{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,15]],"date-time":"2026-10-15T04:41:03Z","timestamp":1792039263359,"version":"4.4.0"},"reference-count":34,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2026,5,14]],"date-time":"2026-05-14T00:00:00Z","timestamp":1778716800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0"},{"start":{"date-parts":[[2026,7,17]],"date-time":"2026-07-17T00:00:00Z","timestamp":1784246400000},"content-version":"vor","delay-in-days":64,"URL":"https:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0"}],"funder":[{"DOI":"10.13039\/100000001","name":"National Science Foundation","doi-asserted-by":"publisher","award":["2139322"],"award-info":[{"award-number":["2139322"]}],"id":[{"id":"10.13039\/100000001","id-type":"DOI","asserted-by":"publisher"}]},{"DOI":"10.13039\/100000001","name":"National Science Foundation","doi-asserted-by":"publisher","award":["2136198"],"award-info":[{"award-number":["2136198"]}],"id":[{"id":"10.13039\/100000001","id-type":"DOI","asserted-by":"publisher"}]},{"DOI":"10.13039\/100000001","name":"National Science Foundation","doi-asserted-by":"publisher","award":["2529648"],"award-info":[{"award-number":["2529648"]}],"id":[{"id":"10.13039\/100000001","id-type":"DOI","asserted-by":"publisher"}]},{"DOI":"10.13039\/100000054","name":"U.S. Department of Health & Human Services | NIH | National Cancer Institute","doi-asserted-by":"publisher","award":["1R21CA273984- 01A1"],"award-info":[{"award-number":["1R21CA273984- 01A1"]}],"id":[{"id":"10.13039\/100000054","id-type":"DOI","asserted-by":"publisher"}]},{"DOI":"10.13039\/100000054","name":"U.S. Department of Health & Human Services | NIH | National Cancer Institute","doi-asserted-by":"publisher","award":["1P01CA285249-01A1"],"award-info":[{"award-number":["1P01CA285249-01A1"]}],"id":[{"id":"10.13039\/100000054","id-type":"DOI","asserted-by":"publisher"}]},{"DOI":"10.13039\/100000054","name":"U.S. Department of Health & Human Services | NIH | National Cancer Institute","doi-asserted-by":"publisher","award":["1R21CA289101-01A1"],"award-info":[{"award-number":["1R21CA289101-01A1"]}],"id":[{"id":"10.13039\/100000054","id-type":"DOI","asserted-by":"publisher"}]},{"DOI":"10.13039\/100006545","name":"U.S. Department of Health & Human Services | NIH | National Institute on Minority Health and Health Disparities","doi-asserted-by":"publisher","award":["1R21MD018488-01A1"],"award-info":[{"award-number":["1R21MD018488-01A1"]}],"id":[{"id":"10.13039\/100006545","id-type":"DOI","asserted-by":"publisher"}]},{"name":"B-Secur, Ltd"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Nat Commun"],"DOI":"10.1038\/s41467-026-72693-1","type":"journal-article","created":{"date-parts":[[2026,5,14]],"date-time":"2026-05-14T06:55:11Z","timestamp":1778741711000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":3,"title":["Cuffless hemodynamic monitoring with physics-informed machine learning models"],"prefix":"10.1038","volume":"17","author":[{"given":"Henry","family":"Crandall","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Tyler","family":"Schuessler","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0009-0004-0500-7583","authenticated-orcid":false,"given":"Filip","family":"B\u011bl\u00edk","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0009-0009-4222-9261","authenticated-orcid":false,"given":"Albert","family":"Fabregas","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Barry M.","family":"Stults","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Alexandra","family":"Boyadzhiev","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Huanan","family":"Zhang","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jim