{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,10]],"date-time":"2026-10-10T20:40:36Z","timestamp":1791664836618,"version":"4.3.4"},"reference-count":27,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2020,10,5]],"date-time":"2020-10-05T00:00:00Z","timestamp":1601856000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2020,10,5]],"date-time":"2020-10-05T00:00:00Z","timestamp":1601856000000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["npj Parkinsons Dis."],"abstract":"<jats:title>Abstract<\/jats:title><jats:p>To compare the differences between asleep and awake robot-assisted deep brain stimulation (DBS) surgery for Parkinson\u2019s Disease (PD), we conducted this retrospective cohort study included 153 PD patients undergoing bilateral robot-assisted DBS from June 2017 to August 2019, of which 58 cases were performed under general anesthesia (GA) and 95 cases under local anesthesia (LA). Procedure duration, stimulation parameters, electrode implantation accuracy, intracranial air, intraoperative electrophysiological signal length, complications, and Unified PD Rating Scale (UPDRS) measurements were recorded and compared. The clinical evaluation was conducted by two raters who were blinded to the choice of anesthesia. Procedure duration was significantly shorter in the GA group, while on stimulation off medication motor scores (UPDRS-III) were significantly improved in both the GA and LA group. ANCOVA covariated for the baseline UPDRS-III and levodopa challenge exhibited no significant differences. In terms of amplitude, frequency, and pulse width, the stimulation parameters used for DBS power-on were similar. There were no significant differences in electrode implantation accuracy, intraoperative electrophysiological signal length, or intracerebral hemorrhage (no occurrences in either group). The pneumocephalus volume was significantly smaller in the GA group. Six patients exhibited transient throat discomfort associated with tracheal intubation in the GA group. The occurrence of surgical incision infection was similar in both groups. Compared with the awake group, the asleep group exhibited a shorter procedure duration with a similar electrode implantation accuracy and short-term motor improvement. Robot-assisted asleep DBS surgery is a promising surgical method for PD.<\/jats:p>","DOI":"10.1038\/s41531-020-00130-1","type":"journal-article","created":{"date-parts":[[2020,10,5]],"date-time":"2020-10-05T10:05:05Z","timestamp":1601892305000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":30,"title":["A comparative study of asleep and awake deep brain stimulation robot-assisted surgery for Parkinson\u2019s disease"],"prefix":"10.1038","volume":"6","author":[{"given":"Hai","family":"Jin","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Shun","family":"Gong","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-2466-1431","authenticated-orcid":false,"given":"Yingqun","family":"Tao","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Hua","family":"Huo","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Xiao","family":"Sun","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Dandan","family":"Song","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ming","family":"Xu","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Zhaozhu","family":"Xu","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yang","family":"Liu","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Shimiao","family":"Wang","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Lijia","family":"Yuan","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Tingting","family":"Wang","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Weilong","family":"Song","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"He","family":"Pan","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2020,10,5]]},"reference":[{"key":"130_CR1","doi-asserted-by":"publisher","first-page":"559","DOI":"10.1007\/s11701-019-01025-x","volume":"14","author":"P Michelle","year":"2020","unstructured":"Michelle, P. et al. Two-year clinical outcomes associated with robotic-assisted subthalamic lead implantation in patients with Parkinson\u2019s disease. J. Robot Surg. 14, 559\u2013565 (2020).","journal-title":"J. Robot Surg."