{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,14]],"date-time":"2026-10-14T16:10:33Z","timestamp":1791994233295,"version":"4.4.0"},"reference-count":216,"publisher":"Springer Science and Business Media LLC","issue":"6","license":[{"start":{"date-parts":[[2026,3,23]],"date-time":"2026-03-23T00:00:00Z","timestamp":1774224000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.springernature.com\/gp\/researchers\/text-and-data-mining"},{"start":{"date-parts":[[2026,3,23]],"date-time":"2026-03-23T00:00:00Z","timestamp":1774224000000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/www.springernature.com\/gp\/researchers\/text-and-data-mining"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Nat Rev Drug Discov"],"published-print":{"date-parts":[[2026,6]]},"DOI":"10.1038\/s41573-026-01403-9","type":"journal-article","created":{"date-parts":[[2026,3,23]],"date-time":"2026-03-23T09:59:19Z","timestamp":1774259959000},"page":"448-468","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":7,"title":["Wearable technologies in clinical trials for drug development: trends and emerging opportunities"],"prefix":"10.1038","volume":"25","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-3439-7347","authenticated-orcid":false,"given":"Zahi A.","family":"Fayad","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Robert P.","family":"Hirten","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Girish N.","family":"Nadkarni","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-3892-7560","authenticated-orcid":false,"given":"Yun Soung","family":"Kim","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2026,3,23]]},"reference":[{"key":"1403_CR1","unstructured":"Knowles, M., Krasniansky, A. & Nagappan, A. Consumer adoption of digital health in 2022: moving at the speed of trust. RockHealth https:\/\/rockhealth.com\/insights\/consumer-adoption-of-digital-health-in-2022-moving-at-the-speed-of-trust\/ (2023)."},{"key":"1403_CR2","doi-asserted-by":"publisher","first-page":"e2221050","DOI":"10.1001\/jamanetworkopen.2022.21050","volume":"5","author":"BH Crotty","year":"2022","unstructured":"Crotty, B. H. et al. Hospitalization outcomes among patients with COVID-19 undergoing remote monitoring. JAMA Netw. Open. 5, e2221050\u2013e2221050 (2022).","journal-title":"JAMA Netw. Open."},{"key":"1403_CR3","unstructured":"Streed, J. COVID-19 remote patient monitoring study suggests improved outcomes, lower costs. Mayo Clinic News Network https:\/\/newsnetwork.mayoclinic.org\/discussion\/covid-19-remote-patient-monitoring-study-suggests-improved-outcomes-lower-costs\/ (2022)."},{"key":"1403_CR4","doi-asserted-by":"publisher","first-page":"e1278","DOI":"10.1200\/OP.21.00269","volume":"17","author":"B Daly","year":"2021","unstructured":"Daly, B. et al. Oncology patients\u2019 perspectives on remote patient monitoring for COVID-19. JCO Oncol. Pract. 17, e1278\u2013e1285 (2021).","journal-title":"JCO Oncol. Pract."},{"key":"1403_CR5","doi-asserted-by":"publisher","first-page":"517","DOI":"10.1016\/j.pop.2022.04.002","volume":"49","author":"J Shaver","year":"2022","unstructured":"Shaver, J. The state of telehealth before and after the COVID-19 pandemic. Prim. Care: Clin. Office Pract. 49, 517\u2013530 (2022).","journal-title":"Prim. Care: Clin. Office Pract."},{"key":"1403_CR6","doi-asserted-by":"publisher","first-page":"1125","DOI":"10.1001\/jama.2022.2040","volume":"327","author":"PJ Pronovost","year":"2022","unstructured":"Pronovost, P. J., Cole, M. D. & Hughes, R. M. Remote patient monitoring during COVID-19: an unexpected patient safety benefit. JAMA 327, 1125\u20131126 (2022).","journal-title":"JAMA"},{"key":"1403_CR7","doi-asserted-by":"crossref","unstructured":"Bairu, M., Spector, S. A. & Chin, R. in Global Clinical Trials for Alzheimer\u2019s Disease (eds Bairu, M. & Weiner, M. W.) 49\u201358 (Academic, 2014).","DOI":"10.1016\/B978-0-12-411464-7.00004-3"},{"key":"1403_CR8","doi-asserted-by":"publisher","DOI":"10.1038\/s41746-020-0302-y","volume":"3","author":"OT Inan","year":"2020","unstructured":"Inan, O. T. et al. Digitizing clinical trials. npj Digital Med. 3, 101 (2020).","journal-title":"npj Digital Med."},{"key":"1403_CR9","doi-asserted-by":"publisher","DOI":"10.1038\/s41746-023-00841-8","volume":"6","author":"M Mittermaier","year":"2023","unstructured":"Mittermaier, M., Venkatesh, K. P. & Kvedar, J. C. Digital health technology in clinical trials. npj Digital Med. 6, 88 (2023).","journal-title":"npj Digital Med."},{"key":"1403_CR10","doi-asserted-by":"publisher","DOI":"10.1038\/s41746-023-00767-1","volume":"6","author":"L Masanneck","year":"2023","unstructured":"Masanneck, L., Gieseler, P., Gordon, W. J., Meuth, S. G. & Stern, A. D. Evidence from ClinicalTrials.gov on the growth of digital health technologies in neurology trials. npj Digital Med. 6, 23 (2023).","journal-title":"npj Digital Med."},{"key":"1403_CR11","doi-asserted-by":"publisher","first-page":"652","DOI":"10.1161\/CIRCRESAHA.122.322389","volume":"132","author":"A Hughes","year":"2023","unstructured":"Hughes, A., Shandhi, M. M. H., Master, H., Dunn, J. & Brittain, E. Wearable devices in cardiovascular medicine. Circulation Res. 132, 652\u2013670 (2023).","journal-title":"Circulation Res."},{"key":"1403_CR12","doi-asserted-by":"publisher","DOI":"10.1016\/j.comnet.2021.108074","volume":"193","author":"A Ometov","year":"2021","unstructured":"Ometov, A. et al. A survey on wearable technology: history, state-of-the-art and current challenges. Computer Netw. 193, 108074 (2021).","journal-title":"Computer Netw."},{"key":"1403_CR13","doi-asserted-by":"publisher","first-page":"468","DOI":"10.1021\/acssensors.7b00045","volume":"2","author":"K Kalantar-Zadeh","year":"2017","unstructured":"Kalantar-Zadeh, K., Ha, N., Ou, J. Z. & Berean, K. J. Ingestible sensors. ACS Sens. 2, 468\u2013483 (2017).","journal-title":"ACS Sens."},{"key":"1403_CR14","doi-asserted-by":"publisher","first-page":"83","DOI":"10.1038\/s41578-018-0070-3","volume":"4","author":"C Steiger","year":"2019","unstructured":"Steiger, C. et al. Ingestible electronics for diagnostics and therapy. Nat. Rev. Mater. 4, 83\u201398 (2019).","journal-title":"Nat. Rev. Mater."},{"key":"1403_CR15","doi-asserted-by":"publisher","first-page":"1836","DOI":"10.1007\/s10620-020-06493-y","volume":"66","author":"RP Hirten","year":"2021","unstructured":"Hirten, R. P. et al. Wearable devices are well accepted by patients in the study and management of inflammatory bowel disease: a survey study. Dig. Dis. Sci. 66, 1836\u20131844 (2021).","journal-title":"Dig. Dis. Sci."},{"key":"1403_CR16","doi-asserted-by":"publisher","DOI":"10.1186\/s40691-019-0203-3","volume":"7","author":"C Nam","year":"2020","unstructured":"Nam, C. & Lee, Y.-A. Validation of the wearable acceptability range scale for smart apparel. Fash. Text. 7, 13 (2020).","journal-title":"Fash. Text."},{"key":"1403_CR17","doi-asserted-by":"publisher","DOI":"10.2196\/17037","volume":"8","author":"E Jeon","year":"2020","unstructured":"Jeon, E. et al. A lightweight deep learning model for fast electrocardiographic beats classification with a wearable cardiac monitor: development and validation study. JMIR Med. Inf. 8, e17037 (2020).","journal-title":"JMIR Med. Inf."},{"key":"1403_CR18","doi-asserted-by":"publisher","first-page":"177","DOI":"10.1007\/s00604-023-05743-w","volume":"190","author":"A Chmayssem","year":"2023","unstructured":"Chmayssem, A. et al. Insight into continuous glucose monitoring: from medical basics to commercialized devices. Mikrochim. Acta 190, 177 (2023).","journal-title":"Mikrochim. Acta"},{"key":"1403_CR19","doi-asserted-by":"publisher","first-page":"1024","DOI":"10.1016\/j.jaad.2021.11.055","volume":"87","author":"AR Atwater","year":"2022","unstructured":"Atwater, A. R. et al. Medical adhesive allergens: retrospective analysis of cross-sectional data from the North American Contact Dermatitis Group, 2001\u20132018. J. Am. Acad. Dermatol. 87, 1024\u20131032 (2022).","journal-title":"J. Am. Acad. Dermatol."},{"key":"1403_CR20","doi-asserted-by":"publisher","first-page":"ytz073","DOI":"10.1093\/ehjcr\/ytz073","volume":"3","author":"S Katzburg","year":"2019","unstructured":"Katzburg, S., Dor-Haim, H., Weiss, A. T. & Leibowitz, D. Detection of unexpected ischaemia due to left main disease during tele-rehabilitation using 12-lead electrocardiogram monitoring: a case report. Eur. Heart J. Case Rep. 3, ytz073 (2019).","journal-title":"Eur. Heart J. Case Rep."},{"key":"1403_CR21","first-page":"PA2271","volume":"58","author":"MCM Frade","year":"2021","unstructured":"Frade, M. C. M. et al. Wearables to monitoring the activities daily living in patients post-hospitalization by COVID-19. Eur. Respir. J. 58, PA2271 (2021).","journal-title":"Eur. Respir. J."},{"key":"1403_CR22","doi-asserted-by":"publisher","first-page":"193","DOI":"10.1038\/s41928-021-00558-0","volume":"4","author":"Y Luo","year":"2021","unstructured":"Luo, Y. et al. Learning human\u2013environment interactions using conformal tactile textiles. Nat. Electron. 4, 193\u2013201 (2021).","journal-title":"Nat. Electron."