{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,1]],"date-time":"2026-10-01T01:12:13Z","timestamp":1790817133577,"version":"4.1.0"},"reference-count":119,"publisher":"Springer Science and Business Media LLC","issue":"7","license":[{"start":{"date-parts":[[2021,4,15]],"date-time":"2021-04-15T00:00:00Z","timestamp":1618444800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.springernature.com\/gp\/researchers\/text-and-data-mining"},{"start":{"date-parts":[[2021,4,15]],"date-time":"2021-04-15T00:00:00Z","timestamp":1618444800000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/www.springernature.com\/gp\/researchers\/text-and-data-mining"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Nat. Mater."],"published-print":{"date-parts":[[2021,7]]},"DOI":"10.1038\/s41563-021-00966-9","type":"journal-article","created":{"date-parts":[[2021,4,15]],"date-time":"2021-04-15T12:03:25Z","timestamp":1618488205000},"page":"925-939","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":305,"title":["Sensory feedback for limb prostheses in amputees"],"prefix":"10.1038","volume":"20","author":[{"ORCID":"https:\/\/orcid.org\/0000-0003-0567-9051","authenticated-orcid":false,"given":"Stanisa","family":"Raspopovic","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-2637-8007","authenticated-orcid":false,"given":"Giacomo","family":"Valle","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Francesco Maria","family":"Petrini","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2021,4,15]]},"reference":[{"key":"966_CR1","first-page":"328","volume":"87","author":"N Unwin","year":"2000","unstructured":"Unwin, N. Epidemiology of lower extremity amputation in centres in Europe, North America and East Asia. Br. J. Surg. 87, 328\u2013337 (2000).","journal-title":"Br. J. Surg."},{"key":"966_CR2","doi-asserted-by":"publisher","first-page":"1144","DOI":"10.1111\/j.1464-5491.2011.03279.x","volume":"28","author":"PW Moxey","year":"2011","unstructured":"Moxey, P. W. et al. Lower extremity amputations\u2014a review of global variability in incidence. Diabet. Med. 28, 1144\u20131153 (2011).","journal-title":"Diabet. Med."},{"key":"966_CR3","unstructured":"Winkler, S. L. H. in Care of the Combat Amputee (eds Pasquina, P. F. et al.) 597\u2013605 (Department of the Army, 2009)."},{"key":"966_CR4","unstructured":"Sanit\u00e0 solo il 5 di amputazioni \u00e8 legata a infortuni sul lavoro. INAIL https:\/\/www.inail.it\/cs\/internet\/comunicazione\/news-ed-eventi\/news\/p1780018061_sanita_solo_il_5_di_amputazi.html (2010)."},{"key":"966_CR5","doi-asserted-by":"publisher","first-page":"343","DOI":"10.1016\/S0749-0712(21)00515-1","volume":"17","author":"I Atroshi","year":"2001","unstructured":"Atroshi, I. & Rosberg, H. E. Epidemiology of amputations and severe injuries of the hand. Hand Clin. 17, 343\u2013350 (2001).","journal-title":"Hand Clin."},{"key":"966_CR6","doi-asserted-by":"publisher","first-page":"1031","DOI":"10.1053\/apmr.2001.24295","volume":"82","author":"WC Miller","year":"2001","unstructured":"Miller, W. C., Speechley, M. & Deathe, B. The prevalence and risk factors of falling and fear of falling among lower extremity amputees. Arch. Phys. Med. Rehabil. 82, 1031\u20131037 (2001).","journal-title":"Arch. Phys. Med. Rehabil."},{"key":"966_CR7","doi-asserted-by":"publisher","first-page":"142","DOI":"10.1016\/S0966-6362(02)00066-8","volume":"17","author":"L Nolan","year":"2003","unstructured":"Nolan, L. et al. Adjustments in gait symmetry with walking speed in trans-femoral and trans-tibial amputees. Gait Posture 17, 142\u2013151 (2003).","journal-title":"Gait Posture"},{"key":"966_CR8","doi-asserted-by":"publisher","first-page":"42","DOI":"10.2106\/00004623-197658010-00007","volume":"58","author":"RL Waters","year":"1976","unstructured":"Waters, R. L., Perry, J., Antonelli, D. & Hislop, H. Energy cost of walking of amputees: the influence of level of amputation. J. Bone Joint Surg. Am. 58, 42\u201346 (1976).","journal-title":"J. Bone Joint Surg. Am."},{"key":"966_CR9","doi-asserted-by":"publisher","first-page":"346","DOI":"10.1080\/17483100701714733","volume":"2","author":"E Biddiss","year":"2007","unstructured":"Biddiss, E., Beaton, D. & Chau, T. Consumer design priorities for upper limb prosthetics. Disabil. Rehabil. Assist. Technol. 2, 346\u2013357 (2007).","journal-title":"Disabil. Rehabil. Assist. Technol."},{"key":"966_CR10","doi-asserted-by":"publisher","first-page":"137","DOI":"10.1002\/ana.25384","volume":"85","author":"FM Petrini","year":"2019","unstructured":"Petrini, F. M. et al. Six-month assessment of a hand prosthesis with intraneural tactile feedback. Ann. Neurol. 85, 137\u2013154 (2019).","journal-title":"Ann. Neurol."},{"key":"966_CR11","first-page":"249","volume":"9","author":"GM Williamson","year":"1994","unstructured":"Williamson, G. M., Schulz, R., Bridges, M. W. & Behan, A. M. Social and psychological factors in adjustment to limb amputation. J. Soc. Behav. Pers. 9, 249\u2013268 (1994).","journal-title":"J. Soc. Behav. Pers."},{"key":"966_CR12","doi-asserted-by":"publisher","first-page":"556","DOI":"10.1038\/nrn3292","volume":"13","author":"O Blanke","year":"2012","unstructured":"Blanke, O. Multisensory brain mechanisms of bodily self-consciousness. Nat. Rev. Neurosci. 13, 556\u2013571 (2012).","journal-title":"Nat. Rev. Neurosci."},{"key":"966_CR13","doi-asserted-by":"publisher","first-page":"518","DOI":"10.1191\/0269215500cr345oa","volume":"14","author":"BW Heller","year":"2000","unstructured":"Heller, B. W., Datta, D. & Howitt, J. A pilot study comparing the cognitive demand of walking for transfemoral amputees using the intelligent prosthesis with that using conventionally damped knees. Clin. Rehabil. 