S.","family":"Wu","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-9202-2378","authenticated-orcid":false,"given":"Aylin R.","family":"Rodan","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-4168-2696","authenticated-orcid":false,"given":"Stephen P.","family":"Juraschek","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-8918-4050","authenticated-orcid":false,"given":"Ramakrishna","family":"Mukkamala","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Alfred K.","family":"Cheung","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-1223-327X","authenticated-orcid":false,"given":"Stavros G.","family":"Drakos","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Christel","family":"Hohenegger","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Braxton","family":"Osting","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-1594-9847","authenticated-orcid":false,"given":"Benjamin","family":"Sanchez","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2026,5,14]]},"reference":[{"key":"72693_CR1","doi-asserted-by":"publisher","first-page":"285","DOI":"10.1161\/HYPERTENSIONAHA.119.14240","volume":"75","author":"FD Fuchs","year":"2020","unstructured":"Fuchs, F. D. & Whelton, P. K. High blood pressure and cardiovascular disease. Hypertension 75, 285\u2013292 (2020).","journal-title":"Hypertension"},{"key":"72693_CR2","doi-asserted-by":"publisher","first-page":"957","DOI":"10.1016\/S0140-6736(21)01330-1","volume":"398","author":"B Zhou","year":"2021","unstructured":"Zhou, B. Worldwide trends in hypertension prevalence and progress in treatment and control from 1990 to 2019: a pooled analysis of 1201 population-representative studies with 104 million participants. Lancet 398, 957\u2013980 (2021).","journal-title":"Lancet"},{"key":"72693_CR3","doi-asserted-by":"publisher","first-page":"e020817","DOI":"10.1161\/JAHA.121.020817","volume":"10","author":"A Briasoulis","year":"2021","unstructured":"Briasoulis, A. & Alvarez, P. Is ambulatory hemodynamic monitoring beneficial to patients with advanced heart failure? J. Am. Heart Assoc. 10, e020817 (2021).","journal-title":"J. Am. Heart Assoc."},{"key":"72693_CR4","doi-asserted-by":"publisher","first-page":"556","DOI":"10.1001\/jamacardio.2019.1384","volume":"4","author":"J Abraham","year":"2019","unstructured":"Abraham, J. et al. Association of ambulatory hemodynamic monitoring of heart failure with clinical outcomes in a concurrent matched cohort analysis. JAMA Cardiol. 4, 556 (2019).","journal-title":"JAMA Cardiol."},{"key":"72693_CR5","doi-asserted-by":"publisher","first-page":"2357","DOI":"10.1016\/j.jacc.2017.03.009","volume":"69","author":"AS Desai","year":"2017","unstructured":"Desai, A. S. et al. Ambulatory hemodynamic monitoring reduces heart failure hospitalizations in \u201creal-world\u201d clinical practice. J. Am. Coll. Cardiol. 69, 2357\u20132365 (2017).","journal-title":"J. Am. Coll. Cardiol."},{"key":"72693_CR6","doi-asserted-by":"publisher","first-page":"1665","DOI":"10.1097\/HJH.0000000000000969","volume":"34","author":"GS Stergiou","year":"2016","unstructured":"Stergiou, G. S. et al. Methodology and technology for peripheral and central blood pressure and blood pressure variability measurement: current status and future directions - position statement of the european society of hypertension working group on blood pressure monitoring and cardiovascular variability. J. Hypertens. 34, 1665\u20131677 (2016).","journal-title":"J. Hypertens."},{"key":"72693_CR7","doi-asserted-by":"publisher","first-page":"1139","DOI":"10.1007\/s11886-023-01932-4","volume":"25","author":"J-R Hu","year":"2023","unstructured":"Hu, J.