{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,11,13]],"date-time":"2026-11-13T08:11:16Z","timestamp":1794557476407,"version":"4.9.1"},"reference-count":64,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2026,7,8]],"date-time":"2026-07-08T00:00:00Z","timestamp":1783468800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2026,8,17]],"date-time":"2026-08-17T00:00:00Z","timestamp":1786924800000},"content-version":"vor","delay-in-days":40,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"funder":[{"DOI":"10.13039\/501100000266","name":"RCUK | Engineering and Physical Sciences Research Council","doi-asserted-by":"publisher","award":["EP\/S022139\/1"],"award-info":[{"award-number":["EP\/S022139\/1"]}],"id":[{"id":"10.13039\/501100000266","id-type":"DOI","asserted-by":"publisher"}]},{"DOI":"10.13039\/501100003989","name":"Ikerbasque, Basque Foundation for Science","doi-asserted-by":"publisher","award":["RYC2024-048187-I"],"award-info":[{"award-number":["RYC2024-048187-I"]}],"id":[{"id":"10.13039\/501100003989","id-type":"DOI","asserted-by":"publisher"}]},{"DOI":"10.13039\/501100003086","name":"Eusko Jaurlaritza","doi-asserted-by":"publisher","award":["IT1766-22"],"award-info":[{"award-number":["IT1766-22"]}],"id":[{"id":"10.13039\/501100003086","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Nat Commun"],"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:p>Cutaneous electrophysiology is a fundamental non-invasive technique for assessing electrically active organs such as the brain, heart, and muscles. Standard approaches, however, are limited in spatial resolution, reducing sensitivity to certain pathological features. The development of body surface potential mapping using electrode arrays has helped overcome these limitations, enhancing the diagnostic power of cutaneous recordings, yet clinical adoption remains constrained by challenges in electrode performance, wiring complexity, wearability, data transmission, and interpretability. Here, we present a hybrid e-textile electrode array system that overcomes these barriers, enabling simultaneous mapping of electrical activity along the cortico-muscular axis. The system combines application-specific conducting polymer coatings to improve electrode performance, a flexible fabrication process for robust connectivity and wearability, and interpretable machine learning algorithms for data analysis. In controlled single-subject experiments, we demonstrate reliable muscle and brain recordings, enabling classification of grasped object shapes and somatosensory stimuli. Simultaneous multi-site recordings along the cortico-muscular axis provide spatial maps of reaction time distributions and allow prediction of muscle activation patterns from cortical activity. This platform establishes a framework for wearable, multi-modal electrophysiological mapping and non-invasive study of cortico-muscular dynamics, representing a step towards practical brain\u2013body interfaces with applications in neurorehabilitation, prosthetics, and human\u2013machine interaction.