{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,11,16]],"date-time":"2026-11-16T19:15:28Z","timestamp":1794856528479,"version":"4.9.1"},"reference-count":68,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2025,10,14]],"date-time":"2025-10-14T00:00:00Z","timestamp":1760400000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2025,10,14]],"date-time":"2025-10-14T00:00:00Z","timestamp":1760400000000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"funder":[{"DOI":"10.13039\/501100000038","name":"Gouvernement du Canada | Natural Sciences and Engineering Research Council of Canada","doi-asserted-by":"publisher","award":["CRDPJ 543431"],"award-info":[{"award-number":["CRDPJ 543431"]}],"id":[{"id":"10.13039\/501100000038","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Nat Commun"],"abstract":"<jats:title>Abstract<\/jats:title>\n          <jats:p>Achieving sub-\u00e5ngstr\u00f6m (&lt;1\u2009\u00c5) resolution in electron microscopy typically requires a high-energy (&gt;30\u2009keV) beam and a transmission electron microscope (TEM) fitted with an aberration corrector and a high efficiency, high pixel-count camera. The cost, space- and personnel-requirements of such TEMs is prohibitive for many laboratories. Low-energy (\u226430\u2009keV) scanning electron microscopes (SEMs), in comparison, offer a simpler, more compact, and cost-effective electron microscopy platform. Lower beam energies also have the potential to provide greater information from thin, light-element samples. Here, we demonstrate a sub-\u00e5ngstr\u00f6m resolution of 0.67\u2009\u00c5 using a 20\u2009keV SEM operated in transmission mode, enabled by ptychographic reconstruction. This resolution corresponds to a resolution-to-wavelength ratio of 7.8, surpassing previous results from electron ptychography and conventional imaging approaches. The gain in resolution is achieved through a multi-slice ptychographic algorithm incorporating diffraction distortion correction, coupled with a SEM fitted with a cold field emission source, immersion lens, simple projector lens, and a hybrid direct detector optimized for low-energy electrons. This approach holds immediate promise for high-resolution imaging of 2D materials and, with further development, may enable structural studies of small (&lt;100\u2009kDa) proteins.<\/jats:p>","DOI":"10.1038\/s41467-025-64133-3","type":"journal-article","created":{"date-parts":[[2025,10,14]],"date-time":"2025-10-14T09:03:10Z","timestamp":1760432590000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":9,"title":["Sub-\u00e5ngstr\u00f6m resolution ptychography in a scanning electron microscope at 20\u2009keV"],"prefix":"10.1038","volume":"16","author":[{"ORCID":"https:\/\/orcid.org\/0000-0001-6874-9729","authenticated-orcid":false,"given":"Arthur M.","family":"Blackburn","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-8524-587X","authenticated-orcid":false,"given":"Cristina","family":"Cordoba","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-5347-0629","authenticated-orcid":false,"given":"Matthew R.","family":"Fitzpatrick","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Robert A.","family":"McLeod","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2025,10,14]]},"reference":[{"key":"64133_CR1","doi-asserted-by":"publisher","DOI":"10.1103\/PhysRevLett.117.076101","volume":"117","author":"M Linck","year":"2016","unstructured":"Linck, M. et al. Chromatic aberration correction for atomic resolution TEM imaging from 20 to 80 kV. Phys. Rev. Lett. 117, 076101 (2016).","journal-title":"Phys. Rev. Lett."