{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,30]],"date-time":"2026-10-30T17:36:19Z","timestamp":1793381779164,"version":"4.5.0"},"reference-count":60,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2026,1,15]],"date-time":"2026-01-15T00:00:00Z","timestamp":1768435200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0"},{"start":{"date-parts":[[2026,1,30]],"date-time":"2026-01-30T00:00:00Z","timestamp":1769731200000},"content-version":"vor","delay-in-days":15,"URL":"https:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0"}],"funder":[{"DOI":"10.13039\/100020415","name":"Additional Ventures","doi-asserted-by":"publisher","id":[{"id":"10.13039\/100020415","id-type":"DOI","asserted-by":"publisher"}]},{"name":"Additional Ventures, United States"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["npj Regen Med"],"DOI":"10.1038\/s41536-025-00450-x","type":"journal-article","created":{"date-parts":[[2026,1,15]],"date-time":"2026-01-15T17:44:17Z","timestamp":1768499057000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":1,"title":["Optimized biomechanical design of a tissue engineered pulsatile Fontan conduit"],"prefix":"10.1038","volume":"11","author":[{"given":"Nir","family":"Emuna","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Zinan","family":"Hu","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Alison L.","family":"Marsden","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jay D.","family":"Humphrey","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2026,1,15]]},"reference":[{"key":"450_CR1","doi-asserted-by":"publisher","first-page":"520","DOI":"10.1038\/nrcardio.2010.99","volume":"7","author":"MR de Leval","year":"2010","unstructured":"de Leval, M. R. & Deanfield, J. E. Four decades of Fontan palliation. Nat. Rev. Cardiol. 7, 520\u2013527 (2010).","journal-title":"Nat. Rev. Cardiol."},{"key":"450_CR2","doi-asserted-by":"publisher","first-page":"1866","DOI":"10.1016\/j.amjcard.2017.03.004","volume":"119","author":"KY Allen","year":"2017","unstructured":"Allen, K. Y. et al. Effect of Fontan-associated morbidities on survival with intact Fontan circulation. Am. J. Cardiol. 119, 1866\u20131871 (2017).","journal-title":"Am. J. Cardiol."},{"key":"450_CR3","doi-asserted-by":"publisher","first-page":"1070","DOI":"10.1017\/S1047951120001869","volume":"30","author":"T Alsaied","year":"2020","unstructured":"Alsaied, T. et al. The Fontan outcomes network: first steps towards building a lifespan registry for individuals with Fontan circulation in the United States. Cardiol. Young 30, 1070\u20131075 (2020).","journal-title":"Cardiol. Young"},{"key":"450_CR4","doi-asserted-by":"publisher","first-page":"e234","DOI":"10.1161\/CIR.0000000000000696","volume":"140","author":"J Rychik","year":"2019","unstructured":"Rychik, J. et al. Evaluation and management of the child and adult with Fontan circulation: a scientific statement from the American Heart Association. Circulation 140, e234\u2013e284 (2019).","journal-title":"Circulation"},{"key":"450_CR5","doi-asserted-by":"publisher","DOI":"10.1161\/JAHA.119.013691","volume":"9","author":"S Kutty","year":"2020","unstructured":"Kutty, S., Jacobs, M. L., Thompson, W. R. & Danford, D. A. Fontan circulation of the next generation: why it\u2019s necessary, what it might look like. J. Am. Heart Assoc. 9, e013691 (2020).","journal-title":"J. Am. Heart Assoc."