},{"key":"1403_CR23","doi-asserted-by":"publisher","first-page":"9884","DOI":"10.3390\/s120709884","volume":"12","author":"AH Razak","year":"2012","unstructured":"Razak, A. H., Zayegh, A., Begg, R. K. & Wahab, Y. Foot plantar pressure measurement system: a review. Sensors 12, 9884\u20139912 (2012).","journal-title":"Sensors"},{"key":"1403_CR24","doi-asserted-by":"publisher","first-page":"512","DOI":"10.1002\/pmrj.12003","volume":"11","author":"J Yeung","year":"2019","unstructured":"Yeung, J. et al. Evaluating the sensoria smart socks gait monitoring system for rehabilitation outcomes. PM R. 11, 512\u2013521 (2019).","journal-title":"PM R."},{"key":"1403_CR25","doi-asserted-by":"publisher","first-page":"2501","DOI":"10.3390\/s18082501","volume":"18","author":"MI Mokhlespour Esfahani","year":"2018","unstructured":"Mokhlespour Esfahani, M. I. & Nussbaum, M. A. Preferred placement and usability of a smart textile system vs. inertial measurement units for activity monitoring. Sensors 18, 2501 (2018).","journal-title":"Sensors"},{"key":"1403_CR26","doi-asserted-by":"publisher","first-page":"405","DOI":"10.3390\/electronics7120405","volume":"7","author":"TM Fern\u00e1ndez-Caram\u00e9s","year":"2018","unstructured":"Fern\u00e1ndez-Caram\u00e9s, T. M. & Fraga-Lamas, P. Towards the Internet of Smart Clothing: a review on IoT wearables and garments for creating intelligent connected e-textiles. Electronics 7, 405 (2018).","journal-title":"Electronics"},{"key":"1403_CR27","doi-asserted-by":"publisher","first-page":"109","DOI":"10.3389\/fnins.2017.00109","volume":"11","author":"OE Krigolson","year":"2017","unstructured":"Krigolson, O. E., Williams, C. C., Norton, A., Hassall, C. D. & Colino, F. L. Choosing MUSE: validation of a low-cost, portable EEG system for ERP research. Front. Neurosci. 11, 109 (2017).","journal-title":"Front. Neurosci."},{"key":"1403_CR28","doi-asserted-by":"publisher","first-page":"2100612","DOI":"10.1002\/admt.202100612","volume":"7","author":"L Yang","year":"2022","unstructured":"Yang, L. et al. Materials for dry electrodes for the electroencephalography: advances, challenges, perspectives. Adv. Mater. Technol. 7, 2100612 (2022).","journal-title":"Adv. Mater. Technol."},{"key":"1403_CR29","doi-asserted-by":"publisher","first-page":"012071","DOI":"10.1088\/1742-6596\/1505\/1\/012071","volume":"1505","author":"SH Pratama","year":"2020","unstructured":"Pratama, S. H. et al. Signal comparison of developed EEG device and emotiv insight based on brainwave characteristics analysis. J. Phys. Conf. Ser. 1505, 012071 (2020).","journal-title":"J. Phys. Conf. Ser."},{"key":"1403_CR30","doi-asserted-by":"publisher","first-page":"zsaa097","DOI":"10.1093\/sleep\/zsaa097","volume":"43","author":"PJ Arnal","year":"2020","unstructured":"Arnal, P. J. et al. The Dreem Headband compared to polysomnography for electroencephalographic signal acquisition and sleep staging. Sleep 43, zsaa097 (2020).","journal-title":"Sleep"},{"key":"1403_CR31","doi-asserted-by":"publisher","DOI":"10.2196\/35684","volume":"10","author":"HS Kang","year":"2022","unstructured":"Kang, H. S. & Exworthy, M. Wearing the future\u2014wearables to empower users to take greater responsibility for their health and care: scoping review. JMIR Mhealth Uhealth 10, e35684 (2022).","journal-title":"JMIR Mhealth Uhealth"},{"key":"1403_CR32","doi-asserted-by":"publisher","first-page":"S17","DOI":"10.1093\/ibd\/izab179","volume":"27","author":"YY Yau","year":"2021","unstructured":"Yau, Y. Y. et al. Current trends in IBD\u2014development of mucosal-based biomarkers and a novel minimally invasive recoverable sampling system. Inflamm. Bowel Dis. 27, S17\u2013S24 (2021).","journal-title":"Inflamm. Bowel Dis."},{"key":"1403_CR33","doi-asserted-by":"publisher","first-page":"575","DOI":"10.1016\/j.tibtech.2015.07.008","volume":"33","author":"CJ Bettinger","year":"2015","unstructured":"Bettinger, C. J. Materials advances for next-generation ingestible electronic medical devices. Trends Biotechnol. 33, 575\u2013585 (2015).","journal-title":"Trends Biotechnol."},{"key":"1403_CR34","first-page":"lsac029","volume":"9","author":"K Sideri","year":"2022","unstructured":"Sideri, K. et al. Digital pills for the remote monitoring of medication intake: a stakeholder analysis and assessment of marketing approval and patent granting policies. J. Law Biosci. 9, lsac029 (2022).","journal-title":"J. Law Biosci."},{"key":"1403_CR35","doi-asserted-by":"publisher","first-page":"102","DOI":"10.1038\/s41928-024-01122-2","volume":"7","author":"A Abdigazy","year":"2024","unstructured":"Abdigazy, A. et al. End-to-end design of ingestible electronics. Nat. Electron. 7, 102\u2013118 (2024).","journal-title":"Nat. Electron."},{"key":"1403_CR36","doi-asserted-by":"crossref","unstructured":"Ishii, S., Nkurikiyeyezu, K., Luimula, M., Yokokubo, A. & Lopez, G. in Activity and Behavior Computing (eds Ahad, Md A. R., Inoue, S., Roggen, D. & Fujinami, K.) 239\u2013255 (Springer Singapore, 2021).","DOI":"10.1007\/978-981-15-8944-7_15"},{"key":"1403_CR37","doi-asserted-by":"publisher","first-page":"1187","DOI":"10.1109\/JSEN.2020.3019016","volume":"21","author":"M Rana","year":"2021","unstructured":"Rana, M. & Mittal, V. Wearable sensors for real-time kinematics analysis in sports: a review. Ieee Sens. J. 21, 1187\u20131207 (2021).","journal-title":"Ieee Sens. J."},{"key":"1403_CR38","doi-asserted-by":"publisher","DOI":"10.2196\/35626","volume":"10","author":"G Chevance","year":"2022","unstructured":"Chevance, G. et al. Accuracy and precision of energy expenditure, heart rate, and steps measured by combined-sensing Fitbits against reference measures: systematic review and meta-analysis. JMIR Mhealth Uhealth 10, e35626 (2022).","journal-title":"JMIR Mhealth Uhealth"},{"key":"1403_CR39","doi-asserted-by":"publisher","first-page":"2016","DOI":"10.1109\/TBME.2017.2676243","volume":"64","author":"A Temko","year":"2017","unstructured":"Temko, A. Accurate heart rate monitoring during physical exercises using PPG. IEEE Trans. Biomed. Eng. 64, 2016\u20132024 (2017).","journal-title":"IEEE Trans. Biomed. Eng."},{"key":"1403_CR40","doi-asserted-by":"publisher","first-page":"90","DOI":"10.1038\/s41746-020-0297-4","volume":"3","author":"BW Nelson","year":"2020","unstructured":"Nelson, B. W. et al. Guidelines for wrist-worn consumer wearable assessment of heart rate in biobehavioral research. npj Digit. Med. 3, 90 (2020).","journal-title":"npj Digit. Med."},{"key":"1403_CR41","first-page":"45","volume":"36","author":"S Bagha","year":"2011","unstructured":"Bagha, S. & Shaw, L. A real time analysis of PPG signal for measurement of SpO2 and pulse rate. Int. J. Computer Appl. 36, 45\u201350 (2011).","journal-title":"Int. J. Computer Appl."},{"key":"1403_CR42","doi-asserted-by":"publisher","first-page":"219","DOI":"10.1016\/j.amjmed.2014.09.016","volume":"128","author":"M Bohm","year":"2015","unstructured":"Bohm, M., Reil, J. C., Deedwania, P., Kim, J. B. & Borer, J. S. Resting heart rate: risk indicator and emerging risk factor in cardiovascular disease. Am. J. Med. 128, 219\u2013228 (2015).","journal-title":"Am. J. Med."},{"key":"1403_CR43","doi-asserted-by":"publisher","first-page":"823","DOI":"10.1016\/j.jacc.2007.04.079","volume":"50","author":"K Fox","year":"2007","unstructured":"Fox, K. et al. Resting heart rate in cardiovascular disease. J. Am. Coll. Cardiol. 50, 823\u2013830 (2007).","journal-title":"J. Am. Coll. Cardiol."},{"key":"1403_CR44","doi-asserted-by":"publisher","first-page":"719","DOI":"10.1002\/clc.4960211005","volume":"21","author":"A Stys","year":"1998","unstructured":"Stys, A. & Stys, T. Current clinical applications of heart rate variability. Clin. Cardiol. 21, 719\u2013724 (1998).","journal-title":"Clin. Cardiol."},{"key":"1403_CR45","doi-asserted-by":"publisher","first-page":"3571","DOI":"10.3390\/s21103571","volume":"21","author":"CR Bellenger","year":"2021","unstructured":"Bellenger, C. R., Miller, D. J., Halson, S. L., Roach, G. D. & Sargent, C. Wrist-based photoplethysmography assessment of heart rate and heart rate variability: validation of WHOOP. Sensors 21, 3571 (2021).","journal-title":"Sensors"},{"key":"1403_CR46","doi-asserted-by":"publisher","DOI":"10.2196\/62769","volume":"26","author":"S Singh","year":"2024","unstructured":"Singh, S. et al. Impact of skin pigmentation on pulse oximetry blood oxygenation and wearable pulse rate accuracy: systematic review and meta-analysis. J. Med. Internet Res. 26, e62769 (2024).","journal-title":"J. Med. Internet Res."},{"key":"1403_CR47","doi-asserted-by":"publisher","first-page":"1479","DOI":"10.1109\/TBME.2016.2609282","volume":"64","author":"W Wang","year":"2017","unstructured":"Wang, W., Brinker, A. C. D., Stuijk, S. & Haan, G. D. Algorithmic principles of remote PPG. IEEE Trans. Biomed. Eng. 64, 1479\u20131491 (2017).","journal-title":"IEEE Trans. Biomed. Eng."},{"key":"1403_CR48","doi-asserted-by":"publisher","DOI":"10.1038\/s41598-025-23103-x","volume":"15","author":"J Lee","year":"2025","unstructured":"Lee, J. et al. Multi-task learning for estimation of remote PPG and respiration signals with complex valued convolutional neural network. Sci. Rep. 15, 39272 (2025).","journal-title":"Sci. Rep."