{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,23]],"date-time":"2026-09-23T23:59:27Z","timestamp":1790207967420,"version":"4.1.0"},"reference-count":107,"publisher":"Springer Science and Business Media LLC","license":[{"start":{"date-parts":[[2026,9,23]],"date-time":"2026-09-23T00:00:00Z","timestamp":1790121600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.springernature.com\/gp\/researchers\/text-and-data-mining"},{"start":{"date-parts":[[2026,9,23]],"date-time":"2026-09-23T00:00:00Z","timestamp":1790121600000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/www.springernature.com\/gp\/researchers\/text-and-data-mining"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Nat Rev Urol"],"DOI":"10.1038\/s41585-026-01186-z","type":"journal-article","created":{"date-parts":[[2026,9,23]],"date-time":"2026-09-23T16:02:15Z","timestamp":1790179335000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":0,"title":["The potential of soft robotics for the restoration of urinary voiding"],"prefix":"10.1038","author":[{"ORCID":"https:\/\/orcid.org\/0009-0007-3583-0468","authenticated-orcid":false,"given":"Yongqi","family":"Zhang","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Eric M.","family":"Yeatman","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ranan","family":"Dasgupta","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2026,9,23]]},"reference":[{"key":"1186_CR1","doi-asserted-by":"publisher","first-page":"453","DOI":"10.1038\/nrn2401","volume":"9","author":"CJ Fowler","year":"2008","unstructured":"Fowler, C. J., Griffiths, D. & de Groat, W. C. The neural control of micturition. Nat. Rev. Neurosci. 9, 453\u2013466 (2008).","journal-title":"Nat. Rev. Neurosci."},{"key":"1186_CR2","doi-asserted-by":"publisher","first-page":"37","DOI":"10.1016\/S0090-4295(02)02243-4","volume":"61","author":"P Abrams","year":"2003","unstructured":"Abrams, P. et al. Standardisation of LUT function terminology. Urology 61, 37\u201349 (2003).","journal-title":"Urology"},{"key":"1186_CR3","doi-asserted-by":"publisher","first-page":"461","DOI":"10.1002\/nau.24583","volume":"40","author":"S Gandhi","year":"2021","unstructured":"Gandhi, S. et al. Long-term outcomes of sacral neuromodulation. Neurourol. Urodyn. 40, 461\u2013469 (2021).","journal-title":"Neurourol. Urodyn."},{"key":"1186_CR4","doi-asserted-by":"publisher","DOI":"10.1002\/aisy.202500516","volume":"8","author":"I Tamadon","year":"2026","unstructured":"Tamadon, I., Ibrahimi, M., Semproni, F., Iacovacci, V. & Menciassi, A. A robotic urinary bladder enabling volume monitoring and assisted micturition. Adv. Intell. Syst. 8, e202500516 (2026).","journal-title":"Adv. Intell. Syst."},{"key":"1186_CR5","doi-asserted-by":"publisher","DOI":"10.1126\/sciadv.abq1456","volume":"8","author":"Y Yang","year":"2022","unstructured":"Yang, Y. et al. Magnetic soft robotic bladder for assisted urination. Sci. Adv. 8, eabq1456 (2022).","journal-title":"Sci. Adv."},{"key":"1186_CR6","doi-asserted-by":"publisher","DOI":"10.1038\/s41528-025-00401-y","volume":"9","author":"Q Hu","year":"2025","unstructured":"Hu, Q., Wu, Z. & Zang, J. Magnetic soft robotic system for intelligent bladder volume control. NPJ Flex. Electron. 9, 401 (2025).","journal-title":"NPJ Flex. Electron."},{"key":"1186_CR7","doi-asserted-by":"publisher","first-page":"1366","DOI":"10.1001\/jama.2016.14617","volume":"316","author":"CL Amundsen","year":"2016","unstructured":"Amundsen, C. L. et al. OnabotulinumtoxinA vs sacral neuromodulation for refractory urgency incontinence (ROSETTA trial). JAMA 316, 1366\u20131374 (2016).","journal-title":"JAMA"},{"key":"1186_CR8","doi-asserted-by":"publisher","DOI":"10.3390\/medicina60030509","volume":"60","author":"M Spilotros","year":"2024","unstructured":"Spilotros, M. et al. Sacral neuromodulation \u2013 device and practice. Medicina 60, 509 (2024).","journal-title":"Medicina"},{"key":"1186_CR9","doi-asserted-by":"publisher","DOI":"10.1063\/5.0278500","volume":"9","author":"F Semproni","year":"2025","unstructured":"Semproni, F. et al. A fully implantable sensorized artificial urinary bladder to restore continence and fullness monitoring. APL. Bioeng. 9, 036114 (2025).","journal-title":"APL. Bioeng."