{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,11,2]],"date-time":"2026-11-02T22:42:46Z","timestamp":1793659366170,"version":"4.5.1"},"reference-count":22,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2025,4,3]],"date-time":"2025-04-03T00:00:00Z","timestamp":1743638400000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2025,4,3]],"date-time":"2025-04-03T00:00:00Z","timestamp":1743638400000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Sci Data"],"abstract":"<jats:title>Abstract<\/jats:title>\n          <jats:p>The OpenOximetry Dataset stores clinical and lab pulse oximetry data. It supports measurements of arterial oxygen saturation (SaO2) by arterial blood gas co-oximetry and pulse oximetry (SpO2), alongside processed and unprocessed photoplethysmography (PPG) data and other metadata. This includes skin color measurements, finger diameter, vital signs (e.g., arterial blood pressure, end-tidal carbon dioxide), and arterial blood gas parameters (e.g., acid-base balance, hemoglobin concentration). All data, from desaturation studies to clinical trials, are collected prospectively to ensure accuracy. A common data model and standardized protocols for consistent archival and interpretation ensure consistent data archival and interpretation. The dataset aims to facilitate research on pulse oximeter performance across diverse human characteristics, addressing performance issues and promoting accurate pulse oximeters. The initial release includes controlled lab desaturation studies (CLDS), with ongoing updates planned as further data from clinical trials and CLDS become available.<\/jats:p>","DOI":"10.1038\/s41597-025-04870-8","type":"journal-article","created":{"date-parts":[[2025,4,4]],"date-time":"2025-04-04T22:46:49Z","timestamp":1743806809000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":6,"title":["Open Access Dataset and Common Data Model for Pulse Oximeter Performance Data"],"prefix":"10.1038","volume":"12","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-3412-0735","authenticated-orcid":false,"given":"Nicholas","family":"Fong","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Michael S.","family":"Lipnick","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ella","family":"Behnke","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yu","family":"Chou","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Seif","family":"Elmankabadi","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Lily","family":"Ortiz","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Christopher S.","family":"Almond","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Isabella","family":"Auchus","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Garrett W.","family":"Burnett","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ronald","family":"Bisegerwa","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Desire\u00e9 R.","family":"Conrad","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Carolyn M.","family":"Hendrickson","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Shubhada","family":"Hooli","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Robert","family":"Kopotic","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Gregory","family":"Leeb","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Daniel","family":"Martin","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Eric D.","family":"McCollum","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ellis P.","family":"Monk","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"suffix":"Jr.","given":"Kelvin L.","family":"Moore","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-9210-7873","authenticated-orcid":false,"given":"Leonid","family":"Shmuylovich","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"J. Brady","family":"Scott","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-5668-4251","authenticated-orcid":false,"given":"An-Kwok Ian","family":"Wong","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Tianyue","family":"Zhou","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-7007-4908","authenticated-orcid":false,"given":"Romain","family":"Pirracchio","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Philip E.","family":"Bickler","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"John","family":"Feiner","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Tyler J.","family":"Law","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2025,4,3]]},"reference":[{"key":"4870_CR1","doi-asserted-by":"crossref","first-page":"S18","DOI":"10.1213\/01.ane.0000285988.35174.d9","volume":"105","author":"JR Feiner","year":"2007","unstructured":"Feiner, J. R., Severinghaus, J. W. & Bickler, P. E. Dark skin decreases the accuracy of pulse oximeters at low oxygen saturation: the effects of oximeter probe type and gender. Anesth. Analg. 