{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,26]],"date-time":"2026-09-26T12:16:02Z","timestamp":1790424962273,"version":"4.1.0"},"reference-count":80,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2026,4,20]],"date-time":"2026-04-20T00:00:00Z","timestamp":1776643200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0"},{"start":{"date-parts":[[2026,6,22]],"date-time":"2026-06-22T00:00:00Z","timestamp":1782086400000},"content-version":"vor","delay-in-days":63,"URL":"https:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0"}],"funder":[{"name":"USC Zumberge Preliminary Studies Research Award"},{"DOI":"10.13039\/100000001","name":"National Science Foundation","doi-asserted-by":"publisher","award":["1828736"],"award-info":[{"award-number":["1828736"]}],"id":[{"id":"10.13039\/100000001","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Nat Commun"],"DOI":"10.1038\/s41467-026-71817-x","type":"journal-article","created":{"date-parts":[[2026,4,20]],"date-time":"2026-04-20T18:54:06Z","timestamp":1776711246000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":1,"title":["Improved dynamic MRI of the wrist and heart at 0.55\u00a0T enabled by rapid 3D printed flexible coils"],"prefix":"10.1038","volume":"17","author":[{"given":"F\u00e9lix","family":"Mu\u00f1oz","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ye","family":"Tian","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ted","family":"L\u00ea","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jaehwan","family":"Jang","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Helmut","family":"Stark","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-0998-3643","authenticated-orcid":false,"given":"Mohammad Shafiqul","family":"Islam","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-6038-1448","authenticated-orcid":false,"given":"Min-gu","family":"Kim","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-5735-3550","authenticated-orcid":false,"given":"Krishna S.","family":"Nayak","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-2290-0854","authenticated-orcid":false,"given":"Yasser","family":"Khan","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2026,4,20]]},"reference":[{"key":"71817_CR1","doi-asserted-by":"publisher","first-page":"e223008","DOI":"10.1148\/radiol.223008","volume":"307","author":"PS Rajiah","year":"2023","unstructured":"Rajiah, P. S., Fran\u00e7ois, C. J. & Leiner, T. Cardiac MRI: state of the art. Radiology 307, e223008 (2023).","journal-title":"Radiology"},{"key":"71817_CR2","doi-asserted-by":"publisher","first-page":"299","DOI":"10.1038\/nn.4500","volume":"20","author":"TE Nichols","year":"2017","unstructured":"Nichols, T. E. et al. Best practices in data analysis and sharing in neuroimaging using MRI. Nat. Neurosci. 20, 299\u2013303 (2017).","journal-title":"Nat. Neurosci."},{"key":"71817_CR3","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1007\/s10334-023-01123-w","volume":"37","author":"Y Tian","year":"2024","unstructured":"Tian, Y. & Nayak, K. S. New clinical opportunities of low-field MRI: heart, lung, body, and musculoskeletal. Magn. Reson. Mater. Phys. 37, 1\u201314 (2024).","journal-title":"Magn. Reson. Mater. Phys."},{"key":"71817_CR4","doi-asserted-by":"publisher","first-page":"217","DOI":"10.1053\/j.ctep.2007.08.008","volume":"6","author":"CJ Zubrod","year":"2007","unstructured":"Zubrod, C. J. & Barrett, M. F. Magnetic resonance imaging of tendon and ligament injuries. Clin. Tech. Equine Pract. 6, 217\u2013229 (2007).","journal-title":"Clin. Tech. Equine Pract."},{"key":"71817_CR5","doi-asserted-by":"publisher","first-page":"718","DOI":"10.2214\/AJR.20.22902","volume":"216","author":"J Fritz","year":"2021","unstructured":"Fritz, J., Guggenberger, R. & Del Grande, F. Rapid musculoskeletal MRI in 2021: clinical application of advanced accelerated techniques. AJR Am. J. Roentgenol. 