{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,10]],"date-time":"2026-09-10T00:11:33Z","timestamp":1788999093859,"version":"build-2803163510"},"reference-count":59,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2026,8,13]],"date-time":"2026-08-13T00:00:00Z","timestamp":1786579200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2026,9,10]],"date-time":"2026-09-10T00:00:00Z","timestamp":1788998400000},"content-version":"vor","delay-in-days":28,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"funder":[{"DOI":"10.13039\/501100003246","name":"Nederlandse Organisatie voor Wetenschappelijk Onderzoek","doi-asserted-by":"publisher","award":["Spinoza Award SPI.2017.028"],"award-info":[{"award-number":["Spinoza Award SPI.2017.028"]}],"id":[{"id":"10.13039\/501100003246","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Nat Commun"],"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:p>Native mass spectrometry has become a key method for studying macromolecular assemblies, providing insights into structures, stoichiometries, and binding interactions. A key aspect for the transmission of electrospray-generated bioparticles into the mass analyzer is the use of gas for collisional cooling and ion desolvation. However, in Orbitrap-based mass spectrometry, the elevated pressure may negatively affect ions, as collisions with background gas can destabilize ion trajectories, potentially leading to incorrect mass determination. These effects are amplified when the pressure in the collision cell is high, as required for large biological assemblies, and when ions are measured for (ultra)long acquisition times in the Orbitrap, as required for high-resolution mass spectrometry. To address these issues, we modified a standard Q Exactive\u2122 UHMR by installing a pulsed valve to control gas flow and limit gas leakage into the Orbitrap. This way, ion transmission and desolvation are maintained while the ultrahigh vacuum in the mass analyzer is enhanced during acquisition. We show that this improves ion detection of various assemblies, including adeno-associated viruses, IgM, and plasmid DNA, with superior mass accuracy and resolving power. The pulsed valve implementation will benefit nearly all mass measurements, setting the stage for next-generation Orbitrap-based, single-ion mass spectrometry.<\/jats:p>","DOI":"10.1038\/s41467-026-76691-1","type":"journal-article","created":{"date-parts":[[2026,8,13]],"date-time":"2026-08-13T01:13:12Z","timestamp":1786583592000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":0,"title":["Modulating pressure in the Orbitrap improves sensitivity and mass resolution in charge detection mass spectrometry"],"prefix":"10.1038","volume":"17","author":[{"given":"Eduard H.T.M.","family":"Ebberink","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0009-0001-2351-2581","authenticated-orcid":false,"given":"Elena","family":"Giaretta","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Arjan","family":"Barendregt","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-7753-8170","authenticated-orcid":false,"given":"Jan","family":"Fiala","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-0104-0293","authenticated-orcid":false,"given":"Victor C.","family":"Yin","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Tobias P.","family":"W\u00f6rner","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Kyle L.","family":"Fort","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-7046-6709","authenticated-orcid":false,"given":"Alexander