},{"key":"64133_CR2","doi-asserted-by":"publisher","DOI":"10.1017\/S0033583516000068","volume":"49","author":"KR Vinothkumar","year":"2016","unstructured":"Vinothkumar, K. R. & Henderson, R. Single particle electron cryomicroscopy: trends, issues and future perspective. Q. Rev. Biophys. 49, e13 (2016).","journal-title":"Q. Rev. Biophys."},{"key":"64133_CR3","doi-asserted-by":"publisher","first-page":"42","DOI":"10.1016\/j.ultramic.2016.03.006","volume":"165","author":"M Krajnak","year":"2016","unstructured":"Krajnak, M., McGrouther, D., Maneuski, D., Shea, V. O. & McVitie, S. Pixelated detectors and improved efficiency for magnetic imaging in STEM differential phase contrast. Ultramicroscopy 165, 42\u201350 (2016).","journal-title":"Ultramicroscopy"},{"key":"64133_CR4","doi-asserted-by":"publisher","first-page":"237","DOI":"10.1017\/S1431927615015664","volume":"22","author":"MW Tate","year":"2016","unstructured":"Tate, M. W. et al. High dynamic range pixel array detector for scanning transmission electron microscopy. Microsc. Microanal. 22, 237\u2013249 (2016).","journal-title":"Microsc. Microanal."},{"key":"64133_CR5","unstructured":"Faruqi, A. R. in Advances in Imaging and Electron Physics. (Elsevier, 2007)."},{"key":"64133_CR6","doi-asserted-by":"publisher","first-page":"3180","DOI":"10.1021\/acsaem.8b00391","volume":"1","author":"B Wei","year":"2018","unstructured":"Wei, B. et al. In situ TEM investigation of electron irradiation induced metastable states in lithium-ion battery cathodes: Li2FeSiO4 versus LiFePO4. ACS Appl. Energy Mater. 1, 3180\u20133189 (2018).","journal-title":"ACS Appl. Energy Mater."},{"key":"64133_CR7","doi-asserted-by":"publisher","first-page":"22","DOI":"10.1016\/j.ultramic.2017.03.020","volume":"180","author":"SJ Pennycook","year":"2017","unstructured":"Pennycook, S. J. The impact of STEM aberration correction on materials science. Ultramicroscopy 180, 22\u201333 (2017).","journal-title":"Ultramicroscopy"},{"key":"64133_CR8","doi-asserted-by":"publisher","first-page":"324","DOI":"10.1016\/j.bbagen.2017.07.020","volume":"1862","author":"K Murata","year":"2018","unstructured":"Murata, K. & Wolf, M. Cryo-electron microscopy for structural analysis of dynamic biological macromolecules. Biochim. Biophys. Acta Gen. Subj. 1862, 324\u2013334 (2018).","journal-title":"Biochim. Biophys. Acta Gen. Subj."},{"key":"64133_CR9","doi-asserted-by":"publisher","first-page":"12","DOI":"10.1017\/S1551929500050951","volume":"15","author":"V Van Ngo","year":"2007","unstructured":"Van Ngo, V., Hernandez, M., Roth, B. & Joy, D. C. STEM Imaging of Lattice Fringes and beyond in a UHR In-Lens Field-Emission SEM. Microsc. Today 15, 12\u201317 (2007).","journal-title":"Microsc. Today"},{"key":"64133_CR10","doi-asserted-by":"publisher","first-page":"28","DOI":"10.1016\/j.ultramic.2013.09.001","volume":"145","author":"M Konno","year":"2014","unstructured":"Konno, M., Ogashiwa, T., Sunaoshi, T., Orai, Y. & Sato, M. Lattice imaging at an accelerating voltage of 30 kV using an in-lens type cold field-emission scanning electron microscope. Ultramicroscopy 145, 28\u201335 (2014).","journal-title":"Ultramicroscopy"},{"key":"64133_CR11","doi-asserted-by":"publisher","first-page":"337","DOI":"10.1093\/jmicro\/dfu027","volume":"63","author":"K