<\/jats:p>","DOI":"10.1038\/s41467-026-75134-1","type":"journal-article","created":{"date-parts":[[2026,7,8]],"date-time":"2026-07-08T16:55:03Z","timestamp":1783529703000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":3,"title":["Body surface potential mapping of the cortico-muscular axis using smart textile electrode arrays"],"prefix":"10.1038","volume":"17","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-8501-7068","authenticated-orcid":false,"given":"Ruben Ruiz-Mateos","family":"Serrano","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Charlie","family":"Brunt","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-8177-8831","authenticated-orcid":false,"given":"Xudong","family":"Tao","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-5883-9306","authenticated-orcid":false,"given":"Maciej","family":"Zajaczkowski","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Antonio","family":"Dominguez-Alfaro","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-3454-5992","authenticated-orcid":false,"given":"Matias L.","family":"Picchio","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-5495-9856","authenticated-orcid":false,"given":"Daniele","family":"Mantione","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Emmanuel M.","family":"Drakakis","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"David","family":"Mecerreyes","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-4582-8501","authenticated-orcid":false,"given":"George G.","family":"Malliaras","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2026,7,8]]},"reference":[{"key":"75134_CR1","doi-asserted-by":"publisher","first-page":"558070","DOI":"10.3389\/fphys.2020.558070","volume":"11","author":"R Rizzo","year":"2020","unstructured":"Rizzo, R., Zhang, X., Wang, J. W. J. L., Lombardi, F. & Ivanov, P. C. Network Physiology of Cortico\u2013Muscular Interactions. Front. Physiol. 11, 558070 (2020).","journal-title":"Front. Physiol."},{"key":"75134_CR2","unstructured":"Kandel, Eric. & Koester, John. Principles of Neural Science, 6th Edition. (2021)."},{"key":"75134_CR3","doi-asserted-by":"publisher","first-page":"1095260","DOI":"10.3389\/fphys.2023.1095260","volume":"14","author":"L Haggie","year":"2023","unstructured":"Haggie, L. et al. Linking cortex and contraction\u2014Integrating models along the corticomuscular pathway. Front. Physiol. 14, 1095260 (2023).","journal-title":"Front. Physiol."},{"key":"75134_CR4","doi-asserted-by":"publisher","first-page":"87","DOI":"10.1016\/S1567-4231(09)70155-8","volume":"1","author":"T Mima","year":"2003","unstructured":"Mima, T., Hallett, M. & Shibasaki, H. Chapter 7 Coherence, cortico-muscular. Handb. Clin. Neurophysiol. 1, 87\u201394 (2003).","journal-title":"Handb. Clin. Neurophysiol."},{"key":"75134_CR5","doi-asserted-by":"publisher","first-page":"442607","DOI":"10.3389\/fnhum.2019.00100","volume":"13","author":"J Liu","year":"2019","unstructured":"Liu, J., Sheng, Y. & Liu, H. Corticomuscular coherence and its applications: a review. Front. Hum. Neurosci. 13, 442607 (2019).","journal-title":"Front. Hum. Neurosci."},{"key":"75134_CR6","doi-asserted-by":"crossref","unstructured":"Vidaurre, C. et al. Canonical maximization of coherence: a novel tool for investigation of neuronal interactions between two datasets. Neuroimage 201, 1\u201311 (2019).","DOI":"10.1016\/j.neuroimage.2019.116009"},{"key":"75134_CR7","doi-asserted-by":"publisher","first-page":"610","DOI":"10.33588\/rn.5110.2010311","volume":"51","author":"E Lattari","year":"2010","unstructured":"Lattari, E. et al. Corticomuscular coherence behavior in fine motor control of force: a critical review. Rev. Neurol. 51, 610\u2013623 (2010).","journal-title":"Rev. Neurol."},{"key":"75134_CR8","doi-asserted-by":"publisher","first-page":"50","DOI":"10.1016\/j.nicl.2012.11.002","volume":"2","author":"HE Rossiter","year":"2013","unstructured":"Rossiter, H. E. et al. Changes in the location of cortico-muscular coherence following stroke. Neuroimage Clin. 2, 50\u201355 (2013).","journal-title":"Neuroimage Clin."