A.","family":"Makarov","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-2405-4404","authenticated-orcid":false,"given":"Albert. J. R.","family":"Heck","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2026,8,13]]},"reference":[{"key":"76691_CR1","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1002\/(SICI)1098-2787(1997)16:1<1::AID-MAS1>3.0.CO;2-L","volume":"16","author":"JA Loo","year":"1997","unstructured":"Loo, J. A. Studying noncovalent protein complexes by electrospray ionization mass spectrometry. Mass Spectrom. Rev. 16, 1\u201323 (1997).","journal-title":"Mass Spectrom. Rev."},{"key":"76691_CR2","doi-asserted-by":"publisher","first-page":"157","DOI":"10.1146\/annurev-biophys-092721-085421","volume":"51","author":"KR Karch","year":"2022","unstructured":"Karch, K. R., Snyder, D. T., Harvey, S. R. & Wysocki, V. H. Native mass spectrometry: recent progress and remaining challenges. Annu Rev. Biophys. 51, 157\u2013179 (2022).","journal-title":"Annu Rev. Biophys."},{"key":"76691_CR3","doi-asserted-by":"publisher","first-page":"519","DOI":"10.1016\/j.cbpa.2004.08.006","volume":"8","author":"RH Heuvel","year":"2004","unstructured":"Heuvel, R. H. & Heck, A. J. Native protein mass spectrometry: from intact oligomers to functional machineries. Curr. Opin. Chem. Biol. 8, 519\u2013526 (2004).","journal-title":"Curr. Opin. Chem. Biol."},{"key":"76691_CR4","doi-asserted-by":"publisher","first-page":"453","DOI":"10.1146\/annurev-physchem-040214-121732","volume":"66","author":"S Mehmood","year":"2015","unstructured":"Mehmood, S., Allison, T. M. & Robinson, C. V. Mass spectrometry of protein complexes: from origins to applications. Annu Rev. Phys. Chem. 66, 453\u2013474 (2015).","journal-title":"Annu Rev. Phys. Chem."},{"key":"76691_CR5","doi-asserted-by":"publisher","first-page":"801","DOI":"10.1098\/rsif.2011.0823","volume":"9","author":"GR Hilton","year":"2012","unstructured":"Hilton, G. R. & Benesch, J. L. Two decades of studying non-covalent biomolecular assemblies by means of electrospray ionization mass spectrometry. J. R. Soc. Interface 9, 801\u2013816 (2012).","journal-title":"J. R. Soc. Interface"},{"key":"76691_CR6","doi-asserted-by":"publisher","first-page":"7269","DOI":"10.1021\/acs.chemrev.1c00212","volume":"122","author":"S Tamara","year":"2022","unstructured":"Tamara, S., den Boer, M. A. & Heck, A. J. R. High-resolution native mass spectrometry. Chem. Rev. 122, 7269\u20137326 (2022).","journal-title":"Chem. Rev."},{"key":"76691_CR7","doi-asserted-by":"publisher","first-page":"632","DOI":"10.1021\/jasms.4c00348","volume":"36","author":"IDG Campuzano","year":"2025","unstructured":"Campuzano, I. D. G. & Loo, J. A. Evolution of mass spectrometers for high m\/z biological ion formation, transmission, analysis and detection: a personal perspective. J. Am. Soc. Mass Spectrom. 36, 632\u2013652 (2025).","journal-title":"J. Am. Soc. Mass Spectrom."},{"key":"76691_CR8","doi-asserted-by":"publisher","first-page":"569","DOI":"10.1016\/S1044-0305(98)00027-0","volume":"9","author":"AN Krutchinsky","year":"1998","unstructured":"Krutchinsky, A. N., Chernushevich, I. V., Spicer, V. L., Ens, W. & Standing, K. G. Collisional damping interface for an electrospray ionization time-of-flight mass spectrometer. J. Am. Soc. Mass Spectr. 9, 569\u2013579 (1998).","journal-title":"J. Am. Soc. Mass Spectr."