14, 518\u2013522 (2000).","journal-title":"Clin. Rehabil."},{"key":"966_CR14","doi-asserted-by":"publisher","first-page":"0014","DOI":"10.1038\/s41551-016-0014","volume":"1","author":"TR Makin","year":"2017","unstructured":"Makin, T. R., de Vignemont, F. & Faisal, A. A. Neurocognitive barriers to the embodiment of technology. Nat. Biomed. Eng. 1, 0014 (2017).","journal-title":"Nat. Biomed. Eng."},{"key":"966_CR15","doi-asserted-by":"publisher","first-page":"873","DOI":"10.1038\/nrn1991","volume":"7","author":"H Flor","year":"2006","unstructured":"Flor, H., Nikolajsen, L. & Staehelin Jensen, T. Phantom limb pain: a case of maladaptive CNS plasticity? Nat. Rev. Neurosci. 7, 873\u2013881 (2006).","journal-title":"Nat. Rev. Neurosci."},{"key":"966_CR16","doi-asserted-by":"publisher","first-page":"224","DOI":"10.1016\/j.jphys.2014.09.003","volume":"60","author":"CE Roffman","year":"2014","unstructured":"Roffman, C. E., Buchanan, J. & Allison, G. T. Predictors of non-use of prostheses by people with lower limb amputation after discharge from rehabilitation: development and validation of clinical prediction rules. J. Physiother. 60, 224\u2013231 (2014).","journal-title":"J. Physiother."},{"key":"966_CR17","doi-asserted-by":"publisher","first-page":"1509","DOI":"10.1093\/brain\/110.6.1509","volume":"110","author":"HE Torebj\u00f6rk","year":"1987","unstructured":"Torebj\u00f6rk, H. E., Vallbo, A. A. B. & Ochoa, J. L. Intraneural microstimulation in man: its relation to specificity of tactile sensations. Brain 110, 1509\u20131529 (1987).","journal-title":"Brain"},{"key":"966_CR18","doi-asserted-by":"publisher","first-page":"1233","DOI":"10.1152\/jn.00848.2017","volume":"120","author":"ND Strzalkowski","year":"2018","unstructured":"Strzalkowski, N. D., Peters, R. M., Inglis, J. T. & Bent, L. R. Cutaneous afferent innervation of the human foot sole: what can we learn from single-unit recordings? J. Neurophysiol. 120, 1233\u20131246 (2018).","journal-title":"J. Neurophysiol."},{"key":"966_CR19","doi-asserted-by":"publisher","first-page":"11687","DOI":"10.1523\/JNEUROSCI.1486-07.2007","volume":"27","author":"MA Muniak","year":"2007","unstructured":"Muniak, M. A., Ray, S., Hsiao, S. S., Dammann, J. F. & Bensmaia, S. J. The neural coding of stimulus intensity: linking the population response of mechanoreceptive afferents with psychophysical behavior. J. Neurosci. 27, 11687\u201311699 (2007).","journal-title":"J. Neurosci."},{"key":"966_CR20","doi-asserted-by":"publisher","first-page":"17107","DOI":"10.1073\/pnas.1305509110","volume":"110","author":"AI Weber","year":"2013","unstructured":"Weber, A. I. et al. Spatial and temporal codes mediate the tactile perception of natural textures. Proc. Natl Acad. Sci. USA 110, 17107\u201317112 (2013).","journal-title":"Proc. Natl Acad. Sci. USA"},{"key":"966_CR21","doi-asserted-by":"publisher","first-page":"170","DOI":"10.1038\/nn1177","volume":"7","author":"RS Johansson","year":"2004","unstructured":"Johansson, R. S. & Birznieks, I. First spikes in ensembles of human tactile afferents code complex spatial fingertip events. Nat. Neurosci. 7, 170\u2013177 (2004).","journal-title":"Nat. Neurosci."},{"key":"966_CR22","doi-asserted-by":"publisher","first-page":"1651","DOI":"10.1152\/physrev.00048.2011","volume":"92","author":"U Proske","year":"2012","unstructured":"Proske, U. & Gandevia, S. C. The proprioceptive senses: their roles in signaling body shape, body position and movement, and muscle force. Physiol. Rev. 92, 1651\u20131697 (2012).","journal-title":"Physiol. Rev."},{"key":"966_CR23","doi-asserted-by":"publisher","first-page":"113","DOI":"10.1113\/jphysiol.1990.sp018247","volume":"429","author":"G Macefield","year":"1990","unstructured":"Macefield, G., Gandevia, S. C. & Burke, D. Perceptual responses to microstimulation of single afferents innervating joints, muscles and skin of the human hand. J. Physiol. 429, 113\u2013129 (1990).","journal-title":"J. Physiol."},{"key":"966_CR24","doi-asserted-by":"publisher","first-page":"1239","DOI":"10.1682\/JRRD.2011.05.0088","volume":"49","author":"D Rusaw","year":"2012","unstructured":"Rusaw, D., Hagberg, K., Nolan, L. & Ramstrand, N. Can vibratory feedback be used to improve postural stability in persons with transtibial limb loss? J. Rehabil. Res. Dev. 49, 1239\u20131254 (2012).","journal-title":"J. Rehabil. Res. Dev."},{"key":"966_CR25","doi-asserted-by":"publisher","first-page":"270","DOI":"10.3389\/fneur.2018.00270","volume":"9","author":"C Dietrich","year":"2018","unstructured":"Dietrich, C. et al. Leg prosthesis with somatosensory feedback reduces phantom limb pain and increases functionality. Front. Neurol. 9, 270 (2018).","journal-title":"Front. Neurol."},{"key":"966_CR26","doi-asserted-by":"publisher","first-page":"73","DOI":"10.1007\/BF02440956","volume":"17","author":"GF Shannon","year":"1979","unstructured":"Shannon, G. F. A myoelectrically-controlled prosthesis with sensory feedback. Med. Biol. Eng. Comput. 17, 73\u201380 (1979).","journal-title":"Med. Biol. Eng. Comput."},{"key":"966_CR27","first-page":"170","volume":"22","author":"RE Prior","year":"1976","unstructured":"Prior, R. E. Supplemental sensory feedback for the VA\/NU myoelectric hand background and preliminary designs. Bull. Prosthet. Res. 22, 170\u201391 (1976).","journal-title":"Bull. Prosthet. Res."},{"key":"966_CR28","doi-asserted-by":"crossref","unstructured":"Dosen, S., Schaeffer, M.-C. & Farina, D. Time-division multiplexing for myoelectric closed-loop control using electrotactile feedback. J. Neuroeng. Rehabil. 