216, 718\u2013733 (2021).","journal-title":"AJR Am. J. Roentgenol."},{"key":"71817_CR6","doi-asserted-by":"publisher","first-page":"529329","DOI":"10.3389\/fphys.2020.00626","volume":"11","author":"U Sinha","year":"2020","unstructured":"Sinha, U. et al. Role of the extracellular matrix in loss of muscle force with age and unloading using magnetic resonance imaging, biochemical analysis, and computational models. Front. Physiol. 11, 529329 (2020).","journal-title":"Front. Physiol."},{"key":"71817_CR7","unstructured":"Nishimura, D. G. Principles of magnetic resonance imaging (Stanford University, 1996)."},{"key":"71817_CR8","doi-asserted-by":"publisher","first-page":"192","DOI":"10.1002\/mrm.1910160203","volume":"16","author":"PB Roemer","year":"1990","unstructured":"Roemer, P. B., Edelstein, W. A., Hayes, C. E., Souza, S. P. & Mueller, O. M. The NMR phased array. Magn. Reson. Med. 16, 192\u2013225 (1990).","journal-title":"Magn. Reson. Med."},{"key":"71817_CR9","doi-asserted-by":"publisher","first-page":"12","DOI":"10.1002\/jmri.24159","volume":"38","author":"H Fujita","year":"2013","unstructured":"Fujita, H., Zheng, T., Yang, X., Finnerty, M. J. & Handa, S. RF surface receive array coils: the art of an LC circuit. J. Magn. Reson. Imaging 38, 12\u201325 (2013).","journal-title":"J. Magn. Reson. Imaging"},{"key":"71817_CR10","doi-asserted-by":"publisher","first-page":"75","DOI":"10.1016\/j.jmr.2013.02.001","volume":"229","author":"B Keil","year":"2013","unstructured":"Keil, B. & Wald, L. L. Massively parallel MRI detector arrays. J. Magn. Reson. 229, 75\u201389 (2013).","journal-title":"J. Magn. Reson."},{"key":"71817_CR11","doi-asserted-by":"publisher","first-page":"604","DOI":"10.1118\/1.595682","volume":"12","author":"CE Hayes","year":"1985","unstructured":"Hayes, C. E. & Axel, L. Noise performance of surface coils for magnetic resonance imaging at 1.5 T. Med. Phys. 12, 604\u2013607 (1985).","journal-title":"Med. Phys."},{"key":"71817_CR12","doi-asserted-by":"publisher","first-page":"952","DOI":"10.1002\/(SICI)1522-2594(199911)42:5<952::AID-MRM16>3.0.CO;2-S","volume":"42","author":"KP Pruessmann","year":"1999","unstructured":"Pruessmann, K. P., Weiger, M., Scheidegger, M. B. & Boesiger, P. SENSE: sensitivity encoding for fast MRI. Magn. Reson. Med. 42, 952\u2013962 (1999).","journal-title":"Magn. Reson. Med."},{"key":"71817_CR13","doi-asserted-by":"publisher","first-page":"591","DOI":"10.1002\/mrm.1910380414","volume":"38","author":"DK Sodickson","year":"1997","unstructured":"Sodickson, D. K. & Manning, W. J. Simultaneous acquisition of spatial harmonics (SMASH): fast imaging with radiofrequency coil arrays. Magn. Reson. Med. 38, 591\u2013603 (1997).","journal-title":"Magn. Reson. Med."},{"key":"71817_CR14","doi-asserted-by":"publisher","first-page":"81","DOI":"10.1002\/jmri.27411","volume":"55","author":"KS Nayak","year":"2022","unstructured":"Nayak, K. S., Lim, Y., Campbell-Washburn, A. E. & Steeden, J. Real-time magnetic resonance imaging. J. Magn. Reson. Imaging 55, 81\u201399 (2022).","journal-title":"J. Magn. Reson. Imaging"},{"key":"71817_CR15","doi-asserted-by":"publisher","first-page":"3071","DOI":"10.1002\/mrm.28337","volume":"84","author":"Y Tian","year":"2020","unstructured":"Tian, Y. et al. Whole-heart, ungated, free-breathing, cardiac-phase-resolved myocardial perfusion MRI using continuous radial interleaved simultaneous multi-slice acquisitions at spoiled steady state (CRIMP). Magn. Reson. Med. 84, 3071\u20133087 (2020).","journal-title":"Magn. Reson. Med."