},{"key":"76691_CR9","doi-asserted-by":"publisher","first-page":"1754","DOI":"10.1021\/ac035406j","volume":"76","author":"IV Chernushevich","year":"2004","unstructured":"Chernushevich, I. V. & Thomson, B. A. Collisional cooling of large ions in electrospray mass spectrometry. Anal. Chem. 76, 1754\u20131760 (2004).","journal-title":"Anal. Chem."},{"key":"76691_CR10","doi-asserted-by":"publisher","first-page":"6040","DOI":"10.1021\/ac010451h","volume":"73","author":"A Schmidt","year":"2001","unstructured":"Schmidt, A., Bahr, U. & Karas, M. Influence of pressure in the first pumping stage on analyte desolvation and fragmentation in nano-ESI MS. Anal. Chem. 73, 6040\u20136046 (2001).","journal-title":"Anal. Chem."},{"key":"76691_CR11","doi-asserted-by":"publisher","first-page":"12992","DOI":"10.1002\/anie.201206745","volume":"51","author":"S Rosati","year":"2012","unstructured":"Rosati, S. et al. Exploring an Orbitrap analyzer for the characterization of intact antibodies by native mass spectrometry. Angew. Chem. Int Ed. Engl. 51, 12992\u201312996 (2012).","journal-title":"Angew. Chem. Int Ed. Engl."},{"key":"76691_CR12","doi-asserted-by":"publisher","first-page":"709","DOI":"10.1038\/nmeth1060","volume":"4","author":"JV Olsen","year":"2007","unstructured":"Olsen, J. V. et al. Higher-energy C-trap dissociation for peptide modification analysis. Nat. Methods 4, 709\u2013712 (2007).","journal-title":"Nat. Methods"},{"key":"76691_CR13","doi-asserted-by":"publisher","first-page":"1084","DOI":"10.1038\/nmeth.2208","volume":"9","author":"RJ Rose","year":"2012","unstructured":"Rose, R. J., Damoc, E., Denisov, E., Makarov, A. & Heck, A. J. High-sensitivity Orbitrap mass analysis of intact macromolecular assemblies. Nat. Methods 9, 1084\u20131086 (2012).","journal-title":"Nat. Methods"},{"key":"76691_CR14","doi-asserted-by":"publisher","first-page":"100","DOI":"10.1039\/C7AN01629H","volume":"143","author":"KL Fort","year":"2017","unstructured":"Fort, K. L. et al. Expanding the structural analysis capabilities on an Orbitrap-based mass spectrometer for large macromolecular complexes. Analyst 143, 100\u2013105 (2017).","journal-title":"Analyst"},{"key":"76691_CR15","doi-asserted-by":"publisher","first-page":"283","DOI":"10.1038\/nmeth.4147","volume":"14","author":"M van de Waterbeemd","year":"2017","unstructured":"van de Waterbeemd, M. et al. High-fidelity mass analysis unveils heterogeneity in intact ribosomal particles. Nat. Methods 14, 283\u2013286 (2017).","journal-title":"Nat. Methods"},{"key":"76691_CR16","doi-asserted-by":"publisher","first-page":"5438","DOI":"10.1021\/acs.jproteome.4c00568","volume":"23","author":"JN Walker","year":"2024","unstructured":"Walker, J. N., Gautam, A. K. S., Matouschek, A. & Brodbelt, J. S. Structural Analysis of the 20S Proteasome Using Native Mass Spectrometry and Ultraviolet Photodissociation. J. Proteome Res 23, 5438\u20135448 (2024).","journal-title":"J. Proteome Res"},{"key":"76691_CR17","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1038\/s41596-024-01037-4","volume":"20","author":"D Wu","year":"2025","unstructured":"Wu, D. et al. Native MS-guided lipidomics to define endogenous lipid microenvironments of eukaryotic receptors and transporters. Nat. Protoc. 20, 1\u201325 (2025).","journal-title":"Nat. Protoc."},{"key":"76691_CR18","doi-asserted-by":"publisher","first-page":"1567","DOI":"10.1021\/jasms.4c00151","volume":"35","author":"VC Cotham","year":"2024","unstructured":"Cotham, V. C., Wang, S. & Li, N. An online native mass spectrometry approach for fast, sensitive, and quantitative assessment of adeno-associated virus capsid content ratios. J. Am. Soc. Mass Spectrom. 