{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,11,6]],"date-time":"2026-11-06T17:38:51Z","timestamp":1793986731600,"version":"4.8.0"},"reference-count":24,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2017,3,22]],"date-time":"2017-03-22T00:00:00Z","timestamp":1490140800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2017,3,22]],"date-time":"2017-03-22T00:00:00Z","timestamp":1490140800000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Sci Rep"],"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:p>Thoracic fluid accumulation is one of the significant and early-stage manifestations of fatal diseases, such as lung-cancer, liver-failure and congestive heart-failure. Currently, computational-tomography (CT)-Scan is the most widely used tool for the detection of thoracic fluid. Yet, it is unable to detect small amounts of fluid, has ionizing radiation and lacks mobility. On the other hand, microwave imaging systems have emerged as an accurate and portable complementary diagnostic tool. However, there is a lack of a complete clinical platform that can fulfill the requirements of accurate and reliable imaging. Therefore, a microwave torso scanner that is designed to meet those requirements is presented. In this system, two elliptical-arrays of microwave antennas (sensors) transmit signals towards the torso and collect the back-scattered signals. The captured signals are then processed by a frequency-based imaging algorithm to form microwave images that display a possible accumulated fluid. The system successfully detects and localized small volumes (3\u2009mL) of fluid injected at different places inside a torso-phantom. As preparations for future clinical trials, the system is tested on healthy subjects to define the threshold range of healthy scenario images.<\/jats:p>","DOI":"10.1038\/s41598-017-00436-w","type":"journal-article","created":{"date-parts":[[2017,3,16]],"date-time":"2017-03-16T05:52:32Z","timestamp":1489643552000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":35,"title":["Novel Microwave Torso Scanner for Thoracic Fluid Accumulation Diagnosis and Monitoring"],"prefix":"10.1038","volume":"7","author":[{"given":"S.","family":"Ahdi Rezaeieh","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"A.","family":"Zamani","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"K. S.","family":"Bialkowski","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-8015-5883","authenticated-orcid":false,"given":"A. M.","family":"Abbosh","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2017,3,22]]},"reference":[{"key":"436_CR1","unstructured":"World Health Care Fact Sheet on Cardiovascular diseases (CVDs). Available at: http:\/\/www.who.int\/mediacentre\/factsheets\/fs317\/en\/. (Accessed: 15th June 2016) (2015)."},{"key":"436_CR2","doi-asserted-by":"publisher","first-page":"10646","DOI":"10.1038\/ncomms10501","volume":"7","author":"S Koyama","year":"2016","unstructured":"Koyama, S. et al. Adaptive resistance to therapeutic PD-1 blockade is associated with upregulation of alternative immune checkpoints. Nat. Commun \n                           7, 10646 (2016).","journal-title":"Nat. Commun"},{"key":"436_CR3","doi-asserted-by":"publisher","first-page":"1759","DOI":"10.1038\/ncomms2774","volume":"4","author":"A Mammoto","year":"2013","unstructured":"Mammoto, A. et al. Control of lung vascular permeability and endotoxin-induced pulmonary oedema by changes in extracellular matrix mechanics. Nat. Commun \n                           4, 1759 (2013).","journal-title":"Nat. Commun"},{"key":"436_CR4","doi-asserted-by":"publisher","first-page":"673","DOI":"10.1109\/PROC.1973.9132","volume":"61","author":"C Susskind","year":"1973","unstructured":"Susskind, C. Possible use of microwaves in the management of lung disease. IEEE Proc. \n                           61, 673\u2013674 (1973).","journal-title":"IEEE Proc."},{"key":"436_CR5","doi-asserted-by":"publisher","first-page":"40","DOI":"10.1109\/TBME.1978.326376","volume":"25","author":"PC Pedersen","year":"1978","unstructured":"Pedersen, P. C., Johnson, C. C., Durney, C. H. & Bragg, D. G. Microwave reflection and transmission measurements for pulmonary diagnosis and monitoring. IEEE Trans. Biomed. Eng. \n                           25, 40\u201348 (1978).","journal-title":"IEEE Trans. Biomed. Eng."