},{"key":"71817_CR16","doi-asserted-by":"publisher","DOI":"10.1038\/s41597-021-00976-x","volume":"8","author":"Y Lim","year":"2021","unstructured":"Lim, Y. et al. A multispeaker dataset of raw and reconstructed speech production real-time MRI video and 3D volumetric images. Sci. Data 8, 187 (2021).","journal-title":"Sci. Data"},{"key":"71817_CR17","doi-asserted-by":"publisher","first-page":"419","DOI":"10.1007\/s10334-022-01036-0","volume":"36","author":"F Mu\u00f1oz","year":"2022","unstructured":"Mu\u00f1oz, F., Lim, Y., Cui, S. X., Stark, H. & Nayak, K. S. Evaluation of a novel 8-channel RX coil for speech production MRI at 0.55 T. Magn. Reson. Mater. Phys. 36, 419\u2013426 (2022).","journal-title":"Magn. Reson. Mater. Phys."},{"key":"71817_CR18","first-page":"425","volume":"34","author":"DI Hoult","year":"1979","unstructured":"Hoult, D. I. & Lauterbur, P. C. The sensitivity of the zeugmatographic experiment involving human samples. J. Magn. Reson. 34, 425\u2013433 (1979).","journal-title":"J. Magn. Reson."},{"key":"71817_CR19","doi-asserted-by":"publisher","first-page":"494","DOI":"10.1002\/mrm.1910360327","volume":"36","author":"A Macovski","year":"1996","unstructured":"Macovski, A. Noise in MRI. Magn. Reson. Med. 36, 494\u2013497 (1996).","journal-title":"Magn. Reson. Med."},{"key":"71817_CR20","doi-asserted-by":"publisher","first-page":"195","DOI":"10.1002\/(SICI)1521-186X(1996)17:3<195::AID-BEM5>3.0.CO;2-Z","volume":"17","author":"CK Chou","year":"1996","unstructured":"Chou, C. K. et al. Radio frequency electromagnetic exposure: tutorial review on experimental dosimetry. Bioelectromagnetics 17, 195\u2013208 (1996).","journal-title":"Bioelectromagnetics"},{"key":"71817_CR21","doi-asserted-by":"publisher","first-page":"2364","DOI":"10.1002\/mrm.28278","volume":"84","author":"MC Restivo","year":"2020","unstructured":"Restivo, M. C., Ramasawmy, R., Bandettini, W. P., Herzka, D. A. & Campbell-Washburn, A. E. Efficient spiral in-out and EPI balanced steady-state free precession cine imaging using a high-performance 0.55T MRI. Magn. Reson. Med. 84, 2364\u20132375 (2020).","journal-title":"Magn. Reson. Med."},{"key":"71817_CR22","doi-asserted-by":"publisher","first-page":"1723","DOI":"10.1002\/mrm.30364","volume":"93","author":"E Yagiz","year":"2025","unstructured":"Yagiz, E., Garg, P., Cen, S. Y., Nayak, K. S. & Tian, Y. Simultaneous multi-slice cardiac real-time MRI at 0.55T. Magn. Reson. Med. 93, 1723\u20131732 (2025).","journal-title":"Magn. Reson. Med."},{"key":"71817_CR23","doi-asserted-by":"publisher","first-page":"101130","DOI":"10.1016\/j.jocmr.2024.101130","volume":"27","author":"Y Tian","year":"2025","unstructured":"Tian, Y. et al. Feasibility of fetal cardiac function and anatomy assessment by real-time spiral balanced steady-state free precession magnetic resonance imaging at 0.55T. J. Cardiovasc. Magn. Reson. 27, 101130 (2025).","journal-title":"J. Cardiovasc. Magn. Reson."},{"key":"71817_CR24","doi-asserted-by":"publisher","first-page":"337","DOI":"10.1002\/mrm.29843","volume":"91","author":"Y Lim","year":"2024","unstructured":"Lim, Y., Kumar, P. & Nayak, K. S. Speech production real-time MRI at 0.55T. Magn. Reson. Med. 91, 337\u2013343 (2024).","journal-title":"Magn. Reson. Med."},{"key":"71817_CR25","doi-asserted-by":"publisher","first-page":"2648","DOI":"10.1002\/jmri.29785","volume":"61","author":"Y Tian","year":"2025","unstructured":"Tian, Y., Chaudhari, A. J. & Nayak, K. S. Three dimensional real-time MRI for the comprehensive evaluation of wrist kinematics. J. Magn. Reson. Imaging 61, 2648\u20132651 (2025).","journal-title":"J. Magn. Reson. Imaging"},{"key":"71817_CR26","first-page":"71","volume":"24","author":"DI Hoult","year":"1976","unstructured":"Hoult, D. I. & Richards, R. E. The signal-to-noise ratio of the nuclear magnetic resonance experiment. J. Magn. Reson. 24, 71\u201385 (1976).","journal-title":"J. Magn. Reson."