},{"key":"75134_CR9","doi-asserted-by":"publisher","first-page":"1","DOI":"10.3389\/fnhum.2013.00855","volume":"7","author":"TW Boonstra","year":"2013","unstructured":"Boonstra, T. W. The potential of corticomuscular and intermuscular coherence for research on human motor control. Front. Hum. Neurosci. 7, 1\u20132 (2013).","journal-title":"Front. Hum. Neurosci."},{"key":"75134_CR10","doi-asserted-by":"publisher","first-page":"1182","DOI":"10.1016\/j.clinph.2013.11.006","volume":"125","author":"K von Carlowitz-Ghori","year":"2014","unstructured":"von Carlowitz-Ghori, K. et al. Corticomuscular coherence in acute and chronic stroke. Clin. Neurophysiol. 125, 1182\u20131191 (2014).","journal-title":"Clin. Neurophysiol."},{"key":"75134_CR11","doi-asserted-by":"publisher","first-page":"106","DOI":"10.1016\/j.clinph.2020.10.011","volume":"132","author":"A Coffey","year":"2021","unstructured":"Coffey, A. et al. Altered supraspinal motor networks in survivors of poliomyelitis: a cortico-muscular coherence study. Clin. Neurophysiol. 132, 106\u2013113 (2021).","journal-title":"Clin. Neurophysiol."},{"key":"75134_CR12","doi-asserted-by":"publisher","first-page":"106616","DOI":"10.1016\/j.nbd.2024.106616","volume":"200","author":"SAJEA Lagerweij","year":"2024","unstructured":"Lagerweij, S. A. J. E. A. et al. Connecting the dots \u2013 A systematic review on coherence analysis in dystonia. Neurobiol. Dis. 200, 106616 (2024).","journal-title":"Neurobiol. Dis."},{"key":"75134_CR13","doi-asserted-by":"publisher","first-page":"1354332","DOI":"10.3389\/fnhum.2024.1354332","volume":"18","author":"Z Gao","year":"2024","unstructured":"Gao, Z. et al. Influencing factors of corticomuscular coherence in stroke patients. Front. Hum. Neurosci. 18, 1354332 (2024).","journal-title":"Front. Hum. Neurosci."},{"key":"75134_CR14","doi-asserted-by":"publisher","first-page":"2843","DOI":"10.1152\/jn.00574.2015","volume":"114","author":"H Piitulainen","year":"2015","unstructured":"Piitulainen, H., Botter, A., Bourguignon, M., Jousm\u00e4ki, V. & Hari, R. Spatial variability in cortex-muscle coherence investigated with magnetoencephalography and high-density surface electromyography. J. Neurophysiol. 114, 2843\u20132853 (2015).","journal-title":"J. Neurophysiol."},{"key":"75134_CR15","doi-asserted-by":"publisher","first-page":"410","DOI":"10.3389\/fneur.2020.00410","volume":"11","author":"Z Guo","year":"2020","unstructured":"Guo, Z. et al. Altered Corticomuscular Coherence (CMCoh) pattern in the upper limb during finger movements after stroke. Front. Neurol. 11, 410 (2020).","journal-title":"Front. Neurol."},{"key":"75134_CR16","doi-asserted-by":"crossref","unstructured":"Zokaei, N. et al. Reduced cortico-muscular beta coupling in Parkinson\u2019s disease predicts motor impairment. Brain Commun. 3, 1\u20138 (2021).","DOI":"10.1093\/braincomms\/fcab179"},{"key":"75134_CR17","doi-asserted-by":"publisher","first-page":"81","DOI":"10.3390\/brainsci14010081","volume":"14","author":"W Ke","year":"2024","unstructured":"Ke, W. & Luo, Z. Analysis of cortico-muscular coupling and functional brain network under different standing balance paradigms. Brain Sci. 14, 81 (2024).","journal-title":"Brain Sci."},{"key":"75134_CR18","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1038\/s41598-025-06603-8","volume":"15","author":"G Anwar","year":"2025","unstructured":"Anwar, G. et al. Comparison of corticomuscular coherence under different balance paradigms in individuals with and without forward head posture. Sci. Rep. 15, 1\u201318 (2025).","journal-title":"Sci. Rep."