Kimoto","year":"2014","unstructured":"Kimoto, K. Practical aspects of monochromators developed for transmission electron microscopy. Microscopy 63, 337\u2013344 (2014).","journal-title":"Microscopy"},{"key":"64133_CR12","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1016\/j.ultramic.2018.03.009","volume":"189","author":"H Dohi","year":"2018","unstructured":"Dohi, H. & Kruit, P. Design for an aberration corrected scanning electron microscope using miniature electron mirrors. Ultramicroscopy 189, 1\u201323 (2018).","journal-title":"Ultramicroscopy"},{"key":"64133_CR13","doi-asserted-by":"publisher","DOI":"10.1116\/1.4931933","volume":"33","author":"T Ogawa","year":"2015","unstructured":"Ogawa, T., Cho, B. & Ahn, S. J. Low-energy scanning electron microscope using a monochromator with double-offset cylindrical lenses. J. Vac. Sci. Technol. B 33, 06FJ01 (2015).","journal-title":"J. Vac. Sci. Technol. B"},{"key":"64133_CR14","unstructured":"Rodenburg, J. & Maiden, A. in Springer Handbook of Microscopy. (Springer International Publishing, 2019)."},{"key":"64133_CR15","doi-asserted-by":"publisher","first-page":"131","DOI":"10.1093\/jmicro\/dfaa055","volume":"70","author":"AM Blackburn","year":"2020","unstructured":"Blackburn, A. M. & McLeod, R. A. Practical implementation of high-resolution electron ptychography and comparison with off-axis electron holography. Microscopy 70, 131\u2013147 (2020).","journal-title":"Microscopy"},{"key":"64133_CR16","doi-asserted-by":"publisher","DOI":"10.1038\/s41467-020-16391-6","volume":"11","author":"L Zhou","year":"2020","unstructured":"Zhou, L. et al. Low-dose phase retrieval of biological specimens using cryo-electron ptychography. Nat. Commun. 11, 2773 (2020).","journal-title":"Nat. Commun."},{"key":"64133_CR17","doi-asserted-by":"publisher","DOI":"10.1016\/j.ultramic.2021.113257","volume":"231","author":"F Allars","year":"2021","unstructured":"Allars, F. et al. Efficient large field of view electron phase imaging using near-field electron ptychography with a diffuser. Ultramicroscopy 231, 113257 (2021).","journal-title":"Ultramicroscopy"},{"key":"64133_CR18","doi-asserted-by":"publisher","DOI":"10.1038\/s41598-017-07488-y","volume":"7","author":"PM Pelz","year":"2017","unstructured":"Pelz, P. M., Qiu, W. X., B\u00fccker, R., Kassier, G. & Miller, R. J. D. Low-dose cryo electron ptychography via non-convex Bayesian optimization. Sci. Rep. 7, 9883 (2017).","journal-title":"Sci. Rep."},{"key":"64133_CR19","doi-asserted-by":"publisher","first-page":"826","DOI":"10.1126\/science.abg2533","volume":"372","author":"Z Chen","year":"2021","unstructured":"Chen, Z. et al. Electron ptychography achieves atomic-resolution limits set by lattice vibrations. Science 372, 826 (2021).","journal-title":"Science"},{"key":"64133_CR20","doi-asserted-by":"publisher","DOI":"10.1038\/s41467-020-16688-6","volume":"11","author":"Z Chen","year":"2020","unstructured":"Chen, Z. et al. Mixed-state electron ptychography enables sub-angstrom resolution imaging with picometer precision at low dose. Nat. Commun. 11, 2994 (2020).","journal-title":"Nat. Commun."