},{"key":"71817_CR27","doi-asserted-by":"publisher","first-page":"2186","DOI":"10.1002\/mrm.30428","volume":"93","author":"TV Ramesh","year":"2025","unstructured":"Ramesh, T. V., Narongrit, F. W. & Rispoli, J. V. Adaptable, wearable, and stretchable coils: a review. Magn. Reson. Med. 93, 2186\u20132208 (2025).","journal-title":"Magn. Reson. Med."},{"key":"71817_CR28","doi-asserted-by":"publisher","first-page":"1026","DOI":"10.1002\/jmri.27865","volume":"55","author":"D Darnell","year":"2022","unstructured":"Darnell, D., Truong, T. K. & Song, A. W. Recent advances in radio-frequency coil technologies: flexible, wireless, and integrated coil arrays. J. Magn. Reson. Imaging 55, 1026\u20131042 (2022).","journal-title":"J. Magn. Reson. Imaging"},{"key":"71817_CR29","doi-asserted-by":"publisher","first-page":"570","DOI":"10.1038\/s41551-018-0233-y","volume":"2","author":"B Zhang","year":"2018","unstructured":"Zhang, B., Sodickson, D. K. & Cloos, M. A. A high-impedance detector-array glove for magnetic resonance imaging of the hand. Nat. Biomed. Eng. 2, 570\u2013577 (2018).","journal-title":"Nat. Biomed. Eng."},{"key":"71817_CR30","doi-asserted-by":"crossref","unstructured":"Zi, R. et al. High-resolution volumetric dynamic magnetic resonance imaging of the wrist using an 8-channel flexible receive coil. Skeletal Radiol. 54, 1291\u20131299 (2024).","DOI":"10.1007\/s00256-024-04829-7"},{"key":"71817_CR31","doi-asserted-by":"publisher","first-page":"120","DOI":"10.1006\/jmra.1996.0187","volume":"122","author":"A Stensgaard","year":"1996","unstructured":"Stensgaard, A. Optimized design of the shielded-loop resonator. J. Magn. Reson. A 122, 120\u2013125 (1996).","journal-title":"J. Magn. Reson. A"},{"key":"71817_CR32","doi-asserted-by":"publisher","first-page":"1135","DOI":"10.1002\/mrm.27964","volume":"83","author":"T Ruytenberg","year":"2020","unstructured":"Ruytenberg, T., Webb, A. & Zivkovic, I. Shielded-coaxial-cable coils as receive and transceive array elements for 7 T human MRI. Magn. Reson. Med. 83, 1135\u20131146 (2020).","journal-title":"Magn. Reson. Med."},{"key":"71817_CR33","doi-asserted-by":"publisher","DOI":"10.1038\/s41598-022-19282-6","volume":"12","author":"B Wang","year":"2022","unstructured":"Wang, B. et al. A flexible MRI coil based on a cable conductor applied to knee imaging. Sci. Rep. 12, 15010 (2022).","journal-title":"Sci. Rep."},{"key":"71817_CR34","doi-asserted-by":"crossref","unstructured":"Maravilla, J. A., Lustig, M. & Arias, A. C. Twstr: a resonant, matched MRI coil without any discrete components. In Proc. IEEE MTT-S Int. Microw. Biomed. Conf. 128\u2013130 (2024).","DOI":"10.1109\/IMBioC60287.2024.10590497"},{"key":"71817_CR35","doi-asserted-by":"publisher","first-page":"146","DOI":"10.1016\/j.mri.2024.02.007","volume":"108","author":"J Vliem","year":"2024","unstructured":"Vliem, J. et al. Twisted pair transmission line coil: a flexible, self-decoupled and robust element for 7 T MRI. Magn. Reson. Imaging 108, 146\u2013160 (2024).","journal-title":"Magn. Reson. Imaging"},{"key":"71817_CR36","doi-asserted-by":"publisher","first-page":"1219","DOI":"10.1002\/jmri.21463","volume":"28","author":"CJ Hardy","year":"2008","unstructured":"Hardy, C. J. et al. 128-channel body MRI with a flexible high-density receiver-coil array. J. Magn. Reson. Imaging 28, 1219\u20131225 (2008).","journal-title":"J. Magn. Reson. Imaging"},{"key":"71817_CR37","doi-asserted-by":"publisher","first-page":"590","DOI":"10.1002\/mrm.21488","volume":"59","author":"G Adriany","year":"2008","unstructured":"Adriany, G. et al. A geometrically adjustable 16-channel transmit\/receive transmission line array for improved RF efficiency and parallel imaging performance at 7 tesla. Magn. Reson. Med. 59, 590\u2013597 (2008).","journal-title":"Magn. Reson. Med."