{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,2,19]],"date-time":"2026-02-19T22:14:28Z","timestamp":1771539268388,"version":"3.50.1"},"reference-count":41,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2017,10,25]],"date-time":"2017-10-25T00:00:00Z","timestamp":1508889600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2017,10,25]],"date-time":"2017-10-25T00:00:00Z","timestamp":1508889600000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Sci Rep"],"abstract":"<jats:title>Abstract<\/jats:title><jats:p>Using a phoropter to measure the refractive error is one of the most commonly used methods by ophthalmologists and optometrists. Here, we demonstrate design and fabrication of a portable automatic phoropter with no need for patient\u2019s feedback. The system is based on three tunable-focus fluidic lenses and thin-film holographic optical elements to perform automatic refractive error measurement and provide a diagnostic prescription without supervision. Three separate lenses are deployed to correct the defocus and astigmatism. The refractive error is measured using a Shack-Hartmann wavefront sensor that calculates the Zernike values of an infrared wavefront emerging from the eye. Holographic optical elements steer the emerging wavefront into the wavefront sensor, while simultaneously providing an unobstructed view for the subject. The power of each lens is controlled by pumping a liquid in and out of the lens chamber using servo motor actuated diaphragm pumps. Spherical and cylindrical correction range of \u221210 to +10 diopters with 0.1 diopter increments is achieved in less than 15\u2009seconds using wavefront sensor feedback to the pumps. This system can be used in rapid screening of large patient populations especially in the developing countries that lack sufficient facilities and specialist doctors.<\/jats:p>","DOI":"10.1038\/s41598-017-14507-5","type":"journal-article","created":{"date-parts":[[2017,10,19]],"date-time":"2017-10-19T09:23:01Z","timestamp":1508404981000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":20,"title":["A new low-cost, compact, auto-phoropter for refractive assessment in developing countries"],"prefix":"10.1038","volume":"7","author":[{"given":"Babak","family":"Amirsolaimani","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Gholam","family":"Peyman","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Jim","family":"Schwiegerling","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Arkady","family":"Bablumyan","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"N.","family":"Peyghambarian","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2017,10,25]]},"reference":[{"key":"14507_CR1","doi-asserted-by":"publisher","first-page":"614","DOI":"10.1136\/bjophthalmol-2011-300539","volume":"96","author":"D Pascolini","year":"2012","unstructured":"Pascolini, D. & Mariotti, S. P. Global estimates of visual impairment: 2010. Br. J. Ophthalmol. 96, 614\u2013618 (2012).","journal-title":"Br. J. Ophthalmol."},{"key":"14507_CR2","doi-asserted-by":"crossref","unstructured":"Vos, T. et al. Global, regional, and national incidence, prevalence, and years lived with disability for 301 acute and chronic diseases and injuries in 188 countries, 1990\u20132013: a systematic analysis for the global burden of disease study 2013. The Lancet 386, 743\u2013800 (2015).","DOI":"10.1016\/S0140-6736(15)60692-4"},{"key":"14507_CR3","unstructured":"World health organization. http:\/\/www.who.int\/mediacentre\/factsheets\/fs282\/en\/ (2014)."},{"key":"14507_CR4","doi-asserted-by":"publisher","first-page":"802","DOI":"10.1001\/jamaophthalmol.2016.1284","volume":"134","author":"R Varma","year":"2016","unstructured":"Varma, R., Vajaranant, T. & Burkemper, B. et al. Visual impairment and blindness in adults in the united states: Demographic and geographic variations from 2015 to 2050. JAMA Ophthalmology 134, 802\u2013809 (2016).","journal-title":"JAMA Ophthalmology"},{"key":"14507_CR5","doi-asserted-by":"publisher","first-page":"728","DOI":"10.2471\/BLT.12.104034","volume":"90","author":"T Fricke","year":"2012","unstructured":"Fricke, T. et al. Global cost of correcting vision impairment from uncorrected refractive error. Bulletin of the World Health Organization 90, 728\u2013738 (2012).","journal-title":"Bulletin of the World Health Organization"},{"key":"14507_CR6","doi-asserted-by":"publisher","first-page":"431","DOI":"10.2471\/BLT.08.055673","volume":"87","author":"T Smith","year":"2009","unstructured":"Smith, T., Frick, K., Holden, B., Fricke, T. & Naidoo, K. Potential lost productivity resulting from the global burden of uncorrected refractive error. Bull. World Heal. Organ. 