11, 138 (2014).","DOI":"10.1186\/1743-0003-11-138"},{"key":"966_CR29","doi-asserted-by":"publisher","first-page":"905","DOI":"10.1109\/10.8670","volume":"35","author":"GG Naples","year":"1988","unstructured":"Naples, G. G., Mortimer, J. T., Scheiner, A. & Sweeney, J. D. A spiral nerve cuff electrode for peripheral nerve stimulation. IEEE Trans. Biomed. Eng. 35, 905\u2013916 (1988).","journal-title":"IEEE Trans. Biomed. Eng."},{"key":"966_CR30","doi-asserted-by":"publisher","first-page":"294","DOI":"10.1109\/TNSRE.2002.806840","volume":"10","author":"DJ Tyler","year":"2002","unstructured":"Tyler, D. J. & Durand, D. M. Functionally selective peripheral nerve stimulation with a flat interface nerve electrode. IEEE Trans. Neural Syst. Rehabil. Eng. 10, 294\u2013303 (2002).","journal-title":"IEEE Trans. Neural Syst. Rehabil. Eng."},{"key":"966_CR31","doi-asserted-by":"publisher","first-page":"103","DOI":"10.1016\/S0165-0270(96)00111-2","volume":"70","author":"TG McNaughton","year":"1996","unstructured":"McNaughton, T. G. & Horch, K. W. Metallized polymer fibers as leadwires and intrafascicular microelectrodes. J. Neurosci. Methods 70, 103\u2013107 (1996).","journal-title":"J. Neurosci. Methods"},{"key":"966_CR32","doi-asserted-by":"crossref","unstructured":"Poppendieck, W. et al. A new generation of double-sided intramuscular electrodes for multi-channel recording and stimulation. In 2015 37th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) 7135\u20137138 (IEEE, 2015).","DOI":"10.1109\/EMBC.2015.7320037"},{"key":"966_CR33","doi-asserted-by":"publisher","first-page":"045003","DOI":"10.1088\/1741-2560\/10\/4\/045003","volume":"10","author":"HAC Wark","year":"2013","unstructured":"Wark, H. A. C. et al. A new high-density (25 electrodes\/mm2) penetrating microelectrode array for recording and stimulating sub-millimeter neuroanatomical structures. J. Neural Eng. 10, 045003 (2013).","journal-title":"J. Neural Eng."},{"key":"966_CR34","doi-asserted-by":"publisher","first-page":"62","DOI":"10.1016\/j.bios.2010.05.010","volume":"26","author":"T Boretius","year":"2010","unstructured":"Boretius, T. et al. A transverse intrafascicular multichannel electrode (TIME) to interface with the peripheral nerve. Biosens. Bioelectron. 26, 62\u201369 (2010).","journal-title":"Biosens. Bioelectron."},{"key":"966_CR35","doi-asserted-by":"publisher","first-page":"18","DOI":"10.1002\/polb.22169","volume":"49","author":"C Hassler","year":"2011","unstructured":"Hassler, C., Boretius, T. & Stieglitz, T. Polymers for neural implants. J. Polym. Sci. B 49, 18\u201333 (2011).","journal-title":"J. Polym. Sci. B"},{"key":"966_CR36","doi-asserted-by":"publisher","first-page":"590","DOI":"10.1557\/mrs.2012.117","volume":"37","author":"J Ordonez","year":"2012","unstructured":"Ordonez, J., Schuettler, M., Boehler, C., Boretius, T. & Stieglitz, T. Thin films and microelectrode arrays for neuroprosthetics. MRS Bull. 37, 590\u2013598 (2012).","journal-title":"MRS Bull."},{"key":"966_CR37","doi-asserted-by":"publisher","first-page":"1732","DOI":"10.1056\/NEJMoa1917537","volume":"382","author":"M Ortiz-Catalan","year":"2020","unstructured":"Ortiz-Catalan, M., Mastinu, E., Sassu, P., Aszmann, O. & Br\u00e5nemark, R. Self-contained neuromusculoskeletal arm prostheses. N. Engl. J. Med. 382, 1732\u20131738 (2020).","journal-title":"N. Engl. J. Med."},{"key":"966_CR38","doi-asserted-by":"publisher","first-page":"192","DOI":"10.1002\/mus.21652","volume":"42","author":"J Badia","year":"2010","unstructured":"Badia, J., Pascual-Font, A., Viv\u00f3, M., Udina, E. & Navarro, X. Topographical distribution of motor fascicles in the sciatic-tibial nerve of the rat. Muscle Nerve 42, 192\u2013201 (2010).","journal-title":"Muscle Nerve"},{"key":"966_CR39","doi-asserted-by":"publisher","first-page":"036022","DOI":"10.1088\/1741-2552\/aa6632","volume":"14","author":"MJ Freeberg","year":"2017","unstructured":"Freeberg, M. J., Stone, M. A., Triolo, R. J. & Tyler, D. J. The design of and chronic tissue response to a composite nerve electrode with patterned stiffness. J. Neural Eng. 14, 036022 (2017).","journal-title":"J. Neural Eng."},{"key":"966_CR40","doi-asserted-by":"publisher","first-page":"9","DOI":"10.1016\/S0165-0270(03)00231-0","volume":"131","author":"SM Lawrence","year":"2003","unstructured":"Lawrence, S. M., Dhillon, G. S. & Horch, K. W. Fabrication and characteristics of an implantable, polymer-based, intrafascicular electrode. J. Neurosci. Methods 131, 9\u201326 (2003).","journal-title":"J. Neurosci. Methods"},{"key":"966_CR41","doi-asserted-by":"publisher","unstructured":"Overstreet, C. K., Cheng, J. & Keefer, E. Fascicle specific targeting for selective peripheral nerve stimulation. J. Neural Eng. https:\/\/doi.org\/10.1088\/1741-2552\/ab4370 (2019).","DOI":"10.1088\/1741-2552\/ab4370"},{"key":"966_CR42","doi-asserted-by":"publisher","first-page":"114","DOI":"10.1016\/j.biomaterials.2017.01.014","volume":"122","author":"S Wurth","year":"2017","unstructured":"Wurth, S. et al. Long-term usability and bio-integration of polyimide-based intra-neural stimulating electrodes. Biomaterials 122, 114\u2013129 (2017).","journal-title":"Biomaterials"},{"key":"966_CR43","doi-asserted-by":"publisher","first-page":"171","DOI":"10.1016\/j.jneumeth.2004.10.020","volume":"141","author":"DR Merrill","year":"2005","unstructured":"Merrill, D. R., Bikson, M. & Jefferys, J. G. Electrical stimulation of excitable tissue: design of efficacious and safe protocols. J. Neurosci. Methods 141, 171\u2013198 (2005).","journal-title":"J. Neurosci. Methods"},{"key":"966_CR44","doi-asserted-by":"publisher","first-page":"275","DOI":"10.1146\/annurev.bioeng.10.061807.160518","volume":"10","author":"SF Cogan","year":"2008","unstructured":"Cogan, S. F. Neural stimulation and recording electrodes. Annu. Rev. Biomed. Eng. 10, 275\u2013309 (2008).","journal-title":"Annu. Rev. Biomed. Eng."