},{"key":"1403_CR49","doi-asserted-by":"publisher","first-page":"901","DOI":"10.1007\/s00542-019-04594-x","volume":"26","author":"SS Kumar","year":"2020","unstructured":"Kumar, S. S. & Tanwar, A. Development of a MEMS-based barometric pressure sensor for micro air vehicle (MAV) altitude measurement. Microsyst. Technol. 26, 901\u2013912 (2020).","journal-title":"Microsyst. Technol."},{"key":"1403_CR50","doi-asserted-by":"crossref","unstructured":"Bolanakis, D. E. MEMS barometers in a wireless sensor network for position location applications. In Proc. 2016 IEEE Virtual Conference on Applications of Commercial Sensors (VCACS) (ed. Ozanyan, K. B.) 1\u20138 (IEEE, 2016).","DOI":"10.1109\/VCACS.2016.7888784"},{"key":"1403_CR51","doi-asserted-by":"publisher","first-page":"6786","DOI":"10.3390\/s20236786","volume":"20","author":"A Manivannan","year":"2020","unstructured":"Manivannan, A., Chin, W. C. B., Barrat, A. & Bouffanais, R. On the challenges and potential of using barometric sensors to track human activity. Sensors 20, 6786 (2020).","journal-title":"Sensors"},{"key":"1403_CR52","doi-asserted-by":"publisher","DOI":"10.1002\/adhm.201601371","volume":"6","author":"Q Li","year":"2017","unstructured":"Li, Q., Zhang, L.-N., Tao, X.-M. & Ding, X. Review of flexible temperature sensing networks for wearable physiological monitoring. Adv. Healthc. Mater. 6, 1601371 (2017).","journal-title":"Adv. Healthc. Mater."},{"key":"1403_CR53","doi-asserted-by":"publisher","DOI":"10.1016\/j.measurement.2022.112338","volume":"206","author":"X Ren","year":"2023","unstructured":"Ren, X., Zhang, Y., Ye, X. & Zhou, C. Study of perfusion based theoretical model and experimental evaluation for wearable CBT measurement. Measurement 206, 112338 (2023).","journal-title":"Measurement"},{"key":"1403_CR54","doi-asserted-by":"publisher","first-page":"16742","DOI":"10.1109\/JSEN.2021.3071825","volume":"22","author":"X Ren","year":"2022","unstructured":"Ren, X., Zhou, C. & Ye, X. A novel miniaturized sandwich-like sensor for continuous measurement of core body temperature. IEEE Sens. J. 22, 16742\u201316749 (2022).","journal-title":"IEEE Sens. J."},{"key":"1403_CR55","doi-asserted-by":"publisher","DOI":"10.1186\/s12938-023-01081-3","volume":"22","author":"S Etienne","year":"2023","unstructured":"Etienne, S. et al. Free-living core body temperature monitoring using a wrist-worn sensor after COVID-19 booster vaccination: a pilot study. Biomed. Eng. Online 22, 25 (2023).","journal-title":"Biomed. Eng. Online"},{"key":"1403_CR56","doi-asserted-by":"publisher","DOI":"10.1371\/journal.pbio.2001402","volume":"15","author":"X Li","year":"2017","unstructured":"Li, X. et al. Digital health: tracking physiomes and activity using wearable biosensors reveals useful health-related information. PLoS Biol. 15, e2001402 (2017).","journal-title":"PLoS Biol."},{"key":"1403_CR57","doi-asserted-by":"publisher","first-page":"1208","DOI":"10.1038\/s41551-020-00640-6","volume":"4","author":"T Mishra","year":"2020","unstructured":"Mishra, T. et al. Pre-symptomatic detection of COVID-19 from smartwatch data. Nat. Biomed. Eng. 4, 1208\u20131220 (2020).","journal-title":"Nat. Biomed. Eng."},{"key":"1403_CR58","doi-asserted-by":"publisher","first-page":"35","DOI":"10.1038\/s44294-024-00037-9","volume":"2","author":"G Lin","year":"2024","unstructured":"Lin, G. et al. Understanding wrist skin temperature changes to hormone variations across the menstrual cycle. npj Women\u2019s Health 2, 35 (2024).","journal-title":"npj Women\u2019s Health"},{"key":"1403_CR59","doi-asserted-by":"crossref","unstructured":"Bonelli, P., Giannini, I., Matassini, M. V. & Menditto, A. in New Concepts in ECG Interpretation (ed. Capucci, A.) 137\u2013146 (Springer International, 2019).","DOI":"10.1007\/978-3-319-91677-4_13"},{"key":"1403_CR60","doi-asserted-by":"publisher","DOI":"10.1155\/2021\/6653971","volume":"2021","author":"Sp\u00eenu","year":"2021","unstructured":"Sp\u00eenu et al. ECG markers of cardiovascular toxicity in adult and pediatric cancer treatment. Dis. Markers 2021, 6653971 (2021).","journal-title":"Dis. Markers"},{"key":"1403_CR61","doi-asserted-by":"publisher","first-page":"5847","DOI":"10.3390\/s23135847","volume":"23","author":"V Ronca","year":"2023","unstructured":"Ronca, V. et al. Wearable technologies for electrodermal and cardiac activity measurements: a comparison between fitbit sense, Empatica E4 and Shimmer GSR3. Sensors 23, 5847 (2023).","journal-title":"Sensors"},{"key":"1403_CR62","doi-asserted-by":"crossref","unstructured":"Greco, A., Valenza, G. & Scilingo, E. P. Advances in Electrodermal Activity Processing with Applications for Mental Health (Springer, 2016).","DOI":"10.1007\/978-3-319-46705-4"},{"key":"1403_CR63","doi-asserted-by":"publisher","DOI":"10.1186\/s12888-017-1551-4","volume":"18","author":"M Sarchiapone","year":"2018","unstructured":"Sarchiapone, M. et al. The association between electrodermal activity (EDA), depression and suicidal behaviour: a systematic review and narrative synthesis. BMC Psychiatry 18, 22 (2018).","journal-title":"BMC Psychiatry"},{"key":"1403_CR64","first-page":"344","volume":"27","author":"H Moonen","year":"2021","unstructured":"Moonen, H. & Van Zanten, A. R. H. Bioelectric impedance analysis for body composition measurement and other potential clinical applications in critical illness. Curr. Opin. Crit. Care 27, 344\u2013353 (2021).","journal-title":"Curr. Opin. Crit. Care"},{"key":"1403_CR65","doi-asserted-by":"publisher","DOI":"10.1038\/s41598-020-79667-3","volume":"11","author":"MH Jung","year":"2021","unstructured":"Jung, M. H. et al. Wrist-wearable bioelectrical impedance analyzer with miniature electrodes for daily obesity management. Sci. Rep. 11, 1238 (2021).","journal-title":"Sci. Rep."},{"key":"1403_CR66","doi-asserted-by":"publisher","DOI":"10.2196\/22911","volume":"6","author":"W Groenendaal","year":"2021","unstructured":"Groenendaal, W., Lee, S. & van Hoof, C. Wearable bioimpedance monitoring: viewpoint for application in chronic conditions. JMIR Biomed. Eng. 6, e22911 (2021).","journal-title":"JMIR Biomed. Eng."},{"key":"1403_CR67","doi-asserted-by":"publisher","first-page":"10895","DOI":"10.3390\/s140610895","volume":"14","author":"SF Khalil","year":"2014","unstructured":"Khalil, S. F., Mohktar, M. S. & Ibrahim, F. The theory and fundamentals of bioimpedance analysis in clinical status monitoring and diagnosis of diseases. Sensors-Basel 14, 10895\u201310928 (2014).","journal-title":"Sensors-Basel"},{"key":"1403_CR68","doi-asserted-by":"publisher","first-page":"172","DOI":"10.1139\/apnm-2022-0301","volume":"48","author":"CF Brandner","year":"2023","unstructured":"Brandner, C. F., Tinsley, G. M. & Graybeal, A. J. Smartwatch-based bioimpedance analysis for body composition estimation: precision and agreement with a 4-compartment model. Appl. Physiol. Nutr. Metab. 48, 172\u2013182 (2023).","journal-title":"Appl. Physiol. Nutr. Metab."},{"key":"1403_CR69","doi-asserted-by":"crossref","unstructured":"Chamberlain, D., Mofor, J., Fletcher, R. & Kodgule, R. Mobile stethoscope and signal processing algorithms for pulmonary screening and diagnostics. In Proc. 2015 IEEE Global Humanitarian Technology Conference (GHTC) (eds Figueira, S. & Decuir, J.) 385\u2013392 (IEEE, 2015).","DOI":"10.1109\/GHTC.2015.7344001"},{"key":"1403_CR70","doi-asserted-by":"publisher","DOI":"10.1016\/j.dib.2021.106913","volume":"35","author":"M Fraiwan","year":"2021","unstructured":"Fraiwan, M., Fraiwan, L., Khassawneh, B. & Ibnian, A. A dataset of lung sounds recorded from the chest wall using an electronic stethoscope. Data Brief. 35, 106913 (2021).","journal-title":"Data Brief."},{"key":"1403_CR71","doi-asserted-by":"crossref","unstructured":"Malik, B. et al. Design and development of an electronic stethoscope. In Proc. 2017 Internet Technologies and Applications (ITA) (eds Grout, V. & Houlden, N.) 324\u2013328 (IEEE, 2017).","DOI":"10.1109\/ITECHA.2017.8101963"},{"key":"1403_CR72","doi-asserted-by":"publisher","first-page":"813","DOI":"10.1007\/s42600-022-00222-2","volume":"38","author":"C Wanderley Espinola","year":"2022","unstructured":"Wanderley Espinola, C., Gomes, J. C., M\u00f4nica Silva Pereira, J. & dos Santos, W. P. Detection of major depressive disorder, bipolar disorder, schizophrenia and generalized anxiety disorder using vocal acoustic analysis and machine learning: an exploratory study. Res. Biomed. Eng. 38, 813\u2013829 (2022).","journal-title":"Res. Biomed. Eng."},{"key":"1403_CR73","doi-asserted-by":"publisher","first-page":"3153","DOI":"10.3390\/diagnostics13193153","volume":"13","author":"D Magor","year":"2023","unstructured":"Magor, D. et al. Interpretation of heart and lungs sounds acquired via remote, digital auscultation reached fair-to-substantial levels of consensus among specialist physicians. Diagnostics 13, 3153 (2023).","journal-title":"Diagnostics"},{"key":"1403_CR74","first-page":"012007","volume":"1687","author":"CP Loizou","year":"2020","unstructured":"Loizou, C. P. & Christodoulides, P. Voice signal analysis techniques for cognitive decline (stress) assessment. J. Physics: Conf. Ser. 1687, 012007 (2020).","journal-title":"J. Physics: Conf. Ser."