87, 431\u2013437 (2009).","journal-title":"Bull. World Heal. Organ."},{"key":"14507_CR7","doi-asserted-by":"publisher","first-page":"249","DOI":"10.1111\/j.1442-9071.2010.02361.x","volume":"38","author":"G Brian","year":"2010","unstructured":"Brian, G., Du Toit, R., Ramke, J. & Palagyi, A. Monitoring and evaluation of refractive error and presbyopia for vision 2020. Clin. Exp. Ophthalmol. 38, 249\u2013254 (2010).","journal-title":"Clin. Exp. Ophthalmol."},{"key":"14507_CR8","unstructured":"Contreras, A. & Ackland, P. Spectacle coverage report. Int. Agency for Prev. Blind (2017)."},{"key":"14507_CR9","doi-asserted-by":"publisher","first-page":"1221","DOI":"10.1364\/OE.25.001221","volume":"25","author":"N Hasan","year":"2017","unstructured":"Hasan, N., Banerjee, A., Kim, H. & Mastrangelo, C. H. Tunable-focus lens for adaptive eyeglasses. Opt. Express 25, 1221\u20131233 (2017).","journal-title":"Opt. Express"},{"key":"14507_CR10","doi-asserted-by":"publisher","first-page":"4350","DOI":"10.1364\/BOE.5.004350","volume":"5","author":"M Kim","year":"2014","unstructured":"Kim, M. et al. Miniature objective lens with variable focus for confocal endomicroscopy. Biomed. Opt. Express 5, 4350\u20134361 (2014).","journal-title":"Biomed. Opt. Express"},{"key":"14507_CR11","doi-asserted-by":"publisher","first-page":"3362","DOI":"10.1364\/BOE.6.003362","volume":"6","author":"G Lan","year":"2015","unstructured":"Lan, G., Mauger, T. F. & Li, G. Design of high-performance adaptive objective lens with large optical depth scanning range for ultrabroad near infrared microscopic imaging. Biomed. Opt. Express 6, 3362\u20133377 (2015).","journal-title":"Biomed. Opt. Express"},{"key":"14507_CR12","doi-asserted-by":"publisher","first-page":"2931","DOI":"10.1364\/OE.24.002931","volume":"24","author":"L Li","year":"2016","unstructured":"Li, L., Wang, D., Liu, C. & Wang, Q.-H. Zoom microscope objective using electrowetting lenses. Opt. Express 24, 2931\u20132940 (2016).","journal-title":"Opt. Express"},{"key":"14507_CR13","doi-asserted-by":"publisher","first-page":"1128","DOI":"10.1063\/1.1779954","volume":"85","author":"S Kuiper","year":"2004","unstructured":"Kuiper, S. & Hendriks, B. H. W. Variable-focus liquid lens for miniature cameras. Appl. Phys. Lett. 85, 1128\u20131130 (2004).","journal-title":"Appl. Phys. Lett."},{"key":"14507_CR14","doi-asserted-by":"publisher","first-page":"291","DOI":"10.1364\/OL.33.000291","volume":"33","author":"FS Tsai","year":"2008","unstructured":"Tsai, F. S., Cho, S. H., Lo, Y.-H., Vasko, B. & Vasko, J. Miniaturized universal imaging device using fluidic lens. Opt. Lett. 33, 291\u2013293 (2008).","journal-title":"Opt. Lett."},{"key":"14507_CR15","doi-asserted-by":"publisher","first-page":"515","DOI":"10.1364\/OL.34.000515","volume":"34","author":"R Marks","year":"2009","unstructured":"Marks, R., Mathine, D. L., Peyman, G., Schwiegerling, J. & Peyghambarian, N. Adjustable fluidic lenses for ophthalmic corrections. Opt. Lett. 34, 515\u2013517 (2009).","journal-title":"Opt. Lett."},{"key":"14507_CR16","doi-asserted-by":"publisher","first-page":"739","DOI":"10.1364\/OL.35.000739","volume":"35","author":"R Marks","year":"2010","unstructured":"Marks, R., Mathine, D. L., Peyman, G., Schwiegerling, J. & Peyghambarian, N. Adjustable adaptive compact fluidic phoropter with no mechanical translation of lenses. Opt. Lett. 35, 739\u2013741 (2010).","journal-title":"Opt. Lett."},{"key":"14507_CR17","unstructured":"Peyman, G. External lens adapted to change refractive properties. US Patent 7,993,399 (2011)."},{"key":"14507_CR18","unstructured":"Peyman, G., Peyghambariam, N. & Marks, R. External lens with flexible membranes for automatic correction of the refractive errors of a person. US Patent App. 13\/165,231 (2012)."