},{"key":"71817_CR38","doi-asserted-by":"publisher","first-page":"429","DOI":"10.1002\/mrm.21868","volume":"61","author":"JA Nordmeyer-Massner","year":"2009","unstructured":"Nordmeyer-Massner, J. A., De Zanche, N. & Pruessmann, K. P. Mechanically adjustable coil array for wrist MRI. Magn. Reson. Med. 61, 429\u2013438 (2009).","journal-title":"Magn. Reson. Med."},{"key":"71817_CR39","doi-asserted-by":"publisher","first-page":"482","DOI":"10.1109\/TMI.2009.2036996","volume":"29","author":"D Mager","year":"2010","unstructured":"Mager, D. et al. An MRI receiver coil produced by inkjet printing directly on to a flexible substrate. IEEE Trans. Med. Imaging 29, 482\u2013487 (2010).","journal-title":"IEEE Trans. Med. Imaging"},{"key":"71817_CR40","doi-asserted-by":"publisher","first-page":"1332","DOI":"10.1002\/mrm.24121","volume":"68","author":"B Wu","year":"2012","unstructured":"Wu, B. et al. Flexible transceiver array for ultrahigh field human MR imaging. Magn. Reson. Med. 68, 1332\u20131338 (2012).","journal-title":"Magn. Reson. Med."},{"key":"71817_CR41","doi-asserted-by":"publisher","first-page":"1669","DOI":"10.1002\/mrm.25260","volume":"73","author":"R Kriegl","year":"2015","unstructured":"Kriegl, R. et al. Novel inductive decoupling technique for flexible transceiver arrays of monolithic transmission line resonators. Magn. Reson. Med. 73, 1669\u20131681 (2015).","journal-title":"Magn. Reson. Med."},{"key":"71817_CR42","doi-asserted-by":"publisher","first-page":"47","DOI":"10.1016\/j.jmr.2018.08.013","volume":"296","author":"S Hosseinnezhadian","year":"2018","unstructured":"Hosseinnezhadian, S. et al. A flexible 12-channel transceiver array of transmission line resonators for 7 T MRI. J. Magn. Reson. 296, 47\u201359 (2018).","journal-title":"J. Magn. Reson."},{"key":"71817_CR43","doi-asserted-by":"publisher","first-page":"460","DOI":"10.1002\/nbm.3264","volume":"28","author":"F Jia","year":"2015","unstructured":"Jia, F. et al. Knee MRI under varying flexion angles utilizing a flexible flat cable antenna. NMR Biomed. 28, 460\u2013467 (2015).","journal-title":"NMR Biomed."},{"key":"71817_CR44","doi-asserted-by":"publisher","first-page":"e3944","DOI":"10.1002\/nbm.3944","volume":"31","author":"N Lopez Rios","year":"2018","unstructured":"Lopez Rios, N., Foias, A., Lodygensky, G., Dehaes, M. & Cohen-Adad, J. Size-adaptable 13-channel receive array for brain MRI in human neonates at 3 T. NMR Biomed. 31, e3944 (2018).","journal-title":"NMR Biomed."},{"key":"71817_CR45","doi-asserted-by":"publisher","DOI":"10.1038\/ncomms10839","volume":"7","author":"JR Corea","year":"2016","unstructured":"Corea, J. R. et al. Screen-printed flexible MRI receive coils. Nat. Commun. 7, 10839 (2016).","journal-title":"Nat. Commun."},{"key":"71817_CR46","doi-asserted-by":"publisher","first-page":"180","DOI":"10.1148\/radiol.2019181883","volume":"291","author":"SA Winkler","year":"2019","unstructured":"Winkler, S. A. et al. Evaluation of a flexible 12-channel screen-printed pediatric MRI coil. Radiology 291, 180\u2013185 (2019).","journal-title":"Radiology"},{"key":"71817_CR47","doi-asserted-by":"publisher","first-page":"1542","DOI":"10.1109\/TBME.2018.2875436","volume":"66","author":"A Mehmann","year":"2018","unstructured":"Mehmann, A. et al. On the bending and stretching of liquid metal receive coils for magnetic resonance imaging. IEEE Trans. Biomed. Eng. 66, 1542\u20131548 (2018).","journal-title":"IEEE Trans. Biomed. Eng."},{"key":"71817_CR48","doi-asserted-by":"publisher","first-page":"1703744","DOI":"10.1002\/adma.201703744","volume":"29","author":"M Varga","year":"2017","unstructured":"Varga, M. et al. Adsorbed eutectic GaIn structures on a neoprene foam for stretchable MRI coils. Adv. Mater. 29, 1703744 (2017).","journal-title":"Adv. Mater."},{"key":"71817_CR49","doi-asserted-by":"publisher","DOI":"10.1038\/s41598-021-95335-6","volume":"11","author":"E Motovilova","year":"2021","unstructured":"Motovilova, E. et al. Stretchable self-tuning MRI receive coils based on liquid metal technology (liquitune). Sci. Rep. 11, 16733 (2021).","journal-title":"Sci. Rep."