35, 1567\u20131575 (2024).","journal-title":"J. Am. Soc. Mass Spectrom."},{"key":"76691_CR19","doi-asserted-by":"publisher","first-page":"1548","DOI":"10.1021\/acscentsci.4c00462","volume":"10","author":"KIP Le Huray","year":"2024","unstructured":"Le Huray, K. I. P. et al. To 200,000 m\/z and beyond: native electron capture charge reduction mass spectrometry deconvolves heterogeneous signals in large biopharmaceutical analytes. ACS Cent. Sci. 10, 1548\u20131561 (2024).","journal-title":"ACS Cent. Sci."},{"key":"76691_CR20","doi-asserted-by":"publisher","first-page":"7295","DOI":"10.1021\/ja502616y","volume":"136","author":"J Snijder","year":"2014","unstructured":"Snijder, J. et al. Defining the stoichiometry and cargo load of viral and bacterial nanoparticles by Orbitrap mass spectrometry. J. Am. Chem. Soc. 136, 7295\u20137299 (2014).","journal-title":"J. Am. Chem. Soc."},{"key":"76691_CR21","doi-asserted-by":"publisher","first-page":"5749","DOI":"10.1021\/jacs.3c08139","volume":"146","author":"MF Jarrold","year":"2024","unstructured":"Jarrold, M. F. Single-Ion mass spectrometry for heterogeneous and high molecular weight samples. J. Am. Chem. Soc. 146, 5749\u20135758 (2024).","journal-title":"J. Am. Chem. Soc."},{"key":"76691_CR22","doi-asserted-by":"publisher","first-page":"1458","DOI":"10.1021\/acs.accounts.3c00079","volume":"56","author":"E Desligniere","year":"2023","unstructured":"Desligniere, E., Rolland, A., Ebberink, E. H. T. M., Yin, V. C. & Heck, A. J. R. Orbitrap-Based mass and charge analysis of single molecules. Acc. Chem. Res. 56, 1458\u20131468 (2023).","journal-title":"Acc. Chem. Res."},{"key":"76691_CR23","doi-asserted-by":"publisher","first-page":"2200","DOI":"10.1007\/s13361-019-02309-0","volume":"30","author":"JO Kafader","year":"2019","unstructured":"Kafader, J. O. et al. STORI plots enable accurate tracking of individual ion signals. J. Am. Soc. Mass Spectrom. 30, 2200\u20132203 (2019).","journal-title":"J. Am. Soc. Mass Spectrom."},{"key":"76691_CR24","doi-asserted-by":"publisher","DOI":"10.1016\/j.jconrel.2025.113856","volume":"384","author":"ZM Miller","year":"2025","unstructured":"Miller, Z. M. et al. Single particle charge detection mass spectrometry enables molecular characterization of lipid nanoparticles and mRNA packaging. J. Control Release 384, 113856 (2025).","journal-title":"J. Control Release"},{"key":"76691_CR25","doi-asserted-by":"publisher","first-page":"87","DOI":"10.1016\/j.omtm.2021.08.002","volume":"23","author":"LF Barnes","year":"2021","unstructured":"Barnes, L. F., Draper, B. E., Chen, Y. T., Powers, T. W. & Jarrold, M. F. Quantitative analysis of genome packaging in recombinant AAV vectors by charge detection mass spectrometry. Mol. Ther. Methods Clin. Dev. 23, 87\u201397 (2021).","journal-title":"Mol. Ther. Methods Clin. Dev."},{"key":"76691_CR26","doi-asserted-by":"publisher","first-page":"8965","DOI":"10.1021\/acs.analchem.3c01027","volume":"95","author":"LM Miller","year":"2023","unstructured":"Miller, L. M., Draper, B. E., Barnes, L. F., Ofoegbu, P. C. & Jarrold, M. F. Analysis of megadalton-Sized DNA by charge detection mass spectrometry: entropic trapping and shearing in nanoelectrospray. Anal. Chem. 95, 8965\u20138973 (2023).","journal-title":"Anal. Chem."