computing Technologies for Smart Grids (SmartGridComm), 412\u2013418 (2022).","DOI":"10.1109\/SmartGridComm52983.2022.9961055"},{"key":"58014_CR57","doi-asserted-by":"publisher","first-page":"114490","DOI":"10.1016\/j.enbuild.2024.114490","volume":"318","author":"A Rogeau","year":"2024","unstructured":"Rogeau, A., Vieubled, J., Ruche, L. & Girard, R. A generic methodology for mapping the performance of various heat pumps configurations considering part-load behavior. Energy Build. 318, 114490 (2024).","journal-title":"Energy Build."},{"key":"58014_CR58","doi-asserted-by":"publisher","first-page":"542","DOI":"10.3390\/cleantechnol4020033","volume":"4","author":"J Sieres","year":"2022","unstructured":"Sieres, J., Ortega, I., Cerdeira, F., \u00c1lvarez, E. & Santos, J. M. Seasonal efficiency of a brine-to-water heat pump with different control options according to ecodesign standards. Clean. Technol. 4, 542\u2013554 (2022).","journal-title":"Clean. Technol."},{"key":"58014_CR59","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1038\/s41597-019-0199-y","volume":"6","author":"O Ruhnau","year":"2019","unstructured":"Ruhnau, O., Hirth, L. & Praktiknjo, A. Time series of heat demand and heat pump efficiency for energy system modeling. Sci. Data 6, 1\u201310 (2019).","journal-title":"Sci. Data"},{"key":"58014_CR60","doi-asserted-by":"publisher","first-page":"1045","DOI":"10.3390\/en12061045","volume":"12","author":"C Palkowski","year":"2019","unstructured":"Palkowski, C., Zottl, A., Malenkovic, I. & Simo, A. Fixing efficiency values by unfixing compressor speed: dynamic test method for heat pumps. Energies 12, 1045 (2019).","journal-title":"Energies"},{"key":"58014_CR61","doi-asserted-by":"publisher","first-page":"853","DOI":"10.1016\/j.energy.2016.10.111","volume":"118","author":"D Fischer","year":"2017","unstructured":"Fischer, D., Wolf, T., Wapler, J., Hollinger, R. & Madani, H. Model-based flexibility assessment of a residential heat pump pool. Energy 118, 853\u2013864 (2017).","journal-title":"Energy"},{"key":"58014_CR62","doi-asserted-by":"publisher","first-page":"415","DOI":"10.1016\/j.energy.2018.04.131","volume":"154","author":"J Posp\u00ed\u0161il","year":"2018","unstructured":"Posp\u00ed\u0161il, J., \u0160pil\u00e1\u010dek, M. & Kudela, L. Potential of predictive control for improvement of seasonal coefficient of performance of air source heat pump in Central European climate zone. Energy 154, 415\u2013423 (2018).","journal-title":"Energy"},{"key":"58014_CR63","doi-asserted-by":"publisher","first-page":"69","DOI":"10.1080\/14786451.2020.1794864","volume":"40","author":"GA Mouzeviris","year":"2021","unstructured":"Mouzeviris, G. A. & Papakostas, K. T. Comparative analysis of air-to-water and ground source heat pumps performances. Int. J. Sustain. Energy 40, 69\u201384 (2021).","journal-title":"Int. J. Sustain. Energy"},{"key":"58014_CR64","doi-asserted-by":"publisher","first-page":"1029","DOI":"10.1016\/j.renene.2022.02.075","volume":"188","author":"AC Violante","year":"2022","unstructured":"Violante, A. C., Donato, F., Guidi, G. & Proposito, M. Comparative life cycle assessment of the ground source heat pump vs air source heat pump. Renew. Energy 188, 1029\u20131037 (2022).","journal-title":"Renew. Energy"},{"key":"58014_CR65","unstructured":"The European Commission. Commission Delegated Regulation (Eu) No 811\/2013 Of 18 February 2013 Supplementing Directive 2010\/30\/eu Of The European Parliament And Of The Council With Regard To The Energy Labelling Of Space Heaters, Combination Heaters, Packages Of Space Heater, Temperature Control And Solar Device And Packages Of Combination Heater, Temperature Control And Solar Device. https:\/\/eur-lex.europa.eu\/legal-content\/EN\/TXT\/?uri=celex%3A32013R0811 (2013)."},{"key":"58014_CR66","doi-asserted-by":"publisher","first-page":"122952","DOI":"10.1016\/j.energy.2021.122952","volume":"242","author":"M L\u00e4mmle","year":"2022","unstructured":"L\u00e4mmle, M. et al. Performance of air and ground source heat pumps retrofitted to radiator heating systems and measures to reduce space heating temperatures in existing buildings. Energy 242, 122952 (2022).","journal-title":"Energy"},{"key":"58014_CR67","doi-asserted-by":"publisher","first-page":"394","DOI":"10.1080\/09613218.2015.1082701","volume":"44","author":"CP Gleeson","year":"2016","unstructured":"Gleeson, C. P. Residential heat pump installations: the role of vocational education and training. Build. Res. Inf. 44, 394\u2013406 (2016).","journal-title":"Build. Res. Inf."