},{"key":"71817_CR50","first-page":"246","volume":"7","author":"JA Malko","year":"1986","unstructured":"Malko, J. A., McClees, E. C., Braun, I. F., Davis, P. C. & Hoffman, J. C. A flexible mercury-filled surface coil for MR imaging. AJNR Am. J. Neuroradiol. 7, 246 (1986).","journal-title":"AJNR Am. J. Neuroradiol."},{"key":"71817_CR51","doi-asserted-by":"publisher","DOI":"10.1038\/s41598-020-65634-5","volume":"10","author":"A Port","year":"2020","unstructured":"Port, A. et al. Detector clothes for MRI: a wearable array receiver based on liquid metal in elastic tubes. Sci. Rep. 10, 8844 (2020).","journal-title":"Sci. Rep."},{"key":"71817_CR52","doi-asserted-by":"publisher","first-page":"2187","DOI":"10.1109\/TBME.2019.2956682","volume":"67","author":"JM Vincent","year":"2020","unstructured":"Vincent, J. M. & Rispoli, J. V. Conductive thread-based stretchable and flexible radiofrequency coils for magnetic resonance imaging. IEEE Trans. Biomed. Eng. 67, 2187\u20132193 (2020).","journal-title":"IEEE Trans. Biomed. Eng."},{"key":"71817_CR53","doi-asserted-by":"publisher","first-page":"5115","DOI":"10.1109\/TAP.2019.2891700","volume":"67","author":"D Zhang","year":"2019","unstructured":"Zhang, D. & Rahmat-Samii, Y. A novel flexible electrotextile 3T MRI RF coil array for carotid artery imaging: design, characterization, and prototyping. IEEE Trans. Antennas Propag. 67, 5115\u20135125 (2019).","journal-title":"IEEE Trans. Antennas Propag."},{"key":"71817_CR54","doi-asserted-by":"publisher","first-page":"517","DOI":"10.1109\/LMWC.2021.3068930","volume":"31","author":"B Kahraman-Agir","year":"2021","unstructured":"Kahraman-Agir, B., Yegin, K. & Ozturk-Isik, E. Wearable and elastic surface coil for 1H magnetic resonance imaging. IEEE Microw. Wirel. Compon. Lett. 31, 517\u2013520 (2021).","journal-title":"IEEE Microw. Wirel. Compon. Lett."},{"key":"71817_CR55","doi-asserted-by":"publisher","first-page":"89613","DOI":"10.1109\/ACCESS.2024.3416869","volume":"12","author":"FW Narongrit","year":"2024","unstructured":"Narongrit, F. W., Ramesh, T. V. & Rispoli, J. V. Stretching the limits of MRI: stretchable and modular coil array using conductive thread technology. IEEE Access 12, 89613\u201389620 (2024).","journal-title":"IEEE Access"},{"key":"71817_CR56","unstructured":"Fujimoto, K. et al. A tight-fit flexible high-impedance coil array for high-resolution imaging of small ex-vivo specimen using a human 7 T scanner. In Proc. Int. Soc. Magn. Reson. Med. 4018 (2020)."},{"key":"71817_CR57","doi-asserted-by":"publisher","first-page":"129754","DOI":"10.1109\/ACCESS.2020.3009367","volume":"8","author":"MSM Mollaei","year":"2020","unstructured":"Mollaei, M. S. M., van Leeuwen, C. C., Raaijmakers, A. J. E. & Simovski, C. R. Analysis of high impedance coils both in transmission and reception regimes. IEEE Access 8, 129754\u2013129762 (2020).","journal-title":"IEEE Access"},{"key":"71817_CR58","doi-asserted-by":"publisher","first-page":"1267","DOI":"10.1109\/TMI.2021.3051390","volume":"40","author":"L Nohava","year":"2021","unstructured":"Nohava, L. et al. Flexible multi-turn multi-gap coaxial RF coils: design concept and implementation for magnetic resonance imaging at 3 and 7 tesla. IEEE Trans. Med. Imaging 40, 1267\u20131278 (2021).","journal-title":"IEEE Trans. Med. Imaging"},{"key":"71817_CR59","unstructured":"Rudin, M. (ed.) In-vivo magnetic resonance spectroscopy I: probeheads and radiofrequency pulses spectrum analysis (Springer, 2012)."},{"key":"71817_CR60","doi-asserted-by":"publisher","first-page":"915","DOI":"10.1016\/j.biochi.2003.09.016","volume":"85","author":"L Darrasse","year":"2003","unstructured":"Darrasse, L. & Ginefri, J.