},{"key":"966_CR45","doi-asserted-by":"publisher","first-page":"777","DOI":"10.1016\/j.clinph.2010.01.001","volume":"121","author":"PM Rossini","year":"2010","unstructured":"Rossini, P. M. et al. Double nerve intraneural interface implant on a human amputee for robotic hand control. Clin. Neurophysiol. 121, 777\u2013783 (2010).","journal-title":"Clin. Neurophysiol."},{"key":"966_CR46","doi-asserted-by":"crossref","unstructured":"Boretius, T. et al. A transverse intrafascicular multichannel electrode (TIME) to treat phantom limb pain\u2014towards human clinical trials. In 2012 4th IEEE RAS & EMBS International Conference on Biomedical Robotics and Biomechatronics (BioRob) 282\u2013287 (IEEE, 2012).","DOI":"10.1109\/BioRob.2012.6290787"},{"key":"966_CR47","doi-asserted-by":"publisher","first-page":"1118","DOI":"10.1109\/10.61038","volume":"37","author":"TL Rose","year":"1990","unstructured":"Rose, T. L. & Robblee, L. S. Electrical stimulation with Pt electrodes. VIII. Electrochemically safe charge injection limits with 0.2 ms pulses (neuronal application). IEEE Trans. Biomed. Eng. 37, 1118\u20131120 (1990).","journal-title":"IEEE Trans. Biomed. Eng."},{"key":"966_CR48","doi-asserted-by":"publisher","first-page":"353","DOI":"10.1002\/jbm.b.31223","volume":"89","author":"SF Cogan","year":"2009","unstructured":"Cogan, S. F. et al. Sputtered iridium oxide films for neural stimulation electrodes. J. Biomed. Mater. Res. B 89, 353\u2013361 (2009).","journal-title":"J. Biomed. Mater. Res. B"},{"key":"966_CR49","doi-asserted-by":"publisher","first-page":"215","DOI":"10.1002\/(SICI)1097-4636(200005)50:2<215::AID-JBM17>3.0.CO;2-A","volume":"50","author":"WM Grill","year":"2000","unstructured":"Grill, W. M. & Mortimer, J. T. Neural and connective tissue response to long-term implantation of multiple contact nerve cuff electrodes. J. Biomed. Mater. Res. 50, 215\u2013226 (2000).","journal-title":"J. Biomed. Mater. Res."},{"key":"966_CR50","doi-asserted-by":"publisher","first-page":"428","DOI":"10.1109\/TNSRE.2009.2032603","volume":"17","author":"KH Polasek","year":"2009","unstructured":"Polasek, K. H., Hoyen, H. A., Keith, M. W., Kirsch, R. F. & Tyler, D. J. Stimulation stability and selectivity of chronically implanted multicontact nerve cuff electrodes in the human upper extremity. IEEE Trans. Neural Syst. Rehabil. Eng. 17, 428\u2013437 (2009).","journal-title":"IEEE Trans. Neural Syst. Rehabil. Eng."},{"key":"966_CR51","doi-asserted-by":"publisher","first-page":"633","DOI":"10.1114\/1.1569263","volume":"31","author":"DJ Tyler","year":"2003","unstructured":"Tyler, D. J. & Durand, D. M. Chronic response of the rat sciatic nerve to the flat interface nerve electrode. Ann. Biomed. Eng. 31, 633\u2013642 (2003).","journal-title":"Ann. Biomed. Eng."},{"key":"966_CR52","doi-asserted-by":"publisher","first-page":"102","DOI":"10.1088\/1741-2560\/3\/2\/004","volume":"3","author":"DK Leventhal","year":"2006","unstructured":"Leventhal, D. K., Cohen, M. & Durand, D. M. Chronic histological effects of the flat interface nerve electrode. J. Neural Eng. 3, 102 (2006).","journal-title":"J. Neural Eng."},{"key":"966_CR53","doi-asserted-by":"publisher","first-page":"257ra138","DOI":"10.1126\/scitranslmed.3008669","volume":"6","author":"DW Tan","year":"2014","unstructured":"Tan, D. W. et al. A neural interface provides long-term stable natural touch perception. Sci. Transl. Med. 6, 257ra138 (2014).","journal-title":"Sci. Transl. Med."},{"key":"966_CR54","doi-asserted-by":"publisher","first-page":"281","DOI":"10.1109\/TBME.2006.886617","volume":"54","author":"N Lago","year":"2007","unstructured":"Lago, N., Yoshida, K., Koch, K. P. & Navarro, X. Assessment of biocompatibility of chronically implanted polyimide and platinum intrafascicular electrodes. IEEE Trans. Biomed. Eng. 54, 281\u2013290 (2007).","journal-title":"IEEE Trans. Biomed. Eng."},{"key":"966_CR55","doi-asserted-by":"publisher","first-page":"2324","DOI":"10.1109\/TBME.2011.2153850","volume":"58","author":"J Badia","year":"2011","unstructured":"Badia, J. et al. Biocompatibility of chronically implanted transverse intrafascicular multichannel electrode (TIME) in the rat sciatic nerve. IEEE Trans. Biomed. Eng. 58, 2324\u20132332 (2011).","journal-title":"IEEE Trans. Biomed. Eng."},{"key":"966_CR56","doi-asserted-by":"publisher","first-page":"146","DOI":"10.1109\/TBME.2003.820321","volume":"51","author":"A Branner","year":"2004","unstructured":"Branner, A., Stein, R. B., Fernandez, E., Aoyagi, Y. & Normann, R. A. Long-term stimulation and recording with a penetrating microelectrode array in cat sciatic nerve. IEEE Trans. Biomed. Eng. 51, 146\u2013157 (2004).","journal-title":"IEEE Trans. Biomed. Eng."},{"key":"966_CR57","doi-asserted-by":"publisher","first-page":"235","DOI":"10.1016\/j.biomaterials.2015.11.012","volume":"77","author":"MB Christensen","year":"2016","unstructured":"Christensen, M. B., Wark, H. A. & Hutchinson, D. T. A histological analysis of human median and ulnar nerves following implantation of Utah slanted electrode arrays. Biomaterials 77, 235\u2013242 (2016).","journal-title":"Biomaterials"},{"key":"966_CR58","doi-asserted-by":"publisher","first-page":"68","DOI":"10.1002\/ana.410360114","volume":"36","author":"W Schady","year":"1994","unstructured":"Schady, W., Braune, S., Watson, S., Torebj\u00f6rk, H. E. & Schmidt, R. Responsiveness of the somatosensory system after nerve injury and amputation in the human hand. Ann. Neurol. 36, 68\u201375 (1994).","journal-title":"Ann. Neurol."},{"key":"966_CR59","unstructured":"Clippinger, F. W., Avery, R. & Titus, B. R. A sensory feedback system for an upper-limb amputation prosthesis. Bull. Prosthet. Res. 10, 247\u2013258 (1974)."