},{"key":"1403_CR75","doi-asserted-by":"publisher","first-page":"057514","DOI":"10.1149\/1945-7111\/ac6980","volume":"169","author":"Y Jing","year":"2022","unstructured":"Jing, Y., Chang, S. J., Chen, C.-J. & Liu, J.-T. Review\u2014glucose monitoring sensors: history, principle, and challenges. J. Electrochem. Soc. 169, 057514 (2022).","journal-title":"J. Electrochem. Soc."},{"key":"1403_CR76","doi-asserted-by":"publisher","first-page":"42","DOI":"10.1016\/S2213-8587(22)00319-9","volume":"11","author":"T Battelino","year":"2023","unstructured":"Battelino, T. et al. Continuous glucose monitoring and metrics for clinical trials: an international consensus statement. Lancet Diabetes Endocrinol. 11, 42\u201357 (2023).","journal-title":"Lancet Diabetes Endocrinol."},{"key":"1403_CR77","doi-asserted-by":"publisher","first-page":"160","DOI":"10.2337\/cd20-0049","volume":"39","author":"BQ Fox","year":"2021","unstructured":"Fox, B. Q. et al. Continuous glucose monitoring use in clinical trials for on-market diabetes drugs. Clin. Diabetes 39, 160\u2013166 (2021).","journal-title":"Clin. Diabetes"},{"key":"1403_CR78","unstructured":"US National Library of Medicine. ClinicalTrials.gov https:\/\/clinicaltrials.gov\/study\/NCT00084669 (2010)."},{"key":"1403_CR79","unstructured":"US National Library of Medicine. ClinicalTrials.gov https:\/\/clinicaltrials.gov\/study\/NCT00386334 (2016)."},{"key":"1403_CR80","unstructured":"US National Library of Medicine. ClinicalTrials.gov https:\/\/clinicaltrials.gov\/study\/NCT00441129 (2018)."},{"key":"1403_CR81","unstructured":"US National Library of Medicine. ClinicalTrials.gov https:\/\/clinicaltrials.gov\/study\/NCT00797823 (2011)."},{"key":"1403_CR82","unstructured":"US National Library of Medicine. ClinicalTrials.gov https:\/\/clinicaltrials.gov\/study\/NCT03591354 (2022)."},{"key":"1403_CR83","unstructured":"US National Library of Medicine. ClinicalTrials.gov https:\/\/clinicaltrials.gov\/study\/NCT01535612 (2016)."},{"key":"1403_CR84","unstructured":"US National Library of Medicine. ClinicalTrials.gov https:\/\/clinicaltrials.gov\/study\/NCT02735187 (2019)."},{"key":"1403_CR85","unstructured":"US National Library of Medicine. ClinicalTrials.gov https:\/\/clinicaltrials.gov\/study\/NCT02091882 (2021)."},{"key":"1403_CR86","unstructured":"US National Library of Medicine. ClinicalTrials.gov https:\/\/clinicaltrials.gov\/study\/NCT03842436 (2022)."},{"key":"1403_CR87","unstructured":"US National Library of Medicine. ClinicalTrials.gov https:\/\/clinicaltrials.gov\/study\/NCT03772327 (2019)."},{"key":"1403_CR88","unstructured":"US National Library of Medicine. ClinicalTrials.gov https:\/\/clinicaltrials.gov\/study\/NCT00446264 (2012)."},{"key":"1403_CR89","unstructured":"US National Library of Medicine. ClinicalTrials.gov https:\/\/clinicaltrials.gov\/study\/NCT00211510 (2017)."},{"key":"1403_CR90","unstructured":"US National Library of Medicine. ClinicalTrials.gov https:\/\/clinicaltrials.gov\/study\/NCT00573261 (2014)."},{"key":"1403_CR91","unstructured":"US National Library of Medicine. ClinicalTrials.gov https:\/\/clinicaltrials.gov\/study\/NCT03568500 (2020)."},{"key":"1403_CR92","unstructured":"US National Library of Medicine. ClinicalTrials.gov https:\/\/clinicaltrials.gov\/study\/NCT05664711 (2024)."},{"key":"1403_CR93","doi-asserted-by":"publisher","first-page":"10778","DOI":"10.3390\/app142310778","volume":"14","author":"M Fiore","year":"2024","unstructured":"Fiore, M. et al. The use of smart rings in health monitoring\u2014a meta-analysis. Appl. Sci. 14, 10778 (2024).","journal-title":"Appl. Sci."},{"key":"1403_CR94","unstructured":"US National Library of Medicine. ClinicalTrials.gov https:\/\/clinicaltrials.gov\/study\/NCT03671759 (2022)."},{"key":"1403_CR95","doi-asserted-by":"publisher","DOI":"10.1016\/j.cct.2020.105962","volume":"91","author":"MK Walton","year":"2020","unstructured":"Walton, M. K. et al. Considerations for development of an evidence dossier to support the use of mobile sensor technology for clinical outcome assessments in clinical trials. Contemporary Clin. Trials 91, 105962 (2020).","journal-title":"Contemporary Clin. Trials"},{"key":"1403_CR96","doi-asserted-by":"publisher","DOI":"10.1038\/s41746-022-00583-z","volume":"5","author":"S Vasudevan","year":"2022","unstructured":"Vasudevan, S., Saha, A., Tarver, M. E. & Patel, B. Digital biomarkers: convergence of digital health technologies and biomarkers. npj Digital Med. 5, 36 (2022).","journal-title":"npj Digital Med."},{"key":"1403_CR97","doi-asserted-by":"publisher","DOI":"10.1038\/s41746-020-0305-8","volume":"3","author":"KI Taylor","year":"2020","unstructured":"Taylor, K. I., Staunton, H., Lipsmeier, F., Nobbs, D. & Lindemann, M. Outcome measures based on digital health technology sensor data: data- and patient-centric approaches. npj Digital Med. 3, 97 (2020).","journal-title":"npj Digital Med."},{"key":"1403_CR98","doi-asserted-by":"publisher","DOI":"10.1038\/s41746-019-0090-4","volume":"2","author":"A Coravos","year":"2019","unstructured":"Coravos, A., Khozin, S. & Mandl, K. D. Developing and adopting safe and effective digital biomarkers to improve patient outcomes. npj Digital Med. 2, 14 (2019).","journal-title":"npj Digital Med."},{"key":"1403_CR99","doi-asserted-by":"publisher","first-page":"56","DOI":"10.1002\/cpt.3398","volume":"117","author":"JP Bakker","year":"2025","unstructured":"Bakker, J. P. et al. Regulatory pathways for qualification and acceptance of digital health technology-derived clinical trial endpoints: considerations for sponsors. Clin. Pharmacology Therapeutics 117, 56\u201372 (2025).","journal-title":"Clin. Pharmacology Therapeutics"},{"key":"1403_CR100","unstructured":"US Food and Drug Administration. Medical Device Development Tools (MDDT). FDA https:\/\/www.fda.gov\/medical-devices\/medical-device-development-tools-mddt (2024)."},{"key":"1403_CR101","doi-asserted-by":"publisher","first-page":"619513","DOI":"10.3389\/fmed.2021.619513","volume":"8-2021","author":"MJHJ Dekker","year":"2021","unstructured":"Dekker, M. J. H. J., Stolk, P. & Pasmooij, A. M. G. The use of remote monitoring technologies: a review of recent regulatory scientific advices, qualification opinions, and qualification advices issued by the European Medicines Agency. Front. Med. 8-2021, 619513 (2021).","journal-title":"Front. Med."},{"key":"1403_CR102","unstructured":"US Food and Drug Administration. Classify your medical device. FDA https:\/\/www.fda.gov\/medical-devices\/overview-device-regulation\/classify-your-medical-device (2020)."},{"key":"1403_CR103","unstructured":"European Parliament and Council. Regulation (EU) 2017\/745 on medical devices. (2017). EUROPA https:\/\/eur-lex.europa.eu\/eli\/reg\/2017\/745\/oj (2025)."},{"key":"1403_CR104","doi-asserted-by":"publisher","first-page":"25","DOI":"10.1111\/epi.18034","volume":"66","author":"G Miron","year":"2025","unstructured":"Miron, G., Halimeh, M., Jeppesen, J., Loddenkemper, T. & Meisel, C. Autonomic biosignals, seizure detection, and forecasting. Epilepsia 66, 25\u201338 (2025).","journal-title":"Epilepsia"},{"key":"1403_CR105","doi-asserted-by":"crossref","unstructured":"Nayab, H. & Khan, M. S. Review on digital stethoscopes in chest auscultation for personal use. In 2024 IEEE 13th Global Conference on Consumer Electronics (GCCE) (eds Ikehara, T. & Uemura, W.) 836\u2013839 (IEEE, 2024).","DOI":"10.1109\/GCCE62371.2024.10760358"},{"key":"1403_CR106","doi-asserted-by":"publisher","DOI":"10.1038\/s41746-020-0260-4","volume":"3","author":"JC Goldsack","year":"2020","unstructured":"Goldsack, J. C. et al. Verification, analytical validation, and clinical validation (V3): the foundation of determining fit-for-purpose for Biometric Monitoring Technologies (BioMeTs). npj Digital Med. 3, 55 (2020).","journal-title":"npj Digital Med."},{"key":"1403_CR107","doi-asserted-by":"publisher","DOI":"10.1038\/s41746-024-01322-2","volume":"8","author":"JP Bakker","year":"2025","unstructured":"Bakker, J. P. et al. V3+ extends the V3 framework to ensure user-centricity and scalability of sensor-based digital health technologies. npj Digital Med. 8, 51 (2025).","journal-title":"npj Digital Med."},{"key":"1403_CR108","doi-asserted-by":"publisher","first-page":"183","DOI":"10.1159\/000517411","volume":"5","author":"L Servais","year":"2021","unstructured":"Servais, L. et al. First regulatory qualification of a novel digital endpoint in duchenne muscular dystrophy: a multi-stakeholder perspective on the impact for patients and for drug development in neuromuscular diseases. Digital Biomarkers 5, 183\u2013190 (2021).","journal-title":"Digital Biomarkers"},{"key":"1403_CR109","unstructured":"US National Library of Medicine. ClinicalTrials.gov https:\/\/clinicaltrials.gov\/study\/NCT05096221 (2025)."},{"key":"1403_CR110","unstructured":"US National Library of Medicine. ClinicalTrials.gov https:\/\/clinicaltrials.gov\/study\/NCT03039686 (2020)."},{"key":"1403_CR111","unstructured":"US National Library of Medicine. ClinicalTrials.gov https:\/\/clinicaltrials.gov\/study\/NCT06138639 (2026)."},{"key":"1403_CR112","unstructured":"US National Library of Medicine. ClinicalTrials.gov https:\/\/clinicaltrials.gov\/study\/NCT04906460 (2025)."