{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,23]],"date-time":"2026-10-23T11:43:45Z","timestamp":1792755825457,"version":"4.5.0"},"reference-count":11,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2026,4,2]],"date-time":"2026-04-02T00:00:00Z","timestamp":1775088000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2026,4,2]],"date-time":"2026-04-02T00:00:00Z","timestamp":1775088000000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"funder":[{"DOI":"10.13039\/501100001505","name":"Manatu Hauora | Health Research Council of New Zealand","doi-asserted-by":"publisher","id":[{"id":"10.13039\/501100001505","id-type":"DOI","asserted-by":"publisher"}]},{"DOI":"10.13039\/501100004629","name":"Ministry for Business Innovation and Employment","doi-asserted-by":"publisher","id":[{"id":"10.13039\/501100004629","id-type":"DOI","asserted-by":"publisher"}]},{"DOI":"10.13039\/501100001515","name":"Cure Kids","doi-asserted-by":"publisher","id":[{"id":"10.13039\/501100001515","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Nat Commun"],"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:p>Emerging neurotechnologies such as brain-computer interfaces and implantable sensors offer considerable promise in the treatment of a broad range of neurological conditions. The key challenges are reducing the implant size, powering it, and confirming long-term accuracy and safety. Here we report the development of a novel type of implantable medical device that measures intracranial pressure long term and which weighs only 0.28\u2009g. Currently the management of hydrocephalus patients relies heavily on non-specific symptoms e.g. headache and there is a lack of actionable data to drive decisions that are not solely hospital based such as imaging. The implant is designed to sit within the cerebral cortex. In a group of 10 adults and 10 children with hydrocephalus we demonstrated that the device was safe and capable of remotely monitoring intracranial pressure in patients at home for up to 18 months (ClinicalTrial.gov NCT06402786). In several children shunt failures occurred and these were associated with raised ICP. Instead of relying on non-specific symptoms such as headache, physicians were able to obtain real-time intracranial pressure readings that can lead to changes in the management of these complex patients.<\/jats:p>","DOI":"10.1038\/s41467-026-70864-8","type":"journal-article","created":{"date-parts":[[2026,4,2]],"date-time":"2026-04-02T09:02:13Z","timestamp":1775120533000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":3,"title":["Long-term brain pressure monitoring via a discrete microimplant; a first-in-human safety and initial efficacy trial in adults and children with hydrocephalus"],"prefix":"10.1038","volume":"17","author":[{"ORCID":"https:\/\/orcid.org\/0000-0003-0608-1430","authenticated-orcid":false,"given":"Simon C.","family":"Malpas","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-0468-4924","authenticated-orcid":false,"given":"Bryon E.","family":"Wright","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Sarah-Jane","family":"Guild","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Peter","family":"Heppner","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Robert J.","family":"Gallichan","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Dixon P.","family":"Leung","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Sang Ho","family":"Kim","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-2556-4972","authenticated-orcid":false,"given":"Quinn","family":"Boesley","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-1884-4378","authenticated-orcid":false,"given":"Sheryl","family":"Tan","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Masahiro","family":"Kondo","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Davina J.","family":"McAllister","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-5995-5432","authenticated-orcid":false,"given":"John A.","family":"Windsor","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Doug","family":"Campbell","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-2469-9023","authenticated-orcid":false,"given":"P.","family":"Alan Barber","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Daniel","family":"McCormick","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2026,4,2]]},"reference":[{"key":"70864_CR1","doi-asserted-by":"publisher","first-page":"75","DOI":"10.1038\/s41582-020-00426-z","volume":"17","author":"JK Krauss","year":"2021","unstructured":"Krauss, J. K. et al. Technology of deep brain stimulation: current status and future directions. Nat. Rev. Neurol. 17, 75\u201387 (2021).","journal-title":"Nat. Rev. Neurol."