},{"key":"14507_CR19","doi-asserted-by":"crossref","unstructured":"Mishra, K., van den Ende, D. & Mugele, F. Recent developments in optofluidic lens technology. Micromachines 7 (2016).","DOI":"10.3390\/mi7060102"},{"key":"14507_CR20","doi-asserted-by":"publisher","first-page":"7468","DOI":"10.1364\/OE.19.007468","volume":"19","author":"P Valley","year":"2011","unstructured":"Valley, P. et al. Adjustable hybrid diffractive\/refractive achromatic lens. Opt. Express 19, 7468\u20137479 (2011).","journal-title":"Opt. Express"},{"key":"14507_CR21","doi-asserted-by":"publisher","first-page":"159","DOI":"10.1007\/s101890070029","volume":"3","author":"B Berge","year":"2000","unstructured":"Berge, B. & Peseux, J. Variable focal lens controlled by an external voltage: An application of electrowetting. The Eur. Phys. J. E 3, 159\u2013163 (2000).","journal-title":"The Eur. Phys. J. E"},{"key":"14507_CR22","doi-asserted-by":"crossref","unstructured":"Zhang, W., Zappe, H. & Seifert, A. Wafer-scale fabricated thermo-pneumatically tunable microlenses. Light. Sci. Appl. 3 (2014).","DOI":"10.1038\/lsa.2014.26"},{"key":"14507_CR23","doi-asserted-by":"publisher","first-page":"171111","DOI":"10.1063\/1.2801983","volume":"91","author":"K Campbell","year":"2007","unstructured":"Campbell, K., Fainman, Y. & Groisman, A. Pneumatically actuated adaptive lenses with millisecond response time. Appl. Phys. Lett. 91, 171111 (2007).","journal-title":"Appl. Phys. Lett."},{"key":"14507_CR24","doi-asserted-by":"publisher","first-page":"8031","DOI":"10.1364\/OE.14.008031","volume":"14","author":"H Ren","year":"2006","unstructured":"Ren, H., Fox, D., Anderson, P. A., Wu, B. & Wu, S.-T. Tunable-focus liquid lens controlled using a servo motor. Opt. Express 14, 8031\u20138036 (2006).","journal-title":"Opt. Express"},{"key":"14507_CR25","doi-asserted-by":"publisher","first-page":"3171","DOI":"10.1063\/1.1573337","volume":"82","author":"D-Y Zhang","year":"2003","unstructured":"Zhang, D.-Y., Lien, V., Berdichevsky, Y., Choi, J. & Lo, Y.-H. Fluidic adaptive lens with high focal length tunability. Appl. Phys. Lett. 82, 3171\u20133172 (2003).","journal-title":"Appl. Phys. Lett."},{"key":"14507_CR26","doi-asserted-by":"publisher","first-page":"2858","DOI":"10.1364\/AO.52.002858","volume":"52","author":"N Savidis","year":"2013","unstructured":"Savidis, N., Peyman, G., Peyghambarian, N. & Schwiegerling, J. Nonmechanical zoom system through pressure-controlled tunable fluidic lenses. Appl. Opt. 52, 2858\u20132865 (2013).","journal-title":"Appl. Opt."},{"key":"14507_CR27","doi-asserted-by":"crossref","unstructured":"Blum, M., B\u00fceler, M., Gr\u00e4tzel, C., Giger, J. & Aschwanden, M. Optotune focus tunable lenses and laser speckle reduction based on electroactive polymers. Proc. SPIE 8252, MOEMS and Miniaturized Syst. XI (2016).","DOI":"10.1117\/12.902631"},{"key":"14507_CR28","doi-asserted-by":"publisher","first-page":"2735","DOI":"10.1364\/OL.41.002735","volume":"41","author":"D Kopp","year":"2016","unstructured":"Kopp, D. & Zappe, H. Tubular astigmatism-tunable fluidic lens. Opt. Lett. 41, 2735\u20132738 (2016).","journal-title":"Opt. Lett."},{"key":"14507_CR29","doi-asserted-by":"crossref","unstructured":"Peter Liebetraut, J. L., Petsch, S. & Zappe, H. Elastomeric lenses with tunable astigmatism. Light. Sci. Appl. 2 (2013).","DOI":"10.1038\/lsa.2013.54"},{"key":"14507_CR30","doi-asserted-by":"publisher","first-page":"746","DOI":"10.1364\/OL.26.000746","volume":"26","author":"EJ Fern\u00e1ndez","year":"2001","unstructured":"Fern\u00e1ndez, E. J., Iglesias, I. & Artal, P. Closed-loop adaptive optics in the human eye. Opt. Lett. 26, 746\u2013748 (2001).","journal-title":"Opt. Lett."},{"key":"14507_CR31","doi-asserted-by":"publisher","first-page":"2552","DOI":"10.1364\/JOSAA.15.002552","volume":"15","author":"F Vargas-Martin","year":"1998","unstructured":"Vargas-Martin, F., Prieto, P. M. & Artal, P. Correction of the aberrations in the human eye with a liquid-crystal spatial light modulator: limits to performance. J. Opt. Soc. Am. A 15, 2552\u20132562 (1998).","journal-title":"J. Opt. Soc. Am. A"},{"key":"14507_CR32","doi-asserted-by":"publisher","first-page":"631","DOI":"10.1364\/OE.8.000631","volume":"8","author":"H Hofer","year":"2001","unstructured":"Hofer, H. et al. Improvement in retinal image quality with dynamic correction of the eye\u2019s aberrations. Opt. Express 