},{"key":"450_CR6","doi-asserted-by":"publisher","first-page":"45499","DOI":"10.1038\/srep45499","volume":"7","author":"H Seta","year":"2017","unstructured":"Seta, H., Matsuura, K., Sekine, H., Yamazaki, K. & Shimizu, T. Tubular cardiac tissues derived from human induced pluripotent stem cells generate pulse pressure in vivo. Sci. Rep. 7, 45499 (2017).","journal-title":"Sci. Rep."},{"key":"450_CR7","doi-asserted-by":"publisher","first-page":"297","DOI":"10.1016\/j.reth.2019.09.001","volume":"11","author":"S Tsuruyama","year":"2019","unstructured":"Tsuruyama, S., Matsuura, K., Sakaguchi, K. & Shimizu, T. Pulsatile tubular cardiac tissues fabricated by wrapping human iPS cells-derived cardiomyocyte sheets. Regen. Ther. 11, 297\u2013305 (2019).","journal-title":"Regen. Ther."},{"key":"450_CR8","doi-asserted-by":"publisher","first-page":"220","DOI":"10.1016\/j.actbio.2019.10.019","volume":"102","author":"J Park","year":"2020","unstructured":"Park, J. et al. Modular design of a tissue engineered pulsatile conduit using human induced pluripotent stem cell-derived cardiomyocytes. Acta Biomater. 102, 220\u2013230 (2020).","journal-title":"Acta Biomater."},{"key":"450_CR9","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1038\/s41536-022-00218-7","volume":"7","author":"Y Endo","year":"2022","unstructured":"Endo, Y. et al. Bioartificial pulsatile cuffs fabricated from human induced pluripotent stem cell-derived cardiomyocytes using a pre-vascularization technique. Npj Regen. Med. 7, 1\u201310 (2022).","journal-title":"Npj Regen. Med."},{"key":"450_CR10","doi-asserted-by":"publisher","DOI":"10.1093\/ejcts\/ezac111","volume":"62","author":"M K\u00f6hne","year":"2022","unstructured":"K\u00f6hne, M. et al. A potential future Fontan modification: preliminary in vitro data of a pressure-generating tube from engineered heart tissue. Eur. J. Cardiothorac. Surg. 62, ezac111 (2022).","journal-title":"Eur. J. Cardiothorac. Surg."},{"key":"450_CR11","doi-asserted-by":"publisher","first-page":"111568","DOI":"10.1016\/j.jbiomech.2023.111568","volume":"152","author":"E Ban","year":"2023","unstructured":"Ban, E. & Humphrey, J. D. New computational approach to shunt design in congenital heart palliation. J. Biomech. 152, 111568 (2023).","journal-title":"J. Biomech."},{"key":"450_CR12","doi-asserted-by":"publisher","first-page":"996","DOI":"10.1016\/j.ejcts.2009.12.010","volume":"37","author":"Y Ochiai","year":"2010","unstructured":"Ochiai, Y. et al. Longitudinal growth of the autologous vessels above and below the Gore-Tex graft after the extracardiac conduit Fontan procedure. Eur. J. Cardiothorac. Surg. 37, 996\u20131001 (2010).","journal-title":"Eur. J. Cardiothorac. Surg."},{"key":"450_CR13","doi-asserted-by":"publisher","first-page":"1091","DOI":"10.7863\/ultra.34.6.1091","volume":"34","author":"N Kathuria","year":"2015","unstructured":"Kathuria, N., Ng, L., Saul, T. & Lewiss, R. E. The baseline diameter of the inferior vena cava measured by sonography increases with age in normovolemic children. J. Ultrasound Med. 34, 1091\u20131096 (2015).","journal-title":"J. Ultrasound Med."},{"key":"450_CR14","doi-asserted-by":"publisher","first-page":"445","DOI":"10.1152\/japplphysiol.01144.2004","volume":"99","author":"T Sluysmans","year":"2005","unstructured":"Sluysmans, T. & Colan, S. D. Theoretical and empirical derivation of cardiovascular allometric relationships in children. J. Appl. Physiol. 99, 445\u2013457 (2005).","journal-title":"J. Appl. Physiol."