},{"key":"1403_CR113","unstructured":"US National Library of Medicine. ClinicalTrials.gov https:\/\/clinicaltrials.gov\/study\/NCT05524883 (2025)."},{"key":"1403_CR114","unstructured":"US Food and Drug Administration. Integrated clinical and clinical pharmacology review memorandum. FDA https:\/\/www.fda.gov\/media\/179486\/download (2024)."},{"key":"1403_CR115","doi-asserted-by":"publisher","first-page":"189","DOI":"10.1038\/s42255-024-00973-5","volume":"6","author":"MM Visser","year":"2024","unstructured":"Visser, M. M. & Gillard, P. Best practices in collecting and reporting continuous glucose monitoring data in research settings. Nat. Metab. 6, 189\u2013191 (2024).","journal-title":"Nat. Metab."},{"key":"1403_CR116","unstructured":"US National Library of Medicine. ClinicalTrials.gov https:\/\/clinicaltrials.gov\/study\/NCT04605497 (2024)."},{"key":"1403_CR117","unstructured":"US National Library of Medicine. ClinicalTrials.gov https:\/\/clinicaltrials.gov\/study\/NCT04075513 (2022)."},{"key":"1403_CR118","unstructured":"Food and Drug Administration, Center for Drug Evaluation and Research. Diabetes mellitus: efficacy endpoints for clinical trials investigating antidiabetic drugs and biological products; draft guidance for industry; availability. regulations.gov https:\/\/www.regulations.gov\/docket\/FDA-2023-D-0625 (2023)."},{"key":"1403_CR119","unstructured":"US National Library of Medicine. ClinicalTrials.gov https:\/\/clinicaltrials.gov\/study\/NCT05747508 (2023)."},{"key":"1403_CR120","doi-asserted-by":"publisher","first-page":"594","DOI":"10.1513\/AnnalsATS.202107-864OC","volume":"19","author":"CS King","year":"2022","unstructured":"King, C. S. et al. A phase-2 exploratory randomized controlled trial of INOpulse in patients with fibrotic interstitial lung disease requiring oxygen. Ann. Am. Thorac. Soc. 19, 594\u2013602 (2022).","journal-title":"Ann. Am. Thorac. Soc."},{"key":"1403_CR121","unstructured":"US National Library of Medicine. ClinicalTrials.gov https:\/\/clinicaltrials.gov\/study\/NCT03267108 (2023)."},{"key":"1403_CR122","doi-asserted-by":"publisher","DOI":"10.1186\/s12916-024-03590-x","volume":"22","author":"S Tackney Mia","year":"2024","unstructured":"Tackney Mia, S., Carpenter James, R. & Villar Sof\u00eda, S. Unleashing the full potential of digital outcome measures in clinical trials: eight questions that need attention. BMC Med. 22, 413 (2024).","journal-title":"BMC Med."},{"key":"1403_CR123","unstructured":"US National Library of Medicine. ClinicalTrials.gov https:\/\/clinicaltrials.gov\/study\/NCT03181503 (2020)."},{"key":"1403_CR124","doi-asserted-by":"publisher","first-page":"1820","DOI":"10.1111\/jdv.18377","volume":"36","author":"S St\u00e4nder","year":"2022","unstructured":"St\u00e4nder, S. et al. Nemolizumab efficacy in prurigo nodularis: onset of action on itch and sleep disturbances. J. Eur. Acad. Dermatol. Venereol. 36, 1820\u20131825 (2022).","journal-title":"J. Eur. Acad. Dermatol. Venereol."},{"key":"1403_CR125","unstructured":"US National Library of Medicine. ClinicalTrials.gov https:\/\/clinicaltrials.gov\/study\/NCT03989349 (2024)."},{"key":"1403_CR126","doi-asserted-by":"publisher","first-page":"73","DOI":"10.1186\/s41687-024-00751-7","volume":"8","author":"C Dias-Barbosa","year":"2024","unstructured":"Dias-Barbosa, C. et al. Capturing patient-reported sleep disturbance in atopic dermatitis clinical trials. J. Patient-Reported Outcomes 8, 73 (2024).","journal-title":"J. Patient-Reported Outcomes"},{"key":"1403_CR127","doi-asserted-by":"publisher","first-page":"963","DOI":"10.1007\/s13555-025-01385-3","volume":"15","author":"JI Silverberg","year":"2025","unstructured":"Silverberg, J. I. et al. Psychometric validation of the subject sleep diary in patients with moderate-to-severe atopic dermatitis. Dermatology Ther. 15, 963\u2013995 (2025).","journal-title":"Dermatology Ther."},{"key":"1403_CR128","unstructured":"European Medicines Agency. Committee for Medicinal Products for Human Use summary of positive opinion for Nemluvio. EUROPA https:\/\/www.ema.europa.eu\/en\/documents\/assessment-report\/nemluvio-epar-public-assessment-report_en.pdf (2024)."},{"key":"1403_CR129","unstructured":"US National Library of Medicine. ClinicalTrials.gov https:\/\/clinicaltrials.gov\/study\/NCT04433091 (2024)."},{"key":"1403_CR130","unstructured":"US Food and Drug Administration. Medical Device Development Tool (MDDT) Summary of Evidence and Basis of Qualification (SEBQ) for Apple Atrial Fibrillation History feature. FDA https:\/\/www.fda.gov\/files\/medical%20devices\/published\/U230116-MDDT-SEBQ.pdf (2024)."},{"key":"1403_CR131","doi-asserted-by":"crossref","unstructured":"Sol\u00e0, J. & Delgado-Gonzalo, R. The Handbook of Cuffless Blood Pressure Monitoring (Springer, 2019).","DOI":"10.1007\/978-3-030-24701-0"},{"key":"1403_CR132","doi-asserted-by":"publisher","first-page":"1879","DOI":"10.1109\/TBME.2015.2441951","volume":"62","author":"R Mukkamala","year":"2015","unstructured":"Mukkamala, R. et al. Toward ubiquitous blood pressure monitoring via pulse transit time: theory and practice. IEEE Trans. Biomed. Eng. 62, 1879\u20131901 (2015).","journal-title":"IEEE Trans. Biomed. Eng."},{"key":"1403_CR133","unstructured":"Kyriacou, P. A. & Allen, J. Photoplethysmography: Technology, Signal Analysis and Applications (Academic, 2021)."},{"key":"1403_CR134","doi-asserted-by":"publisher","first-page":"R1","DOI":"10.1088\/0967-3334\/36\/3\/R1","volume":"36","author":"D Buxi","year":"2015","unstructured":"Buxi, D., Redoute, J. M. & Yuce, M. R. A survey on signals and systems in ambulatory blood pressure monitoring using pulse transit time. Physiol. Meas. 36, R1\u2013R26 (2015).","journal-title":"Physiol. Meas."},{"key":"1403_CR135","doi-asserted-by":"publisher","first-page":"21","DOI":"10.3390\/technologies5020021","volume":"5","author":"M Sharma","year":"2017","unstructured":"Sharma, M. et al. Cuff-less and continuous blood pressure monitoring: a methodological review. Technologies 5, 21 (2017).","journal-title":"Technologies"},{"key":"1403_CR136","doi-asserted-by":"publisher","first-page":"203","DOI":"10.1146\/annurev-bioeng-110220-014644","volume":"24","author":"R Mukkamala","year":"2022","unstructured":"Mukkamala, R., Stergiou, G. S. & Avolio, A. P. Cuffless blood pressure measurement. Annu. Rev. Biomed. Eng. 24, 203\u2013230 (2022).","journal-title":"Annu. Rev. Biomed. Eng."},{"key":"1403_CR137","doi-asserted-by":"publisher","DOI":"10.1038\/s41598-021-99294-w","volume":"11","author":"J Sola","year":"2021","unstructured":"Sola, J. et al. Validation of the optical Aktiia bracelet in different body positions for the persistent monitoring of blood pressure. Sci. Rep. 11, 20644 (2021).","journal-title":"Sci. Rep."},{"key":"1403_CR138","doi-asserted-by":"publisher","first-page":"1456","DOI":"10.1038\/s41440-023-01258-2","volume":"46","author":"TP Almeida","year":"2023","unstructured":"Almeida, T. P. et al. Aktiia cuffless blood pressure monitor yields equivalent daytime blood pressure measurements compared to a 24-h ambulatory blood pressure monitor: preliminary results from a prospective single-center study. Hypertens. Res. 46, 1456\u20131461 (2023).","journal-title":"Hypertens. Res."},{"key":"1403_CR139","doi-asserted-by":"publisher","first-page":"1003","DOI":"10.1097\/HJH.0000000000003428","volume":"41","author":"I Tan","year":"2023","unstructured":"Tan, I. et al. Evaluation of the ability of a commercially available cuffless wearable device to track blood pressure changes. J. Hypertens. 41, 1003\u20131010 (2023).","journal-title":"J. Hypertens."},{"key":"1403_CR140","doi-asserted-by":"publisher","first-page":"ehad655","DOI":"10.1093\/eurheartj\/ehad655.2933","volume":"44","author":"E Ronner","year":"2023","unstructured":"Ronner, E. et al. Validation of a novel cuffless photoplethysmography-based wristband for measuring blood pressure according to the regulatory standard. Eur. Heart J. 44, ehad655 (2023). 2933.","journal-title":"Eur. Heart J."},{"key":"1403_CR141","doi-asserted-by":"publisher","DOI":"10.1038\/s41598-020-73172-3","volume":"10","author":"D Nachman","year":"2020","unstructured":"Nachman, D. et al. Comparing blood pressure measurements between a photoplethysmography-based and a standard cuff-based manometry device. Sci. Rep. 10, 16116 (2020).","journal-title":"Sci. Rep."},{"key":"1403_CR142","doi-asserted-by":"publisher","DOI":"10.3389\/fmed.2021.693926","volume":"8","author":"E Kachel","year":"2021","unstructured":"Kachel, E. et al. A pilot study of blood pressure monitoring after cardiac surgery using a wearable, non-invasive sensor. Front. Med. 8, 693926 (2021).","journal-title":"Front. Med."},{"key":"1403_CR143","doi-asserted-by":"publisher","first-page":"8","DOI":"10.3390\/jcm10010008","volume":"10","author":"Y Atzmon","year":"2020","unstructured":"Atzmon, Y. et al. Continuous maternal hemodynamics monitoring at delivery using a novel, noninvasive, wireless, PPG-based sensor. J. Clin. Med. 10, 8 (2020).","journal-title":"J. Clin. Med."