},{"key":"58014_CR68","doi-asserted-by":"publisher","first-page":"183","DOI":"10.1016\/j.ijrefrig.2016.02.015","volume":"65","author":"G Bagarella","year":"2016","unstructured":"Bagarella, G., Lazzarin, R. & Noro, M. Sizing strategy of on-off and modulating heat pump systems based on annual energy analysis. Int. J. Refrig. 65, 183\u2013193 (2016).","journal-title":"Int. J. Refrig."},{"key":"58014_CR69","doi-asserted-by":"publisher","first-page":"421","DOI":"10.1016\/j.applthermaleng.2016.02.039","volume":"100","author":"P Hein","year":"2016","unstructured":"Hein, P., Kolditz, O., G\u00f6rke, U.-J., Bucher, A. & Shao, H. A numerical study on the sustainability and efficiency of borehole heat exchanger coupled ground source heat pump systems. Appl. Therm. Eng. 100, 421\u2013433 (2016).","journal-title":"Appl. Therm. Eng."},{"key":"58014_CR70","doi-asserted-by":"publisher","first-page":"121072","DOI":"10.1016\/j.applthermaleng.2023.121072","volume":"233","author":"J Klingebiel","year":"2023","unstructured":"Klingebiel, J., Hassan, M., Venzik, V., Vering, C. & M\u00fcller, D. Efficiency comparison between defrosting methods: a laboratory study on reverse-cycle defrosting, electric heating defrosting, and warm brine defrosting. Appl. Therm. Eng. 233, 121072 (2023).","journal-title":"Appl. Therm. Eng."},{"key":"58014_CR71","doi-asserted-by":"publisher","first-page":"112","DOI":"10.1016\/j.ecolecon.2017.07.031","volume":"144","author":"M Stadelmann","year":"2018","unstructured":"Stadelmann, M. & Schubert, R. How do different designs of energy labels influence purchases of household appliances? A field study in Switzerland. Ecol. Econ. 144, 112\u2013123 (2018).","journal-title":"Ecol. Econ."},{"key":"58014_CR72","doi-asserted-by":"publisher","first-page":"403","DOI":"10.1016\/j.enpol.2013.12.013","volume":"67","author":"L Ntziachristos","year":"2014","unstructured":"Ntziachristos, L. et al. In-use vs. type-approval fuel consumption of current passenger cars in Europe. Energy Policy 67, 403\u2013411 (2014).","journal-title":"Energy Policy"},{"key":"58014_CR73","doi-asserted-by":"publisher","first-page":"112236","DOI":"10.1016\/j.enpol.2021.112236","volume":"152","author":"R Yu","year":"2021","unstructured":"Yu, R., Ren, H., Liu, Y. & Yu, B. Gap between on-road and official fuel efficiency of passenger vehicles in China. Energy Policy 152, 112236 (2021).","journal-title":"Energy Policy"},{"key":"58014_CR74","doi-asserted-by":"publisher","first-page":"1286","DOI":"10.1016\/j.jclepro.2016.09.191","volume":"141","author":"CC Michelsen","year":"2017","unstructured":"Michelsen, C. C. & Madlener, R. Homeowner satisfaction with low-carbon heating technologies. J. Clean. Prod. 141, 1286\u20131292 (2017).","journal-title":"J. Clean. Prod."},{"key":"58014_CR75","doi-asserted-by":"publisher","first-page":"111593","DOI":"10.1016\/j.enpol.2020.111593","volume":"144","author":"J Flower","year":"2020","unstructured":"Flower, J., Hawker, G. & Bell, K. Heterogeneity of UK residential heat demand and its impact on the value case for heat pumps. Energy Policy 144, 111593 (2020).","journal-title":"Energy Policy"},{"key":"58014_CR76","doi-asserted-by":"publisher","first-page":"16799","DOI":"10.3390\/su142416799","volume":"14","author":"E Oikonomou","year":"2022","unstructured":"Oikonomou, E., Zimmermann, N., Davies, M. & Oreszczyn, T. Behavioural change as a domestic heat pump performance driver: Insights on the influence of feedback systems from multiple case studies in the UK. Sustainability 14, 16799 (2022).","journal-title":"Sustainability"},{"key":"58014_CR77","doi-asserted-by":"crossref","unstructured":"Narayanaswamy, B., Balaji, B., Gupta, R. & Agarwal, Y. Data driven investigation of faults in HVAC systems with model, cluster and compare (MCC). In Proceedings of the 1st ACM Conference on Embedded Systems for Energy-Efficient Buildings, BuildSys \u201914, 50\u201359 (Association for Computing Machinery, New York, NY, USA, 2014).","DOI":"10.1145\/2674061.2674067"},{"key":"58014_CR78","doi-asserted-by":"publisher","first-page":"1261","DOI":"10.1177\/0162243920978301","volume":"46","author":"M de Wilde","year":"2021","unstructured":"de