},{"key":"75134_CR19","doi-asserted-by":"publisher","first-page":"1290","DOI":"10.1161\/01.CIR.76.6.1290","volume":"76","author":"LS Green","year":"1987","unstructured":"Green, L. S., Lux, R. L. & Haws, C. W. Detection and localization of coronary artery disease with body surface mapping in patients with normal electrocardiograms. Circulation 76, 1290\u20131297 (1987).","journal-title":"Circulation"},{"key":"75134_CR20","doi-asserted-by":"publisher","first-page":"779","DOI":"10.1016\/j.ajem.2008.06.010","volume":"27","author":"JP Ornato","year":"2009","unstructured":"Ornato, J. P. et al. Body surface mapping vs 12-lead electrocardiography to detect ST-elevation myocardial infarction. Am. J. Emerg. Med. 27, 779\u2013784 (2009).","journal-title":"Am. J. Emerg. Med."},{"key":"75134_CR21","doi-asserted-by":"publisher","first-page":"326","DOI":"10.1016\/j.jelectrocard.2010.02.002","volume":"43","author":"E Sz\u0171cs","year":"2010","unstructured":"Sz\u0171cs, E. et al. Diagnostic value of body surface potential mapping in assessment of the coronary artery lesion after angina pectoris and without repolarization changes on the electrocardiogram. J. Electrocardiol. 43, 326\u2013335 (2010).","journal-title":"J. Electrocardiol."},{"key":"75134_CR22","doi-asserted-by":"crossref","unstructured":"Merletti, R., Botter, A., Cescon, C., Minetto, M. A. & Vieira, T. M. M. Advances in surface EMG: recent progress in clinical research applications. Crit. Rev. Biomed. Eng. 38, 347\u201379 (2010).","DOI":"10.1615\/CritRevBiomedEng.v38.i4.20"},{"key":"75134_CR23","doi-asserted-by":"crossref","unstructured":"Merletti, R. & Farina, D. Surface Electromyography: Physiology, Engineering, and Applications. (John Wiley & Sons, 2016).","DOI":"10.1002\/9781119082934"},{"key":"75134_CR24","doi-asserted-by":"publisher","first-page":"5073","DOI":"10.1088\/0031-9155\/49\/22\/004","volume":"49","author":"D Yao","year":"2004","unstructured":"Yao, D., Yin, Z., Tang, X., Arendt-Nielsen, L. & Chen, A. C. N. High-resolution electroencephalogram (EEG) mapping: scalp charge layer. Phys. Med. Biol. 49, 5073 (2004).","journal-title":"Phys. Med. Biol."},{"key":"75134_CR25","doi-asserted-by":"publisher","DOI":"10.1038\/s41598-023-39700-7","volume":"13","author":"V Janiukstyte","year":"2023","unstructured":"Janiukstyte, V. et al. Normative brain mapping using scalp EEG and potential clinical application. Sci. Rep. 13, 13442 (2023).","journal-title":"Sci. Rep."},{"key":"75134_CR26","doi-asserted-by":"publisher","first-page":"270","DOI":"10.1109\/TBME.1978.326332","volume":"BME-25","author":"RL Lux","year":"1978","unstructured":"Lux, R. L., Smith, C. R., Wyatt, R. F. & Abildskov, J. A. Limited lead selection for estimation of body surface potential maps in electrocardiography. IEEE Trans. Biomed. Eng. BME-25, 270\u2013276 (1978).","journal-title":"IEEE Trans. Biomed. Eng."},{"key":"75134_CR27","doi-asserted-by":"publisher","first-page":"29","DOI":"10.1109\/51.62900","volume":"9","author":"S Usui","year":"1990","unstructured":"Usui, S. & Araki, H. Wigner distribution analysis of BSPM for optimal sampling. IEEE Eng. Med. Biol. Mag. 9, 29\u201332 (1990).","journal-title":"IEEE Eng. Med. Biol. Mag."