},{"key":"450_CR15","doi-asserted-by":"publisher","first-page":"071001","DOI":"10.1115\/1.4068319","volume":"147","author":"Z Hu","year":"2025","unstructured":"Hu, Z. et al. Multiphysics simulations of a bioprinted pulsatile Fontan conduit. J. Biomech. Eng. 147, 071001 (2025).","journal-title":"J. Biomech. Eng."},{"key":"450_CR16","doi-asserted-by":"publisher","first-page":"144","DOI":"10.1161\/01.CIR.47.1.144","volume":"47","author":"TP Graham","year":"1973","unstructured":"Graham, T. P., Jarmakani, J. M., Atwood, G. F. & Canent, R. V. Right ventricular volume determinations in children. Circulation 47, 144\u2013153 (1973).","journal-title":"Circulation"},{"key":"450_CR17","doi-asserted-by":"publisher","first-page":"690","DOI":"10.1016\/S1010-7940(00)00593-5","volume":"18","author":"V Alexi-Meskishvili","year":"2000","unstructured":"Alexi-Meskishvili, V. et al. Optimal conduit size for extracardiac Fontan operation. Eur. J. Cardiothorac. Surg. 18, 690\u2013695 (2000).","journal-title":"Eur. J. Cardiothorac. Surg."},{"key":"450_CR18","doi-asserted-by":"publisher","first-page":"1008","DOI":"10.1016\/j.ejcts.2007.03.013","volume":"31","author":"C Lee","year":"2007","unstructured":"Lee, C. et al. Midterm follow-up of the status of Gore-Tex graft after extracardiac conduit Fontan procedure. Eur. J. Cardiothorac. Surg. 31, 1008\u20131012 (2007).","journal-title":"Eur. J. Cardiothorac. Surg."},{"key":"450_CR19","doi-asserted-by":"publisher","first-page":"84","DOI":"10.1016\/j.echo.2007.05.009","volume":"21","author":"X Lu","year":"2008","unstructured":"Lu, X. et al. Accuracy and reproducibility of real-time three-dimensional echocardiography for assessment of right ventricular volumes and ejection fraction in children. J. Am. Soc. Echocardiogr. 21, 84\u201389 (2008).","journal-title":"J. Am. Soc. Echocardiogr."},{"key":"450_CR20","doi-asserted-by":"publisher","first-page":"1875","DOI":"10.1097\/CCM.0b013e3181e8adee","volume":"38","author":"GN Cattermole","year":"2010","unstructured":"Cattermole, G. N. et al. The normal ranges of cardiovascular parameters in children measured using the ultrasonic cardiac output monitor. Crit. Care Med. 38, 1875 (2010).","journal-title":"Crit. Care Med."},{"key":"450_CR21","doi-asserted-by":"publisher","first-page":"1860","DOI":"10.1161\/01.CIR.92.7.1860","volume":"92","author":"MA Salim","year":"1995","unstructured":"Salim, M. A., DiSessa, T. G., Arheart, K. L. & Alpert, B. S. Contribution of superior vena caval flow to total cardiac output in children. Circulation 92, 1860\u20131865 (1995).","journal-title":"Circulation"},{"key":"450_CR22","doi-asserted-by":"publisher","first-page":"1837","DOI":"10.1161\/01.CIR.95.7.1837","volume":"95","author":"G de Simone","year":"1997","unstructured":"de Simone, G. et al. Stroke volume and cardiac output in normotensive children and adults. Circulation 95, 1837\u20131843 (1997).","journal-title":"Circulation"},{"key":"450_CR23","doi-asserted-by":"publisher","first-page":"565","DOI":"10.1016\/j.athoracsur.2009.04.109","volume":"88","author":"K Itatani","year":"2009","unstructured":"Itatani, K. et al. Optimal conduit size of the extracardiac Fontan operation based on energy loss and flow stagnation. Ann. Thorac. Surg. 88, 565\u2013573 (2009).","journal-title":"Ann. Thorac. Surg."},{"key":"450_CR24","doi-asserted-by":"publisher","first-page":"726","DOI":"10.1016\/0002-8703(84)90321-1","volume":"107","author":"RA Hurwitz","year":"1984","unstructured":"Hurwitz, R. A., Treves, S. & Kuruc, A. Right ventricular and left ventricular ejection fraction in pediatric patients with normal hearts: first-pass radionuclide angiocardiography. Am. Heart J. 107, 726\u2013732 (1984).","journal-title":"Am. Heart J."