-C. Perspectives with cryogenic RF probes in biomedical MRI. Biochimie 85, 915\u2013937 (2003).","journal-title":"Biochimie"},{"key":"71817_CR61","doi-asserted-by":"publisher","first-page":"085303","DOI":"10.1088\/1361-6528\/ab5419","volume":"31","author":"S Chun","year":"2019","unstructured":"Chun, S. et al. Serpentine-pattern effects on the biaxial stretching of percolative graphene nanoflake films. Nanotechnology 31, 085303 (2019).","journal-title":"Nanotechnology"},{"key":"71817_CR62","doi-asserted-by":"publisher","first-page":"1005","DOI":"10.1002\/jmri.23845","volume":"37","author":"CL Hayter","year":"2013","unstructured":"Hayter, C. L., Gold, S. L. & Potter, H. G. Magnetic resonance imaging of the wrist: bone and cartilage injury. J. Magn. Reson. Imaging 37, 1005\u20131019 (2013).","journal-title":"J. Magn. Reson. Imaging"},{"key":"71817_CR63","doi-asserted-by":"crossref","unstructured":"Chaudhari, A. J. et al. Real-time MRI of the moving wrist at 0.55 tesla. Br. J. Radiol. 96, 20220671 (2023).","DOI":"10.1259\/bjr.20230298"},{"key":"71817_CR64","doi-asserted-by":"publisher","first-page":"998","DOI":"10.1016\/j.jhsa.2008.04.027","volume":"33","author":"CE Kuo","year":"2008","unstructured":"Kuo, C. E. & Wolfe, S. W. Scapholunate instability: current concepts in diagnosis and management. J. Hand Surg. Am. 33, 998\u20131013 (2008).","journal-title":"J. Hand Surg. Am."},{"key":"71817_CR65","doi-asserted-by":"publisher","first-page":"1262","DOI":"10.2106\/00004623-198870080-00025","volume":"70","author":"J Taleisnik","year":"1988","unstructured":"Taleisnik, J. Carpal instability. J. Bone Jt. Surg. Am. 70, 1262\u20131268 (1988).","journal-title":"J. Bone Jt. Surg. Am."},{"key":"71817_CR66","doi-asserted-by":"publisher","first-page":"2161","DOI":"10.1007\/s00330-006-0161-1","volume":"16","author":"R Schmitt","year":"2006","unstructured":"Schmitt, R., Froehner, S., Coblenz, G. & Christopoulos, G. Carpal instability. Eur. Radiol. 16, 2161\u20132178 (2006).","journal-title":"Eur. Radiol."},{"key":"71817_CR67","doi-asserted-by":"publisher","first-page":"382","DOI":"10.1302\/2058-5241.2.170016","volume":"2","author":"JK Andersson","year":"2017","unstructured":"Andersson, J. K. Treatment of scapholunate ligament injury: current concepts. EFORT Open Rev. 2, 382\u2013393 (2017).","journal-title":"EFORT Open Rev."},{"key":"71817_CR68","doi-asserted-by":"publisher","first-page":"727","DOI":"10.1177\/1753193412473861","volume":"38","author":"RJR Chennagiri","year":"2013","unstructured":"Chennagiri, R. J. R. & Lindau, T. R. Assessment of scapholunate instability and review of evidence for management in the absence of arthritis. J. Hand Surg. Eur. 38, 727\u2013738 (2013).","journal-title":"J. Hand Surg. Eur."},{"key":"71817_CR69","doi-asserted-by":"publisher","first-page":"261","DOI":"10.1016\/j.ocl.2007.02.003","volume":"38","author":"J Manuel","year":"2007","unstructured":"Manuel, J. & Moran, S. L. The diagnosis and treatment of scapholunate instability. Orthop. Clin. North Am. 38, 261\u2013277 (2007).","journal-title":"Orthop. Clin. North Am."},{"key":"71817_CR70","doi-asserted-by":"publisher","first-page":"791","DOI":"10.1007\/s00256-023-04466-6","volume":"53","author":"LM Wilms","year":"2024","unstructured":"Wilms, L. M. et al. Dynamic assessment of scapholunate ligament status by real-time magnetic resonance imaging: an exploratory clinical study. Skelet. Radiol. 53, 791\u2013800 (2024).","journal-title":"Skelet. Radiol."},{"key":"71817_CR71","first-page":"23","volume":"19","author":"GCMRRG Investigators","year":"2017","unstructured":"Investigators, G. C. M. R. R. G. et al. The global cardiovascular magnetic resonance registry (GCMR) of the society for cardiovascular magnetic resonance (SCMR): its goals, rationale, data infrastructure, and current developments. J. Cardiovasc. Magn. Reson. 