},{"key":"75134_CR28","doi-asserted-by":"publisher","unstructured":"Dossel, O., Schneider, F. & Muller, M. Optimization of electrode positions for multichannel electrocardiography with respect to electrical imaging of the heart. in Proceedings of the 20th Annual International Conference of the IEEE Engineering in Medicine and Biology Society 71\u201374 (Institute of Electrical and Electronics Engineers (IEEE), 2002) https:\/\/doi.org\/10.1109\/IEMBS.1998.745825.","DOI":"10.1109\/IEMBS.1998.745825"},{"key":"75134_CR29","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1016\/j.jelekin.2004.06.008","volume":"15","author":"D Staudenmann","year":"2005","unstructured":"Staudenmann, D., Kingma, I., Stegeman, D. F. & van Die\u00ebn, J. H. Towards optimal multi-channel EMG electrode configurations in muscle force estimation: a high density EMG study. J. Electromyogr. Kinesiol. 15, 1\u201311 (2005).","journal-title":"J. Electromyogr. Kinesiol."},{"key":"75134_CR30","doi-asserted-by":"publisher","first-page":"586","DOI":"10.1016\/j.jelekin.2006.09.005","volume":"16","author":"G Drost","year":"2006","unstructured":"Drost, G., Stegeman, D. F., van Engelen, B. G. M. & Zwarts, M. J. Clinical applications of high-density surface EMG: a systematic review. J. Electromyogr. Kinesiol. 16, 586\u2013602 (2006).","journal-title":"J. Electromyogr. Kinesiol."},{"key":"75134_CR31","doi-asserted-by":"publisher","unstructured":"Andrews, A., Morin, E. & McLean, L. Optimal electrode configurations for finger movement classification using EMG. Proceedings of the 31st Annual International Conference of the IEEE Engineering in Medicine and Biology Society: Engineering the Future of Biomedicine, EMBC 2009 2987\u20132990 (2009) https:\/\/doi.org\/10.1109\/IEMBS.2009.5332520.","DOI":"10.1109\/IEMBS.2009.5332520"},{"key":"75134_CR32","doi-asserted-by":"publisher","first-page":"170","DOI":"10.1016\/j.bspc.2015.07.001","volume":"22","author":"B Afsharipour","year":"2015","unstructured":"Afsharipour, B., Ullah, K. & Merletti, R. Amplitude indicators and spatial aliasing in high density surface electromyography recordings. Biomed. Signal Process. Control 22, 170\u2013179 (2015).","journal-title":"Biomed. Signal Process. Control"},{"key":"75134_CR33","doi-asserted-by":"publisher","first-page":"298","DOI":"10.1016\/j.bspc.2018.12.001","volume":"49","author":"B Afsharipour","year":"2019","unstructured":"Afsharipour, B., Soedirdjo, S. & Merletti, R. Two-dimensional surface EMG: The effects of electrode size, interelectrode distance and image truncation. Biomed. Signal Process. Control 49, 298\u2013307 (2019).","journal-title":"Biomed. Signal Process. Control"},{"key":"75134_CR34","doi-asserted-by":"publisher","first-page":"128","DOI":"10.1016\/j.jelekin.2019.07.008","volume":"48","author":"M Besomi","year":"2019","unstructured":"Besomi, M. et al. Consensus for experimental design in electromyography (CEDE) project: electrode selection matrix. J. Electromyogr. Kinesiol. 48, 128\u2013144 (2019).","journal-title":"J. Electromyogr. Kinesiol."},{"key":"75134_CR35","doi-asserted-by":"publisher","unstructured":"Ruiz-Mateos Serrano, R. et al. High density body surface potential mapping with conducting polymer-eutectogel electrode arrays for ECG imaging. Adv. Sci. 2301176 https:\/\/doi.org\/10.1002\/ADVS.202301176.","DOI":"10.1002\/ADVS.202301176"},{"key":"75134_CR36","doi-asserted-by":"publisher","unstructured":"Ruiz-Mateos Serrano, R., Farina, D. & Malliaras, G. G. Body Surface Potential Mapping: A Perspective on High-Density Cutaneous Electrophysiology. Adv. Sci. 2411087 https:\/\/doi.org\/10.1002\/ADVS.202411087.","DOI":"10.1002\/ADVS.202411087"},{"key":"75134_CR37","unstructured":"Ruiz-Mateos Serrano, R. & Malliaras, G. G. Wearable devices and methods of manufacturing the same. (2024)."