},{"key":"70864_CR2","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1007\/s10143-021-01673-4","volume":"45","author":"AM Cabral","year":"2022","unstructured":"Cabral, A. M. et al. Prevalence of distinct types of hardware failures related to deep brain stimulation. Neurosurgical Rev. 45, 1\u201312 (2022).","journal-title":"Neurosurgical Rev."},{"key":"70864_CR3","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1016\/j.jneumeth.2005.08.015","volume":"148","author":"VS Polikov","year":"2005","unstructured":"Polikov, V. S. et al. Response of brain tissue to chronically implanted neural electrodes. J. Neurosci. Methods 148, 1\u201318 (2005).","journal-title":"J. Neurosci. Methods"},{"key":"70864_CR4","doi-asserted-by":"publisher","first-page":"499","DOI":"10.1007\/s00381-020-04878-y","volume":"37","author":"L Tong","year":"2021","unstructured":"Tong, L. et al. Possible shunt malfunction\u2019 pathway for paediatric hydrocephalus\u2014a study of clinical outcomes and cost implications. Childs Nerv. Syst. 37, 499\u2013509 (2021).","journal-title":"Childs Nerv. Syst."},{"key":"70864_CR5","doi-asserted-by":"publisher","first-page":"255","DOI":"10.3171\/2024.9.PEDS24378","volume":"35","author":"SH Kim","year":"2024","unstructured":"Kim, S. H. et al. False alarms and the burden of shunt failure in pediatric patients with hydrocephalus: a longitudinal study. J. Neurosurg. Pediatr. 35, 255\u2013265 (2024).","journal-title":"J. Neurosurg. Pediatr."},{"key":"70864_CR6","first-page":"1","volume":"39","author":"International Commission on Radiological Protection (ICRP)","year":"2009","unstructured":"International Commission on Radiological Protection (ICRP) ICRP publication 110: adult reference computational phantoms. Ann. ICRP 39, 1\u2013166 (2009).","journal-title":"Ann. ICRP"},{"key":"70864_CR7","unstructured":"MAUDE Adverse Event Report: St Jude Medical, Inc- Cardiomems HF sensor delivery system: https:\/\/www.accessdata.fda.gov\/scripts\/cdrh\/cfdocs\/cfmaude\/detail.cfm?mdrfoi__id=10732134&pc=MOM"},{"key":"70864_CR8","doi-asserted-by":"publisher","DOI":"10.3389\/fped.2025.1632216","volume":"13","author":"K Yangi","year":"2025","unstructured":"Yangi, K. et al. Telemetric intracranial pressure monitoring in patients with hydrocephalus: a systematic literature review. Front Pediatr. 13, 1632216 (2025).","journal-title":"Front Pediatr."},{"key":"70864_CR9","doi-asserted-by":"publisher","first-page":"524","DOI":"10.1007\/BF00335075","volume":"10","author":"J Kast","year":"1994","unstructured":"Kast, J., Duong, D., Nowzari, F., Chadduck, W. M. & Schiff, S. J. Time-related patterns of ventricular shunt failure. Childs Nerv. Syst. 10, 524\u2013528 (1994).","journal-title":"Childs Nerv. Syst."},{"key":"70864_CR10","doi-asserted-by":"publisher","first-page":"e0124126","DOI":"10.1371\/journal.pone.0124126","volume":"10","author":"MI Iacono","year":"2015","unstructured":"Iacono, M. I. et al. MIDA: a multimodal imaging-based detailed anatomical model of the human head and neck. PLoS ONE 10, e0124126 (2015).","journal-title":"PLoS ONE"},{"key":"70864_CR11","doi-asserted-by":"publisher","DOI":"10.3389\/fnins.2021.796203","volume":"15","author":"AH Dabbour","year":"2021","unstructured":"Dabbour, A. H. et al. The safety of micro-implants for the brain. Front Neurosci. 15, 796203 (2021).","journal-title":"Front Neurosci."}],"container-title":["Nature Communications"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.nature.com\/articles\/s41467-026-70864-8.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.nature.com\/articles\/s41467-026-70864-8","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.nature.com\/articles\/s41467-026-70864-8.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,4,2]],"date-time":"2026-04-02T09:02:15Z","timestamp":1775120535000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.nature.com\/articles\/s41467-026-70864-8"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,4,2]]},"references-count":11,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2026,12]]}},"alternative-id":["70864"],"URL":"https:\/\/doi.org\/10.1038\/s41467-026-70864-8","relation":{},"ISSN":["2041-1723"],"issn-type":[{"value":"2041-1723","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,4,2]]},"assertion":[{"value":"20 July 2025","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"6 March 2026","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"2 April 2026","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"Authors Malpas, Wright, Guild, Gallichan, Leung, Kondo\u00a0and\u00a0McCormick are employees and shareholders in the company Kitea Health Ltd. The authors declared no other competing interests.","order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"3158"}}