},{"key":"1186_CR10","doi-asserted-by":"crossref","first-page":"431","DOI":"10.1177\/2051415814531575","volume":"9","author":"C Morli\u00e8re","year":"2016","unstructured":"Morli\u00e8re, C. et al. Cost-utility of sacral anterior root stimulation (Brindley procedure). J. Clin. Urol. 9, 431\u2013438 (2016).","journal-title":"J. Clin. Urol."},{"key":"1186_CR11","doi-asserted-by":"crossref","first-page":"312","DOI":"10.4103\/0970-1591.56179","volume":"25","author":"S Krishnamoorthy","year":"2009","unstructured":"Krishnamoorthy, S. & Bhat, S. Detrusor underactivity: to tone or not to tone? Indian J. Urol. 25, 312\u2013317 (2009).","journal-title":"Indian J. Urol."},{"key":"1186_CR12","doi-asserted-by":"publisher","first-page":"1","DOI":"10.5213\/inj.2448134.067","volume":"28","author":"B Uvelius","year":"2024","unstructured":"Uvelius, B. & Andersson, K.-E. Can bladder innervation be restored? Int. Neurourol. J. 28, 1\u201316 (2024).","journal-title":"Int. Neurourol. J."},{"key":"1186_CR13","doi-asserted-by":"publisher","first-page":"22","DOI":"10.1111\/bju.13598","volume":"119","author":"MJ Drake","year":"2017","unstructured":"Drake, M. J. et al. The potential role of unregulated autonomous bladder micromotions in urinary storage and voiding dysfunction; overactive bladder and detrusor underactivity. BJU Int. 119, 22\u201329 (2017).","journal-title":"BJU Int."},{"key":"1186_CR14","doi-asserted-by":"publisher","first-page":"1567","DOI":"10.1002\/nau.23504","volume":"37","author":"M Choudhary","year":"2018","unstructured":"Choudhary, M., van Mastrigt, R. & van Asselt, E. The frequency spectrum of bladder non-voiding activity as a trigger-event for conditional stimulation: closed-loop inhibition of bladder contractions in rats. Neurourol. Urodyn. 37, 1567\u20131573 (2018).","journal-title":"Neurourol. Urodyn."},{"key":"1186_CR15","doi-asserted-by":"publisher","first-page":"93","DOI":"10.1111\/apha.12019","volume":"207","author":"DJ Griffiths","year":"2013","unstructured":"Griffiths, D. J. & Fowler, C. J. The micturition switch and its forebrain influences. Acta Physiol. 207, 93\u2013109 (2013).","journal-title":"Acta Physiol."},{"key":"1186_CR16","doi-asserted-by":"publisher","first-page":"119","DOI":"10.1002\/nau.20841","volume":"29","author":"MJ Drake","year":"2010","unstructured":"Drake, M. J. et al. Neural control of the lower urinary and gastrointestinal tracts: supraspinal CNS mechanisms. Neurourol. Urodyn. 29, 119\u2013127 (2010).\u00a0","journal-title":"Neurourol. Urodyn."},{"key":"1186_CR17","doi-asserted-by":"publisher","first-page":"466","DOI":"10.1002\/nau.20549","volume":"27","author":"D Griffiths","year":"2008","unstructured":"Griffiths, D. & Tadic, S. D. Bladder control, urgency, and urge incontinence: evidence from functional brain imaging. Neurourol. Urodyn. 27, 466\u2013474 (2008).","journal-title":"Neurourol. Urodyn."},{"key":"1186_CR18","doi-asserted-by":"publisher","first-page":"4115","DOI":"10.1038\/s41467-025-59436-4","volume":"16","author":"Y-S Lim","year":"2025","unstructured":"Lim, Y.-S. et al. Precise control of tibial nerve stimulation for bladder regulation via evoked compound action potential feedback mechanisms. Nat. Commun. 16, 4115 (2025).","journal-title":"Nat. Commun."},{"key":"1186_CR19","doi-asserted-by":"publisher","DOI":"10.1126\/scirobotics.aaz9239","volume":"5","author":"B Shih","year":"2020","unstructured":"Shih, B. et al. Electronic skins and machine learning for intelligent soft robots. Sci. Robot. 5, eaaz9239 (2020).","journal-title":"Sci. Robot."},{"key":"1186_CR20","doi-asserted-by":"publisher","first-page":"1097","DOI":"10.1097\/JU.0000000000002235","volume":"206","author":"DA Ginsberg","year":"2021","unstructured":"Ginsberg, D. A. et al. The AUA\/SUFU Guideline on Adult Neurogenic Lower Urinary Tract Dysfunction: Diagnosis and Evaluation. J. Urol. 206, 1097\u20131105 (2021).","journal-title":"J. Urol."},{"key":"1186_CR21","doi-asserted-by":"publisher","DOI":"10.1016\/j.xcrp.2024.102281","volume":"5","author":"X Shen","year":"2024","unstructured":"Shen, X. et al. Fully implantable bladder electronic harness with soft sensing. Cell Rep. Phys. Sci. 5, 102281 (2024).","journal-title":"Cell Rep. Phys. Sci."