105, S18\u2013S23 (2007).","journal-title":"Anesth. Analg."},{"key":"4870_CR2","doi-asserted-by":"crossref","first-page":"715","DOI":"10.1097\/00000542-200504000-00004","volume":"102","author":"PE Bickler","year":"2005","unstructured":"Bickler, P. E., Feiner, J. R. & Severinghaus, J. W. Effects of skin pigmentation on pulse oximeter accuracy at low saturation. Anesthesiology 102, 715\u2013719 (2005).","journal-title":"Anesthesiology"},{"key":"4870_CR3","volume":"20","author":"C Shi","year":"2022","unstructured":"Shi, C. et al. The accuracy of pulse oximetry in measuring oxygen saturation by levels of skin pigmentation: a systematic review and meta-analysis. BMC Med. 20, 267 (2022).","journal-title":"BMC Med."},{"key":"4870_CR4","doi-asserted-by":"crossref","first-page":"2477","DOI":"10.1056\/NEJMc2029240","volume":"383","author":"MW Sjoding","year":"2020","unstructured":"Sjoding, M. W., Dickson, R. P., Iwashyna, T. J., Gay, S. E. & Valley, T. S. Racial Bias in Pulse Oximetry Measurement. N. Engl. J. Med. 383, 2477\u20132478 (2020).","journal-title":"N. Engl. J. Med."},{"key":"4870_CR5","first-page":"329","volume":"7","author":"JR Emery","year":"1987","unstructured":"Emery, J. R. Skin pigmentation as an influence on the accuracy of pulse oximetry. J. Perinatol. Off. J. Calif. Perinat. Assoc. 7, 329\u2013330 (1987).","journal-title":"J. Perinatol. Off. J. Calif. Perinat. Assoc."},{"key":"4870_CR6","doi-asserted-by":"crossref","first-page":"1240","DOI":"10.1164\/ajrccm\/144.6.1240","volume":"144","author":"RJ Zeballos","year":"1991","unstructured":"Zeballos, R. J. & Weisman, I. M. Reliability of noninvasive oximetry in black subjects during exercise and hypoxia. Am. Rev. Respir. Dis. 144, 1240\u20131244 (1991).","journal-title":"Am. Rev. Respir. Dis."},{"key":"4870_CR7","first-page":"594","volume":"86","author":"PA Bothma","year":"1996","unstructured":"Bothma, P. A. et al. Accuracy of pulse oximetry in pigmented patients. South Afr. Med. J. Suid-Afr. Tydskr. Vir Geneeskd. 86, 594\u2013596 (1996).","journal-title":"South Afr. Med. J. Suid-Afr. Tydskr. Vir Geneeskd."},{"key":"4870_CR8","doi-asserted-by":"crossref","first-page":"965","DOI":"10.1111\/j.1553-2712.1998.tb02772.x","volume":"5","author":"JN Adler","year":"1998","unstructured":"Adler, J. N., Hughes, L. A., Vivilecchia, R. & Camargo, C. A. Effect of skin pigmentation on pulse oximetry accuracy in the emergency department. Acad. Emerg. Med. Off. J. Soc. Acad. Emerg. Med. 5, 965\u2013970 (1998).","journal-title":"Acad. Emerg. Med. Off. J. Soc. Acad. Emerg. Med."},{"key":"4870_CR9","doi-asserted-by":"crossref","first-page":"730","DOI":"10.1001\/jamainternmed.2022.1906","volume":"182","author":"A Fawzy","year":"2022","unstructured":"Fawzy, A. et al. Racial and Ethnic Discrepancy in Pulse Oximetry and Delayed Identification of Treatment Eligibility Among Patients With COVID-19. JAMA Intern. Med. 182, 730\u2013738 (2022).","journal-title":"JAMA Intern. Med."},{"key":"4870_CR10","doi-asserted-by":"crossref","first-page":"703","DOI":"10.1093\/aje\/kwac164","volume":"192","author":"SEK Sudat","year":"2023","unstructured":"Sudat, S. E. K. et al. Racial Disparities in Pulse Oximeter Device Inaccuracy and Estimated Clinical Impact on COVID-19 Treatment Course. Am. J. Epidemiol. 192, 703\u2013713 (2023).","journal-title":"Am. J. Epidemiol."},{"key":"4870_CR11","doi-asserted-by":"crossref","first-page":"252","DOI":"10.4187\/respcare.09795","volume":"67","author":"OE Okunlola","year":"2022","unstructured":"Okunlola, O. E. et al. Pulse Oximeter Performance, Racial Inequity, and the Work Ahead. Respir. Care 67, 252\u2013257 (2022).","journal-title":"Respir. Care"},{"key":"4870_CR12","unstructured":"Hypoxia lab study protocol basic pulse ox hypoxemia performance study. WHO Protocol ID: ERC.0004026 https:\/\/docs.google.com\/document\/d\/1bpVzZg9M0StLoyB_iF07V8at0h8lQhDyYnNCoSMVZQ (2024)."},{"key":"4870_CR13","doi-asserted-by":"crossref","first-page":"688","DOI":"10.1097\/ALN.0000000000004153","volume":"136","author":"GW Burnett","year":"2022","unstructured":"Burnett, G. W. et al. Self-reported Race\/Ethnicity and Intraoperative Occult Hypoxemia: A Retrospective Cohort Study. Anesthesiology 136, 688\u2013696 (2022).","journal-title":"Anesthesiology"},{"key":"4870_CR14","unstructured":"openoximetry.org. Study Protocols. OpenOximetry https:\/\/openoximetry.org\/study-protocols\/."