8, 631\u2013643 (2001).","journal-title":"Opt. Express"},{"key":"14507_CR33","doi-asserted-by":"publisher","first-page":"1388","DOI":"10.1364\/JOSAA.17.001388","volume":"17","author":"PM Prieto","year":"2000","unstructured":"Prieto, P. M., Vargas-Martin, F., Goelz, S. & Artal, P. Analysis of the performance of the hartmann\u2013shack sensor in the human eye. J. Opt. Soc. Am. A 17, 1388\u20131398 (2000).","journal-title":"J. Opt. Soc. Am. A"},{"key":"14507_CR34","doi-asserted-by":"publisher","first-page":"1537","DOI":"10.1364\/OL.27.001537","volume":"27","author":"N Doble","year":"2002","unstructured":"Doble, N. et al. Use of a microelectromechanical mirror for adaptive optics in the human eye. Opt. Lett. 27, 1537\u20131539 (2002).","journal-title":"Opt. Lett."},{"key":"14507_CR35","doi-asserted-by":"publisher","first-page":"1133","DOI":"10.1097\/OPX.0000000000000726","volume":"92","author":"KJ Ciuffreda","year":"2015","unstructured":"Ciuffreda, K. J. & Rosenfield, M. Evaluation of the svone: A handheld, smartphone-based autorefractor. Optom. Vis. Sci. 92, 1133\u20131139 (2015).","journal-title":"Optom. Vis. Sci."},{"key":"14507_CR36","doi-asserted-by":"crossref","unstructured":"Naydenova, I., Nazarova, D. & Babeva, T. Holographic Materials and Optical Systems (InTech, 2017).","DOI":"10.5772\/63255"},{"key":"14507_CR37","doi-asserted-by":"publisher","first-page":"1250","DOI":"10.1364\/JOSAA.24.001250","volume":"24","author":"FC Delori","year":"2007","unstructured":"Delori, F. C., Webb, R. H. & Sliney, D. H. Maximum permissible exposures for ocular safety (ansi 2000), with emphasis on ophthalmic devices. J. Opt. Soc. Am. A 24, 1250\u20131265 (2007).","journal-title":"J. Opt. Soc. Am. A"},{"key":"14507_CR38","doi-asserted-by":"crossref","unstructured":"Qian, X. et al. Characterizing the deformation of the polydimethylsiloxane (pdms) membrane for microfluidic system through image processing. Micromachines 7 (2016).","DOI":"10.3390\/mi7050092"},{"key":"14507_CR39","first-page":"33","volume":"15","author":"BA Holden","year":"2002","unstructured":"Holden, B. A. & Resnikoff, S. The role of optometry in vision 2020. Community Eye Heal. 15, 33\u201336 (2002).","journal-title":"Community Eye Heal."},{"key":"14507_CR40","doi-asserted-by":"publisher","first-page":"2329","DOI":"10.1364\/JOSAA.19.002329","volume":"19","author":"LN Thibos","year":"2002","unstructured":"Thibos, L. N., Hong, X., Bradley, A. & Cheng, X. Statistical variation of aberration structure and image quality in a normal population of healthy eyes. J. Opt. Soc. Am. A 19, 2329\u20132348 (2002).","journal-title":"J. Opt. Soc. Am. A"},{"key":"14507_CR41","doi-asserted-by":"publisher","first-page":"9","DOI":"10.1167\/4.4.9","volume":"4","author":"LN Thibos","year":"2004","unstructured":"Thibos, L. N., Hong, X., Bradley, A. & Applegate, R. A. Accuracy and precision of objective refraction from wavefront aberrations. J. Vis. 4, 9 (2004).","journal-title":"J. Vis."}],"container-title":["Scientific Reports"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.nature.com\/articles\/s41598-017-14507-5.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.nature.com\/articles\/s41598-017-14507-5","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.nature.com\/articles\/s41598-017-14507-5.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,6,26]],"date-time":"2025-06-26T15:33:13Z","timestamp":1750951993000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.nature.com\/articles\/s41598-017-14507-5"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2017,10,25]]},"references-count":41,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2017,12]]}},"alternative-id":["14507"],"URL":"https:\/\/doi.org\/10.1038\/s41598-017-14507-5","relation":{},"ISSN":["2045-2322"],"issn-type":[{"value":"2045-2322","type":"electronic"}],"subject":[],"published":{"date-parts":[[2017,10,25]]},"assertion":[{"value":"30 June 2017","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"11 October 2017","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"25 October 2017","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"The authors declare that they have no competing interests.","order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing Interests"}}],"article-number":"13990"}}