},{"key":"64133_CR21","doi-asserted-by":"publisher","first-page":"343","DOI":"10.1038\/s41586-018-0298-5","volume":"559","author":"Y Jiang","year":"2018","unstructured":"Jiang, Y. et al. Electron ptychography of 2D materials to deep sub-\u00e5ngstr\u00f6m resolution. Nature 559, 343\u2013349 (2018).","journal-title":"Nature"},{"key":"64133_CR22","doi-asserted-by":"publisher","DOI":"10.1038\/s41467-023-35877-7","volume":"14","author":"H Sha","year":"2023","unstructured":"Sha, H. et al. Sub-nanometer-scale mapping of crystal orientation and depth-dependent structure of dislocation cores in SrTiO3. Nat. Commun. 14, 162 (2023).","journal-title":"Nat. Commun."},{"key":"64133_CR23","doi-asserted-by":"publisher","DOI":"10.1126\/sciadv.abn2275","volume":"8","author":"H Sha","year":"2022","unstructured":"Sha, H., Cui, J. & Yu, R. Deep sub-angstrom resolution imaging by electron ptychography with misorientation correction. Sci. Adv. 8, eabn2275 (2022).","journal-title":"Sci. Adv."},{"key":"64133_CR24","doi-asserted-by":"publisher","first-page":"633","DOI":"10.1126\/science.adg3183","volume":"380","author":"H Zhang","year":"2023","unstructured":"Zhang, H. et al. Three-dimensional inhomogeneity of zeolite structure and composition revealed by electron ptychography. Science 380, 633\u2013638 (2023).","journal-title":"Science"},{"key":"64133_CR25","doi-asserted-by":"crossref","unstructured":"Humphry, M. J., Kraus, B., Hurst, A. C., Maiden, A. M. & Rodenburg, J. M. Ptychographic electron microscopy using high-angle dark-field scattering for sub-nanometre resolution imaging. Nat. Commun. 3, 730 (2012).","DOI":"10.1038\/ncomms1733"},{"key":"64133_CR26","doi-asserted-by":"publisher","first-page":"1256","DOI":"10.1016\/j.ultramic.2009.05.012","volume":"109","author":"AM Maiden","year":"2009","unstructured":"Maiden, A. M. & Rodenburg, J. M. An improved ptychographical phase retrieval algorithm for diffractive imaging. Ultramicroscopy 109, 1256\u20131262 (2009).","journal-title":"Ultramicroscopy"},{"key":"64133_CR27","unstructured":"Batey, D. Ptychographic Imaging of Mixed States. (PhD thesis, University of Sheffield, 2014)."},{"key":"64133_CR28","doi-asserted-by":"crossref","unstructured":"Allen, C. S., Danaie, M., Warner, J. H., Batey, D. J. & Kirkland, A. I. Super-resolution electron ptychography of low dimensional materials at 30 keV: Beyond the detector limit. Appl. Phys. Lett. 123, 023101 (2023).","DOI":"10.1063\/5.0143684"},{"key":"64133_CR29","doi-asserted-by":"publisher","first-page":"125","DOI":"10.1016\/j.ultramic.2019.02.007","volume":"203","author":"MJ Peet","year":"2019","unstructured":"Peet, M. J., Henderson, R. & Russo, C. J. The energy dependence of contrast and damage in electron cryomicroscopy of biological molecules. Ultramicroscopy 203, 125\u2013131 (2019).","journal-title":"Ultramicroscopy"},{"key":"64133_CR30","doi-asserted-by":"publisher","first-page":"2458","DOI":"10.1021\/acs.jcim.9b01178","volume":"60","author":"MA Cianfrocco","year":"2020","unstructured":"Cianfrocco, M. A. & Kellogg, E. H. What could go wrong? a practical guide to single-particle cryo-eM: From biochemistry to atomic models. J. Chem. Inf. Model. 60, 2458\u20132469 (2020).","journal-title":"J. Chem. Inf. Model."},{"key":"64133_CR31","doi-asserted-by":"publisher","DOI":"10.1007\/s12575-009-9008-x","volume":"11","author":"HP Erickson","year":"2009","unstructured":"Erickson, H. P. Size and shape of protein molecules at the nanometer level determined by sedimentation, gel filtration, and electron microscopy. Biol. Proced. Online 11, 32 (2009).","journal-title":"Biol. Proced. Online"},{"key":"64133_CR32","doi-asserted-by":"publisher","DOI":"10.1038\/s41467-023-38268-0","volume":"14","author":"X Pei","year":"2023","unstructured":"Pei, X. et al. Cryogenic electron ptychographic single particle analysis with wide bandwidth information transfer. Nat. Commun. 