},{"key":"130_CR2","first-page":"7104071","volume":"2019","author":"K Sato","year":"2019","unstructured":"Sato, K. et al. Balance and gait improvements of postoperative rehabilitation in patients with Parkinson\u2019s Disease treated with Subthalamic Nucleus Deep Brain Stimulation (STN-DBS). Parkinsons Dis. 2019, 7104071 (2019).","journal-title":"Parkinsons Dis."},{"key":"130_CR3","doi-asserted-by":"publisher","first-page":"525","DOI":"10.1111\/ner.13081","volume":"23","author":"F Sammartino","year":"2020","unstructured":"Sammartino, F., Rege, R. & Krishna, V. Reliability of intraoperative testing during Deep Brain Stimulation surgery. Neuromodulation 23, 525\u2013529 (2020).","journal-title":"Neuromodulation"},{"key":"130_CR4","doi-asserted-by":"publisher","first-page":"102","DOI":"10.1159\/000443407","volume":"94","author":"DG Southwell","year":"2016","unstructured":"Southwell, D. G. et al. Comparison of Deep Brain Stimulation lead targeting accuracy and procedure duration between 1.5-and 3-Tesla interventional magnetic resonance imaging systems: an initial 12-Month experience. Stereotact. Funct. Neurosurg. 94, 102\u2013107 (2016).","journal-title":"Stereotact. Funct. Neurosurg."},{"key":"130_CR5","doi-asserted-by":"publisher","first-page":"472","DOI":"10.1111\/ner.12918","volume":"22","author":"NI Kremer","year":"2019","unstructured":"Kremer, N. I. et al. Accuracy of intraoperative computed tomography in Deep Brain Stimulation-a prospective non-inferiority study. Neuromodulation 22, 472\u2013477 (2019).","journal-title":"Neuromodulation"},{"key":"130_CR6","doi-asserted-by":"publisher","first-page":"e1121","DOI":"10.1016\/j.wneu.2019.11.117","volume":"134","author":"G Shun","year":"2020","unstructured":"Shun, G. et al. Assessment of Deep Brain Stimulation implantation surgery: a practical scale. World Neurosurg. 134, e1121\u2013e1129 (2020).","journal-title":"World Neurosurg."},{"key":"130_CR7","doi-asserted-by":"publisher","first-page":"893","DOI":"10.1016\/j.brs.2019.03.006","volume":"12","author":"Z Yin","year":"2019","unstructured":"Yin, Z. et al. Is awake physiological confirmation necessary for DBS treatment of Parkinson\u2019s disease today? A comparison of intraoperative imaging, physiology, and physiology imaging-guided DBS in the past decade. Brain Stimul. 12, 893\u2013900 (2019).","journal-title":"Brain Stimul."},{"key":"130_CR8","doi-asserted-by":"publisher","first-page":"902","DOI":"10.3171\/2015.4.JNS1550","volume":"124","author":"Z Mirzadeh","year":"2016","unstructured":"Mirzadeh, Z. et al. Parkinson\u2019s disease outcomes after intraoperative CT-guided \u201casleep\u201d deep brain stimulation in the globus pallidus internus. J. Neurosurg. 124, 902\u2013907 (2016).","journal-title":"J. Neurosurg."},{"key":"130_CR9","doi-asserted-by":"publisher","first-page":"365","DOI":"10.1080\/02688697.2018.1478061","volume":"32","author":"C Chircop","year":"2018","unstructured":"Chircop, C. et al. MRI-verified \u201casleep\u201d deep brain stimulation in Malta through cross border collaboration: clinical outcome of the first five years. Br. J. Neurosurg. 32, 365\u2013371 (2018).","journal-title":"Br. J. Neurosurg."},{"key":"130_CR10","doi-asserted-by":"publisher","first-page":"62","DOI":"10.3171\/2015.1.JNS141534","volume":"124","author":"Z Cui","year":"2016","unstructured":"Cui, Z. et al. Intraoperative MRI for optimizing electrode placement for deep brain stimulation of the subthalamic nucleus in Parkinson disease. J. Neurosurg. 