},{"key":"436_CR6","doi-asserted-by":"publisher","first-page":"265","DOI":"10.1029\/RS014i06Sp00265","volume":"14","author":"M Iskander","year":"1979","unstructured":"Iskander, M., Durney, C., Shoff, D. & Bragg, D. Diagnosis of pulmonary edema by a surgically noninvasive microwave technique. Radio Sci. \n                           14, 265\u2013269 (1979).","journal-title":"Radio Sci."},{"key":"436_CR7","doi-asserted-by":"publisher","first-page":"2341","DOI":"10.1109\/TBME.2013.2241763","volume":"61","author":"N Celik","year":"2014","unstructured":"Celik, N., Gagarin, R., Huang, G. C., Iskander, M. F. & Berg, B. W. Microwave stethoscope: development and benchmarking of a vital signs sensor using computer-controlled phantoms and human studies. IEEE Trans. Biomed. Eng. \n                           61, 2341\u20132349 (2014).","journal-title":"IEEE Trans. Biomed. Eng."},{"key":"436_CR8","doi-asserted-by":"publisher","first-page":"2787","DOI":"10.1109\/TAP.2014.2309132","volume":"62","author":"S Salman","year":"2014","unstructured":"Salman, S. et al. Pulmonary edema monitoring sensor with integrated body-area network for remote medical sensing. IEEE Trans. Antennas Propag. \n                           62, 2787\u20132794 (2014).","journal-title":"IEEE Trans. Antennas Propag."},{"key":"436_CR9","doi-asserted-by":"publisher","first-page":"921","DOI":"10.1109\/ACCESS.2014.2352614","volume":"2","author":"SA Rezaeieh","year":"2014","unstructured":"Rezaeieh, S. A., Bialkowski, K. S. & Abbosh, A. M. Microwave system for the early stage detection of congestive heart failure. IEEE Access \n                           2, 921\u2013929 (2014).","journal-title":"IEEE Access"},{"key":"436_CR10","doi-asserted-by":"publisher","first-page":"410","DOI":"10.1109\/TBME.1976.324653","volume":"23","author":"PC Pedersen","year":"1976","unstructured":"Pedersen, P. C., Johnson, C. C., Durney, C. H. & Bragg, D. G. An investigation of the use of microwave radiation for pulmonary diagnostics. IEEE Trans. Biomed. Eng. \n                           23, 410\u2013412 (1976).","journal-title":"IEEE Trans. Biomed. Eng."},{"key":"436_CR11","first-page":"5697","volume":"31","author":"K Mulligan","year":"2009","unstructured":"Mulligan, K., Adler, A. & Goubran, R. Detecting regional lung properties using audio transfer functions of the respiratory system. IEEE Intl. Conf. Eng. Medicine and Biology Soc. \n                           31, 5697\u20135700 (2009).","journal-title":"IEEE Intl. Conf. Eng. Medicine and Biology Soc."},{"key":"436_CR12","first-page":"685","volume":"29","author":"L Beckmann","year":"2007","unstructured":"Beckmann, L., Riesen, Dv & Leonhardt, S. Optimal electrode placement and frequency range selection for the detection of lung water using bioimpedance spectroscopy. IEEE Intl. Conf. Eng. Medicine and Biology Soc. \n                           29, 685\u20132688 (2007).","journal-title":"IEEE Intl. Conf. Eng. Medicine and Biology Soc."},{"key":"436_CR13","doi-asserted-by":"publisher","first-page":"554","DOI":"10.1109\/TMTT.1984.1132726","volume":"32","author":"MF Iskander","year":"1984","unstructured":"Iskander, M. F., Durney, C. H., Grange, T. & Smith, C. S. Radiometric technique for measuring changes in lung water. IEEE Trans. Microw. Theory Tech. \n                           32, 554\u2013556 (1984).","journal-title":"IEEE Trans. Microw. Theory Tech."},{"key":"436_CR14","doi-asserted-by":"publisher","first-page":"651","DOI":"10.1109\/TMAG.2011.2174779","volume":"48","author":"S Zhang","year":"2012","unstructured":"Zhang, S. et al. Computation of a 3-D model for lung imaging with electrical impedance tomography. IEEE Trans. Magn. \n                           48, 651\u2013654 (2012).","journal-title":"IEEE Trans. Magn."},{"key":"436_CR15","doi-asserted-by":"publisher","first-page":"14047","DOI":"10.1038\/srep14047","volume":"5","author":"SA Rezaeieh","year":"2015","unstructured":"Rezaeieh, S. A., Zamani, A., Biaklowski, K. S., Mahmood, A. & Abbosh, A. M. Feasibility of using wideband microwave system for non-invasive detection and monitoring of pulmonary oedema. Sci. Rep. \n                           5, 14047 (2015).","journal-title":"Sci. Rep."