14, 3027 (2023).","journal-title":"Nat. Commun."},{"key":"64133_CR33","doi-asserted-by":"publisher","first-page":"332","DOI":"10.1016\/j.crstbi.2022.09.005","volume":"4","author":"K Wentinck","year":"2022","unstructured":"Wentinck, K., Gogou, C. & Meijer, D. H. Putting on molecular weight: Enabling cryo-EM structure determination of sub-100-kDa proteins. Curr. Res. Struct. Biol. 4, 332\u2013337 (2022).","journal-title":"Curr. Res. Struct. Biol."},{"key":"64133_CR34","doi-asserted-by":"publisher","first-page":"610","DOI":"10.1111\/mmi.14820","volume":"117","author":"DC Shepherd","year":"2022","unstructured":"Shepherd, D. C., Dalvi, S. & Ghosal, D. From cells to atoms: Cryo-EM as an essential tool to investigate pathogen biology, host\u2013pathogen interaction, and drug discovery. Mol. Microbiol. 117, 610\u2013617 (2022).","journal-title":"Mol. Microbiol."},{"key":"64133_CR35","doi-asserted-by":"publisher","first-page":"259","DOI":"10.1038\/s41586-021-04323-3","volume":"603","author":"F Wu","year":"2022","unstructured":"Wu, F. et al. Vertical MoS2 transistors with sub-1-nm gate lengths. Nature 603, 259\u2013264 (2022).","journal-title":"Nature"},{"key":"64133_CR36","doi-asserted-by":"publisher","first-page":"2865","DOI":"10.1021\/acs.nanolett.0c00670","volume":"20","author":"S Kretschmer","year":"2020","unstructured":"Kretschmer, S., Lehnert, T., Kaiser, U. & Krasheninnikov, A. V. Formation of defects in two-dimensional MoS2 in the transmission electron microscope at electron energies below the knock-on threshold: the role of electronic excitations. Nano Lett. 20, 2865\u20132870 (2020).","journal-title":"Nano Lett."},{"key":"64133_CR37","doi-asserted-by":"publisher","DOI":"10.1038\/s41467-022-29001-4","volume":"13","author":"MC Lemme","year":"2022","unstructured":"Lemme, M. C., Akinwande, D., Huyghebaert, C. & Stampfer, C. 2D materials for future heterogeneous electronics. Nat. Commun. 13, 1392 (2022).","journal-title":"Nat. Commun."},{"key":"64133_CR38","doi-asserted-by":"publisher","DOI":"10.1103\/PhysRevE.100.023308","volume":"100","author":"X Li","year":"2019","unstructured":"Li, X. et al. Structure retrieval from four-dimensional scanning transmission electron microscopy: Statistical analysis of potential pitfalls in high-dimensional data. Phys. Rev. E 100, 023308 (2019).","journal-title":"Phys. Rev. E"},{"key":"64133_CR39","doi-asserted-by":"publisher","first-page":"71","DOI":"10.1016\/j.ultramic.2018.01.006","volume":"187","author":"S Cao","year":"2018","unstructured":"Cao, S., Maiden, A. M. & Rodenburg, J. M. Image feature delocalization in defocused probe electron ptychography. Ultramicroscopy 187, 71\u201383 (2018).","journal-title":"Ultramicroscopy"},{"key":"64133_CR40","unstructured":"Hawkes, P. W. in Handbook of Charged Particle Optics. (CRC Press, 1997)."},{"key":"64133_CR41","doi-asserted-by":"publisher","first-page":"735","DOI":"10.1107\/S2052252522007904","volume":"9","author":"P Brazda","year":"2022","unstructured":"Brazda, P., Klementova, M., Krysiak, Y. & Palatinus, L. Accurate lattice parameters from 3D electron diffraction data. I. Optical distortions. IUCrJ 9, 735\u2013755 (2022).","journal-title":"IUCrJ"},{"key":"64133_CR42","doi-asserted-by":"publisher","first-page":"S7","DOI":"10.1093\/jmicro\/dfq027","volume":"59","author":"T Sasaki","year":"2010","unstructured":"Sasaki, T. et al. Performance of low-voltage STEM\/TEM with delta corrector and cold field emission gun. J. Electron Microsc. 