},{"key":"450_CR25","doi-asserted-by":"publisher","DOI":"10.1126\/scitranslmed.aax6919","volume":"12","author":"JD Drews","year":"2020","unstructured":"Drews, J. D. et al. Spontaneous reversal of stenosis in tissue-engineered vascular grafts. Sci. Transl. Med. 12, eaax6919 (2020).","journal-title":"Sci. Transl. Med."},{"key":"450_CR26","doi-asserted-by":"publisher","first-page":"805","DOI":"10.1161\/01.RES.65.3.805","volume":"65","author":"JD Humphrey","year":"1989","unstructured":"Humphrey, J. D. & Yin, F. C. Constitutive relations and finite deformations of passive cardiac tissue II: stress analysis in the left ventricle. Circ. Res. 65, 805\u2013817 (1989).","journal-title":"Circ. Res."},{"key":"450_CR27","doi-asserted-by":"crossref","unstructured":"Emuna, N. & Cohen, N. Inflation-induced twist in geometrically incompatible isotropic tubes. J. Appl. Mech. 88, 031005 (2020).","DOI":"10.1115\/1.4047980"},{"key":"450_CR28","first-page":"20130011","volume":"469","author":"A Goriely","year":"2013","unstructured":"Goriely, A. & Tabor, M. Rotation, inversion and perversion in anisotropic elastic cylindrical tubes and membranes. Proc. R. Soc. Math. Phys. Eng. Sci. 469, 20130011 (2013).","journal-title":"Proc. R. Soc. Math. Phys. Eng. Sci."},{"key":"450_CR29","doi-asserted-by":"publisher","first-page":"2001","DOI":"10.1007\/s10237-021-01489-7","volume":"20","author":"A Sharifi","year":"2021","unstructured":"Sharifi, A., Gendernalik, A., Garrity, D. & Bark, D. Valveless pumping behavior of the simulated embryonic heart tube as a function of contractile patterns and myocardial stiffness. Biomech. Model. Mechanobiol. 20, 2001\u20132012 (2021).","journal-title":"Biomech. Model. Mechanobiol."},{"key":"450_CR30","doi-asserted-by":"crossref","unstructured":"Humphrey, J. D. Cardiovascular Solid Mechanics: Cells, Tissues, and Organs (Springer-Verlag, 2002).","DOI":"10.1007\/978-0-387-21576-1"},{"key":"450_CR31","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1038\/s43856-021-00063-7","volume":"2","author":"KM Blum","year":"2022","unstructured":"Blum, K. M. et al. Tissue engineered vascular grafts transform into autologous neovessels capable of native function and growth. Commun. Med. 2, 1\u201321 (2022).","journal-title":"Commun. Med."},{"key":"450_CR32","doi-asserted-by":"publisher","first-page":"417","DOI":"10.1146\/annurev-bioeng-062117-121129","volume":"21","author":"R Avazmohammadi","year":"2019","unstructured":"Avazmohammadi, R. et al. A contemporary look at biomechanical models of myocardium. Annu. Rev. Biomed. Eng. 21, 417\u2013442 (2019).","journal-title":"Annu. Rev. Biomed. Eng."},{"key":"450_CR33","unstructured":"Payan, Y. & Ohayon, J. Biomechanics of Living Organs: Hyperelastic Constitutive Laws for Finite Element Modeling (Academic Press, 2017)."},{"key":"450_CR34","doi-asserted-by":"publisher","first-page":"20","DOI":"10.1016\/j.jmps.2014.07.015","volume":"72","author":"S G\u00f6ktepe","year":"2014","unstructured":"G\u00f6ktepe, S., Menzel, A. & Kuhl, E. The generalized Hill model: a kinematic approach towards active muscle contraction. J. Mech. Phys. Solids 72, 20\u201339 (2014).","journal-title":"J. Mech. Phys. Solids"},{"key":"450_CR35","doi-asserted-by":"publisher","first-page":"101303","DOI":"10.1016\/j.eml.2021.101303","volume":"46","author":"N Emuna","year":"2021","unstructured":"Emuna, N. & Cohen, N. Inversion and perversion in twist incompatible isotropic tubes. Extreme Mech. Lett. 46, 101303 (2021).","journal-title":"Extreme Mech. Lett."