},{"key":"966_CR60","doi-asserted-by":"crossref","unstructured":"Clippinger, F. W., Seaber, A. V., McElhaney, J. H., Harrelson, J. M. & Maxwell, G. M. Afferent sensory feedback for lower extremity prosthesis. Clin. Orthop. Relat. Res. 169, 202\u2013206 (1982).","DOI":"10.1097\/00003086-198209000-00031"},{"key":"966_CR61","doi-asserted-by":"crossref","unstructured":"Dhillon, G. S., Lawrence, S. M., Hutchinson, D. T. & Horch, K. W. Residual function in peripheral nerve stumps of amputees: implications for neural control of artificial limbs. J. Hand Surg. Am. 29, 605\u2013615 (2004).","DOI":"10.1016\/j.jhsa.2004.02.006"},{"key":"966_CR62","doi-asserted-by":"publisher","first-page":"468","DOI":"10.1109\/TNSRE.2005.856072","volume":"13","author":"GS Dhillon","year":"2005","unstructured":"Dhillon, G. S. & Horch, K. W. Direct neural sensory feedback and control of a prosthetic arm. IEEE Trans. Neural Syst. Rehabil. Eng. 13, 468\u2013472 (2005).","journal-title":"IEEE Trans. Neural Syst. Rehabil. Eng."},{"key":"966_CR63","doi-asserted-by":"publisher","DOI":"10.1038\/s41598-018-34910-w","volume":"8","author":"G Valle","year":"2018","unstructured":"Valle, G. et al. Comparison of linear frequency and amplitude modulation for intraneural sensory feedback in bidirectional hand prostheses. Sci. Rep. 8, 16666 (2018).","journal-title":"Sci. Rep."},{"key":"966_CR64","doi-asserted-by":"publisher","first-page":"222ra19","DOI":"10.1126\/scitranslmed.3006820","volume":"6","author":"S Raspopovic","year":"2014","unstructured":"Raspopovic, S. et al. Restoring natural sensory feedback in real-time bidirectional hand prostheses. Sci. Transl. Med. 6, 222ra19 (2014).","journal-title":"Sci. Transl. Med."},{"key":"966_CR65","doi-asserted-by":"publisher","unstructured":"Valle, G. et al. Biomimetic intraneural sensory feedback enhances sensation naturalness, tactile sensitivity, and manual dexterity in a bidirectional prosthesis. Neuron https:\/\/doi.org\/10.1016\/j.neuron.2018.08.033 (2018).","DOI":"10.1016\/j.neuron.2018.08.033"},{"key":"966_CR66","doi-asserted-by":"publisher","first-page":"eaax2352","DOI":"10.1126\/scirobotics.aax2352","volume":"4","author":"JA George","year":"2019","unstructured":"George, J. A. et al. Biomimetic sensory feedback through peripheral nerve stimulation improves dexterous use of a bionic hand. Sci. Robot. 4, eaax2352 (2019).","journal-title":"Sci. Robot."},{"key":"966_CR67","doi-asserted-by":"publisher","first-page":"483","DOI":"10.1109\/TNSRE.2011.2162635","volume":"19","author":"K Horch","year":"2011","unstructured":"Horch, K., Meek, S., Taylor, T. G. & Hutchinson, D. T. Object discrimination with an artificial hand using electrical stimulation of peripheral tactile and proprioceptive pathways with intrafascicular electrodes. IEEE Trans. Neural Syst. Rehabil. Eng. 19, 483\u2013489 (2011).","journal-title":"IEEE Trans. Neural Syst. Rehabil. Eng."},{"key":"966_CR68","doi-asserted-by":"publisher","first-page":"eaau9924","DOI":"10.1126\/scirobotics.aau9924","volume":"4","author":"L Zollo","year":"2019","unstructured":"Zollo, L. et al. Restoring tactile sensations via neural interfaces for real-time force-and-slippage closed-loop control of bionic hands. Sci. Robot. 4, eaau9924 (2019).","journal-title":"Sci. Robot."},{"key":"966_CR69","doi-asserted-by":"publisher","first-page":"257re6","DOI":"10.1126\/scitranslmed.3008933","volume":"6","author":"M Ortiz-Catalan","year":"2014","unstructured":"Ortiz-Catalan, M., Hakansson, B. & Branemark, R. An osseointegrated human-machine gateway for long-term sensory feedback and motor control of artificial limbs. Sci. Transl. Med. 6, 257re6 (2014).","journal-title":"Sci. Transl. Med."},{"key":"966_CR70","doi-asserted-by":"crossref","unstructured":"Oddo, C. M. et al. Intraneural stimulation elicits discrimination of textural features by artificial fingertip in intact and amputee humans. eLife 5, e09148 (2016).","DOI":"10.7554\/eLife.09148"},{"key":"966_CR71","doi-asserted-by":"publisher","first-page":"036001","DOI":"10.1088\/1741-2560\/13\/3\/036001","volume":"13","author":"TS Davis","year":"2016","unstructured":"Davis, T. S. et al. Restoring motor control and sensory feedback in people with upper extremity amputations using arrays of 96 microelectrodes implanted in the median and ulnar nerves. J. Neural Eng. 13, 036001 (2016).","journal-title":"J. Neural Eng."},{"key":"966_CR72","doi-asserted-by":"publisher","first-page":"121","DOI":"10.1186\/s12984-017-0320-4","volume":"14","author":"S Wendelken","year":"2017","unstructured":"Wendelken, S. et al. Restoration of motor control and proprioceptive and cutaneous sensation in humans with prior upper-limb amputation via multiple Utah slanted electrode arrays (USEAs) implanted in residual peripheral arm nerves. J. Neuroeng. Rehabil. 14, 121 (2017).","journal-title":"J. Neuroeng. Rehabil."},{"key":"966_CR73","doi-asserted-by":"publisher","first-page":"833","DOI":"10.1136\/jnnp-2018-318570","volume":"90","author":"G Rognini","year":"2019","unstructured":"Rognini, G. et al. Multisensory bionic limb to achieve prosthesis embodiment and reduce distorted phantom limb perceptions. J. Neurol. Neurosurg. Psychiatry 90, 833\u2013836 (2019).","journal-title":"J. Neurol. Neurosurg. Psychiatry"},{"key":"966_CR74","doi-asserted-by":"crossref","unstructured":"Segil, J. L., Cuberovic, I., Graczyk, E. L., Weir, R. F. ff. & Tyler, D. Combination of simultaneous artificial sensory percepts to identify prosthetic hand postures: a case study. Sci. Rep. 10, 6576 (2020).","DOI":"10.1038\/s41598-020-62970-4"},{"key":"966_CR75","doi-asserted-by":"publisher","DOI":"10.1038\/s41598-018-26952-x","volume":"8","author":"EL Graczyk","year":"2018","unstructured":"Graczyk, E. L., Resnik, L., Schiefer, M. A., Schmitt, M. S. & Tyler, D. J. Home use of a neural-connected sensory prosthesis provides the functional and psychosocial experience of having a hand again. Sci. Rep. 8, 9866 (2018).","journal-title":"Sci. Rep."