59, S7\u2013S13 (2010).","journal-title":"J. Electron Microsc."},{"key":"64133_CR43","doi-asserted-by":"publisher","first-page":"222","DOI":"10.1016\/j.pnsc.2013.04.003","volume":"23","author":"JM Thomas","year":"2013","unstructured":"Thomas, J. M., Midgley, P. A., Ducati, C. & Leary, R. K. Nanoscale electron tomography and atomic scale high-resolution electron microscopy of nanoparticles and nanoclusters: A short surveyNanoscale electron tomography and atomic scale high-resolution electron microscopy of nanoparticles and nanoclusters: A short survey. Prog. Nat. Sci. Mater. Int. 23, 222\u2013234 (2013).","journal-title":"Prog. Nat. Sci. Mater. Int."},{"key":"64133_CR44","doi-asserted-by":"crossref","unstructured":"Swanson, H. E. & Tatge, E. Standard X-ray Diffraction Powder Patterns. (1953).","DOI":"10.1063\/1.3061729"},{"key":"64133_CR45","doi-asserted-by":"publisher","first-page":"21333","DOI":"10.1364\/OE.19.021333","volume":"19","author":"J Vila-Comamala","year":"2011","unstructured":"Vila-Comamala, J. et al. Characterization of high-resolution diffractive X-ray optics by ptychographic coherent diffractive imaging. Opt. Express 19, 21333\u201321344 (2011).","journal-title":"Opt. Express"},{"key":"64133_CR46","doi-asserted-by":"publisher","first-page":"250","DOI":"10.1016\/j.jsb.2005.05.009","volume":"151","author":"M van Heel","year":"2005","unstructured":"van Heel, M. & Schatz, M. Fourier shell correlation threshold criteria. J. Struct. Biol. 151, 250\u2013262 (2005).","journal-title":"J. Struct. Biol."},{"key":"64133_CR47","doi-asserted-by":"crossref","unstructured":"Jiang, Y. et al. Achieving high spatial resolution in a large field-of-view using lensless x-ray imaging. Appl. Phys. Lett. 119, 124101 (2021).","DOI":"10.1063\/5.0067197"},{"key":"64133_CR48","doi-asserted-by":"publisher","first-page":"991","DOI":"10.1016\/j.ultramic.2009.11.003","volume":"110","author":"RF Egerton","year":"2010","unstructured":"Egerton, R. F., McLeod, R., Wang, F. & Malac, M. Basic questions related to electron-induced sputtering in the TEM. Ultramicroscopy 110, 991\u2013997 (2010).","journal-title":"Ultramicroscopy"},{"key":"64133_CR49","doi-asserted-by":"crossref","unstructured":"Penczek, P. A. in Methods in Enzymology 482 (ed Grant J. Jensen) 73\u2013100 (Academic Press, 2010).","DOI":"10.1016\/S0076-6879(10)82003-8"},{"key":"64133_CR50","doi-asserted-by":"publisher","first-page":"995","DOI":"10.1107\/S2052252520011574","volume":"7","author":"P Penczek","year":"2020","unstructured":"Penczek, P. Reliable cryo-EM resolution estimation with modified Fourier shell correlation. IUCrJ 7, 995\u20131008 (2020).","journal-title":"IUCrJ"},{"key":"64133_CR51","doi-asserted-by":"publisher","first-page":"29089","DOI":"10.1364\/OE.24.029089","volume":"24","author":"EHR Tsai","year":"2016","unstructured":"Tsai, E. H. R., Usov, I., Diaz, A., Menzel, A. & Guizar-Sicairos, M. X-ray ptychography with extended depth of field. Opt. Express 24, 29089\u201329108 (2016).","journal-title":"Opt. Express"},{"key":"64133_CR52","doi-asserted-by":"publisher","DOI":"10.1038\/s41467-021-21363-5","volume":"12","author":"K Reidy","year":"2021","unstructured":"Reidy, K. et al. Direct imaging and electronic structure modulation of moir\u00e9 superlattices at the 2D\/3D interface. Nat. Commun. 