},{"key":"450_CR36","doi-asserted-by":"publisher","first-page":"428","DOI":"10.1510\/icvts.2009.218594","volume":"10","author":"M Gewillig","year":"2010","unstructured":"Gewillig, M. et al. The Fontan circulation: who controls cardiac output? Interact. Cardiovasc. Thorac. Surg. 10, 428\u2013433 (2010).","journal-title":"Interact. Cardiovasc. Thorac. Surg."},{"key":"450_CR37","doi-asserted-by":"publisher","first-page":"011002","DOI":"10.1115\/1.4023089","volume":"135","author":"W Yang","year":"2013","unstructured":"Yang, W., Feinstein, J. A., Shadden, S. C., Vignon-Clementel, I. E. & Marsden, A. L. Optimization of a Y-graft design for improved hepatic flow distribution in the Fontan circulation. J. Biomech. Eng. 135, 011002 (2013).","journal-title":"J. Biomech. Eng."},{"key":"450_CR38","doi-asserted-by":"publisher","first-page":"200","DOI":"10.1016\/j.cma.2012.12.013","volume":"256","author":"S Sankaran","year":"2013","unstructured":"Sankaran, S., Humphrey, J. D. & Marsden, A. L. An efficient framework for optimization and parameter sensitivity analysis in arterial growth and remodeling computations. Comput. Methods Appl. Mech. Eng. 256, 200\u2013210 (2013).","journal-title":"Comput. Methods Appl. Mech. Eng."},{"key":"450_CR39","doi-asserted-by":"publisher","first-page":"561","DOI":"10.1089\/ten.tec.2019.0086","volume":"25","author":"JM Szafron","year":"2019","unstructured":"Szafron, J. M., Ramachandra, A. B., Breuer, C. K., Marsden, A. L. & Humphrey, J. D. Optimization of tissue-engineered vascular graft design using computational modeling. Tissue Eng. Part C Methods 25, 561\u2013570 (2019).","journal-title":"Tissue Eng. Part C Methods"},{"key":"450_CR40","doi-asserted-by":"crossref","unstructured":"Emuna, N., Durban, D. & Osovski, S. Sensitivity of arterial hyperelastic models to uncertainties in stress-free measurements. J. Biomech. Eng. 140 (2018).","DOI":"10.1115\/1.4040400"},{"key":"450_CR41","first-page":"1","volume":"6","author":"EL Schwarz","year":"2021","unstructured":"Schwarz, E. L. et al. Hemodynamic performance of tissue-engineered vascular grafts in Fontan patients. Npj Regen. Med. 6, 1\u201317 (2021).","journal-title":"Npj Regen. Med."},{"key":"450_CR42","doi-asserted-by":"publisher","first-page":"611","DOI":"10.1161\/01.RES.28.6.611","volume":"28","author":"JW Burns","year":"1971","unstructured":"Burns, J. W., Covell, J. W., Myers, R. & ROSS, J. Jr Comparison of directly measured left ventricular wall stress and stress calculated from geometric reference figures. Circ. Res. 28, 611\u2013621 (1971).","journal-title":"Circ. Res."},{"key":"450_CR43","doi-asserted-by":"publisher","first-page":"399","DOI":"10.1161\/ATVBAHA.122.318236","volume":"43","author":"T Breuer","year":"2023","unstructured":"Breuer, T., Jimenez, M., Humphrey, J. D., Shinoka, T. & Breuer, C. K. Tissue engineering of vascular grafts: a case report from bench to bedside and back. Arterioscler. Thromb. Vasc. Biol. 43, 399\u2013409 (2023).","journal-title":"Arterioscler. Thromb. Vasc. Biol."},{"key":"450_CR44","doi-asserted-by":"publisher","DOI":"10.1038\/s41467-024-46431-4","volume":"15","author":"ME Turner","year":"2024","unstructured":"Turner, M. E. et al. Tissue engineered vascular grafts are resistant to the formation of dystrophic calcification. Nat. Commun. 15, 2187 (2024).","journal-title":"Nat. Commun."