{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,7,15]],"date-time":"2026-07-15T22:55:33Z","timestamp":1784156133127,"version":"3.55.0"},"reference-count":20,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2017,11,6]],"date-time":"2017-11-06T00:00:00Z","timestamp":1509926400000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2017,11,6]],"date-time":"2017-11-06T00:00:00Z","timestamp":1509926400000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Sci Rep"],"abstract":"<jats:title>Abstract<\/jats:title><jats:p>The main cause of acute coronary events, such as thrombosis, is the rupture of atherosclerotic plaques. Typical intravascular optical coherence tomography (IVOCT) imaging systems that utilize a 1.3\u2009\u03bcm swept\u00a0source laser are often used for identifying fibrous cap thickness of plaques,\u00a0yet cannot provide adequate depth penetration to resolve the size of the lipid pool. Here, we present a novel \u00a0IVOCT\u00a0system with a 1.7\u2009\u03bcm center wavelength swept light source that can readily penetrate deeper into\u00a0the tissue because of the longer wavelength and allows for better identification of plaques due to the lipid absorption spectrum at 1.7\u2009\u03bcm. Using this system, we have imaged a human coronary artery to evaluate the performance of the novel OCT system and verified the results by hematoxylin and eosin (H&amp;E) histology. The significantly improved imaging depth and better identification sensitivity suggest that the 1.7\u2009\u03bcm OCT\u00a0system holds great potential \u00a0that can be further translated for <jats:italic>in-vivo<\/jats:italic> applications of atherosclerosis characterization.<\/jats:p>","DOI":"10.1038\/s41598-017-15326-4","type":"journal-article","created":{"date-parts":[[2017,10,31]],"date-time":"2017-10-31T10:43:30Z","timestamp":1509446610000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":51,"title":["Intravascular Optical Coherence Tomography for Characterization of Atherosclerosis with a 1.7 Micron Swept-Source Laser"],"prefix":"10.1038","volume":"7","author":[{"given":"Yan","family":"Li","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-1283-3232","authenticated-orcid":false,"given":"Joseph","family":"Jing","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Emon","family":"Heidari","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-2601-4967","authenticated-orcid":false,"given":"Jiang","family":"Zhu","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yueqiao","family":"Qu","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Zhongping","family":"Chen","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2017,11,6]]},"reference":[{"key":"15326_CR1","doi-asserted-by":"publisher","first-page":"657","DOI":"10.1161\/01.CIR.92.3.657","volume":"92","author":"E Falk","year":"1995","unstructured":"Falk, E., Shah, P. K. & Fuster, V. Coronary plaque disruption. Circulation \n                           92, 657\u2013671 (1995).","journal-title":"Circulation"},{"key":"15326_CR2","doi-asserted-by":"publisher","first-page":"1282","DOI":"10.1161\/ATVBAHA.108.179739","volume":"30","author":"AV Finn","year":"2010","unstructured":"Finn, A. V., Nakano, M., Narula, J., Kolodgie, F. D. & Virmani, R. Concept of Vulnerable\/Unstable Plaque. Arterioscl Throm Vas \n                           30, 1282\u20131292, https:\/\/doi.org\/10.1161\/Atvbaha.108.179739 (2010).","journal-title":"Arterioscl Throm Vas"},{"key":"15326_CR3","doi-asserted-by":"publisher","first-page":"1664","DOI":"10.1161\/01.CIR.0000087480.94275.97","volume":"108","author":"M Naghavi","year":"2003","unstructured":"Naghavi, M. et al. From vulnerable plaque to vulnerable patient - A call for new definitions and risk assessment strategies: Part I. Circulation \n                           108, 1664\u20131672, https:\/\/doi.org\/10.1161\/01.Cir.0000087480.94275.97 (2003).","journal-title":"Circulation"},{"key":"15326_CR4","doi-asserted-by":"publisher","first-page":"56","DOI":"10.1016\/0735-1097(88)90356-7","volume":"12","author":"JA