12, 1290 (2021).","journal-title":"Nat. Commun."},{"key":"64133_CR53","doi-asserted-by":"publisher","first-page":"68","DOI":"10.1038\/nature11806","volume":"494","author":"P Thibault","year":"2013","unstructured":"Thibault, P. & Menzel, A. Reconstructing state mixtures from diffraction measurements. Nature 494, 68 (2013).","journal-title":"Nature"},{"key":"64133_CR54","doi-asserted-by":"publisher","first-page":"5574","DOI":"10.1364\/OL.40.005574","volume":"40","author":"M Odstrcil","year":"2015","unstructured":"Odstrcil, M. et al. Ptychographic imaging with a compact gas\u2013discharge plasma extreme ultraviolet light source. Opt. Lett. 40, 5574\u20135577 (2015).","journal-title":"Opt. Lett."},{"key":"64133_CR55","doi-asserted-by":"publisher","first-page":"L55","DOI":"10.1116\/1.3488988","volume":"28","author":"K Kasuya","year":"2010","unstructured":"Kasuya, K., Katagiri, S., Ohshima, T. & Kokubo, S. Stabilization of a tungsten [310] cold field emitter. J. Vac. Sci. Technol. B 28, L55\u2013L60 (2010).","journal-title":"J. Vac. Sci. Technol. B"},{"key":"64133_CR56","unstructured":"Wyckoff, R. W. G. Crystal Structures. (Interscience Publishers, 1963)."},{"key":"64133_CR57","doi-asserted-by":"publisher","first-page":"248","DOI":"10.1093\/jmicro\/dfaa018","volume":"69","author":"AM Blackburn","year":"2020","unstructured":"Blackburn, A. M. & Sasaki, T. Particle diameter, signal-to-noise ratio and beam requirements for extended Rayleigh resolution measurements in the scanning electron microscope. Microscopy 69, 248\u2013257 (2020).","journal-title":"Microscopy"},{"key":"64133_CR58","unstructured":"Sato, M. in Handbook of Charged Particle Optics. (CRC Press, 1997)."},{"key":"64133_CR59","doi-asserted-by":"publisher","first-page":"63","DOI":"10.1038\/nmeth.2727","volume":"11","author":"A Kucukelbir","year":"2014","unstructured":"Kucukelbir, A., Sigworth, F. J. & Tagare, H. D. Quantifying the local resolution of cryo-EM density maps. Nat. Methods 11, 63\u201365 (2014).","journal-title":"Nat. Methods"},{"key":"64133_CR60","doi-asserted-by":"publisher","first-page":"245","DOI":"10.1093\/jmicro\/53.3.245","volume":"53","author":"T Ishitani","year":"2004","unstructured":"Ishitani, T. & Sato, M. Contrast-to-gradient method for the evaluation of image resolution taking account of random noise in scanning electron microscopy. J. Electron Microsc. 53, 245\u2013255 (2004).","journal-title":"J. Electron Microsc."},{"key":"64133_CR61","doi-asserted-by":"publisher","first-page":"78","DOI":"10.1093\/jmicro\/dfac045","volume":"72","author":"R Ishikawa","year":"2023","unstructured":"Ishikawa, R., Morishita, S., Tanigaki, T., Shibata, N. & Ikuhara, Y. Spatial and phase resolution in electron microscopy. Microscopy 72, 78\u201396 (2023).","journal-title":"Microscopy"},{"key":"64133_CR62","doi-asserted-by":"publisher","first-page":"963","DOI":"10.1107\/S1600577517009109","volume":"24","author":"G Tinti","year":"2017","unstructured":"Tinti, G. et al. The EIGER detector for low-energy electron microscopy and photoemission electron microscopy. J. Synchrotron Radiat. 24, 963\u2013974 (2017).","journal-title":"J. Synchrotron Radiat."