},{"key":"1186_CR22","doi-asserted-by":"publisher","first-page":"15277","DOI":"10.1021\/acsnano.3c04089","volume":"17","author":"C Hegde","year":"2023","unstructured":"Hegde, C. et al. Sensing in soft robotics: materials, transduction and inference. ACS Nano 17, 15277\u201315307 (2023).","journal-title":"ACS Nano"},{"key":"1186_CR23","unstructured":"Cornu, J.-N. et al. EAU Guidelines on Non-Neurogenic Male Lower Urinary Tract Symptoms (LUTS). EAU Guidelines, edn presented at the EAU Annual Congress Paris, April 2024. ISBN 978-94-92671-23-3 (European Association of Urology, 2024)."},{"key":"1186_CR24","doi-asserted-by":"publisher","first-page":"205","DOI":"10.1016\/S0022-5347(17)54449-3","volume":"126","author":"EJ McGuire","year":"1981","unstructured":"McGuire, E. J., Woodside, J. R., Borden, T. A. & Weiss, R. M. Prognostic value of urodynamics in myelodysplasia. J. Urol. 126, 205\u2013209 (1981).","journal-title":"J. Urol."},{"key":"1186_CR25","doi-asserted-by":"publisher","first-page":"759","DOI":"10.1002\/nau.23017","volume":"36","author":"T Tarcan","year":"2017","unstructured":"Tarcan, T. et al. Is 40 cmH2O detrusor leak point pressure reliable? Neurourol. Urodyn. 36, 759\u2013763 (2017).","journal-title":"Neurourol. Urodyn."},{"key":"1186_CR26","doi-asserted-by":"publisher","first-page":"461","DOI":"10.4103\/0970-1591.57912","volume":"25","author":"V Kumar","year":"2009","unstructured":"Kumar, V. et al. Uroflow nomogram and volume-dependency of Qmax. Indian J. Urol. 25, 461\u2013466 (2009).","journal-title":"Indian J. Urol."},{"key":"1186_CR27","unstructured":"Yao, M., O\u2019Dell, K., Taveira-DaSilva, A. Urodynamic Testing and Interpretation (StatPearls, 2023)."},{"key":"1186_CR28","doi-asserted-by":"crossref","first-page":"434","DOI":"10.1097\/JU.0000000000003812.01","volume":"211","author":"DS Elliott","year":"2024","unstructured":"Elliott, D. S. et al. The artificial urinary sphincter clinical outcomes trial: primary results. J. Urol. 211, 434\u2013443 (2024).","journal-title":"J. Urol."},{"key":"1186_CR29","volume":"12","author":"MJ McGee","year":"2015","unstructured":"McGee, M. J., Amundsen, C. L. & Grill, W. M. Electrical stimulation for the treatment of lower urinary tract dysfunction after spinal cord injury. J. Neural Eng. 12, 021002 (2015).","journal-title":"J. Neural Eng."},{"key":"1186_CR30","doi-asserted-by":"publisher","first-page":"2801","DOI":"10.1097\/01.ju.0000140709.71932.f0","volume":"172","author":"C Tai","year":"2004","unstructured":"Tai, C. et al. Response of external urethral sphincter to high frequency biphasic electrical stimulation of pudendal nerve. J. Urol. 172, 2801\u20132805 (2004).","journal-title":"J. Urol."},{"key":"1186_CR31","doi-asserted-by":"publisher","first-page":"61","DOI":"10.1016\/B978-0-444-63247-0.00005-5","volume":"130","author":"WC de Groat","year":"2015","unstructured":"de Groat, W. C. & Yoshimura, N. Anatomy and physiology of the lower urinary tract. Handb. Clin. Neurol. 130, 61\u2013108 (2015).","journal-title":"Handb. Clin. Neurol."},{"key":"1186_CR32","volume":"2016","author":"AF Colhoun","year":"2016","unstructured":"Colhoun, A. F. et al. Dynamic elasticity of the bladder. Sci. World J. 2016, 9527360 (2016).","journal-title":"Sci. World J."},{"key":"1186_CR33","doi-asserted-by":"publisher","first-page":"361","DOI":"10.1038\/s41586-018-0823-6","volume":"565","author":"AD Mickle","year":"2019","unstructured":"Mickle, A. D. et al. A wireless closed-loop system for optogenetic peripheral neuromodulation. Nature 565, 361\u2013365 (2019).","journal-title":"Nature"},{"key":"1186_CR34","doi-asserted-by":"publisher","DOI":"10.1073\/pnas.2400868121","volume":"121","author":"J Kim","year":"2024","unstructured":"Kim, J. et al. A wireless, implantable bioelectronic system for monitoring urinary bladder function following surgical recovery. Proc. Natl Acad. Sci. USA 121, e2400868121 (2024).","journal-title":"Proc. Natl Acad. Sci. USA"},{"key":"1186_CR35","doi-asserted-by":"publisher","DOI":"10.1038\/s41467-024-50066-w","volume":"15","author":"AT Toymus","year":"2024","unstructured":"Toymus, A. T. et al. Wearable ultrasound for continuous bladder volume monitoring. Nat. Commun. 15, 5678 (2024).","journal-title":"Nat. Commun."