},{"key":"76691_CR27","doi-asserted-by":"publisher","first-page":"40","DOI":"10.1016\/j.omtm.2021.11.013","volume":"24","author":"TP Worner","year":"2022","unstructured":"Worner, T. P., Snijder, J., Friese, O., Powers, T. & Heck, A. J. R. Assessment of genome packaging in AAVs using Orbitrap-based charge-detection mass spectrometry. Mol. Ther. Methods Clin. Dev. 24, 40\u201347 (2022).","journal-title":"Mol. Ther. Methods Clin. Dev."},{"key":"76691_CR28","doi-asserted-by":"publisher","first-page":"1320","DOI":"10.1021\/jasms.4c00094","volume":"35","author":"V Yin","year":"2024","unstructured":"Yin, V. et al. Not all arms of IgM are equal: following hinge-directed cleavage by online native SEC-Orbitrap-Based CDMS. J. Am. Soc. Mass Spectrom. 35, 1320\u20131329 (2024).","journal-title":"J. Am. Soc. Mass Spectrom."},{"key":"76691_CR29","doi-asserted-by":"publisher","first-page":"391","DOI":"10.1038\/s41592-020-0764-5","volume":"17","author":"JO Kafader","year":"2020","unstructured":"Kafader, J. O. et al. Multiplexed mass spectrometry of individual ions improves measurement of proteoforms and their complexes. Nat. Methods 17, 391\u2013394 (2020).","journal-title":"Nat. Methods"},{"key":"76691_CR30","doi-asserted-by":"publisher","first-page":"15118","DOI":"10.1021\/acs.analchem.3c03325","volume":"95","author":"L Strasser","year":"2023","unstructured":"Strasser, L., F\u00fcssl, F., Morgan, T. E., Carillo, S. & Bones, J. Exploring charge-detection mass spectrometry on chromatographic time scales. Anal. Chem. 95, 15118\u201315124 (2023).","journal-title":"Anal. Chem."},{"key":"76691_CR31","doi-asserted-by":"publisher","first-page":"16543","DOI":"10.1021\/acs.analchem.2c03495","volume":"94","author":"JP McGee","year":"2022","unstructured":"McGee, J. P. et al. Automated control of injection times for unattended acquisition of multiplexed individual ion mass spectra. Anal. Chem. 94, 16543\u201316548 (2022).","journal-title":"Anal. Chem."},{"key":"76691_CR32","doi-asserted-by":"publisher","first-page":"16743","DOI":"10.1021\/acs.analchem.4c03248","volume":"96","author":"JD Sanders","year":"2024","unstructured":"Sanders, J. D., Owen, O. N., Tran, B. H., Mosqueira, J. L. & Marty, M. T. Coupling online size exclusion chromatography with charge detection-mass spectrometry using Hadamard transform multiplexing. Anal. Chem. 96, 16743\u201316749 (2024).","journal-title":"Anal. Chem."},{"key":"76691_CR33","doi-asserted-by":"publisher","first-page":"17037","DOI":"10.1021\/acs.analchem.4c05229","volume":"96","author":"R Nakatsuka","year":"2024","unstructured":"Nakatsuka, R. et al. Multimass analysis of adeno-associated virus vectors by orbitrap-based charge detection mass spectrometry. Anal. Chem. 96, 17037\u201317046 (2024).","journal-title":"Anal. Chem."},{"key":"76691_CR34","doi-asserted-by":"publisher","first-page":"2811","DOI":"10.1021\/jasms.3c00321","volume":"34","author":"JP Ryan","year":"2023","unstructured":"Ryan, J. P. et al. Characterizing adeno-associated virus capsids with both denaturing and intact analysis methods. J. Am. Soc. Mass Spectr. 34, 2811\u20132821 (2023).","journal-title":"J. Am. Soc. Mass Spectr."},{"key":"76691_CR35","doi-asserted-by":"publisher","first-page":"1659","DOI":"10.1021\/jasms.5c00074","volume":"36","author":"K Pathak","year":"2025","unstructured":"Pathak, K. et al. Characterizing the content and structure of AAV capsids by size exclusion chromatography and Orbitrap-based charge detection-mass spectrometry. J. Am. Soc. Mass Spectr. 36, 1659\u20131668 (2025).","journal-title":"J. Am. Soc. Mass Spectr."