},{"key":"4870_CR15","unstructured":"ClinicalTrials.gov: Pulse Oximetry Errors in Hospitalized Patients Across Varying Skin Pigmentation. https:\/\/clinicaltrials.gov\/study\/NCT05554510."},{"key":"4870_CR16","doi-asserted-by":"publisher","DOI":"10.1164\/rccm.202401-0036LE","author":"A Fawzy","year":"2024","unstructured":"Fawzy, A. et al. Skin Pigmentation and Pulse Oximeter Accuracy in the Intensive Care Unit: A Pilot Prospective Study. Am. J. Respir. Crit. Care Med. https:\/\/doi.org\/10.1164\/rccm.202401-0036LE (2024)."},{"key":"4870_CR17","doi-asserted-by":"crossref","first-page":"375","DOI":"10.1016\/j.jpeds.2016.11.043","volume":"182","author":"EE Foglia","year":"2017","unstructured":"Foglia, E. E. et al. The Effect of Skin Pigmentation on the Accuracy of Pulse Oximetry in Infants with Hypoxemia. J. Pediatr. 182, 375\u2013377.e2 (2017).","journal-title":"J. Pediatr."},{"key":"4870_CR18","unstructured":"openoximetry.org. Collaborative Community. OpenOximetry https:\/\/openoximetry.org\/community\/."},{"key":"4870_CR19","unstructured":"HypoxiaLab. Hypoxia Lab https:\/\/hypoxialab.com\/ (2024)."},{"key":"4870_CR20","doi-asserted-by":"crossref","first-page":"599","DOI":"10.1152\/jappl.1979.46.3.599","volume":"46","author":"JW Severinghaus","year":"1979","unstructured":"Severinghaus, J. W. Simple, accurate equations for human blood O2 dissociation computations. J. Appl. Physiol. 46, 599\u2013602 (1979).","journal-title":"J. Appl. Physiol."},{"key":"4870_CR21","doi-asserted-by":"publisher","DOI":"10.13026\/CC78-AD74","author":"N Fong","year":"2024","unstructured":"Fong, N., Lipnick, M., Bickler, P., Feiner, J. & Law, T. OpenOximetry Repository. https:\/\/doi.org\/10.13026\/CC78-AD74 (2024)."},{"key":"4870_CR22","unstructured":"Hypoxia Lab Skin Color Assessment Protocol. UCSF IRB: 21-35637 https:\/\/docs.google.com\/document\/d\/17SGVjf1phxyhBB3TvetyuOFN_UC5z2humiEHI4dcEro (2024)."}],"container-title":["Scientific Data"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.nature.com\/articles\/s41597-025-04870-8.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.nature.com\/articles\/s41597-025-04870-8","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.nature.com\/articles\/s41597-025-04870-8.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,4,4]],"date-time":"2025-04-04T22:47:20Z","timestamp":1743806840000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.nature.com\/articles\/s41597-025-04870-8"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,4,3]]},"references-count":22,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2025,12]]}},"alternative-id":["4870"],"URL":"https:\/\/doi.org\/10.1038\/s41597-025-04870-8","relation":{"references":[{"id-type":"doi","id":"10.1164\/rccm.202401-0036LE","asserted-by":"subject"},{"id-type":"doi","id":"10.13026\/CC78-AD74","asserted-by":"subject"}]},"ISSN":["2052-4463"],"issn-type":[{"value":"2052-4463","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,4,3]]},"assertion":[{"value":"27 November 2024","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"20 March 2025","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"3 April 2025","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"The UCSF Hypoxia Research Laboratory receives funding from pulse oximeter manufacturers\/sponsors to test the sponsors\u2019 devices for the purposes of product development and regulatory performance testing. Data submitted by the UCSF Hypoxia Lab for this dataset do not include Hypoxia Lab sponsors\u2019 study devices unless the sponsor provides consent to include these data. Otherwise, all UCSF Hypoxia Lab data are collected from devices procured by the Hypoxia Lab for the purposes of independent research. At the time of this publication, no pulse oximeter company provides direct funding for the Open Oximetry Project, participates in study design or analysis, or is involved in the creation of this data dataset. None of the investigators who maintain this database own stock or equity interests in any pulse oximeter device companies. AIW holds equity and management roles in Ataia Medical. Atia Medical was not involved in study design, funding, or any portion of the study. There are no other conflicts of interest to declare.","order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"570"}}