-R. et al. The promise and illusion of continuous, cuffless blood pressure monitoring. Curr. Cardiol. Rep. 25, 1139\u20131149 (2023).","journal-title":"Curr. Cardiol. Rep."},{"key":"72693_CR8","doi-asserted-by":"publisher","first-page":"640","DOI":"10.1161\/HYPERTENSIONAHA.120.14742","volume":"76","author":"K Kario","year":"2020","unstructured":"Kario, K. Management of hypertension in the digital era: small wearable monitoring devices for remote blood pressure monitoring. Hypertension 76, 640\u2013650 (2020).","journal-title":"Hypertension"},{"key":"72693_CR9","doi-asserted-by":"crossref","unstructured":"Benjamin, E. J. et al. Heart disease and stroke statistics\u20132019 update: a report from the american heart association. Circulation 139, e56\u2013e528 (2019).","DOI":"10.1161\/CIR.0000000000000659"},{"key":"72693_CR10","doi-asserted-by":"publisher","DOI":"10.1038\/s41746-023-00835-6","volume":"6","author":"L Zhao","year":"2023","unstructured":"Zhao, L. et al. Emerging sensing and modeling technologies for wearable and cuffless blood pressure monitoring. npj Digital Med. 6, 93 (2023).","journal-title":"npj Digital Med."},{"key":"72693_CR11","doi-asserted-by":"crossref","unstructured":"Min, S. et al. Wearable blood pressure sensors for cardiovascular monitoring and machine learning algorithms for blood pressure estimation. Nat. Rev. Cardiol. 22, 629\u2013648 (2025).","DOI":"10.1038\/s41569-025-01127-0"},{"key":"72693_CR12","doi-asserted-by":"crossref","unstructured":"Lopez-Jimenez, F. et al. Development and internal validation of an ai-enabled cuff-less, non-invasive continuous blood pressure monitor across all classes of hypertension. J. Cardiovasc. Transl. Res. 18, 280\u2013290 (2025).","DOI":"10.1007\/s12265-024-10589-5"},{"key":"72693_CR13","doi-asserted-by":"crossref","unstructured":"Berlot, A. A. et al. Remote blood pressure monitoring: a comprehensive review. Am. J. Hypertens. 39, 188\u2013197 (2025).","DOI":"10.1093\/ajh\/hpaf097"},{"key":"72693_CR14","doi-asserted-by":"publisher","first-page":"472","DOI":"10.1097\/HJH.0000000000001634","volume":"36","author":"GS Stergiou","year":"2018","unstructured":"Stergiou, G. S. et al. A universal standard for the validation of blood pressure measuring devices. J. Hypertens. 36, 472\u2013478 (2018).","journal-title":"J. Hypertens."},{"key":"72693_CR15","doi-asserted-by":"publisher","first-page":"721","DOI":"10.1109\/TBME.2007.903531","volume":"55","author":"RL Gaw","year":"2008","unstructured":"Gaw, R. L., Cornish, B. H. & Thomas, B. J. The electrical impedance of pulsatile blood flowing through rigid tubes: A theoretical investigation. IEEE Trans. Biomed. Eng. 55, 721\u2013727 (2008).","journal-title":"IEEE Trans. Biomed. Eng."},{"key":"72693_CR16","doi-asserted-by":"crossref","unstructured":"Zamir, M. The physics of pulsatile flow. In Biological Physics Series (Springer Nature, 2000).","DOI":"10.1007\/978-1-4612-1282-9"},{"key":"72693_CR17","doi-asserted-by":"publisher","first-page":"1251","DOI":"10.1109\/TBME.2004.827263","volume":"51","author":"AE Hoetink","year":"2004","unstructured":"Hoetink, A. E., Faes, T. J., Visser, K. R. & Heethaar, R. M. On the flow dependency of the electrical conductivity of blood. IEEE Trans. Biomed. Eng. 51, 1251\u20131261 (2004).","journal-title":"IEEE Trans. Biomed. Eng."},{"key":"72693_CR18","doi-asserted-by":"publisher","first-page":"1281","DOI":"10.1114\/1.1326031","volume":"28","author":"MS Olufsen","year":"2000","unstructured":"Olufsen, M. S. et al. Numerical simulation and experimental validation of blood flow in arteries with structured-tree outflow conditions. Ann. Biomed. Eng. 28, 1281\u20131299 (2000).","journal-title":"Ann. Biomed. Eng."