},{"key":"76691_CR36","doi-asserted-by":"publisher","first-page":"1241","DOI":"10.1021\/jasms.4c00503","volume":"36","author":"JS Jordan","year":"2025","unstructured":"Jordan, J. S. et al. Characterizing Monoclonal antibody aggregation using charge detection mass spectrometry and industry standard methods. J. Am. Soc. Mass Spectr. 36, 1241\u20131253 (2025).","journal-title":"J. Am. Soc. Mass Spectr."},{"key":"76691_CR37","doi-asserted-by":"publisher","first-page":"395","DOI":"10.1038\/s41592-020-0770-7","volume":"17","author":"TP Worner","year":"2020","unstructured":"Worner, T. P. et al. Resolving heterogeneous macromolecular assemblies by Orbitrap-based single-particle charge detection mass spectrometry. Nat. Methods 17, 395\u2013398 (2020).","journal-title":"Nat. Methods"},{"key":"76691_CR38","doi-asserted-by":"publisher","first-page":"619","DOI":"10.1038\/s41592-024-02207-8","volume":"21","author":"E Desligniere","year":"2024","unstructured":"Desligniere, E. et al. Ultralong transients enhance sensitivity and resolution in Orbitrap-based single-ion mass spectrometry. Nat. Methods 21, 619\u2013622 (2024).","journal-title":"Nat. Methods"},{"key":"76691_CR39","doi-asserted-by":"publisher","first-page":"1605","DOI":"10.1039\/D5AN00019J","volume":"150","author":"E Hanozin","year":"2025","unstructured":"Hanozin, E., Harper, C. C., Jordan, J. S., Miller, Z. M. & Williams, E. R. High performance charge detection mass spectrometry without ultra-high vacuum. Analyst 150, 1605\u20131616 (2025).","journal-title":"Analyst"},{"key":"76691_CR40","doi-asserted-by":"publisher","first-page":"515","DOI":"10.1038\/s41557-022-00897-1","volume":"14","author":"TP Worner","year":"2022","unstructured":"Worner, T. P. et al. Frequency chasing of individual megadalton ions in an Orbitrap analyser improves precision of analysis in single-molecule mass spectrometry. Nat. Chem. 14, 515\u2013522 (2022).","journal-title":"Nat. Chem."},{"key":"76691_CR41","doi-asserted-by":"publisher","first-page":"10925","DOI":"10.1021\/jacs.4c13393","volume":"147","author":"E Ebberink","year":"2025","unstructured":"Ebberink, E. et al. Prolonged trapping of adeno-associated virus capsids reveals that genome packaging affects single-ion mass spectrometry measurements. J. Am. Chem. Soc. 147, 10925\u201310934 (2025).","journal-title":"J. Am. Chem. Soc."},{"key":"76691_CR42","doi-asserted-by":"publisher","first-page":"5896","DOI":"10.1021\/acs.analchem.8b00724","volume":"90","author":"JD Sanders","year":"2018","unstructured":"Sanders, J. D. et al. Determination of Collision Cross-Sections of Protein Ions in an Orbitrap Mass Analyzer. Anal. Chem. 90, 5896\u20135902 (2018).","journal-title":"Anal. Chem."},{"key":"76691_CR43","doi-asserted-by":"publisher","first-page":"491","DOI":"10.1016\/j.omtm.2022.11.003","volume":"27","author":"E Ebberink","year":"2022","unstructured":"Ebberink, E., Ruisinger, A., Nuebel, M., Thomann, M. & Heck, A. J. R. Assessing production variability in empty and filled adeno-associated viruses by single molecule mass analyses. Mol. Ther. Methods Clin. Dev. 27, 491\u2013501 (2022).","journal-title":"Mol. Ther. Methods Clin. Dev."},{"key":"76691_CR44","doi-asserted-by":"publisher","unstructured":"Young, L. M., Draper, B. E., Jarrold, M. F., Froelich, C. A. & Motevalian, S. P. End-to-end characterization of AAV manufacturing process using charge detection mass spectrometry. Mol. Ther. Meth. Clin. D 33 https:\/\/doi.org\/10.1016\/j.omtm.2025.101607 (2025).","DOI":"10.1016\/j.omtm.2025.101607"},{"key":"76691_CR45","doi-asserted-by":"publisher","first-page":"13889","DOI":"10.1021\/acs.analchem.3c02185","volume":"95","author":"C Du","year":"2023","unstructured":"Du, C. et al. Combining Surface-induced dissociation and charge detection mass spectrometry to reveal the native topology of heterogeneous protein complexes. Anal. Chem. 95, 13889\u201313896 (2023).","journal-title":"Anal. Chem."