124, 62\u201369 (2016).","journal-title":"J. Neurosurg."},{"key":"130_CR11","doi-asserted-by":"publisher","first-page":"183","DOI":"10.1159\/000475672","volume":"95","author":"M Bot","year":"2017","unstructured":"Bot, M. et al. Accuracy of intraoperative computed tomography during deep brain stimulation procedures: comparison with postoperative magnetic resonance imaging. Stereotact. Funct. Neurosurg. 95, 183\u2013188 (2017).","journal-title":"Stereotact. Funct. Neurosurg."},{"key":"130_CR12","doi-asserted-by":"crossref","first-page":"1","DOI":"10.3171\/2017.9.JNS171609","volume":"16","author":"T Chen","year":"2018","unstructured":"Chen, T. et al. Clinical outcomes following awake and asleep deep brain stimulation for Parkinson disease. J. Neurosurg. 16, 1\u201312 (2018).","journal-title":"J. Neurosurg."},{"key":"130_CR13","doi-asserted-by":"publisher","first-page":"541","DOI":"10.1111\/ner.12766","volume":"21","author":"F Blasberg","year":"2018","unstructured":"Blasberg, F. et al. Comparison of awake vs. asleep surgery for subthalamic deep brain stimulation in Parkinson\u2019s disease. Neuromodulation 21, 541\u2013547 (2018).","journal-title":"Neuromodulation"},{"key":"130_CR14","doi-asserted-by":"publisher","first-page":"1944","DOI":"10.1212\/WNL.0000000000004630","volume":"89","author":"MA Brodsky","year":"2017","unstructured":"Brodsky, M. A. et al. Clinical outcomes of asleep vs awake deep brain stimulation for Parkinson disease. Neurology 89, 1944\u20131950 (2017).","journal-title":"Neurology"},{"key":"130_CR15","doi-asserted-by":"publisher","first-page":"E17","DOI":"10.3390\/brainsci8010017","volume":"8","author":"RB Kochanski","year":"2018","unstructured":"Kochanski, R. B. & Sani, S. Awake versus asleep deep brain stimulation surgery: technical considerations and critical review of the literature. Brain Sci. 8, E17 (2018).","journal-title":"Brain Sci."},{"key":"130_CR16","doi-asserted-by":"publisher","first-page":"1572","DOI":"10.3171\/2017.7.JNS171166","volume":"129","author":"MM Caio","year":"2018","unstructured":"Caio, M. M. et al. Deep brain stimulation outcomes in patients implanted under general anesthesia with frame-based stereotaxy and intraoperative MRI. J. Neurosurg. 129, 1572\u20131578 (2018).","journal-title":"J. Neurosurg."},{"key":"130_CR17","doi-asserted-by":"publisher","first-page":"381","DOI":"10.1159\/000505079","volume":"97","author":"Z Liu","year":"2019","unstructured":"Liu, Z., He, S. & Li, L. General anesthesia versus local anesthesia for deep brain stimulation in Parkinson\u2019s disease: a meta-analysis. Stereotact. Funct. Neurosurg. 97, 381\u2013390 (2019).","journal-title":"Stereotact. Funct. Neurosurg."},{"key":"130_CR18","first-page":"E18","volume":"45","author":"X Feng","year":"2018","unstructured":"Feng, X. et al. Improved accuracy using a modified registration method of ROSA in deep brain stimulation surgery. Neurosurg. Focus 45, E18 (2018).","journal-title":"Neurosurg. Focus"},{"key":"130_CR19","doi-asserted-by":"publisher","first-page":"70","DOI":"10.1093\/ons\/opy291","volume":"17","author":"Z Mirzadeh","year":"2019","unstructured":"Mirzadeh, Z. et al. Procedural variables influencing stereotactic accuracy and efficiency in deep brain stimulation surgery. Oper. Neurosurg. 17, 70\u201378 (2019).","journal-title":"Oper. Neurosurg."},{"key":"130_CR20","doi-asserted-by":"publisher","first-page":"444","DOI":"10.1111\/ner.13061","volume":"23","author":"W Jun","year":"2020","unstructured":"Jun, W. et al. Comparison of awake and asleep deep brain stimulation for Parkinson\u2019s disease: a detailed analysis through literature review. Neuromodulation 23, 444\u2013450 (2020).","journal-title":"Neuromodulation"},{"key":"130_CR21","doi-asserted-by":"publisher","first-page":"107","DOI":"10.3171\/2011.7.JNS11319","volume":"116","author":"AM Harries","year":"2012","unstructured":"Harries, A. M. et al. Deep brain stimulation of the subthalamic nucleus for advanced Parkinson disease using general anesthesia: long-term results. J. Neurosurg. 