},{"key":"1186_CR36","doi-asserted-by":"publisher","DOI":"10.1016\/j.mtbio.2024.101233","volume":"28","author":"J Li","year":"2024","unstructured":"Li, J. et al. Wireless, battery-free device for electrical neuromodulation of bladder contractions. Mater. Today Bio 28, 101233 (2024).","journal-title":"Mater. Today Bio"},{"key":"1186_CR37","doi-asserted-by":"publisher","DOI":"10.1038\/s41528-024-00329-9","volume":"8","author":"Y Deng","year":"2024","unstructured":"Deng, Y., Bu, F. & Guan, C. Stretchable liquid-metal biomedical devices. NPJ Flex. Electron. 8, 45 (2024).","journal-title":"NPJ Flex. Electron."},{"key":"1186_CR38","doi-asserted-by":"crossref","DOI":"10.3390\/s24113390","volume":"24","author":"R V\u00e1zquez","year":"2024","unstructured":"V\u00e1zquez, R. et al. Stretchable RF materials for MRI: a review. Sensors 24, 3390 (2024).","journal-title":"Sensors"},{"key":"1186_CR39","doi-asserted-by":"publisher","DOI":"10.1038\/s41598-021-95335-6","volume":"11","author":"E Motovilova","year":"2021","unstructured":"Motovilova, E. et al. Stretchable liquid-metal MRI receive coils. Sci. Rep. 11, 16228 (2021).","journal-title":"Sci. Rep."},{"key":"1186_CR40","first-page":"2619","volume":"42","author":"E Motovilova","year":"2023","unstructured":"Motovilova, E. et al. Dual-channel stretchable liquid-metal MRI coils in vivo (3 T). IEEE Trans. Med. Imaging 42, 2619\u20132629 (2023).","journal-title":"IEEE Trans. Med. Imaging"},{"key":"1186_CR41","volume":"30","author":"MKH Chowdhury","year":"2024","unstructured":"Chowdhury, M. K. H. et al. Graphene-based wearable sensors. Mater. Today Phys. 30, 100978 (2024).","journal-title":"Mater. Today Phys."},{"key":"1186_CR42","doi-asserted-by":"publisher","DOI":"10.3389\/fsens.2021.815209","volume":"2","author":"Y Fan","year":"2022","unstructured":"Fan, Y. et al. Ecoflex\/graphene high-gauge strain sensor. Front. Sens. 2, 815209 (2022).","journal-title":"Front. Sens."},{"key":"1186_CR43","volume":"12","author":"L Tang","year":"2020","unstructured":"Tang, L. et al. Conductive hydrogels for flexible strain sensors. Polymers 12, 1558 (2020).","journal-title":"Polymers"},{"key":"1186_CR44","volume":"13","author":"W Zhao","year":"2022","unstructured":"Zhao, W. et al. Water-retentive ionic-hydrogel strain sensor. Micromachines 13, 1519 (2022).","journal-title":"Micromachines"},{"key":"1186_CR45","volume":"374","author":"F Huang","year":"2025","unstructured":"Huang, F. et al. High-linearity capacitive stretch sensors. Sens. Actuators A 374, 114993 (2025).","journal-title":"Sens. Actuators A"},{"key":"1186_CR46","first-page":"789","volume":"5","author":"Y Baek","year":"2025","unstructured":"Baek, Y. et al. In\/near-sensor computing for edge intelligence. Nat. Comput. Sci. 5, 789\u2013801 (2025).","journal-title":"Nat. Comput. Sci."},{"key":"1186_CR47","volume":"6","author":"J Liu","year":"2024","unstructured":"Liu, J. et al. Near-\/in-sensor perception for wearables. Adv. Intell. Syst. 6, 2400123 (2024).","journal-title":"Adv. Intell. Syst."},{"key":"1186_CR48","doi-asserted-by":"publisher","DOI":"10.1126\/scitranslmed.aaf3925","volume":"9","author":"ET Roche","year":"2017","unstructured":"Roche, E. T. et al. A bioinspired soft robotic cardiac sleeve. Sci. Transl. Med. 9, eaaf3925 (2017).","journal-title":"Sci. Transl. Med."},{"key":"1186_CR49","volume":"25","author":"B McCormack","year":"2024","unstructured":"McCormack, B. et al. A review of ultrasound urodynamics (Laplace law insights). Curr. Urol. Rep. 25, 758 (2024).","journal-title":"Curr. Urol. Rep."},{"key":"1186_CR50","doi-asserted-by":"publisher","first-page":"259","DOI":"10.1002\/nau.22947","volume":"36","author":"T Tarcan","year":"2017","unstructured":"Tarcan, T., Demirkesen, O., Plata, M. & Castro-Diaz, D. ICS teaching module: detrusor leak point pressures in patients with relevant neurological abnormalities. Neurourol. Urodyn. 36, 259\u2013262 (2017).","journal-title":"Neurourol. Urodyn."