},{"key":"1403_CR144","doi-asserted-by":"publisher","first-page":"126","DOI":"10.3390\/bios11040126","volume":"11","author":"J Fine","year":"2021","unstructured":"Fine, J. et al. Sources of inaccuracy in photoplethysmography for continuous cardiovascular monitoring. Biosensors 11, 126 (2021).","journal-title":"Biosensors"},{"key":"1403_CR145","doi-asserted-by":"publisher","first-page":"2251","DOI":"10.1038\/s41440-023-01344-5","volume":"46","author":"PA Tsioufis","year":"2023","unstructured":"Tsioufis, P. A., Iliakis, P., Konstantinidis, D., Dimitriadis, K. & Tsioufis, K. 7-day Aktiia bracelet vs 24\u2009h ABPM study: more questions than answers? Hypertens. Res. 46, 2251\u20132253 (2023).","journal-title":"Hypertens. Res."},{"key":"1403_CR146","doi-asserted-by":"publisher","first-page":"899","DOI":"10.1038\/s41570-022-00439-w","volume":"6","author":"JR Sempionatto","year":"2022","unstructured":"Sempionatto, J. R., Lasalde-Ramirez, J. A., Mahato, K., Wang, J. & Gao, W. Wearable chemical sensors for biomarker discovery in the omics era. Nat. Rev. Chem. 6, 899\u2013915 (2022).","journal-title":"Nat. Rev. Chem."},{"key":"1403_CR147","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1038\/s41378-022-00443-6","volume":"9","author":"F Gao","year":"2023","unstructured":"Gao, F. et al. Wearable and flexible electrochemical sensors for sweat analysis: a review. Microsyst. Nanoeng. 9, 1 (2023).","journal-title":"Microsyst. Nanoeng."},{"key":"1403_CR148","doi-asserted-by":"publisher","first-page":"eabd8109","DOI":"10.1126\/scitranslmed.abd8109","volume":"13","author":"TR Ray","year":"2021","unstructured":"Ray, T. R. et al. Soft, skin-interfaced sweat stickers for cystic fibrosis diagnosis and management. Sci. Transl. Med. 13, eabd8109 (2021).","journal-title":"Sci. Transl. Med."},{"key":"1403_CR149","doi-asserted-by":"publisher","first-page":"3750","DOI":"10.1039\/C8LC01082J","volume":"18","author":"A Hauke","year":"2018","unstructured":"Hauke, A. et al. Complete validation of a continuous and blood-correlated sweat biosensing device with integrated sweat stimulation. Lab. Chip 18, 3750\u20133759 (2018).","journal-title":"Lab. Chip"},{"key":"1403_CR150","doi-asserted-by":"publisher","DOI":"10.1002\/admt.202000910","volume":"6","author":"B Paul","year":"2021","unstructured":"Paul, B., Demuru, S., Lafaye, C., Saubade, M. & Briand, D. Printed iontophoretic-integrated wearable microfluidic sweat-sensing patch for on-demand point-of-care sweat analysis. Adv. Mater. Technol. 6, 2000910 (2021).","journal-title":"Adv. Mater. Technol."},{"key":"1403_CR151","doi-asserted-by":"publisher","first-page":"5411","DOI":"10.1007\/s00216-021-03865-9","volume":"414","author":"G Bolat","year":"2022","unstructured":"Bolat, G. et al. Wearable soft electrochemical microfluidic device integrated with iontophoresis for sweat biosensing. Anal. Bioanal. Chem. 414, 5411\u20135421 (2022).","journal-title":"Anal. Bioanal. Chem."},{"key":"1403_CR152","doi-asserted-by":"publisher","first-page":"504","DOI":"10.1038\/s41565-018-0112-4","volume":"13","author":"L Lipani","year":"2018","unstructured":"Lipani, L. et al. Non-invasive, transdermal, path-selective and specific glucose monitoring via a graphene-based platform. Nat. Nanotechnol. 13, 504\u2013511 (2018).","journal-title":"Nat. Nanotechnol."},{"key":"1403_CR153","doi-asserted-by":"publisher","DOI":"10.1126\/sciadv.1701629","volume":"3","author":"Y Chen","year":"2017","unstructured":"Chen, Y. et al. Skin-like biosensor system via electrochemical channels for noninvasive blood glucose monitoring. Sci. Adv. 3, e1701629 (2017).","journal-title":"Sci. Adv."},{"key":"1403_CR154","doi-asserted-by":"publisher","first-page":"eabd0199","DOI":"10.1126\/sciadv.abd0199","volume":"7","author":"Z Pu","year":"2021","unstructured":"Pu, Z. et al. A thermal activated and differential self-calibrated flexible epidermal biomicrofluidic device for wearable accurate blood glucose monitoring. Sci. Adv. 7, eabd0199 (2021).","journal-title":"Sci. Adv."},{"key":"1403_CR155","doi-asserted-by":"publisher","DOI":"10.1002\/adhm.202002255","volume":"10","author":"H Teymourian","year":"2021","unstructured":"Teymourian, H., Tehrani, F., Mahato, K. & Wang, J. Lab under the skin: microneedle based wearable devices. Adv. Healthc. Mater. 10, e2002255 (2021).","journal-title":"Adv. Healthc. Mater."},{"key":"1403_CR156","doi-asserted-by":"publisher","first-page":"1578","DOI":"10.1021\/acs.analchem.8b04877","volume":"91","author":"M Parrilla","year":"2019","unstructured":"Parrilla, M. et al. Wearable all-solid-state potentiometric microneedle patch for intradermal potassium detection. Anal. Chem. 91, 1578\u20131586 (2019).","journal-title":"Anal. Chem."},{"key":"1403_CR157","doi-asserted-by":"publisher","first-page":"876","DOI":"10.1002\/adhm.201300541","volume":"3","author":"PR Miller","year":"2014","unstructured":"Miller, P. R. et al. Microneedle-based transdermal sensor for on-chip potentiometric determination of K+. Adv. Healthc. Mater. 3, 876\u2013881 (2014).","journal-title":"Adv. Healthc. Mater."},{"key":"1403_CR158","doi-asserted-by":"publisher","first-page":"739","DOI":"10.1016\/j.talanta.2011.11.046","volume":"88","author":"PR Miller","year":"2012","unstructured":"Miller, P. R. et al. Multiplexed microneedle-based biosensor array for characterization of metabolic acidosis. Talanta 88, 739\u2013742 (2012).","journal-title":"Talanta"},{"key":"1403_CR159","doi-asserted-by":"publisher","DOI":"10.1007\/s10544-018-0349-6","volume":"20","author":"F Ribet","year":"2018","unstructured":"Ribet, F., Stemme, G. & Roxhed, N. Real-time intradermal continuous glucose monitoring using a minimally invasive microneedle-based system. Biomed. Microdevices 20, 101 (2018).","journal-title":"Biomed. Microdevices"},{"key":"1403_CR160","doi-asserted-by":"publisher","first-page":"2088","DOI":"10.1039\/C8AY00264A","volume":"10","author":"S Sharma","year":"2018","unstructured":"Sharma, S. et al. A pilot study in humans of microneedle sensor arrays for continuous glucose monitoring. Anal. Methods 10, 2088\u20132095 (2018).","journal-title":"Anal. Methods"},{"key":"1403_CR161","doi-asserted-by":"publisher","first-page":"574","DOI":"10.1016\/j.bios.2017.01.016","volume":"91","author":"AMV Mohan","year":"2017","unstructured":"Mohan, A. M. V., Windmiller, J. R., Mishra, R. K. & Wang, J. Continuous minimally-invasive alcohol monitoring using microneedle sensor arrays. Biosens. Bioelectron. 91, 574\u2013579 (2017).","journal-title":"Biosens. Bioelectron."},{"key":"1403_CR162","doi-asserted-by":"publisher","first-page":"2302","DOI":"10.1002\/elan.201100361","volume":"23","author":"JR Windmiller","year":"2011","unstructured":"Windmiller, J. R. et al. Bicomponent microneedle array biosensor for minimally-invasive glutamate monitoring. Electroanalysis 23, 2302\u20132309 (2011).","journal-title":"Electroanalysis"},{"key":"1403_CR163","doi-asserted-by":"publisher","first-page":"1846","DOI":"10.1039\/c1an00012h","volume":"136","author":"JR Windmiller","year":"2011","unstructured":"Windmiller, J. R. et al. Microneedle array-based carbon paste amperometric sensors and biosensors. Analyst 136, 1846\u20131851 (2011).","journal-title":"Analyst"},{"key":"1403_CR164","doi-asserted-by":"publisher","first-page":"152","DOI":"10.1016\/j.bios.2018.08.010","volume":"123","author":"P Bollella","year":"2019","unstructured":"Bollella, P., Sharma, S., Cass, A. E. G. & Antiochia, R. Microneedle-based biosensor for minimally-invasive lactate detection. Biosens. Bioelectron. 123, 152\u2013159 (2019).","journal-title":"Biosens. Bioelectron."},{"key":"1403_CR165","doi-asserted-by":"publisher","first-page":"104","DOI":"10.1016\/j.sbsr.2016.10.004","volume":"13","author":"S Sharma","year":"2017","unstructured":"Sharma, S., Saeed, A., Johnson, C., Gadegaard, N. & Cass, A. E. Rapid, low cost prototyping of transdermal devices for personal healthcare monitoring. Sens. Biosensing Res. 13, 104\u2013108 (2017).","journal-title":"Sens. Biosensing Res."},{"key":"1403_CR166","doi-asserted-by":"publisher","first-page":"2291","DOI":"10.1021\/acs.analchem.9b05109","volume":"92","author":"H Teymourian","year":"2020","unstructured":"Teymourian, H. et al. Microneedle-based detection of ketone bodies along with glucose and lactate: toward real-time continuous interstitial fluid monitoring of diabetic ketosis and ketoacidosis. Anal. Chem. 92, 2291\u20132300 (2020).","journal-title":"Anal. Chem."},{"key":"1403_CR167","doi-asserted-by":"publisher","first-page":"2196","DOI":"10.1021\/acssensors.9b01127","volume":"4","author":"KY Goud","year":"2019","unstructured":"Goud, K. Y. et al. Wearable electrochemical microneedle sensor for continuous monitoring of levodopa: toward Parkinson management. ACS Sens. 4, 2196\u20132204 (2019).","journal-title":"ACS Sens."},{"key":"1403_CR168","doi-asserted-by":"publisher","DOI":"10.1002\/adhm.201701264","volume":"7","author":"B Ciui","year":"2018","unstructured":"Ciui, B. et al. Wearable wireless tyrosinase bandage and microneedle sensors: toward melanoma screening. Adv. Healthc. Mater. 7, e1701264 (2018).","journal-title":"Adv. Healthc. Mater."},{"key":"1403_CR169","doi-asserted-by":"publisher","first-page":"64","DOI":"10.1038\/s41551-020-00672-y","volume":"5","author":"Z Wang","year":"2021","unstructured":"Wang, Z. et al. Microneedle patch for the ultrasensitive quantification of protein biomarkers in interstitial fluid. Nat. Biomed. Eng. 5, 64\u201376 (2021).","journal-title":"Nat. Biomed. Eng."