},{"key":"450_CR45","doi-asserted-by":"publisher","first-page":"826","DOI":"10.1016\/j.athoracsur.2008.10.075","volume":"87","author":"S Ovroutski","year":"2009","unstructured":"Ovroutski, S. et al. Absence of pulmonary artery growth after Fontan operation and its possible impact on late outcome. Ann. Thorac. Surg. 87, 826\u2013831 (2009).","journal-title":"Ann. Thorac. Surg."},{"key":"450_CR46","doi-asserted-by":"publisher","first-page":"99","DOI":"10.4250\/jcvi.2021.0133","volume":"30","author":"R Shabanian","year":"2022","unstructured":"Shabanian, R. et al. Pulsatility index in different modifications of Fontan palliation: an echocardiographic assessment. J. Cardiovasc. Imaging 30, 99\u2013108 (2022).","journal-title":"J. Cardiovasc. Imaging"},{"key":"450_CR47","doi-asserted-by":"publisher","unstructured":"Rego, B. V., Murtada, S.-I., Li, G., Tellides, G. & Humphrey, J. D. Multiscale insights into postnatal aortic development. Biomech. Model. Mechanobiol. https:\/\/doi.org\/10.1007\/s10237-023-01800-8 (2023).","DOI":"10.1007\/s10237-023-01800-8"},{"key":"450_CR48","doi-asserted-by":"publisher","first-page":"e0166963","DOI":"10.1371\/journal.pone.0166963","volume":"11","author":"D Biermann","year":"2016","unstructured":"Biermann, D. et al. Towards a tissue-engineered contractile Fontan-conduit: the fate of cardiac myocytes in the subpulmonary circulation. PLoS ONE 11, e0166963 (2016).","journal-title":"PLoS ONE"},{"key":"450_CR49","doi-asserted-by":"publisher","first-page":"604","DOI":"10.1016\/j.jbiomech.2014.12.054","volume":"48","author":"A Palit","year":"2015","unstructured":"Palit, A., Bhudia, S. K., Arvanitis, T. N., Turley, G. A. & Williams, M. A. Computational modelling of left-ventricular diastolic mechanics: Effect of fibre orientation and right-ventricle topology. J. Biomech. 48, 604\u2013612 (2015).","journal-title":"J. Biomech."},{"key":"450_CR50","doi-asserted-by":"publisher","first-page":"104","DOI":"10.1111\/j.1747-0803.2010.00383.x","volume":"5","author":"AL Marsden","year":"2010","unstructured":"Marsden, A. L. et al. A new multiparameter approach to computational simulation for Fontan assessment and redesign. Congenit. Heart Dis. 5, 104\u2013117 (2010).","journal-title":"Congenit. Heart Dis."},{"key":"450_CR51","doi-asserted-by":"publisher","first-page":"H1056","DOI":"10.1152\/ajpheart.00245.2014","volume":"307","author":"F Liang","year":"2014","unstructured":"Liang, F. et al. Hemodynamic performance of the Fontan circulation compared with a normal biventricular circulation: a computational model study. Am. J. Physiol. Heart Circ. Physiol. 307, H1056\u2013H1072 (2014).","journal-title":"Am. J. Physiol. Heart Circ. Physiol."},{"key":"450_CR52","doi-asserted-by":"publisher","first-page":"712","DOI":"10.1016\/j.jtcvs.2017.09.046","volume":"155","author":"T Conover","year":"2018","unstructured":"Conover, T. et al. An interactive simulation tool for patient-specific clinical decision support in single-ventricle physiology. J. Thorac. Cardiovasc. Surg. 155, 712\u2013721 (2018).","journal-title":"J. Thorac. Cardiovasc. Surg."},{"key":"450_CR53","doi-asserted-by":"crossref","unstructured":"Morrison, T. M., Pathmanathan, P., Adwan, M. & Margerrison, E. Advancing regulatory science with computational modeling for medical devices at the FDA\u2019s Office of Science and Engineering Laboratories. Front. Med. 5, 241 (2018).","DOI":"10.3389\/fmed.2018.00241"},{"key":"450_CR54","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1038\/s41536-021-00134-2","volume":"6","author":"SL Waters","year":"2021","unstructured":"Waters, S. L., Schumacher, L. J. & El Haj, A. J. Regenerative medicine meets mathematical modelling: developing symbiotic relationships. Npj Regen. Med. 6, 1\u20138 (2021).","journal-title":"Npj Regen. Med."