},{"key":"76691_CR46","doi-asserted-by":"publisher","first-page":"1969","DOI":"10.1021\/jasms.4c00222","volume":"35","author":"LM Miller","year":"2024","unstructured":"Miller, L. M., Hawkins, L. & Jarrold, M. F. Compaction, relaxation, and linearization of megadalton-sized DNA plasmids: DNA structures probed by CD-MS. J. Am. Soc. Mass Spectr. 35, 1969\u20131975 (2024).","journal-title":"J. Am. Soc. Mass Spectr."},{"key":"76691_CR47","doi-asserted-by":"publisher","unstructured":"Desligniere, E., Barnes, L. F., Powers, T. W., Friese, O. & Heck, A. J. R. Characterization of intact mRNA-based therapeutics by charge detection mass spectrometry and mass photometry. Mol. Ther. Meth. Clin. D 33, https:\/\/doi.org\/10.1016\/j.omtm.2025.101454 (2025).","DOI":"10.1016\/j.omtm.2025.101454"},{"key":"76691_CR48","doi-asserted-by":"publisher","first-page":"1260","DOI":"10.1126\/science.1248943","volume":"343","author":"CA Diebolder","year":"2014","unstructured":"Diebolder, C. A. et al. Complement is activated by igg hexamers assembled at the cell surface. Science 343, 1260\u20131263 (2014).","journal-title":"Science"},{"key":"76691_CR49","doi-asserted-by":"crossref","unstructured":"Rolland, A. D. & Heck, A. J. R. in Characterizing Biotherapeutics 29\u201354 (2025).","DOI":"10.1002\/9781394236145.ch3"},{"key":"76691_CR50","doi-asserted-by":"publisher","first-page":"11653","DOI":"10.1021\/acs.analchem.5c01000","volume":"97","author":"MD Peris-Diaz","year":"2025","unstructured":"Peris-Diaz, M. D. et al. Electron capture-induced charge reduction benefits the recording of ultralong transients in orbitrap-based individual-ion mass spectrometry. Anal. Chem. 97, 11653\u201311660 (2025).","journal-title":"Anal. Chem."},{"key":"76691_CR51","doi-asserted-by":"publisher","first-page":"5399","DOI":"10.1073\/pnas.97.10.5399","volume":"97","author":"M Graille","year":"2000","unstructured":"Graille, M. et al. Crystal structure of a Staphylococcus aureus protein A domain complexed with the Fab fragment of a human IgM antibody: structural basis for recognition of B-cell receptors and superantigen activity. Proc. Natl. Acad. Sci. USA 97, 5399\u20135404 (2000).","journal-title":"Proc. Natl. Acad. Sci. USA"},{"key":"76691_CR52","doi-asserted-by":"publisher","unstructured":"Cruz, A. R. et al. Staphylococcal protein A inhibits complement activation by interfering with IgG hexamer formation. Proc. Natl. Acad. Sci. USA 118, https:\/\/doi.org\/10.1073\/pnas.2016772118 (2021).","DOI":"10.1073\/pnas.2016772118"},{"key":"76691_CR53","first-page":"979","volume":"10","author":"RN Fong","year":"2018","unstructured":"Fong, R. N. et al. Structural investigation of human targeting antibodies that bind wall teichoic acid. Mabs-Austin 10, 979\u2013991 (2018).","journal-title":"Mabs-Austin"},{"key":"76691_CR54","doi-asserted-by":"publisher","first-page":"1156","DOI":"10.1021\/ac991131p","volume":"72","author":"A Makarov","year":"2000","unstructured":"Makarov, A. Electrostatic axially harmonic orbital trapping: a high-performance technique of mass analysis. Anal. Chem. 72, 1156\u20131162 (2000).","journal-title":"Anal. Chem."