},{"key":"1403_CR170","doi-asserted-by":"publisher","first-page":"366ra165","DOI":"10.1126\/scitranslmed.aaf2593","volume":"8","author":"A Koh","year":"2016","unstructured":"Koh, A. et al. A soft, wearable microfluidic device for the capture, storage, and colorimetric sensing of sweat. Sci. Transl. Med. 8, 366ra165 (2016).","journal-title":"Sci. Transl. Med."},{"key":"1403_CR171","doi-asserted-by":"publisher","first-page":"944","DOI":"10.1021\/acssensors.7b00961","volume":"3","author":"HYY Nyein","year":"2018","unstructured":"Nyein, H. Y. Y. et al. A wearable microfluidic sensing patch for dynamic sweat secretion analysis. ACS Sens. 3, 944\u2013952 (2018).","journal-title":"ACS Sens."},{"key":"1403_CR172","doi-asserted-by":"publisher","first-page":"405","DOI":"10.3390\/bios11100405","volume":"11","author":"S Wang","year":"2021","unstructured":"Wang, S. et al. A review of capillary pressure control valves in microfluidics. Biosensors 11, 405 (2021).","journal-title":"Biosensors"},{"key":"1403_CR173","doi-asserted-by":"publisher","unstructured":"Choi, J., Kang, D., Han, S., Kim, S. B. & Rogers, J. A. Thin, soft, skin-mounted microfluidic networks with capillary bursting valves for chrono-sampling of sweat. Adv. Healthc. Mater. https:\/\/doi.org\/10.1002\/adhm.201601355 (2017).","DOI":"10.1002\/adhm.201601355"},{"key":"1403_CR174","doi-asserted-by":"publisher","first-page":"84","DOI":"10.1039\/C9LC01045A","volume":"20","author":"SB Kim","year":"2020","unstructured":"Kim, S. B. et al. Soft, skin-interfaced microfluidic systems with integrated enzymatic assays for measuring the concentration of ammonia and ethanol in sweat. Lab. Chip 20, 84\u201392 (2020).","journal-title":"Lab. Chip"},{"key":"1403_CR175","doi-asserted-by":"publisher","first-page":"27906","DOI":"10.1073\/pnas.2012700117","volume":"117","author":"S Kim","year":"2020","unstructured":"Kim, S. et al. Soft, skin-interfaced microfluidic systems with integrated immunoassays, fluorometric sensors, and impedance measurement capabilities. Proc. Natl Acad. Sci. USA 117, 27906\u201327915 (2020).","journal-title":"Proc. Natl Acad. Sci. USA"},{"key":"1403_CR176","doi-asserted-by":"publisher","first-page":"eabe3929","DOI":"10.1126\/sciadv.abe3929","volume":"6","author":"LB Baker","year":"2020","unstructured":"Baker, L. B. et al. Skin-interfaced microfluidic system with personalized sweating rate and sweat chloride analytics for sports science applications. Sci. Adv. 6, eabe3929 (2020).","journal-title":"Sci. Adv."},{"key":"1403_CR177","doi-asserted-by":"publisher","DOI":"10.1002\/adhm.202000722","volume":"10","author":"J Choi","year":"2021","unstructured":"Choi, J. et al. Skin-interfaced microfluidic systems that combine hard and soft materials for demanding applications in sweat capture and analysis. Adv. Healthc. Mater. 10, e2000722 (2021).","journal-title":"Adv. Healthc. Mater."},{"key":"1403_CR178","doi-asserted-by":"publisher","first-page":"42","DOI":"10.1016\/j.coelec.2020.03.008","volume":"23","author":"H Liu","year":"2020","unstructured":"Liu, H. & Zhao, C. Wearable electrochemical sensors for noninvasive monitoring of health\u2014a perspective. Curr. Opin. Electrochem. 23, 42\u201346 (2020).","journal-title":"Curr. Opin. Electrochem."},{"key":"1403_CR179","doi-asserted-by":"publisher","DOI":"10.1016\/j.bios.2020.112750","volume":"172","author":"J Min","year":"2021","unstructured":"Min, J., Sempionatto, J. R., Teymourian, H., Wang, J. & Gao, W. Wearable electrochemical biosensors in North America. Biosens. Bioelectron. 172, 112750 (2021).","journal-title":"Biosens. Bioelectron."},{"key":"1403_CR180","doi-asserted-by":"publisher","first-page":"2823","DOI":"10.1021\/acssensors.2c01428","volume":"7","author":"AM Downs","year":"2022","unstructured":"Downs, A. M. & Plaxco, K. W. Real-time, in vivo molecular monitoring using electrochemical aptamer based sensors: opportunities and challenges. ACS Sens. 7, 2823\u20132832 (2022).","journal-title":"ACS Sens."},{"key":"1403_CR181","doi-asserted-by":"publisher","DOI":"10.1126\/sciadv.abk0967","volume":"8","author":"B Wang","year":"2022","unstructured":"Wang, B. et al. Wearable aptamer-field-effect transistor sensing system for noninvasive cortisol monitoring. Sci. Adv. 8, eabk0967 (2022).","journal-title":"Sci. Adv."},{"key":"1403_CR182","doi-asserted-by":"publisher","DOI":"10.1016\/j.bios.2023.115097","volume":"227","author":"NK Singh","year":"2023","unstructured":"Singh, N. K., Chung, S., Chang, A. Y., Wang, J. & Hall, D. A. A non-invasive wearable stress patch for real-time cortisol monitoring using a pseudoknot-assisted aptamer. Biosens. Bioelectron. 227, 115097 (2023).","journal-title":"Biosens. Bioelectron."},{"key":"1403_CR183","doi-asserted-by":"publisher","first-page":"330","DOI":"10.1038\/s41565-023-01513-0","volume":"19","author":"C Ye","year":"2024","unstructured":"Ye, C. et al. A wearable aptamer nanobiosensor for non-invasive female hormone monitoring. Nat. Nanotechnol. 19, 330\u2013337 (2024).","journal-title":"Nat. Nanotechnol."},{"key":"1403_CR184","doi-asserted-by":"publisher","DOI":"10.1126\/sciadv.abq4539","volume":"8","author":"S Lin","year":"2022","unstructured":"Lin, S. et al. Wearable microneedle-based electrochemical aptamer biosensing for precision dosing of drugs with narrow therapeutic windows. Sci. Adv. 8, eabq4539 (2022).","journal-title":"Sci. Adv."},{"key":"1403_CR185","doi-asserted-by":"publisher","first-page":"631","DOI":"10.1016\/S0956-5663(01)00191-9","volume":"16","author":"S Subrahmanyam","year":"2001","unstructured":"Subrahmanyam, S. et al. \u201cBite-and-Switch\u201d approach using computationally designed molecularly imprinted polymers for sensing of creatinine. Biosens. Bioelectron. 16, 631\u2013637 (2001).","journal-title":"Biosens. Bioelectron."},{"key":"1403_CR186","doi-asserted-by":"publisher","DOI":"10.1016\/j.greeac.2023.100069","volume":"6","author":"S Fang","year":"2023","unstructured":"Fang, S. et al. Recent developments on solid phase microextraction (SPME) coatings for in vivo analysis. Green. Anal. Chem. 6, 100069 (2023).","journal-title":"Green. Anal. Chem."},{"key":"1403_CR187","doi-asserted-by":"publisher","first-page":"1225","DOI":"10.1038\/s41551-022-00916-z","volume":"6","author":"M Wang","year":"2022","unstructured":"Wang, M. et al. A wearable electrochemical biosensor for the monitoring of metabolites and nutrients. Nat. Biomed. Eng. 6, 1225\u20131235 (2022).","journal-title":"Nat. Biomed. Eng."},{"key":"1403_CR188","doi-asserted-by":"publisher","first-page":"17767","DOI":"10.1021\/jacs.3c04458","volume":"145","author":"DH Lee","year":"2023","unstructured":"Lee, D. H., Lee, W. Y. & Kim, J. Introducing nanoscale electrochemistry in small-molecule detection for tackling existing limitations of affinity-based label-free biosensing applications. J. Am. Chem. Soc. 145, 17767\u201317778 (2023).","journal-title":"J. Am. Chem. Soc."},{"key":"1403_CR189","first-page":"91","volume":"13","author":"MJ Saikia","year":"2019","unstructured":"Saikia, M. J., Besio, W. G. & Mankodiya, K. WearLight: toward a wearable, configurable functional nir spectroscopy system for noninvasive neuroimaging. IEEE Trans. Biomed. Circuits Syst. 13, 91\u2013102 (2019).","journal-title":"IEEE Trans. Biomed. Circuits Syst."},{"key":"1403_CR190","doi-asserted-by":"publisher","first-page":"128114","DOI":"10.1109\/ACCESS.2019.2939798","volume":"7","author":"Y Khan","year":"2019","unstructured":"Khan, Y. et al. Organic multi-channel optoelectronic sensors for wearable health monitoring. IEEE Access. 7, 128114\u2013128124 (2019).","journal-title":"IEEE Access."},{"key":"1403_CR191","doi-asserted-by":"publisher","first-page":"173","DOI":"10.1016\/j.snb.2019.01.121","volume":"286","author":"VP Rachim","year":"2019","unstructured":"Rachim, V. P. & Chung, W.-Y. Wearable-band type visible-near infrared optical biosensor for non-invasive blood glucose monitoring. Sens. Actuators B: Chem. 286, 173\u2013180 (2019).","journal-title":"Sens. Actuators B: Chem."},{"key":"1403_CR192","doi-asserted-by":"publisher","first-page":"42","DOI":"10.1038\/s43856-022-00104-9","volume":"2","author":"J Titus","year":"2022","unstructured":"Titus, J. et al. Development and preliminary validation of infrared spectroscopic device for transdermal assessment of elevated cardiac troponin. Commun. Med. 2, 42 (2022).","journal-title":"Commun. Med."},{"key":"1403_CR193","doi-asserted-by":"publisher","first-page":"145","DOI":"10.1093\/ehjdh\/ztad015","volume":"4","author":"S Sengupta","year":"2023","unstructured":"Sengupta, S. et al. A novel breakthrough in wrist-worn transdermal troponin-I-sensor assessment for acute myocardial infarction. Eur. Heart J. Digit. Health 4, 145\u2013154 (2023).","journal-title":"Eur. Heart J. Digit. Health"},{"key":"1403_CR194","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1109\/JSTQE.2019.2911432","volume":"25","author":"AJ Zilkie","year":"2019","unstructured":"Zilkie, A. J. et al. Multi-micron silicon photonics platform for highly manufacturable and versatile photonic integrated circuits. IEEE J. Sel. Top. Quantum Electron. 25, 1\u201313 (2019).","journal-title":"IEEE J. Sel. Top. Quantum Electron."