Ambrose","year":"1988","unstructured":"Ambrose, J. A. et al. Angiographic Progression of Coronary-Artery Disease and the Development of Myocardial-Infarction. J Am Coll Cardiol \n                           12, 56\u201362 (1988).","journal-title":"J Am Coll Cardiol"},{"key":"15326_CR5","doi-asserted-by":"publisher","first-page":"1640","DOI":"10.1161\/01.CIR.0000029927.92825.F6","volume":"106","author":"H Yabushita","year":"2002","unstructured":"Yabushita, H. et al. Characterization of human atherosclerosis by optical coherence tomography. Circulation \n                           106, 1640\u20131645 (2002).","journal-title":"Circulation"},{"key":"15326_CR6","doi-asserted-by":"publisher","first-page":"1036","DOI":"10.1364\/BOE.8.001036","volume":"8","author":"Y Li","year":"2017","unstructured":"Li, Y. et al. Fully integrated optical coherence tomography, ultrasound, and indocyanine green-based fluorescence tri-modality system for intravascular imaging. Biomedical optics express \n                           8, 1036\u20131044, https:\/\/doi.org\/10.1364\/BOE.8.001036 (2017).","journal-title":"Biomedical optics express"},{"key":"15326_CR7","doi-asserted-by":"publisher","unstructured":"Li, Y. et al. High-speed intravascular spectroscopic photoacoustic imaging at 1000 A-lines per second with a 0.9-mm diameter catheter. J Biomed Opt \n                           20, https:\/\/doi.org\/10.1117\/1.Jbo.20.6.065006 (2015).","DOI":"10.1117\/1.Jbo.20.6.065006"},{"key":"15326_CR8","doi-asserted-by":"publisher","first-page":"083701","DOI":"10.1063\/1.4929584","volume":"107","author":"Z Piao","year":"2015","unstructured":"Piao, Z. et al. High speed intravascular photoacoustic imaging with fast optical parametric oscillator laser at 1.7 um. Applied physics letters \n                           107, 083701, https:\/\/doi.org\/10.1063\/1.4929584 (2015).","journal-title":"Applied physics letters"},{"key":"15326_CR9","doi-asserted-by":"publisher","first-page":"010512","DOI":"10.1117\/1.3308642","volume":"15","author":"J Yin","year":"2010","unstructured":"Yin, J. et al. Integrated intravascular optical coherence tomography ultrasound imaging system. J Biomed Opt \n                           15, 010512, https:\/\/doi.org\/10.1117\/1.3308642 (2010).","journal-title":"J Biomed Opt"},{"key":"15326_CR10","doi-asserted-by":"publisher","first-page":"101","DOI":"10.1016\/j.jcmg.2013.07.012","volume":"7","author":"J Li","year":"2014","unstructured":"Li, J. et al. Integrated IVUS-OCT for real-time imaging of coronary atherosclerosis. JACC. Cardiovascular imaging \n                           7, 101\u2013103, https:\/\/doi.org\/10.1016\/j.jcmg.2013.07.012 (2014).","journal-title":"JACC. Cardiovascular imaging"},{"key":"15326_CR11","doi-asserted-by":"publisher","first-page":"113","DOI":"10.1161\/01.CIR.0000044384.41037.43","volume":"107","author":"GJ Tearney","year":"2003","unstructured":"Tearney, G. J. et al. Quantification of macrophage content in atherosclerotic plaques by optical coherence tomography. Circulation \n                           107, 113\u2013119, https:\/\/doi.org\/10.1161\/01.Cir.0000044384.41037.43 (2003).","journal-title":"Circulation"},{"key":"15326_CR12","doi-asserted-by":"publisher","first-page":"128","DOI":"10.1136\/hrt.82.2.128","volume":"82","author":"JG Fujimoto","year":"1999","unstructured":"Fujimoto, J. G. et al. High resolution in vivo intra-arterial imaging with optical coherence tomography. Heart \n                           82, 128\u2013133 (1999).","journal-title":"Heart"},{"key":"15326_CR13","doi-asserted-by":"publisher","first-page":"752","DOI":"10.1016\/j.jcmg.2008.06.007","volume":"1","author":"GJ Tearney","year":"2008","unstructured":"Tearney, G. J. et al. Three-Dimensional Coronary Artery Microscopy by Intracoronary Optical Frequency Domain Imaging. Jacc-Cardiovasc Imag \n                           1, 752\u2013761, https:\/\/doi.org\/10.1016\/j.jcmg.2008.06.007 (2008).","journal-title":"Jacc-Cardiovasc Imag"},{"key":"15326_CR14","doi-asserted-by":"publisher","first-page":"2037","DOI":"10.1126\/science.276.5321.2037","volume":"276","author":"GJ Tearney","year":"1997","unstructured":"Tearney, G. J. et al. In vivo endoscopic optical biopsy with optical coherence tomography. Science \n                           276, 2037\u20132039, https:\/\/doi.org\/10.1126\/science.276.5321.2037 (1997).","journal-title":"Science"},{"key":"15326_CR15","doi-asserted-by":"publisher","first-page":"3989","DOI":"10.1364\/BOE.6.003989","volume":"6","author":"M Abran","year":"2015","unstructured":"Abran, M. et al. Validating a bimodal intravascular ultrasound (IVUS) and near-infrared fluorescence (NIRF) catheter for atherosclerotic plaque detection in rabbits. Biomed Opt Express \n                           6, 3989\u20133999, https:\/\/doi.org\/10.1364\/Boe.6.003989 (2015).","journal-title":"Biomed Opt Express"},{"key":"15326_CR16","doi-asserted-by":"publisher","unstructured":"Li, J. W. et al. Ultrafast optical-ultrasonic system and miniaturized catheter for imaging and characterizing atherosclerotic plaques in vivo. Sci Rep-Uk \n                           5, https:\/\/doi.org\/10.1038\/Srep18406 (2015).","DOI":"10.1038\/Srep18406"},{"key":"15326_CR17","first-page":"7","volume":"21","author":"CL Tsai","year":"2001","unstructured":"Tsai, C. L., Chen, J. C. & Wang, W. J. Near-infrared Absorption Property of Biological Soft Tissue Constituents. Journal of Medical and Biological Engineering \n                           21, 7\u201314 (2001).","journal-title":"Journal of Medical and Biological Engineering"},{"key":"15326_CR18","doi-asserted-by":"publisher","unstructured":"Zhu, J. et al. 3D mapping of elastic modulus using shear wave optical micro-elastography. Sci Rep-Uk \n                           6, https:\/\/doi.org\/10.1038\/Srep35499 (2016).","DOI":"10.1038\/Srep35499"},{"key":"15326_CR19","doi-asserted-by":"publisher","first-page":"2099","DOI":"10.1364\/OL.40.002099","volume":"40","author":"J Zhu","year":"2015","unstructured":"Zhu, J. et al. Imaging and characterizing shear wave and shear modulus under orthogonal acoustic radiation force excitation using OCT Doppler variance method. Opt Lett \n                           40, 2099\u20132102, https:\/\/doi.org\/10.1364\/Ol.40.002099 (2015).","journal-title":"Opt Lett"},{"key":"15326_CR20","doi-asserted-by":"publisher","unstructured":"Jing, J. C., Chou, L. D., Su, E. C., Wong, B. J. F. & Chen, Z. P. Anatomically correct visualization of the human upper airway using a high-speed long range optical coherence tomography system with an integrated positioning sensor. Sci Rep-Uk \n                           6, https:\/\/doi.org\/10.1038\/Srep39443 (2016).","DOI":"10.1038\/Srep39443"}],"container-title":["Scientific Reports"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.nature.com\/articles\/s41598-017-15326-4.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.nature.com\/articles\/s41598-017-15326-4","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.nature.com\/articles\/s41598-017-15326-4.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2022,12,23]],"date-time":"2022-12-23T13:04:01Z","timestamp":1671800641000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.nature.com\/articles\/s41598-017-15326-4"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2017,11,6]]},"references-count":20,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2017,12]]}},"alternative-id":["15326"],"URL":"https:\/\/doi.org\/10.1038\/s41598-017-15326-4","relation":{},"ISSN":["2045-2322"],"issn-type":[{"value":"2045-2322","type":"electronic"}],"subject":[],"published":{"date-parts":[[2017,11,6]]},"assertion":[{"value":"20 April 2017","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"25 October 2017","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"6 November 2017","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"Dr. Zhongping Chen has a financial interest in OCT Medical Inc., which, however, does not support this work.","order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing Interests"}}],"article-number":"14525"}}