},{"key":"450_CR55","doi-asserted-by":"publisher","first-page":"45","DOI":"10.1007\/s10439-022-03037-5","volume":"51","author":"S Loerakker","year":"2023","unstructured":"Loerakker, S. & Humphrey, J. D. Computer model-driven design in cardiovascular regenerative medicine. Ann. Biomed. Eng. 51, 45\u201357 (2023).","journal-title":"Ann. Biomed. Eng."},{"key":"450_CR56","doi-asserted-by":"publisher","first-page":"H101","DOI":"10.1152\/ajpheart.1990.259.1.H101","volume":"259","author":"JD Humphrey","year":"1990","unstructured":"Humphrey, J. D., Strumpf, R. K. & Yin, F. C. Biaxial mechanical behavior of excised ventricular epicardium. Am. J. Physiol. Heart Circ. Physiol. 259, H101\u2013H108 (1990).","journal-title":"Am. J. Physiol. Heart Circ. Physiol."},{"key":"450_CR57","doi-asserted-by":"publisher","first-page":"67","DOI":"10.1148\/radiol.12120778","volume":"267","author":"P B\u00e4chler","year":"2013","unstructured":"B\u00e4chler, P. et al. Caval blood flow distribution in patients with Fontan circulation: quantification by using particle traces from 4D flow MR imaging. Radiology 267, 67\u201375 (2013).","journal-title":"Radiology"},{"key":"450_CR58","doi-asserted-by":"crossref","unstructured":"Emuna, N. & Durban, D. Stability analysis of arteries under torsion. J. Biomech. Eng. 142, 061011 (2020).","DOI":"10.1115\/1.4046051"},{"key":"450_CR59","doi-asserted-by":"publisher","first-page":"116312","DOI":"10.1016\/j.cma.2023.116312","volume":"417","author":"EL Schwarz","year":"2023","unstructured":"Schwarz, E. L. et al. A fluid\u2013solid-growth solver for cardiovascular modeling. Comput. Methods Appl. Mech. Eng. 417, 116312 (2023).","journal-title":"Comput. Methods Appl. Mech. Eng."},{"key":"450_CR60","doi-asserted-by":"publisher","first-page":"954","DOI":"10.1016\/S0006-3495(69)86429-5","volume":"9","author":"EA Sallin","year":"1969","unstructured":"Sallin, E. A. Fiber orientation and ejection fraction in the human left ventricle. Biophys. J. 9, 954\u2013964 (1969).","journal-title":"Biophys. J."}],"container-title":["npj Regenerative Medicine"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.nature.com\/articles\/s41536-025-00450-x","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.nature.com\/articles\/s41536-025-00450-x.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.nature.com\/articles\/s41536-025-00450-x.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,1,30]],"date-time":"2026-01-30T17:03:13Z","timestamp":1769792593000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.nature.com\/articles\/s41536-025-00450-x"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,1,15]]},"references-count":60,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2026,12]]}},"alternative-id":["450"],"URL":"https:\/\/doi.org\/10.1038\/s41536-025-00450-x","relation":{},"ISSN":["2057-3995"],"issn-type":[{"value":"2057-3995","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,1,15]]},"assertion":[{"value":"11 October 2025","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"13 December 2025","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"15 January 2026","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"The authors declare no competing interests.","order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"6"}}