},{"key":"75134_CR38","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1038\/srep15003","volume":"5","author":"S Takamatsu","year":"2015","unstructured":"Takamatsu, S. et al. Direct patterning of organic conductors on knitted textiles for long-term electrocardiography. Sci. Rep. 5, 1\u20137 (2015).","journal-title":"Sci. Rep."},{"key":"75134_CR39","doi-asserted-by":"publisher","first-page":"224","DOI":"10.2174\/1877946811202030224","volume":"2","author":"M Ates","year":"2012","unstructured":"Ates, M., Karazehir, T. & Sarac, A. S. Conducting polymers and their applications. Curr. Phys. Chem. 2, 224\u2013240 (2012).","journal-title":"Curr. Phys. Chem."},{"key":"75134_CR40","doi-asserted-by":"publisher","first-page":"14944","DOI":"10.1039\/D4TC02908A","volume":"12","author":"C Slaughter","year":"2024","unstructured":"Slaughter, C. et al. Electrogelation of PEDOT:PSS and its copolymer for bioelectronics. J. Mater. Chem. C. Mater. 12, 14944\u201314954 (2024).","journal-title":"J. Mater. Chem. C. Mater."},{"key":"75134_CR41","doi-asserted-by":"crossref","unstructured":"Vidhya, C. M., Maithani, Y. & Singh, J. P. Recent Advances and Challenges in Textile Electrodes for Wearable Biopotential Signal Monitoring: A Comprehensive Review. Biosensors 2023. 13, (2023).","DOI":"10.3390\/bios13070679"},{"key":"75134_CR42","doi-asserted-by":"publisher","DOI":"10.1038\/s41598-023-30207-9","volume":"13","author":"A Chakraborty","year":"2023","unstructured":"Chakraborty, A. et al. Conductive organic electrodes for flexible electronic devices. Sci. Rep. 13, 4125 (2023).","journal-title":"Sci. Rep."},{"key":"75134_CR43","doi-asserted-by":"publisher","unstructured":"Picchio, M. L. et al. Mixed Ionic and Electronic Conducting Eutectogels for 3D-Printable Wearable Sensors and Bioelectrodes. Adv. Mater. Technol. (2022) https:\/\/doi.org\/10.1002\/ADMT.202101680.","DOI":"10.1002\/ADMT.202101680"},{"key":"75134_CR44","doi-asserted-by":"crossref","unstructured":"Volkov, A. V. et al. Understanding the Capacitance of PEDOT:PSS. Adv. Funct. Mater. 27, 1\u201310 (2017).","DOI":"10.1002\/adfm.201770059"},{"key":"75134_CR45","doi-asserted-by":"publisher","first-page":"217","DOI":"10.1039\/C7LC00914C","volume":"18","author":"J Heikenfeld","year":"2018","unstructured":"Heikenfeld, J. et al. Wearable sensors: modalities, challenges, and prospects. Lab Chip 18, 217\u2013248 (2018).","journal-title":"Lab Chip"},{"key":"75134_CR46","doi-asserted-by":"publisher","first-page":"2202661","DOI":"10.1002\/adhm.202202661","volume":"12","author":"S Roubert Martinez","year":"2023","unstructured":"Roubert Martinez, S., Le Floch, P., Liu, J. & Howe, R. D. Pure conducting polymer hydrogels increase signal-to-noise of cutaneous electrodes by lowering skin interface impedance. Adv. Healthc. Mater. 12, 2202661 (2023).","journal-title":"Adv. Healthc. Mater."},{"key":"75134_CR47","doi-asserted-by":"crossref","unstructured":"Dominguez-Alfaro, A. et al. Light-Based 3D multi-material printing of micro-structured bio-Shaped, conducting and dry adhesive electrodes for bioelectronics. Adv. Sci. 11, 1\u201313 (2024).","DOI":"10.1002\/advs.202306424"},{"key":"75134_CR48","doi-asserted-by":"publisher","first-page":"11060","DOI":"10.1021\/cr300162p","volume":"114","author":"EL Smith","year":"2014","unstructured":"Smith, E. L., Abbott, A. P. & Ryder, K. S. Deep Eutectic Solvents (DESs) and their applications. Chem. Rev. 114, 11060\u201311082 (2014).","journal-title":"Chem. Rev."