19, 23 (2017).","journal-title":"J. Cardiovasc. Magn. Reson."},{"key":"71817_CR72","doi-asserted-by":"publisher","first-page":"649","DOI":"10.1002\/mrm.29885","volume":"91","author":"Y Tian","year":"2024","unstructured":"Tian, Y. & Nayak, K. S. Real-time water\/fat imaging at 0.55 T with spiral out-in-out-in sampling. Magn. Reson. Med. 91, 649\u2013659 (2024).","journal-title":"Magn. Reson. Med."},{"key":"71817_CR73","doi-asserted-by":"publisher","first-page":"315","DOI":"10.1002\/marc.200400445","volume":"26","author":"AL Dearden","year":"2005","unstructured":"Dearden, A. L. et al. A low curing temperature silver ink for use in ink-jet printing and subsequent production of conductive tracks. Macromol. Rapid Commun. 26, 315\u2013318 (2005).","journal-title":"Macromol. Rapid Commun."},{"key":"71817_CR74","doi-asserted-by":"crossref","unstructured":"NanoVNA Authors. Nanovna v2-f https:\/\/github.com\/nanovna\/nanovna-v2 (2005).","DOI":"10.1049\/cp:20050418"},{"key":"71817_CR75","unstructured":"Mispelter, J., Lupu, M. & Briguet, A. NMR probeheads for biophysical and biomedical experiments: theoretical principles and practical guidelines (World Scientific, 2015)."},{"key":"71817_CR76","unstructured":"Taracila, V., Chan, P. & Robb, F. Minimal acceptable blocking impedance for RF receive coils. In Proc. Int. Soc. Magn. Reson. Med. 18 (2010)."},{"key":"71817_CR77","doi-asserted-by":"publisher","first-page":"80","DOI":"10.1007\/BF02601842","volume":"10","author":"A Kocharian","year":"2000","unstructured":"Kocharian, A. et al. Determination of appropriate RF blocking impedance for MRI surface coils and arrays. Magn. Reson. Mater. Phys. 10, 80\u201383 (2000).","journal-title":"Magn. Reson. Mater. Phys."},{"key":"71817_CR78","unstructured":"Broberg, R. B. Nanovnasaver: a multiplatform tool to save and process touchstone files from the nanovna. GitHub https:\/\/github.com\/NanoVNA-Saver\/nanovna-saver (2025)."},{"key":"71817_CR79","doi-asserted-by":"publisher","first-page":"88","DOI":"10.1109\/MMM.2022.3233500","volume":"24","author":"N Hunt","year":"2023","unstructured":"Hunt, N., Scott, J. & Streeter, L. Nano versus commercial. IEEE Microw. Mag. 24, 88\u201395 (2023).","journal-title":"IEEE Microw. Mag."},{"key":"71817_CR80","doi-asserted-by":"publisher","first-page":"1439","DOI":"10.1002\/mrm.20713","volume":"54","author":"P Kellman","year":"2005","unstructured":"Kellman, P. & McVeigh, E. R. Image reconstruction in SNR units: a general method for SNR measurement. Magn. Reson. Med. 54, 1439\u20131447 (2005).","journal-title":"Magn. Reson. Med."}],"container-title":["Nature Communications"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.nature.com\/articles\/s41467-026-71817-x","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.nature.com\/articles\/s41467-026-71817-x.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.nature.com\/articles\/s41467-026-71817-x.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,6,22]],"date-time":"2026-06-22T00:02:21Z","timestamp":1782086541000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.nature.com\/articles\/s41467-026-71817-x"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,4,20]]},"references-count":80,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2026,12]]}},"alternative-id":["71817"],"URL":"https:\/\/doi.org\/10.1038\/s41467-026-71817-x","relation":{},"ISSN":["2041-1723"],"issn-type":[{"value":"2041-1723","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,4,20]]},"assertion":[{"value":"19 September 2025","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"31 March 2026","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"20 April 2026","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"The authors declare no competing interests.","order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"5470"}}