},{"key":"966_CR76","doi-asserted-by":"publisher","first-page":"026002","DOI":"10.1088\/1741-2560\/12\/2\/026002","volume":"12","author":"DW Tan","year":"2015","unstructured":"Tan, D. W., Schiefer, M. A., Keith, M. W., Anderson, J. R. & Tyler, D. J. Stability and selectivity of a chronic, multi-contact cuff electrode for sensory stimulation in human amputees. J. Neural Eng. 12, 026002 (2015).","journal-title":"J. Neural Eng."},{"key":"966_CR77","doi-asserted-by":"publisher","first-page":"619","DOI":"10.1001\/jama.2009.116","volume":"301","author":"TA Kuiken","year":"2009","unstructured":"Kuiken, T. A. et al. Targeted muscle reinnervation for real-time myoelectric control of multifunction artificial arms. JAMA 301, 619\u2013628 (2009).","journal-title":"JAMA"},{"key":"966_CR78","doi-asserted-by":"publisher","first-page":"371","DOI":"10.1016\/S0140-6736(07)60193-7","volume":"369","author":"TA Kuiken","year":"2007","unstructured":"Kuiken, T. A. et al. Targeted reinnervation for enhanced prosthetic arm function in a woman with a proximal amputation: a case study. Lancet 369, 371\u2013380 (2007).","journal-title":"Lancet"},{"key":"966_CR79","doi-asserted-by":"publisher","first-page":"20061","DOI":"10.1073\/pnas.0706525104","volume":"104","author":"TA Kuiken","year":"2007","unstructured":"Kuiken, T. A., Marasco, P. D., Lock, B. A., Harden, R. N. & Dewald, J. P. A. Redirection of cutaneous sensation from the hand to the chest skin of human amputees with targeted reinnervation. Proc. Natl Acad. Sci. USA 104, 20061\u201320066 (2007).","journal-title":"Proc. Natl Acad. Sci. USA"},{"key":"966_CR80","doi-asserted-by":"publisher","first-page":"120","DOI":"10.3389\/fnins.2020.00120","volume":"14","author":"JS Schofield","year":"2020","unstructured":"Schofield, J. S., Shell, C. E., Beckler, D. T., Thumser, Z. C. & Marasco, P. D. Long-term home-use of sensory-motor-integrated bidirectional bionic prosthetic arms promotes functional, perceptual, and cognitive changes. Front Neurosci. 14, 120 (2020).","journal-title":"Front Neurosci."},{"key":"966_CR81","doi-asserted-by":"publisher","unstructured":"Osborn, L., Betthauser, J., Kaliki, R. & Thakor, N. Live demonstration: targeted transcutaneous electrical nerve stimulation for phantom limb sensory feedback. In 2017 IEEE Biomedical Circuits and Systems Conference (BioCAS) 1-1 (IEEE, 2017); https:\/\/doi.org\/10.1109\/BIOCAS.2017.8325101","DOI":"10.1109\/BIOCAS.2017.8325101"},{"key":"966_CR82","doi-asserted-by":"publisher","first-page":"056002","DOI":"10.1088\/1741-2552\/aac964","volume":"15","author":"H Charkhkar","year":"2018","unstructured":"Charkhkar, H. et al. High-density peripheral nerve cuffs restore natural sensation to individuals with lower-limb amputations. J. Neural Eng. 15, 056002 (2018).","journal-title":"J. Neural Eng."},{"key":"966_CR83","doi-asserted-by":"publisher","first-page":"1356","DOI":"10.1038\/s41591-019-0567-3","volume":"25","author":"FM Petrini","year":"2019","unstructured":"Petrini, F. M. et al. Sensory feedback restoration in leg amputees improves walking speed, metabolic cost and phantom pain. Nat. Med. 25, 1356\u20131363 (2019).","journal-title":"Nat. Med."},{"key":"966_CR84","doi-asserted-by":"publisher","first-page":"eaav8939","DOI":"10.1126\/scitranslmed.aav8939","volume":"11","author":"FM Petrini","year":"2019","unstructured":"Petrini, F. M. et al. Enhancing functional abilities and cognitive integration of the lower limb prosthesis. Sci. Transl. Med. 11, eaav8939 (2019).","journal-title":"Sci. Transl. Med."},{"key":"966_CR85","doi-asserted-by":"publisher","first-page":"58","DOI":"10.1186\/s12984-018-0400-0","volume":"15","author":"BF Mundell","year":"2018","unstructured":"Mundell, B. F. et al. The risk of major cardiovascular events for adults with transfemoral amputation. J. Neuroeng. Rehabil. 15, 58 (2018).","journal-title":"J. Neuroeng. Rehabil."},{"key":"966_CR86","doi-asserted-by":"publisher","first-page":"eaap8373","DOI":"10.1126\/scitranslmed.aap8373","volume":"10","author":"TR Clites","year":"2018","unstructured":"Clites, T. R. et al. Proprioception from a neurally controlled lower-extremity prosthesis. Sci. Transl. Med. 10, eaap8373 (2018).","journal-title":"Sci. Transl. Med."},{"key":"966_CR87","doi-asserted-by":"publisher","first-page":"345","DOI":"10.1038\/nrn2621","volume":"10","author":"RS Johansson","year":"2009","unstructured":"Johansson, R. S. & Flanagan, J. R. Coding and use of tactile signals from the fingertips in object manipulation tasks. Nat. Rev. Neurosci. 10, 345\u2013359 (2009).","journal-title":"Nat. Rev. Neurosci."},{"key":"966_CR88","doi-asserted-by":"publisher","first-page":"eaao6990","DOI":"10.1126\/scitranslmed.aao6990","volume":"10","author":"PD Marasco","year":"2018","unstructured":"Marasco, P. D. et al. Illusory movement perception improves motor control for prosthetic hands. Sci. Transl. Med. 10, eaao6990 (2018).","journal-title":"Sci. Transl. Med."},{"key":"966_CR89","doi-asserted-by":"publisher","first-page":"965","DOI":"10.1093\/brain\/108.4.965","volume":"108","author":"SC Gandevia","year":"1985","unstructured":"Gandevia, S. C. Illusory movements produced by electrical stimulation of low-threshold muscle afferents from the hand. Brain 108, 965\u2013981 (1985).","journal-title":"Brain"},{"key":"966_CR90","doi-asserted-by":"publisher","first-page":"367","DOI":"10.1016\/S0361-9230(96)00324-3","volume":"42","author":"R Ekedahl","year":"1997","unstructured":"Ekedahl, R., Frank, O. & Hallin, R. G. Peripheral afferents with common function cluster in the median nerve and somatotopically innervate the human palm. Brain Res. Bull. 42, 367\u2013376 (1997).","journal-title":"Brain Res. Bull."