},{"key":"436_CR16","unstructured":"Keysight L4490A\/91A RF Switch Platform Catalogue. Available at: http:\/\/literature.cdn.keysight.com\/litweb\/pdf\/5989-7857EN.pdf?id=1365742 (Accessed: 15th June 2016) (2014)."},{"key":"436_CR17","unstructured":"N9923A FieldFox Handheld RF Vector Network Analyzer Datasheet. Available at: http:\/\/literature.cdn.keysight.com\/litweb\/pdf\/5990-5363EN.pdf?id=1856098 (Accessed: 15th June 2016) (2014)."},{"key":"436_CR18","unstructured":"Federal Communications Commission Office of Engineering & Technology. Guidelines. Available at: http:\/\/transition.fcc.gov\/Bureaus\/Engineering_Technology\/Documents\/bulletins\/oet65\/oet65c.pdf. Accessed: 15th June 2016) (2001)."},{"key":"436_CR19","doi-asserted-by":"publisher","first-page":"2806","DOI":"10.1109\/TBME.2014.2330554","volume":"61","author":"M Persson","year":"2014","unstructured":"Persson, M. et al. Microwave-based stroke diagnosis making global prehospital thrombolytic treatment possible. IEEE Trans. Biomed. Eng. \n                           61, 2806\u20132817 (2014).","journal-title":"IEEE Trans. Biomed. Eng."},{"key":"436_CR20","doi-asserted-by":"publisher","first-page":"75","DOI":"10.1055\/s-0031-1273942","volume":"28","author":"H Yu","year":"2011","unstructured":"Yu, H. Management of pleural effusion, empyema, and lung abscess. Seminars Interventional Radiol. \n                           28, 75\u201386 (2011).","journal-title":"Seminars Interventional Radiol."},{"key":"436_CR21","doi-asserted-by":"publisher","first-page":"72","DOI":"10.4236\/abcr.2013.23013","volume":"2","author":"M Al-Bayati","year":"2013","unstructured":"Al-Bayati, M. & El-Zaart, A. Mammogram images thresholding for breast cancer detection using different thresholding methods. Advances in Breast Cancer Research \n                           2, 72\u201377 (2013).","journal-title":"Advances in Breast Cancer Research"},{"key":"436_CR22","doi-asserted-by":"publisher","first-page":"1064","DOI":"10.1016\/j.acra.2009.03.018","volume":"16","author":"JE Levman","year":"2009","unstructured":"Levman, J. E., Causer, P., Warner, E. & Martel, A. L. Effect of the enhancement threshold on the computer-aided detection of breast cancer using MRI. Academic radiology \n                           16, 1064\u20131069 (2009).","journal-title":"Academic radiology"},{"key":"436_CR23","first-page":"653","volume":"64","author":"A Zamani","year":"2016","unstructured":"Zamani, A., Abbosh, A. M. & Mobashsher, A. T. Fast frequency-based multistatic microwave imaging algorithm with application to brain injury detection. IEEE Trans. Microwave Theory Tech. \n                           64, 653\u2013662 (2016).","journal-title":"Microwave Theory Tech."},{"key":"436_CR24","doi-asserted-by":"publisher","first-page":"740","DOI":"10.1049\/el.2015.0230","volume":"51","author":"A Zamani","year":"2015","unstructured":"Zamani, A., Rezaeieh, S. A. & Abbosh, A. M. Lung cancer detection using frequency-domain microwave imaging. Electron. Lett. \n                           51, 740\u2013741 (2015).","journal-title":"Electron. Lett."}],"container-title":["Scientific Reports"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.nature.com\/articles\/s41598-017-00436-w.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.nature.com\/articles\/s41598-017-00436-w","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.nature.com\/articles\/s41598-017-00436-w.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2022,12,22]],"date-time":"2022-12-22T22:11:08Z","timestamp":1671747068000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.nature.com\/articles\/s41598-017-00436-w"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2017,3,22]]},"references-count":24,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2017,12]]}},"alternative-id":["436"],"URL":"https:\/\/doi.org\/10.1038\/s41598-017-00436-w","relation":{},"ISSN":["2045-2322"],"issn-type":[{"value":"2045-2322","type":"electronic"}],"subject":[],"published":{"date-parts":[[2017,3,22]]},"assertion":[{"value":"21 June 2016","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"27 February 2017","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"22 March 2017","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"The authors declare that they have no competing interests.","order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing Interests"}}],"article-number":"304"}}