},{"key":"72693_CR19","doi-asserted-by":"publisher","first-page":"5287","DOI":"10.1088\/0031-9155\/59\/18\/5287","volume":"59","author":"M-C Gosselin","year":"2014","unstructured":"Gosselin, M.-C. et al. Development of a new generation of high-resolution anatomical models for medical device evaluation: the virtual population 3.0. Phys. Med. Biol. 59, 5287\u20135303 (2014).","journal-title":"Phys. Med. Biol."},{"key":"72693_CR20","doi-asserted-by":"publisher","first-page":"1026","DOI":"10.1126\/science.aaw4741","volume":"367","author":"M Raissi","year":"2020","unstructured":"Raissi, M., Yazdani, A. & Karniadakis, G. E. Hidden fluid mechanics: learning velocity and pressure fields from flow visualizations. Science 367, 1026\u20131030 (2020).","journal-title":"Science"},{"key":"72693_CR21","doi-asserted-by":"publisher","first-page":"686","DOI":"10.1016\/j.jcp.2018.10.045","volume":"378","author":"M Raissi","year":"2019","unstructured":"Raissi, M., Perdikaris, P. & Karniadakis, G. Physics-informed neural networks: A deep learning framework for solving forward and inverse problems involving nonlinear partial differential equations. J. Comput. Phys. 378, 686\u2013707 (2019).","journal-title":"J. Comput. Phys."},{"key":"72693_CR22","doi-asserted-by":"publisher","first-page":"1090854","DOI":"10.3389\/fdgth.2022.1090854","volume":"4","author":"W Wang","year":"2023","unstructured":"Wang, W., Mohseni, P., Kilgore, K. L. & Najafizadeh, L. Pulsedb: A large, cleaned dataset based on mimic-iii and vitaldb for benchmarking cuff-less blood pressure estimation methods. Front. Digital Health 4, 1090854 (2023).","journal-title":"Front. Digital Health"},{"key":"72693_CR23","doi-asserted-by":"crossref","unstructured":"Zhou, S. et al. Clinical validation of a wearable ultrasound sensor of blood pressure. Nat. Biomed. Eng. 9, 865\u2013881 (2024).","DOI":"10.1038\/s41551-024-01279-3"},{"key":"72693_CR24","doi-asserted-by":"publisher","first-page":"2103","DOI":"10.1056\/NEJMoa1511939","volume":"373","author":"SR Group","year":"2015","unstructured":"Group, S. R. et al. A randomized trial of intensive versus standard blood-pressure control. N. Engl. J. Med. 373, 2103\u20132116 (2015).","journal-title":"N. Engl. J. Med."},{"key":"72693_CR25","doi-asserted-by":"publisher","first-page":"245","DOI":"10.1016\/S0140-6736(24)01028-6","volume":"404","author":"J Liu","year":"2024","unstructured":"Liu, J. et al. Lowering systolic blood pressure to less than 120 mm hg versus less than 140 mm hg in patients with high cardiovascular risk with and without diabetes or previous stroke: an open-label, blinded-outcome, randomised trial. Lancet 404, 245\u2013255 (2024).","journal-title":"Lancet"},{"key":"72693_CR26","doi-asserted-by":"publisher","DOI":"10.1038\/s41467-025-64275-4","volume":"16","author":"AC Miller","year":"2025","unstructured":"Miller, A. C. et al. A wearable-based aging clock associates with disease and behavior. Nat. Commun. 16, 9264 (2025).","journal-title":"Nat. Commun."},{"key":"72693_CR27","doi-asserted-by":"publisher","DOI":"10.1038\/s41746-024-01187-5","volume":"7","author":"J Truslow","year":"2024","unstructured":"Truslow, J. et al. Understanding activity and physiology at scale: the apple heart and movement study. npj Digital Med. 7, 242 (2024).","journal-title":"npj Digital Med."},{"key":"72693_CR28","doi-asserted-by":"publisher","first-page":"553","DOI":"10.1113\/jphysiol.1955.sp005276","volume":"127","author":"JR Womersley","year":"1955","unstructured":"Womersley, J. R. Method for the calculation of velocity, rate of flow and viscous drag in arteries when the pressure gradient is known. J. Physiol. 127, 553\u2013563 (1955).","journal-title":"J. Physiol."