},{"key":"1186_CR51","doi-asserted-by":"publisher","DOI":"10.3390\/act11100288","volume":"11","author":"B Kalita","year":"2022","unstructured":"Kalita, B., Thirugnanam, A. & Mahanta, C. Review on pneumatic artificial muscles. Actuators 11, 288 (2022).","journal-title":"Actuators"},{"key":"1186_CR52","doi-asserted-by":"publisher","DOI":"10.1016\/j.sna.2025.116307","volume":"386","author":"Z Awada","year":"2025","unstructured":"Awada, Z., Haddab, Y. & Gouttefarde, M. PneuNet actuator trade-offs. Sens. Actuators A 386, 116307 (2025).","journal-title":"Sens. Actuators A"},{"key":"1186_CR53","doi-asserted-by":"publisher","DOI":"10.1007\/s43939-025-00225-7","volume":"5","author":"M Ghevondyan","year":"2025","unstructured":"Ghevondyan, M., Davtyan, M. & Aghayan, M. Dielectric elastomer actuators: medical applications review. Discov. Mater. 5, 43 (2025).","journal-title":"Discov. Mater."},{"key":"1186_CR54","doi-asserted-by":"publisher","first-page":"836","DOI":"10.1126\/science.287.5454.836","volume":"287","author":"R Pelrine","year":"2000","unstructured":"Pelrine, R., Kornbluh, R., Pei, Q. & Joseph, J. High-strain electrically actuated elastomers. Science 287, 836\u2013839 (2000).","journal-title":"Science"},{"key":"1186_CR55","doi-asserted-by":"publisher","DOI":"10.3390\/app10020640","volume":"10","author":"JH Youn","year":"2020","unstructured":"Youn, J. H. et al. Dielectric elastomer actuators for soft robotics. Appl. Sci. 10, 640 (2020).","journal-title":"Appl. Sci."},{"key":"1186_CR56","doi-asserted-by":"publisher","DOI":"10.1002\/aisy.202000282","volume":"3","author":"Y Guo","year":"2021","unstructured":"Guo, Y. et al. Advances in DEA materials and actuators. Adv. Intell. Syst. 3, 2000282 (2021).","journal-title":"Adv. Intell. Syst."},{"key":"1186_CR57","doi-asserted-by":"publisher","DOI":"10.1002\/aisy.202300047","volume":"6","author":"C Tang","year":"2024","unstructured":"Tang, C. et al. High-frequency dielectric elastomer actuators. Adv. Intell. Syst. 6, 2300047 (2024).","journal-title":"Adv. Intell. Syst."},{"key":"1186_CR58","doi-asserted-by":"publisher","DOI":"10.1126\/science.abn0099","volume":"377","author":"Y Shi","year":"2022","unstructured":"Shi, Y. et al. High-performance dielectric elastomer multilayers. Science 377, eabn0099 (2022).","journal-title":"Science"},{"key":"1186_CR59","volume":"15","author":"W Feng","year":"2024","unstructured":"Feng, W. et al. Large-strain, ultrahigh-energy dielectric elastomers. Nat. Commun. 15, 48243 (2024).","journal-title":"Nat. Commun."},{"key":"1186_CR60","doi-asserted-by":"publisher","DOI":"10.1063\/5.0043959","volume":"129","author":"X Zhao","year":"2021","unstructured":"Zhao, X., Keplinger, C. & Suo, Z. Perspective on dielectric elastomer actuators. J. Appl. Phys. 129, 151102 (2021).","journal-title":"J. Appl. Phys."},{"key":"1186_CR61","doi-asserted-by":"publisher","DOI":"10.3389\/frobt.2021.672154","volume":"8","author":"X Liu","year":"2021","unstructured":"Liu, X. et al. Dynamic breakdown of VHB-4910 dielectric elastomers. Front. Robot. AI 8, 672154 (2021).","journal-title":"Front. Robot. AI"},{"key":"1186_CR62","volume":"331","author":"K Naito","year":"2021","unstructured":"Naito, K. et al. Breakdown considerations in dielectric elastomers. Sens. Actuators A 331, 112902 (2021).","journal-title":"Sens. Actuators A"},{"key":"1186_CR63","volume":"10","author":"L Tynan","year":"2025","unstructured":"Tynan, L. et al. Electrohydraulic (HASEL) actuators: a review. Actuators 10, 152 (2025).","journal-title":"Actuators"},{"key":"1186_CR64","doi-asserted-by":"publisher","DOI":"10.3390\/act13120524","volume":"13","author":"O Perera","year":"2024","unstructured":"Perera, O. et al. Soft robotic actuators and applications \u2013 the HASEL family. Actuators 13, 524 (2024).","journal-title":"Actuators"},{"key":"1186_CR65","doi-asserted-by":"publisher","DOI":"10.1038\/s44182-025-00045-0","volume":"3","author":"R Feng","year":"2025","unstructured":"Feng, R., He, Y. & Li, S. Impulsive actuation for soft robots. NPJ Robot. 3, 27 (2025).","journal-title":"NPJ Robot."},{"key":"1186_CR66","doi-asserted-by":"publisher","first-page":"5317","DOI":"10.1021\/acs.chemrev.1c00481","volume":"122","author":"Y Kim","year":"2022","unstructured":"Kim, Y. & Zhao, X. Magnetic soft materials and robots. Chem. Rev. 122, 5317\u20135364 (2022).","journal-title":"Chem. Rev."},{"key":"1186_CR67","doi-asserted-by":"publisher","DOI":"10.1097\/01.JU.0001109904.25944.a0.25","volume":"213","author":"Y Zhang","year":"2025","unstructured":"Zhang, Y. et al. Enhanced urine flow with a magnetically controlled artificial bladder and geometric sensing mechanisms. J. Urol. 213, e256 (2025).","journal-title":"J. Urol."