},{"key":"966_CR91","doi-asserted-by":"publisher","first-page":"625","DOI":"10.1136\/jnnp.38.7.625","volume":"38","author":"KE Hagbarth","year":"1975","unstructured":"Hagbarth, K. E., Wallen, G. & L\u00f6fstedt, L. Muscle spindle activity in man during voluntary fast alternating movements. J. Neurol. Neurosurg. Psychiatry 38, 625\u2013635 (1975).","journal-title":"J. Neurol. Neurosurg. Psychiatry"},{"key":"966_CR92","doi-asserted-by":"publisher","first-page":"525","DOI":"10.1002\/mus.10454","volume":"28","author":"JD Stewart","year":"2003","unstructured":"Stewart, J. D. Peripheral nerve fascicles: anatomy and clinical relevance. Muscle Nerve 28, 525\u2013541 (2003).","journal-title":"Muscle Nerve"},{"key":"966_CR93","doi-asserted-by":"publisher","first-page":"eaau8892","DOI":"10.1126\/scirobotics.aau8892","volume":"4","author":"E D\u2019Anna","year":"2019","unstructured":"D\u2019Anna, E. et al. A closed-loop hand prosthesis with simultaneous intraneural tactile and position feedback. Sci. Robot. 4, eaau8892 (2019).","journal-title":"Sci. Robot."},{"key":"966_CR94","doi-asserted-by":"crossref","unstructured":"de la Oliva, N., Mueller, M., Stieglitz, T., Navarro, X. & del Valle, J. On the use of parylene C polymer as substrate for peripheral nerve electrodes. Sci. Rep. 8, 5965 (2018).","DOI":"10.1038\/s41598-018-24502-z"},{"key":"966_CR95","doi-asserted-by":"crossref","unstructured":"Preatoni, G., Valle, G., Petrini, F. M. & Raspopovic, S. Lightening the perceived prosthesis weight with neural embodiment promoted by sensory feedback. Curr. Biol. 31, 1065\u20131071 (2021).","DOI":"10.1016\/j.cub.2020.11.069"},{"key":"966_CR96","doi-asserted-by":"publisher","first-page":"2287","DOI":"10.1002\/adfm.201404365","volume":"25","author":"AP Gerratt","year":"2015","unstructured":"Gerratt, A. P., Michaud, H. O. & Lacour, S. P. Elastomeric electronic skin for prosthetic tactile sensation. Adv. Funct. Mater. 25, 2287\u20132295 (2015).","journal-title":"Adv. Funct. Mater."},{"key":"966_CR97","doi-asserted-by":"publisher","DOI":"10.1038\/s41467-017-02685-9","volume":"9","author":"Q Hua","year":"2018","unstructured":"Hua, Q. et al. Skin-inspired highly stretchable and conformable matrix networks for multifunctional sensing. Nat. Commun. 9, 244 (2018).","journal-title":"Nat. Commun."},{"key":"966_CR98","doi-asserted-by":"publisher","first-page":"eaax2198","DOI":"10.1126\/scirobotics.aax2198","volume":"4","author":"WW Lee","year":"2019","unstructured":"Lee, W. W. et al. A neuro-inspired artificial peripheral nervous system for scalable electronic skins. Sci. Robot. 4, eaax2198 (2019).","journal-title":"Sci. Robot."},{"key":"966_CR99","doi-asserted-by":"publisher","first-page":"344","DOI":"10.1016\/j.neuropsychologia.2015.06.010","volume":"79","author":"HP Saal","year":"2015","unstructured":"Saal, H. P. & Bensmaia, S. J. Biomimetic approaches to bionic touch through a peripheral nerve interface. Neuropsychologia 79, 344\u2013353 (2015).","journal-title":"Neuropsychologia"},{"key":"966_CR100","doi-asserted-by":"publisher","first-page":"013002","DOI":"10.1088\/1741-2552\/aa966a","volume":"15","author":"LH Kim","year":"2018","unstructured":"Kim, L. H., McLeod, R. S. & Kiss, Z. H. A new psychometric questionnaire for reporting of somatosensory percepts. J. Neural Eng. 15, 013002 (2018).","journal-title":"J. Neural Eng."},{"key":"966_CR101","doi-asserted-by":"publisher","first-page":"417","DOI":"10.1682\/JRRD.2008.01.0007","volume":"46","author":"BJ Hafner","year":"2009","unstructured":"Hafner, B. J. & Smith, D. G. Differences in function and safety between Medicare functional classification level-2 and-3 transfemoral amputees and influence of prosthetic knee joint control. J. Rehabil. Res. Dev. 46, 417\u2013433 (2009).","journal-title":"J. Rehabil. Res. Dev."},{"key":"966_CR102","doi-asserted-by":"publisher","first-page":"229","DOI":"10.1111\/j.1085-9489.2005.10303.x","volume":"10","author":"X Navarro","year":"2005","unstructured":"Navarro, X. et al. A critical review of interfaces with the peripheral nervous system for the control of neuroprostheses and hybrid bionic systems. J. Peripher. Nerv. Syst. 10, 229\u2013258 (2005).","journal-title":"J. Peripher. Nerv. Syst."},{"key":"966_CR103","doi-asserted-by":"publisher","first-page":"633","DOI":"10.1113\/jphysiol.1983.sp014873","volume":"342","author":"J Ochoa","year":"1983","unstructured":"Ochoa, J. & Torebj\u00f6rk, E. Sensations evoked by intraneural microstimulation of single mechanoreceptor units innervating the human hand. J. Physiol. 342, 633\u2013654 (1983).","journal-title":"J. Physiol."},{"key":"966_CR104","doi-asserted-by":"crossref","unstructured":"Zelechowski, M., Valle, G. & Raspopovic, S. A computational model to design neural interfaces for lower-limb sensory neuroprostheses. J. Neuroeng. Rehabil. 17, 24 (2020).","DOI":"10.1186\/s12984-020-00657-7"},{"key":"966_CR105","doi-asserted-by":"publisher","first-page":"290","DOI":"10.1126\/science.abb1073","volume":"370","author":"S Raspopovic","year":"2020","unstructured":"Raspopovic, S. Advancing limb neural prostheses. Science 370, 290\u2013291 (2020).","journal-title":"Science"},{"key":"966_CR106","doi-asserted-by":"publisher","first-page":"1161","DOI":"10.1038\/nm.2228","volume":"16","author":"ME Llewellyn","year":"2010","unstructured":"Llewellyn, M. E., Thompson, K. R., Deisseroth, K. & Delp, S. L. Orderly recruitment of motor units under optical control in vivo. Nat. Med. 16, 1161\u20131165 (2010).","journal-title":"Nat. Med."