},{"key":"76691_CR55","doi-asserted-by":"publisher","first-page":"2113","DOI":"10.1021\/ac0518811","volume":"78","author":"A Makarov","year":"2006","unstructured":"Makarov, A. et al. Performance evaluation of a hybrid linear ion trap\/orbitrap mass spectrometer. Anal. Chem. 78, 2113\u20132120 (2006).","journal-title":"Anal. Chem."},{"key":"76691_CR56","doi-asserted-by":"publisher","first-page":"333","DOI":"10.1038\/nmeth.3771","volume":"13","author":"J Gault","year":"2016","unstructured":"Gault, J. et al. High-resolution mass spectrometry of small molecules bound to membrane proteins. Nat. Methods 13, 333\u2013336 (2016).","journal-title":"Nat. Methods"},{"key":"76691_CR57","doi-asserted-by":"publisher","first-page":"11163","DOI":"10.1021\/ac4029328","volume":"85","author":"ME Belov","year":"2013","unstructured":"Belov, M. E. et al. From protein complexes to subunit backbone fragments: a multi-stage approach to native mass spectrometry. Anal. Chem. 85, 11163\u201311173 (2013).","journal-title":"Anal. Chem."},{"key":"76691_CR58","doi-asserted-by":"publisher","first-page":"2625","DOI":"10.1021\/jasms.3c00340","volume":"34","author":"NP Fisher","year":"2023","unstructured":"Fisher, N. P. et al. Determining Collisional Cross Sections from Ion Decay with Individual Ion Mass Spectrometry. J. Am. Soc. Mass Spectrom. 34, 2625\u20132629 (2023).","journal-title":"J. Am. Soc. Mass Spectrom."},{"key":"76691_CR59","doi-asserted-by":"publisher","first-page":"305","DOI":"10.1016\/S1044-0305(97)00290-0","volume":"9","author":"JC Schultz","year":"1998","unstructured":"Schultz, J. C., Hack, C. A. & Benner, W. H. Mass determination of megadalton-DNA electrospray ions using charge detection mass spectrometry. J. Am. Soc. Mass Spectr. 9, 305\u2013313 (1998).","journal-title":"J. Am. Soc. Mass Spectr."}],"container-title":["Nature Communications"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.nature.com\/articles\/s41467-026-76691-1","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.nature.com\/articles\/s41467-026-76691-1.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.nature.com\/articles\/s41467-026-76691-1.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,9,10]],"date-time":"2026-09-10T00:02:45Z","timestamp":1788998565000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.nature.com\/articles\/s41467-026-76691-1"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,8,13]]},"references-count":59,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2026,12]]}},"alternative-id":["76691"],"URL":"https:\/\/doi.org\/10.1038\/s41467-026-76691-1","relation":{},"ISSN":["2041-1723"],"issn-type":[{"value":"2041-1723","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,8,13]]},"assertion":[{"value":"20 January 2026","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"5 August 2026","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"13 August 2026","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"T.P.W., J.F., K.L.F. and A.A.M. are employees of Thermo Fisher Scientific, a company developing and commercializing Orbitrap mass analyzers. The authors declare there is an UK patent application related to this work, namely No. 2509750.2, in the name of Thermo Fisher Scientific (Bremen) GmbH and Utrecht University for \u201cgas regulation for improved charge detection and native mass spectrometry\u201d.","order":1,"name":"Ethics","label":"Competing interests","group":{"name":"EthicsHeading","label":"Ethics"}}],"article-number":"9690"}}