},{"key":"1186_CR68","doi-asserted-by":"crossref","first-page":"1231","DOI":"10.1002\/nau.24864","volume":"41","author":"A Ghavidel-Sardsahra","year":"2022","unstructured":"Ghavidel-Sardsahra, A. et al. Comparison of PTNS vs TTNS for OAB: a meta-analysis. Neurourol. Urodyn. 41, 1231\u20131246 (2022).","journal-title":"Neurourol. Urodyn."},{"key":"1186_CR69","first-page":"1556","volume":"82","author":"A Mehmann","year":"2019","unstructured":"Mehmann, A. et al. Performance of liquid-metal MRI coils. Magn. Reson. Med. 82, 1556\u20131569 (2019).","journal-title":"Magn. Reson. Med."},{"key":"1186_CR70","unstructured":"International Organization for Standardization. ISO\/TS 10974:2018. Assessment of the safety of magnetic resonance imaging for patients with an active implantable medical device. 2nd edn (ISO, 2018)."},{"key":"1186_CR71","unstructured":"ASTM International. ASTM F2182-19e2. Standard test method for measurement of radio frequency induced heating on or near passive implants during magnetic resonance imaging (ASTM International, 2019)."},{"key":"1186_CR72","unstructured":"ASTM International. ASTM F2052-21. Standard test method for measurement of magnetically induced displacement force on medical devices in the magnetic resonance environment (ASTM International, 2021)."},{"key":"1186_CR73","unstructured":"ASTM International. ASTM F2213-17. Standard test method for measurement of magnetically induced torque on medical devices in the magnetic resonance environment (ASTM International, 2017)."},{"key":"1186_CR74","unstructured":"International Electrotechnical Commission. IEC 60601-1-2:2014+AMD1:2020. Medical electrical equipment \u2014 Part 1-2: General requirements for basic safety and essential performance \u2014 Collateral Standard: Electromagnetic disturbances \u2014 Requirements and tests (IEC, 2020)."},{"key":"1186_CR75","unstructured":"U.S. Food and Drug Administration. Testing and labeling medical devices for safety in the magnetic resonance (MR) environment: guidance for industry and Food and Drug Administration staff. Final guidance (October, 2023)."},{"key":"1186_CR76","first-page":"77186","volume":"13","author":"S Heydari","year":"2025","unstructured":"Heydari, S. et al. Tiny machine learning: a survey. IEEE Access. 13, 77186\u201377223 (2025).","journal-title":"IEEE Access."},{"key":"1186_CR77","unstructured":"MLCommons. MLCommons New MLPerf Tiny 1.3 Benchmark results released (17 September 2025)."},{"key":"1186_CR78","unstructured":"MLCommons. MLPerf Inference: Tiny. Benchmark suite results (accessed 2025)."},{"key":"1186_CR79","doi-asserted-by":"publisher","DOI":"10.3390\/batteries9030186","volume":"9","author":"B Wu","year":"2023","unstructured":"Wu, B., Chen, C., Danilov, D. L., Eichel, R.-A. & Notten, P. H. L. All-solid-state thin-film Li-ion batteries. Batteries 9, 186 (2023).","journal-title":"Batteries"},{"key":"1186_CR80","doi-asserted-by":"publisher","DOI":"10.1016\/j.jallcom.2024.173551","volume":"979","author":"L Zhai","year":"2024","unstructured":"Zhai, L., Duan, J., Lin, T. & Shao, H. Recent advances in implantable batteries. J. Alloy. Compd. 979, 173551 (2024).","journal-title":"J. Alloy. Compd."},{"key":"1186_CR81","unstructured":"Cymbet Corporation. EnerChip CBC050 Solid State Battery. Data Sheet DS-72-01 Rev. E (Cymbet Corporation, 2014)."},{"key":"1186_CR82","doi-asserted-by":"publisher","DOI":"10.3389\/frcdi.2024.1401391","volume":"2","author":"M Curcio","year":"2024","unstructured":"Curcio, M., Teghil, R. & De Bonis, A. Thin-film microbattery fabrication by PLD. Front. Coat. Dye. Interface Eng. 2, 1401391 (2024).","journal-title":"Front. Coat. Dye. Interface Eng."},{"key":"1186_CR83","unstructured":"Ensurge Micropower. A new generation of solid-state microbattery. Ensurge Micropower technology webpage (accessed 2025)."},{"key":"1186_CR84","doi-asserted-by":"publisher","DOI":"10.1093\/nsr\/nwae062","volume":"11","author":"Y Li","year":"2024","unstructured":"Li, Y. et al. Ultra-low-frequency magnetic energy focusing for wireless power. Natl Sci. Rev. 11, nwae062 (2024).","journal-title":"Natl Sci. Rev."