},{"key":"64133_CR63","doi-asserted-by":"publisher","first-page":"3108","DOI":"10.1364\/OE.26.003108","volume":"26","author":"M Odstr\u010dil","year":"2018","unstructured":"Odstr\u010dil, M., Menzel, A. & Guizar-Sicairos, M. Iterative least-squares solver for generalized maximum-likelihood ptychography. Opt. Express 26, 3108\u20133123 (2018).","journal-title":"Opt. Express"},{"key":"64133_CR64","doi-asserted-by":"publisher","first-page":"574","DOI":"10.1107\/S1600576720001776","volume":"53","author":"K Wakonig","year":"2020","unstructured":"Wakonig, K. et al. PtychoShelves, a versatile high-level framework for high-performance analysis of ptychographic data. J. Appl. Crystallogr. 53, 574\u2013586 (2020).","journal-title":"J. Appl. Crystallogr."},{"key":"64133_CR65","doi-asserted-by":"publisher","first-page":"604","DOI":"10.1364\/JOSAA.28.000604","volume":"28","author":"AM Maiden","year":"2011","unstructured":"Maiden, A. M., Humphry, M. J., Zhang, F. & Rodenburg, J. M. Superresolution imaging via ptychography. J. Opt. Soc. Am. A28, 604\u2013612 (2011).","journal-title":"J. Opt. Soc. Am. A"},{"key":"64133_CR66","doi-asserted-by":"publisher","first-page":"65","DOI":"10.1002\/mrm.1910340111","volume":"34","author":"P Jezzard","year":"1995","unstructured":"Jezzard, P. & Balaban, R. S. Correction for geometric distortion in echo planar images from B0 field variations. Magn. Reson. Med. 34, 65\u201373 (1995).","journal-title":"Magn. Reson. Med."},{"key":"64133_CR67","doi-asserted-by":"publisher","unstructured":"Blackburn, A. M., Cordoba, C., Fitzpatrick, M. R. & McLeod, R. A. Electron diffraction data and ptychographic reconstructions using a 20 keV electron beam on supported gold nanoparticles. https:\/\/doi.org\/10.20383\/103.01357 (2025).","DOI":"10.20383\/103.01357"},{"key":"64133_CR68","doi-asserted-by":"publisher","DOI":"10.5281\/zenodo.16957173","author":"AM Blackburn","year":"2025","unstructured":"Blackburn, A. M. Codes for realization of sub-\u00e5ngstr\u00f6m resolution ptychography in a scanning electron microscope at 20 keV. Zenodo, https:\/\/doi.org\/10.5281\/zenodo.16957173 (2025).","journal-title":"Zenodo"}],"container-title":["Nature Communications"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.nature.com\/articles\/s41467-025-64133-3.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.nature.com\/articles\/s41467-025-64133-3","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.nature.com\/articles\/s41467-025-64133-3.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,14]],"date-time":"2025-10-14T09:03:16Z","timestamp":1760432596000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.nature.com\/articles\/s41467-025-64133-3"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,10,14]]},"references-count":68,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2025,12]]}},"alternative-id":["64133"],"URL":"https:\/\/doi.org\/10.1038\/s41467-025-64133-3","relation":{},"ISSN":["2041-1723"],"issn-type":[{"value":"2041-1723","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,10,14]]},"assertion":[{"value":"10 August 2023","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"3 September 2025","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"14 October 2025","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"Hitachi High-Tech provided the instrument used in this study, supports a research chair for AMB, and employs RAM. The remaining authors declare no competing interests.","order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"8977"}}