},{"key":"966_CR107","doi-asserted-by":"publisher","first-page":"379","DOI":"10.1038\/nature21004","volume":"540","author":"T Someya","year":"2016","unstructured":"Someya, T., Bao, Z. & Malliaras, G. G. The rise of plastic bioelectronics. Nature 540, 379\u2013385 (2016).","journal-title":"Nature"},{"key":"966_CR108","doi-asserted-by":"publisher","first-page":"207","DOI":"10.1038\/s41551-020-0518-9","volume":"4","author":"DK Piech","year":"2020","unstructured":"Piech, D. K. et al. A wireless millimetre-scale implantable neural stimulator with ultrasonically powered bidirectional communication. Nat. Biomed. Eng. 4, 207\u2013222 (2020).","journal-title":"Nat. Biomed. Eng."},{"key":"966_CR109","doi-asserted-by":"publisher","first-page":"618","DOI":"10.1016\/j.neuron.2013.07.051","volume":"79","author":"VE Abraira","year":"2013","unstructured":"Abraira, V. E. & Ginty, D. D. The sensory neurons of touch. Neuron 79, 618\u2013639 (2013).","journal-title":"Neuron"},{"key":"966_CR110","doi-asserted-by":"crossref","unstructured":"Johansson, R. S. & Flanagan, J. R. in The Senses: A Comprehensive Reference 67\u201386 (Academic Press, 2008).","DOI":"10.1016\/B978-012370880-9.00346-7"},{"key":"966_CR111","doi-asserted-by":"publisher","first-page":"283","DOI":"10.1113\/jphysiol.1979.sp012619","volume":"286","author":"RS Johansson","year":"1979","unstructured":"Johansson, R. S. & Vallbo, A. B. Tactile sensibility in the human hand: relative and absolute densities of four types of mechanoreceptive units in glabrous skin. J. Physiol. 286, 283\u2013300 (1979).","journal-title":"J. Physiol."},{"key":"966_CR112","doi-asserted-by":"crossref","unstructured":"Johansson, R. S. & Vallbo, \u00c5. B. Tactile sensory coding in the glabrous skin of the human hand. Trends Neurosci. 6, 27\u201332 (1983).","DOI":"10.1016\/0166-2236(83)90011-5"},{"key":"966_CR113","doi-asserted-by":"publisher","first-page":"43","DOI":"10.1186\/s12984-020-00667-5","volume":"17","author":"KA Yildiz","year":"2020","unstructured":"Yildiz, K. A., Shin, A. Y. & Kaufman, K. R. Interfaces with the peripheral nervous system for the control of a neuroprosthetic limb: a review. J. Neuroeng. Rehabil. 17, 43 (2020).","journal-title":"J. Neuroeng. Rehabil."},{"key":"966_CR114","doi-asserted-by":"crossref","unstructured":"Benvenuto, A. et al. Intrafascicular thin-film multichannel electrodes for sensory feedback: evidences on a human amputee. In 2010 Annual International Conference of the IEEE Engineering in Medicine and Biology 1800\u20131803 (IEEE, 2010).","DOI":"10.1109\/IEMBS.2010.5626401"},{"key":"966_CR115","doi-asserted-by":"publisher","first-page":"15007","DOI":"10.1088\/1748-6041\/5\/1\/015007","volume":"5","author":"S Negi","year":"2010","unstructured":"Negi, S., Bhandari, R., Rieth, L. & Solzbacher, F. In vitro comparison of sputtered iridium oxide and platinum-coated neural implantable microelectrode arrays. Biomed. Mater. 5, 15007 (2010).","journal-title":"Biomed. Mater."},{"key":"966_CR116","unstructured":"Badia, J. et al. in Direct Nerve Stimulation for Induction of Sensation and Treatment of Phantom Limb Pain 155\u2013169 (River Publishers, 2019)."},{"key":"966_CR117","doi-asserted-by":"publisher","first-page":"046002","DOI":"10.1088\/1741-2552\/aab790","volume":"15","author":"EL Graczyk","year":"2018","unstructured":"Graczyk, E. L., Delhaye, B. P., Schiefer, M. A., Bensmaia, S. J. & Tyler, D. J. Sensory adaptation to electrical stimulation of the somatosensory nerves. J. Neural Eng. 15, 046002 (2018).","journal-title":"J. Neural Eng."},{"key":"966_CR118","doi-asserted-by":"crossref","unstructured":"Strauss, I. et al. Characterization of multi-channel intraneural stimulation in transradial amputees. Sci. Rep. 9, 9258 (2019).","DOI":"10.1038\/s41598-019-55591-z"},{"key":"966_CR119","doi-asserted-by":"publisher","first-page":"876","DOI":"10.1109\/TNSRE.2019.2908817","volume":"27","author":"DT Kluger","year":"2019","unstructured":"Kluger, D. T. et al. Virtual reality provides an effective platform for functional evaluations of closed-loop neuromyoelectric control. IEEE Trans. Neural Syst. Rehabil. Eng. 27, 876\u2013886 (2019).","journal-title":"IEEE Trans. Neural Syst. Rehabil. Eng."}],"container-title":["Nature Materials"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.nature.com\/articles\/s41563-021-00966-9.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.nature.com\/articles\/s41563-021-00966-9","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.nature.com\/articles\/s41563-021-00966-9.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,1,31]],"date-time":"2023-01-31T01:22:51Z","timestamp":1675128171000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.nature.com\/articles\/s41563-021-00966-9"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2021,4,15]]},"references-count":119,"journal-issue":{"issue":"7","published-print":{"date-parts":[[2021,7]]}},"alternative-id":["966"],"URL":"https:\/\/doi.org\/10.1038\/s41563-021-00966-9","relation":{},"ISSN":["1476-1122","1476-4660"],"issn-type":[{"value":"1476-1122","type":"print"},{"value":"1476-4660","type":"electronic"}],"subject":[],"published":{"date-parts":[[2021,4,15]]},"assertion":[{"value":"26 May 2020","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"22 February 2021","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"15 April 2021","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"S.R. and F.M.P. hold shares of SensArs Neuroprosthetics Sarl, a start-up company dealing with the commercialization of neurocontrolled artificial limbs. G.V. declares no competing interests.","order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}]}}