},{"key":"1186_CR85","volume":"18","author":"JS Neimat","year":"2025","unstructured":"Neimat, J. S. et al. Wireless low-energy ultrasound power & communication for neurostimulator. Brain Stimul. 18, 100123 (2025).","journal-title":"Brain Stimul."},{"key":"1186_CR86","doi-asserted-by":"publisher","DOI":"10.1093\/nsr\/nwae140","volume":"11","author":"H Wang","year":"2024","unstructured":"Wang, H. & Yu, X. Wireless powering solution for implantable electronics based on ultra-low frequency magnetic energy focusing. Natl Sci. Rev. 11, nwae140 (2024).","journal-title":"Natl Sci. Rev."},{"key":"1186_CR87","doi-asserted-by":"publisher","first-page":"706","DOI":"10.1038\/s41551-022-00873-7","volume":"6","author":"JC Chen","year":"2022","unstructured":"Chen, J. C. et al. A wireless millimetric magnetoelectric implant for endovascular nerve stimulation. Nat. Biomed. Eng. 6, 706\u2013716 (2022).","journal-title":"Nat. Biomed. Eng."},{"key":"1186_CR88","volume":"29","author":"P Li","year":"2025","unstructured":"Li, P. et al. Implantable magnetoelectric bioelectronics for wireless power and communication. Mater. Today Bio 29, 101501 (2025).","journal-title":"Mater. Today Bio"},{"key":"1186_CR89","doi-asserted-by":"crossref","first-page":"14436","DOI":"10.1021\/acsami.2c22513","volume":"15","author":"U Passlack","year":"2023","unstructured":"Passlack, U. et al. Ultrathin chip-film patch with ALD nanolaminates. ACS Appl. Mater. Interfaces 15, 14436\u201314448 (2023).","journal-title":"ACS Appl. Mater. Interfaces"},{"key":"1186_CR90","doi-asserted-by":"publisher","DOI":"10.1088\/0960-1317\/24\/12\/125014","volume":"24","author":"X Xie","year":"2014","unstructured":"Xie, X. et al. Long-term reliability of ALD Al2O3 + parylene-C encapsulation. J. Micromech. Microeng. 24, 125014 (2014).","journal-title":"J. Micromech. Microeng."},{"key":"1186_CR91","doi-asserted-by":"publisher","DOI":"10.3390\/mi15040478","volume":"15","author":"B Zhang","year":"2024","unstructured":"Zhang, B. et al. Flexible encapsulation films with ultrahigh barrier performance. Micromachines 15, 478 (2024).","journal-title":"Micromachines"},{"key":"1186_CR92","volume":"13","author":"A Pak","year":"2022","unstructured":"Pak, A. et al. Thin-film encapsulation for LCP-based flexible implants. Micromachines 13, 583 (2022).","journal-title":"Micromachines"},{"key":"1186_CR93","unstructured":"U.S. Food and Drug Administration. Use of International Standard ISO 10993-1, \u201cBiological evaluation of medical devices \u2014 Part 1: Evaluation and testing within a risk management process\u201d: guidance for industry and Food and Drug Administration staff. Final guidance (September 2023)."},{"key":"1186_CR94","unstructured":"International Organization for Standardization. ISO 11135:2014. Sterilization of health-care products \u2014 Ethylene oxide \u2014 Requirements for the development, validation and routine control of a sterilization process for medical devices. 2nd edn (ISO, 2014)."},{"key":"1186_CR95","unstructured":"International Organization for Standardization. ISO 10993-7:2026. Biological evaluation of medical devices \u2014 Part 7: Ethylene oxide sterilization residuals. 3rd edn (ISO, 2026)."},{"key":"1186_CR96","unstructured":"International Organization for Standardization. ISO 11137-1:2025. Sterilization of health care products \u2014 Radiation \u2014 Part 1: Requirements for the development, validation and routine control of a sterilization process for medical devices. 2nd edn (ISO, 2025)."},{"key":"1186_CR97","unstructured":"International Organization for Standardization. ISO 22441:2022. Sterilization of health care products \u2014 Low temperature vaporized hydrogen peroxide \u2014 Requirements for the development, validation and routine control of a sterilization process for medical devices. 1st edn (ISO, 2022)."},{"key":"1186_CR98","unstructured":"Federal Communications Commission. 47 CFR Part 95, Subpart I \u2014 Medical Device Radio Communications Service (MedRadio) (accessed 2025)."},{"key":"1186_CR99","unstructured":"European Telecommunications Standards Institute. ETSI EN 301 839 V2.1.1 (2016-04). Ultra Low Power Active Medical Implants (ULP-AMI) and associated Peripherals (ULP-AMI-P) operating in the frequency range 402 MHz to 405 MHz; Harmonised Standard covering the essential requirements of Article 3.2 of Directive 2014\/53\/EU (ETSI, 2016)."