116, 107\u2013113 (2012).","journal-title":"J. Neurosurg."},{"key":"130_CR22","first-page":"5676345","volume":"2019","author":"T Sheng-Tzung","year":"2019","unstructured":"Sheng-Tzung, T. et al. Five-year clinical outcomes of local versus general anesthesia deep brain stimulation for Parkinson\u2019s disease. Parkinson\u2019s Dis. 2019, 5676345 (2019).","journal-title":"Parkinson\u2019s Dis."},{"key":"130_CR23","doi-asserted-by":"publisher","first-page":"687","DOI":"10.1136\/jnnp-2016-314500","volume":"89","author":"A Ho","year":"2018","unstructured":"Ho, A. et al. Awake versus asleep deep brain stimulation for Parkinson\u2019s disease: a critical comparison and meta-analysis. J. Neurol. Neurosurg. Psychiatry 89, 687\u2013691 (2018).","journal-title":"J. Neurol. Neurosurg. Psychiatry"},{"key":"130_CR24","doi-asserted-by":"publisher","first-page":"360","DOI":"10.3171\/2016.6.JNS152946","volume":"127","author":"T Chen","year":"2017","unstructured":"Chen, T. et al. Complication rates, lengths of stay, and readmission rates in \u201cawake\u201d and \u201casleep\u201d deep brain stimulation. J. Neurosurg. 127, 360\u2013369 (2017).","journal-title":"J. Neurosurg."},{"key":"130_CR25","doi-asserted-by":"publisher","first-page":"83","DOI":"10.1159\/000488150","volume":"96","author":"AL Ko","year":"2018","unstructured":"Ko, A. L. et al. Asleep deep brain stimulation reduces incidence of intracranial air during electrode implantation. Stereotact. Funct. Neurosurg. 96, 83\u201390 (2018).","journal-title":"Stereotact. Funct. Neurosurg."},{"key":"130_CR26","doi-asserted-by":"publisher","first-page":"191","DOI":"10.1016\/j.wneu.2017.05.042","volume":"105","author":"T Chen","year":"2017","unstructured":"Chen, T., Mirzadeh, Z. & Ponce, F. A. \u201cAsleep\u201d Deep Brain Stimulation surgery: acritical review of the literature. World Neurosurg. 105, 191\u2013198 (2017).","journal-title":"World Neurosurg."},{"key":"130_CR27","doi-asserted-by":"publisher","first-page":"1517","DOI":"10.3171\/2015.5.JNS15433","volume":"124","author":"RL Jacob","year":"2016","unstructured":"Jacob, R. L. et al. Cost analysis of awake versus asleep deep brain stimulation: a single academic health center experience. J. Neurosurg. 124, 1517\u20131523 (2016).","journal-title":"J. Neurosurg."}],"container-title":["npj Parkinson's Disease"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.nature.com\/articles\/s41531-020-00130-1.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.nature.com\/articles\/s41531-020-00130-1","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.nature.com\/articles\/s41531-020-00130-1.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,10,9]],"date-time":"2023-10-09T01:18:14Z","timestamp":1696814294000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.nature.com\/articles\/s41531-020-00130-1"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2020,10,5]]},"references-count":27,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2020,12]]}},"alternative-id":["130"],"URL":"https:\/\/doi.org\/10.1038\/s41531-020-00130-1","relation":{},"ISSN":["2373-8057"],"issn-type":[{"value":"2373-8057","type":"electronic"}],"subject":[],"published":{"date-parts":[[2020,10,5]]},"assertion":[{"value":"29 February 2020","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"2 September 2020","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"5 October 2020","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"The authors declare no competing interests.","order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"27"}}