},{"key":"1403_CR195","unstructured":"Rockley Photonics. Real-time, non-invasive biomarker sensing on the wrist. How integrated photonics will revolutionize mobile biomarker monitoring. rockleyphotonics.com https:\/\/rockleyphotonics.com\/wp-content\/uploads\/2021\/07\/Rockley-Photonics-Biomarker-Sensing-on-the-Wrist.pdf (2021)."},{"key":"1403_CR196","doi-asserted-by":"crossref","unstructured":"Bohman, A. B., Nguyen, J. Q., Parthasarathy, S. & Arnold, M. A. Temperature and hydration monitoring in tissue-simulating phantoms using novel silicon-photonics-based spectrophotometer. In Biophotonics in Exercise Science, Sports Medicine, Health Monitoring Technologies, and Wearables IV (eds Hyatt, C. J., Drexler, W. & Roberts, M. S.) 1237506 (SPIE, 2023).","DOI":"10.1117\/12.2649262"},{"key":"1403_CR197","doi-asserted-by":"publisher","DOI":"10.1038\/s41377-022-01006-0","volume":"12","author":"J Yang","year":"2023","unstructured":"Yang, J., Tang, M., Chen, S. & Liu, H. From past to future: on-chip laser sources for photonic integrated circuits. Light. Sci. Appl. 12, 16 (2023).","journal-title":"Light. Sci. Appl."},{"key":"1403_CR198","doi-asserted-by":"publisher","first-page":"850","DOI":"10.1038\/s41578-022-00427-y","volume":"7","author":"M Lin","year":"2022","unstructured":"Lin, M., Hu, H., Zhou, S. & Xu, S. Soft wearable devices for deep-tissue sensing. Nat. Rev. Mater. 7, 850\u2013869 (2022).","journal-title":"Nat. Rev. Mater."},{"key":"1403_CR199","doi-asserted-by":"crossref","unstructured":"AlMohimeed, I., Turkistani, H. & Ono, Y. Development of wearable and flexible ultrasonic sensor for skeletal muscle monitoring. In 2013 IEEE International Ultrasonics Symposium (IUS) (eds Berg, S. v. d. & Vos, H. J.) 1137\u20131140 (IEEE, 2013).","DOI":"10.1109\/ULTSYM.2013.0291"},{"key":"1403_CR200","doi-asserted-by":"publisher","DOI":"10.1126\/sciadv.adk8426","volume":"10","author":"HC Liu","year":"2024","unstructured":"Liu, H. C. et al. Wearable bioadhesive ultrasound shear wave elastography. Sci. Adv. 10, eadk8426 (2024).","journal-title":"Sci. Adv."},{"key":"1403_CR201","doi-asserted-by":"publisher","first-page":"517","DOI":"10.1126\/science.abo2542","volume":"377","author":"C Wang","year":"2022","unstructured":"Wang, C. et al. Bioadhesive ultrasound for long-term continuous imaging of diverse organs. Science 377, 517\u2013523 (2022).","journal-title":"Science"},{"key":"1403_CR202","doi-asserted-by":"publisher","DOI":"10.1126\/sciadv.aar3979","volume":"4","author":"H Hu","year":"2018","unstructured":"Hu, H. et al. Stretchable ultrasonic transducer arrays for three-dimensional imaging on complex surfaces. Sci. Adv. 4, eaar3979 (2018).","journal-title":"Sci. Adv."},{"key":"1403_CR203","doi-asserted-by":"publisher","first-page":"687","DOI":"10.1038\/s41551-018-0287-x","volume":"2","author":"C Wang","year":"2018","unstructured":"Wang, C. et al. Monitoring of the central blood pressure waveform via a conformal ultrasonic device. Nat. Biomed. Eng. 2, 687\u2013695 (2018).","journal-title":"Nat. Biomed. Eng."},{"key":"1403_CR204","doi-asserted-by":"publisher","first-page":"749","DOI":"10.1038\/s41551-021-00763-4","volume":"5","author":"C Wang","year":"2021","unstructured":"Wang, C. et al. Continuous monitoring of deep-tissue haemodynamics with stretchable ultrasonic phased arrays. Nat. Biomed. Eng. 5, 749\u2013758 (2021).","journal-title":"Nat. Biomed. Eng."},{"key":"1403_CR205","doi-asserted-by":"publisher","first-page":"737","DOI":"10.1038\/s41551-021-00685-1","volume":"5","author":"JR Sempionatto","year":"2021","unstructured":"Sempionatto, J. R. et al. An epidermal patch for the simultaneous monitoring of haemodynamic and metabolic biomarkers. Nat. Biomed. Eng. 5, 737\u2013748 (2021).","journal-title":"Nat. Biomed. Eng."},{"key":"1403_CR206","doi-asserted-by":"publisher","first-page":"1321","DOI":"10.1038\/s41551-023-01038-w","volume":"7","author":"H Hu","year":"2023","unstructured":"Hu, H. et al. Stretchable ultrasonic arrays for the three-dimensional mapping of the modulus of deep tissue. Nat. Biomed. Eng. 7, 1321\u20131334 (2023).","journal-title":"Nat. Biomed. Eng."},{"key":"1403_CR207","doi-asserted-by":"publisher","first-page":"448","DOI":"10.1038\/s41587-023-01800-0","volume":"42","author":"M Lin","year":"2024","unstructured":"Lin, M. et al. A fully integrated wearable ultrasound system to monitor deep tissues in moving subjects. Nat. Biotechnol. 42, 448\u2013457 (2024).","journal-title":"Nat. Biotechnol."},{"key":"1403_CR208","doi-asserted-by":"publisher","DOI":"10.1126\/sciadv.adh5325","volume":"9","author":"W Du","year":"2023","unstructured":"Du, W. et al. Conformable ultrasound breast patch for deep tissue scanning and imaging. Sci. Adv. 9, eadh5325 (2023).","journal-title":"Sci. Adv."},{"key":"1403_CR209","doi-asserted-by":"publisher","first-page":"77","DOI":"10.1038\/s41928-023-01068-x","volume":"7","author":"L Zhang","year":"2024","unstructured":"Zhang, L. et al. A conformable phased-array ultrasound patch for bladder volume monitoring. Nat. Electron. 7, 77\u201390 (2024).","journal-title":"Nat. Electron."},{"key":"1403_CR210","doi-asserted-by":"publisher","first-page":"311","DOI":"10.1016\/j.comcom.2020.02.018","volume":"153","author":"JJ Hathaliya","year":"2020","unstructured":"Hathaliya, J. J. & Tanwar, S. An exhaustive survey on security and privacy issues in Healthcare 4.0. Computer Commun. 153, 311\u2013335 (2020).","journal-title":"Computer Commun."},{"key":"1403_CR211","doi-asserted-by":"publisher","first-page":"169","DOI":"10.1016\/j.glohj.2021.11.008","volume":"5","author":"E Mbunge","year":"2021","unstructured":"Mbunge, E., Muchemwa, B., Jiyane, S. & Batani, J. Sensors and Healthcare 5.0: transformative shift in virtual care through emerging digital health technologies. Glob. Health J. 5, 169\u2013177 (2021).","journal-title":"Glob. Health J."},{"key":"1403_CR212","doi-asserted-by":"publisher","DOI":"10.1016\/j.lanhl.2025.100725","author":"JK Lu","year":"2025","unstructured":"Lu, J. K. et al. Digital biomarkers of ageing for monitoring physiological systems in community-dwelling adults. Lancet Healthy Longev. https:\/\/doi.org\/10.1016\/j.lanhl.2025.100725 (2025).","journal-title":"Lancet Healthy Longev."},{"key":"1403_CR213","doi-asserted-by":"publisher","DOI":"10.1038\/s41746-023-00790-2","volume":"6","author":"S Colloud","year":"2023","unstructured":"Colloud, S. et al. Evolving regulatory perspectives on digital health technologies for medicinal product development. npj Digital Med. 6, 56 (2023).","journal-title":"npj Digital Med."},{"key":"1403_CR214","doi-asserted-by":"publisher","DOI":"10.1016\/j.bios.2023.115983","volume":"248","author":"N Zavanelli","year":"2024","unstructured":"Zavanelli, N., Lee, S. H., Guess, M. & Yeo, W. H. Continuous real-time assessment of acute cognitive stress from cardiac mechanical signals captured by a skin-like patch. Biosens. Bioelectron. 248, 115983 (2024).","journal-title":"Biosens. Bioelectron."},{"key":"1403_CR215","doi-asserted-by":"publisher","DOI":"10.1002\/adfm.202100852","volume":"31","author":"G Xu","year":"2021","unstructured":"Xu, G. et al. Battery-free and wireless smart wound dressing for wound infection monitoring and electrically controlled on-demand drug delivery. Adv. Funct. Mater. 31, 2100852 (2021).","journal-title":"Adv. Funct. Mater."},{"key":"1403_CR216","doi-asserted-by":"publisher","first-page":"175","DOI":"10.1002\/adhm.201500357","volume":"5","author":"S Bagherifard","year":"2016","unstructured":"Bagherifard, S. et al. Dermal patch with integrated flexible heater for on demand drug delivery. Adv. Healthc. Mater. 5, 175\u2013184 (2016).","journal-title":"Adv. Healthc. Mater."}],"container-title":["Nature Reviews Drug Discovery"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.nature.com\/articles\/s41573-026-01403-9.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.nature.com\/articles\/s41573-026-01403-9","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.nature.com\/articles\/s41573-026-01403-9.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,6,5]],"date-time":"2026-06-05T12:04:15Z","timestamp":1780661055000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.nature.com\/articles\/s41573-026-01403-9"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,3,23]]},"references-count":216,"journal-issue":{"issue":"6","published-print":{"date-parts":[[2026,6]]}},"alternative-id":["1403"],"URL":"https:\/\/doi.org\/10.1038\/s41573-026-01403-9","relation":{},"ISSN":["1474-1776","1474-1784"],"issn-type":[{"value":"1474-1776","type":"print"},{"value":"1474-1784","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,3,23]]},"assertion":[{"value":"18 February 2026","order":1,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"23 March 2026","order":2,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"Z.A.F. is a paid consultant to Rockley Photonics. R.P.H. is on the advisory board for Bristol Myers Squibb.\u00a0R.P.H. reports consulting from Bristol Meyers Squibb, Abbvie, stock options from Salvo Health, research support from Janssen, Intralytix, Enlisense, Crohn\u2019s and Colitis Foundation.","order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}]}}