},{"key":"1186_CR100","unstructured":"European Telecommunications Standards Institute. ETSI EN 301 839-1 V1.1.1 (2002-06). Electromagnetic compatibility and radio spectrum matters (ERM); radio equipment in the frequency range 402 MHz to 405 MHz for ultra low power active medical implants and accessories; Part 1: Technical characteristics, including electromagnetic compatibility requirements, and test methods (ETSI, 2002)."},{"key":"1186_CR101","unstructured":"U.S. Food and Drug Administration. Marketing submission recommendations for a predetermined change control plan for artificial intelligence-enabled device software functions: guidance for industry and Food and Drug Administration staff. Final guidance (August 2025)."},{"key":"1186_CR102","unstructured":"U.S. Food and Drug Administration. Cybersecurity in medical devices: quality management system considerations and content of premarket submissions: guidance for industry and Food and Drug Administration staff. Final guidance (February, 2026)."},{"key":"1186_CR103","first-page":"793","volume":"6","author":"R Shapiro","year":"2021","unstructured":"Shapiro, R. et al. A comparative study of braided versus barbed suture for cystotomy repair. Res. Rep. Urol. 13, 793\u2013798 (2021).","journal-title":"Res. Rep. Urol."},{"key":"1186_CR104","doi-asserted-by":"publisher","first-page":"100062","DOI":"10.1016\/j.xagr.2022.100062","volume":"2","author":"AS Zelivianskaia","year":"2022","unstructured":"Zelivianskaia, A. S., Bradley, S. E. & Morozov, V. V. Best practices for repair of iatrogenic bladder injury. AJOG Glob. Rep. 2, 100062 (2022).","journal-title":"AJOG Glob. Rep."},{"key":"1186_CR105","doi-asserted-by":"publisher","first-page":"126","DOI":"10.4274\/tjod.galenos.2023.21208","volume":"20","author":"S Ate\u015f Tatar","year":"2023","unstructured":"Ate\u015f Tatar, S. et al. Barbed versus conventional suture in laparoscopic myomectomy: a randomized controlled study. Turk. J. Obstet. Gynecol. 20, 126\u2013130 (2023).","journal-title":"Turk. J. Obstet. Gynecol."},{"key":"1186_CR106","doi-asserted-by":"publisher","first-page":"1749","DOI":"10.3390\/polym17131749","volume":"17","author":"M Boursier","year":"2025","unstructured":"Boursier, M., Bayon, Y., Negrell, C., Pinaud, J. & Caillol, S. Biocompatible glues: recent progress and emerging frontiers in surgical adhesion. Polymers 17, 1749 (2025).","journal-title":"Polymers"},{"key":"1186_CR107","doi-asserted-by":"publisher","first-page":"92","DOI":"10.1109\/TNSRE.2025.3637066","volume":"34","author":"X Cai","year":"2026","unstructured":"Cai, X. et al. A novel brain\u2013computer interface application: precise decoding of urination and defecation motor attempts in spinal cord injury patients. IEEE Trans. Neural Syst. Rehabil. Eng. 34, 92\u2013102 (2026).","journal-title":"IEEE Trans. Neural Syst. Rehabil. Eng."}],"container-title":["Nature Reviews Urology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.nature.com\/articles\/s41585-026-01186-z.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.nature.com\/articles\/s41585-026-01186-z","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.nature.com\/articles\/s41585-026-01186-z.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,9,23]],"date-time":"2026-09-23T23:02:50Z","timestamp":1790204570000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.nature.com\/articles\/s41585-026-01186-z"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,9,23]]},"references-count":107,"alternative-id":["1186"],"URL":"https:\/\/doi.org\/10.1038\/s41585-026-01186-z","relation":{},"ISSN":["1759-4812","1759-4820"],"issn-type":[{"value":"1759-4812","type":"print"},{"value":"1759-4820","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,9,23]]},"assertion":[{"value":"21 August 2026","order":1,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"23 September 2026","order":2,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"The authors declare no competing interests.","order":1,"name":"Ethics","label":"Competing interests","group":{"name":"EthicsHeading","label":"Ethics"}}]}}