},{"key":"72693_CR29","doi-asserted-by":"publisher","first-page":"467","DOI":"10.1146\/annurev-fluid-122109-160730","volume":"43","author":"FN van de Vosse","year":"2011","unstructured":"van de Vosse, F. N. & Stergiopulos, N. Pulse wave propagation in the arterial tree. Annu. Rev. Fluid Mech. 43, 467\u2013499 (2011).","journal-title":"Annu. Rev. Fluid Mech."},{"key":"72693_CR30","doi-asserted-by":"publisher","first-page":"794","DOI":"10.1007\/BF02584478","volume":"23","author":"B Duan","year":"1995","unstructured":"Duan, B. & Zamir, M. Pressure peaking in pulsatile flow through arterial tree structures. Ann. Biomed. Eng. 23, 794\u2013803 (1995).","journal-title":"Ann. Biomed. Eng."},{"key":"72693_CR31","doi-asserted-by":"crossref","unstructured":"Mukkamala, R. et al. The microsoft research aurora project: Important findings on cuffless blood pressure measurement. Hypertension 80, 534\u2013540 (2023).","DOI":"10.1161\/HYPERTENSIONAHA.122.20410"},{"key":"72693_CR32","doi-asserted-by":"publisher","first-page":"107663","DOI":"10.1016\/j.ress.2021.107663","volume":"213","author":"GM Melito","year":"2021","unstructured":"Melito, G. M. et al. Sensitivity analysis study on the effect of the fluid mechanics assumptions for the computation of electrical conductivity of flowing human blood. Reliab. Eng. I Syst. Saf. 213, 107663 (2021).","journal-title":"Reliab. Eng. I Syst. Saf."},{"key":"72693_CR33","doi-asserted-by":"publisher","unstructured":"Hasgall, P. et al. It\u2019is database for thermal and electromagnetic parameters of biological tissues version 4.1. (Accessed on 22 Feb 2022) https:\/\/doi.org\/10.13099\/VIP21000-04-1 (2022).","DOI":"10.13099\/VIP21000-04-1"},{"key":"72693_CR34","doi-asserted-by":"publisher","unstructured":"Ibrahim, B. et al. Continuous cuffless monitoring of arterial blood pressure via graphene bioimpedance tattoos (version 1.0.0). PhysioNet RRID:SCR_007345. https:\/\/doi.org\/10.13026\/ce62-pc98 (2022).","DOI":"10.13026\/ce62-pc98"}],"container-title":["Nature Communications"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.nature.com\/articles\/s41467-026-72693-1","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.nature.com\/articles\/s41467-026-72693-1.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.nature.com\/articles\/s41467-026-72693-1.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,7,17]],"date-time":"2026-07-17T11:03:09Z","timestamp":1784286189000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.nature.com\/articles\/s41467-026-72693-1"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,5,14]]},"references-count":34,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2026,12]]}},"alternative-id":["72693"],"URL":"https:\/\/doi.org\/10.1038\/s41467-026-72693-1","relation":{},"ISSN":["2041-1723"],"issn-type":[{"value":"2041-1723","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,5,14]]},"assertion":[{"value":"4 September 2025","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"21 April 2026","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"14 May 2026","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"B.S. is a co-founder of and holds equity in Haystack Diagnostics, Inc. He holds equity and serves as Scientific Advisor to B-Secur, Ltd., and Sobr Safe, Inc. He holds equity and serves as a Chief Scientific Officer of Hemodynamiq, Inc. He serves as a Chief Scientific Advisor to First Capital Ventures, LLC, and Chief Scientific Officer to Promptus, LLC. He holds equity and serves as Head of Biosensing and Product Development of NeuralPoint AI, Inc. The other authors have no conflicts of interest to declare.","order":1,"name":"Ethics","label":"Competing interests","group":{"name":"EthicsHeading","label":"Ethics"}}],"article-number":"6429"}}