Wilde, M. A heat pump needs a bit of care: on maintainability and repairing gender-technology relations. Sci., Technol., Hum. Values 46, 1261\u20131285 (2021).","journal-title":"Sci., Technol., Hum. Values"},{"key":"58014_CR79","doi-asserted-by":"publisher","first-page":"112709","DOI":"10.1016\/j.enpol.2021.112709","volume":"161","author":"R Decuypere","year":"2022","unstructured":"Decuypere, R., Robaeyst, B., Hudders, L., Baccarne, B. & Van de Sompel, D. Transitioning to energy efficient housing: drivers and barriers of intermediaries in heat pump technology. Energy Policy 161, 112709 (2022).","journal-title":"Energy Policy"},{"key":"58014_CR80","doi-asserted-by":"publisher","first-page":"124","DOI":"10.1177\/0957650912471291","volume":"227","author":"N Bergman","year":"2013","unstructured":"Bergman, N. Why is renewable heat in the UK underperforming? a socio-technical perspective. Proc. Inst. Mech. Eng., Part A: J. Power Energy 227, 124\u2013131 (2013).","journal-title":"Proc. Inst. Mech. Eng., Part A: J. Power Energy"},{"key":"58014_CR81","unstructured":"European Heat Pump Association (EHPA). European heat pump market and statistics report 2021. https:\/\/www.ehpa.org\/market-data\/market-report-2021\/ (2023)."},{"key":"58014_CR82","unstructured":"Scheuer, C. W. et al. Adoption of Residential Green Building Practices: Understanding the Role of Familiarity. Ph.D. thesis, University of Michigan (2007)."},{"key":"58014_CR83","unstructured":"Gleeson, C. et al. Analysis Of Heat Pump Data From The Renewable Heat Premium Payment Scheme (Rhpp) To The Department Of Business, Energy And Industrial Strategy: Compliance With Mcs Installation Standards. (2017)."},{"key":"58014_CR84","doi-asserted-by":"publisher","first-page":"1073","DOI":"10.1016\/j.applthermaleng.2016.12.010","volume":"114","author":"M Dongellini","year":"2017","unstructured":"Dongellini, M., Naldi, C. & Morini, G. L. Sizing effects on the energy performance of reversible air-source heat pumps for office buildings. Appl. Therm. Eng. 114, 1073\u20131081 (2017).","journal-title":"Appl. Therm. Eng."},{"key":"58014_CR85","doi-asserted-by":"crossref","unstructured":"Brudermueller, T., Breer, F. & Staake, T. Disaggregation of heat pump load profiles from low-resolution smart meter data. In Proceedings of the 10th ACM International Conference on Systems for Energy-Efficient Buildings, Cities, and Transportation, BuildSys \u201923, 228-231 (Association for Computing Machinery, New York, NY, USA, 2023).","DOI":"10.1145\/3600100.3623731"}],"container-title":["Nature Communications"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.nature.com\/articles\/s41467-025-58014-y.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.nature.com\/articles\/s41467-025-58014-y","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.nature.com\/articles\/s41467-025-58014-y.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,3,25]],"date-time":"2025-03-25T22:54:15Z","timestamp":1742943255000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.nature.com\/articles\/s41467-025-58014-y"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,3,22]]},"references-count":85,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2025,12]]}},"alternative-id":["58014"],"URL":"https:\/\/doi.org\/10.1038\/s41467-025-58014-y","relation":{},"ISSN":["2041-1723"],"issn-type":[{"value":"2041-1723","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,3,22]]},"assertion":[{"value":"31 January 2024","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"4 March 2025","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"22 March 2025","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"T.S. & E.F. declare that they are supervisory board members of companies (Hoval and Bosch, respectively) that, among other products and services, manufacture and sell heating systems. T.B., U.P., & F.W. declare no competing interests. The views and conclusions contained in this document are those of the authors and should not be interpreted as necessarily representing the official policy of the sponsors or partners, either expressed or implied. The funding agencies and partners had no control over the design, conduct, data, analysis, review, reporting, or interpretation of the research conducted.","order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"2834"}}