},{"key":"75134_CR49","doi-asserted-by":"publisher","first-page":"2200103","DOI":"10.1002\/mabi.202200103","volume":"22","author":"RL Keate","year":"2022","unstructured":"Keate, R. L. et al. 3D-printed electroactive hydrogel architectures with sub\u2212100 \u00b5m resolution promote myoblast viability. Macromol. Biosci. 22, 2200103 (2022).","journal-title":"Macromol. Biosci."},{"key":"75134_CR50","doi-asserted-by":"publisher","first-page":"1838","DOI":"10.1039\/C5TA10096H","volume":"4","author":"FN Ajjan","year":"2016","unstructured":"Ajjan, F. N. et al. High performance PEDOT\/lignin biopolymer composites for electrochemical supercapacitors. J. Mater. Chem. A Mater. 4, 1838\u20131847 (2016).","journal-title":"J. Mater. Chem. A Mater."},{"key":"75134_CR51","doi-asserted-by":"publisher","first-page":"122624","DOI":"10.1016\/j.biomaterials.2024.122624","volume":"310","author":"R Ruiz-Mateos Serrano","year":"2024","unstructured":"Ruiz-Mateos Serrano, R. et al. 3D printed PEDOT:PSS-based conducting and patternable eutectogel electrodes for machine learning on textiles. Biomaterials 310, 122624 (2024).","journal-title":"Biomaterials"},{"key":"75134_CR52","doi-asserted-by":"publisher","first-page":"8942","DOI":"10.1039\/C5TC01888A","volume":"3","author":"M Isik","year":"2015","unstructured":"Isik, M. et al. Cholinium-based ion gels as solid electrolytes for long-term cutaneous electrophysiology. J. Mater. Chem. C. Mater. 3, 8942\u20138948 (2015).","journal-title":"J. Mater. Chem. C. Mater."},{"key":"75134_CR53","doi-asserted-by":"publisher","DOI":"10.1002\/ange.202301489","volume":"135","author":"M Criado-Gonzalez","year":"2023","unstructured":"Criado-Gonzalez, M. et al. Mixed conductive, injectable, and fluorescent supramolecular eutectogel composites. Angew. Chem. 135, e202301489 (2023).","journal-title":"Angew. Chem."},{"key":"75134_CR54","doi-asserted-by":"publisher","first-page":"473","DOI":"10.1021\/acsmacrolett.7b00104","volume":"6","author":"I Del Agua","year":"2017","unstructured":"Del Agua, I. et al. Conducting polymer iongels based on PEDOT and Guar Gum. ACS Macro Lett. 6, 473\u2013478 (2017).","journal-title":"ACS Macro Lett."},{"key":"75134_CR55","doi-asserted-by":"publisher","first-page":"7424","DOI":"10.1021\/acsomega.8b00458","volume":"3","author":"I Del Agua","year":"2018","unstructured":"Del Agua, I. et al. Conducting polymer scaffolds based on Poly(3,4-ethylenedioxythiophene) and Xanthan gum for live-cell monitoring. ACS Omega 3, 7424\u20137431 (2018).","journal-title":"ACS Omega"},{"key":"75134_CR56","doi-asserted-by":"crossref","unstructured":"Yuen, A. Y. et al. Biodegradable polycarbonate iongels for electrophysiology measurements. Polymers 10, 1\u201312 (2018).","DOI":"10.3390\/polym10090989"},{"key":"75134_CR57","doi-asserted-by":"publisher","first-page":"2100374","DOI":"10.1002\/adhm.202100374","volume":"10","author":"S Velasco-Bosom","year":"2021","unstructured":"Velasco-Bosom, S. et al. Conducting polymer-ionic liquid electrode arrays for high-density surface electromyography. Adv. Healthc. Mater. 10, 2100374 (2021).","journal-title":"Adv. Healthc. Mater."},{"key":"75134_CR58","doi-asserted-by":"publisher","first-page":"15186","DOI":"10.1039\/D2TC03248A","volume":"10","author":"N Casado","year":"2022","unstructured":"Casado, N. et al. Injectable PEDOT:PSS\/cholinium ionic liquid mixed conducting materials for electrocardiogram recordings. J. Mater. Chem. C. Mater. 10, 15186\u201315193 (2022).","journal-title":"J. Mater. Chem. C. Mater."},{"key":"75134_CR59","doi-asserted-by":"publisher","first-page":"2516","DOI":"10.1039\/D3MH00310H","volume":"10","author":"A Aguzin","year":"2023","unstructured":"Aguzin, A. et al. Direct ink writing of PEDOT eutectogels as substrate-free dry electrodes for electromyography. Mater. Horiz. 10, 2516\u20132524 (2023).","journal-title":"Mater. Horiz."},{"key":"75134_CR60","doi-asserted-by":"publisher","first-page":"630","DOI":"10.3390\/bios12080630","volume":"12","author":"H Ullah","year":"2022","unstructured":"Ullah, H. et al. Recent advances in stretchable and wearable capacitive electrophysiological sensors for long-term health monitoring. Biosens. (Basel) 12, 630 (2022).","journal-title":"Biosens. (Basel)"},{"key":"75134_CR61","doi-asserted-by":"publisher","first-page":"e09934","DOI":"10.1002\/advs.202509934","volume":"13","author":"Z Liao","year":"2025","unstructured":"Liao, Z., Golparvar, A., Bathaei, M. J., Cardoso, F. A. & Boutry, C. M. Wearable and implantable devices for continuous monitoring of muscle physiological activity: a review. Adv. Sci. 13, e09934 (2025).","journal-title":"Adv. Sci."},{"key":"75134_CR62","first-page":"202510","volume":"3","author":"J Ji","year":"2025","unstructured":"Ji, J. et al. Progress in the flexible and stretchable epidermal electrodes for wearable ECG monitoring. BME Horiz. 3, 202510\u2013202510 (2025).","journal-title":"BME Horiz."},{"key":"75134_CR63","doi-asserted-by":"publisher","first-page":"879","DOI":"10.1016\/j.jelekin.2008.09.002","volume":"18","author":"R Merletti","year":"2008","unstructured":"Merletti, R., Holobar, A. & Farina, D. Analysis of motor units with high-density surface electromyography. J. Electromyogr. Kinesiol. 18, 879\u2013890 (2008).","journal-title":"J. Electromyogr. Kinesiol."},{"key":"75134_CR64","unstructured":"Buettner, R., Frick, J. & Rieg, T. High-performance detection of epilepsy in seizure-free EEG recordings: A novel machine learning approach using very specific epileptic EEG sub-bands. International Conference on Interaction Sciences (2019)."}],"container-title":["Nature Communications"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.nature.com\/articles\/s41467-026-75134-1","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.nature.com\/articles\/s41467-026-75134-1.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.nature.com\/articles\/s41467-026-75134-1.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,8,17]],"date-time":"2026-08-17T11:02:41Z","timestamp":1786964561000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.nature.com\/articles\/s41467-026-75134-1"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,7,8]]},"references-count":64,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2026,12]]}},"alternative-id":["75134"],"URL":"https:\/\/doi.org\/10.1038\/s41467-026-75134-1","relation":{},"ISSN":["2041-1723"],"issn-type":[{"value":"2041-1723","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,7,8]]},"assertion":[{"value":"14 October 2025","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"17 June 2026","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"8 July 2026","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"The authors declare the following competing interests: R.R.S. and G.G.M. are named inventors on a patent application covering aspects of the smart textile electrode array technology described in this manuscript. The patent is filed and pending and is not currently licensed or associated with commercial revenue. All other authors declare no competing interests.","order":1,"name":"Ethics","label":"Competing interests","group":{"name":"EthicsHeading","label":"Ethics"}}],"article-number":"8441"}}