{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,7]],"date-time":"2026-10-07T22:08:24Z","timestamp":1791410904603,"version":"4.3.3"},"reference-count":51,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2017,11,8]],"date-time":"2017-11-08T00:00:00Z","timestamp":1510099200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2017,11,8]],"date-time":"2017-11-08T00:00:00Z","timestamp":1510099200000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Sci Rep"],"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:p>The aim of this study was to investigate the incidence, predictors and outcome of prosthesis-patient mismatch (PPM) following transcatheter aortic valve replacement (TAVR). A total of 30 articles incorporating 4,691 patients were identified. The pooled incidences of overall, moderate and severe PPM following TAVR were 33.0%, 25.0% and 11.0% respectively. Medtronic CoreValve (MCV) had lower incidence of overall (32% vs: 40%, P\u2009&lt;\u20090.0001) and moderate (23% vs 32%, P\u2009&lt;\u20090.0001) than Edwards Sapien (ESV). PPM was associated with a younger age, smaller annulus diameter and lower left ventricular ejection fraction in comparison with those patients without PPM. Post-dilation (OR, 0.51, 95% CI, 0.38 to 0.68, p\u2009&lt;\u20090.001) during TAVR would decrease the incidence of PPM. Although PPM was common after TAVR, no significant differences were observed both in short- and mid-term all-cause mortality (30\u2009day: OR: 1.1, 95% CI, 0.70 to 1.73 and 2 year: OR: 1.01, 95% CI, 0.74 to 1.38) between patients with PPM and those without PPM. In conclusion, despite being common after TAVR, the incidence of PPM was lower than that of surgical aortic valve replacement (SAVR) and decreased with the experience accumulating, and PPM was not seen to impact on short- and mid-term survival, regardless of its magnitude.<\/jats:p>","DOI":"10.1038\/s41598-017-15396-4","type":"journal-article","created":{"date-parts":[[2017,11,2]],"date-time":"2017-11-02T12:05:18Z","timestamp":1509624318000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":29,"title":["Incidence, Predictors and Outcome of Prosthesis-Patient Mismatch after Transcatheter Aortic Valve Replacement: a Systematic Review and Meta-analysis"],"prefix":"10.1038","volume":"7","author":[{"given":"Yan-biao","family":"Liao","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yi-jian","family":"Li","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Li","family":"Jun-li","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Zhen-gang","family":"Zhao","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Xin","family":"Wei","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jiay-yu","family":"Tsauo","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Tian-yuan","family":"Xiong","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yuan-ning","family":"Xu","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yuan","family":"Feng","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Mao","family":"Chen","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2017,11,8]]},"reference":[{"key":"15396_CR1","doi-asserted-by":"publisher","first-page":"20","DOI":"10.1161\/01.CIR.58.1.20","volume":"58","author":"SH Rahimtoola","year":"1978","unstructured":"Rahimtoola, S. H. The problem of valve prosthesis-patient mismatch. Circulation. \n                           58, 20\u201324 (1978).","journal-title":"Circulation."},{"key":"15396_CR2","doi-asserted-by":"publisher","first-page":"250","DOI":"10.1007\/s11886-011-0172-7","volume":"13","author":"JG Dumesnil","year":"2011","unstructured":"Dumesnil, J. G. & Pibarot, P. Prosthesis-patient mismatch: an update. Curr cardiol rep. \n                           13, 250\u2013257 (2011).","journal-title":"Curr cardiol rep."},{"key":"15396_CR3","doi-asserted-by":"publisher","first-page":"1131","DOI":"10.1016\/S0735-1097(00)00859-7","volume":"36","author":"P Pibarot","year":"2000","unstructured":"Pibarot, P. & Dumesnil, J. G. Hemodynamic and clinical impact of prosthesis-patient mismatch in the aortic valve position and its prevention. J Am Coll Cardiol. \n                           36, 1131\u20131141 (2000).","journal-title":"J Am Coll Cardiol."},{"key":"15396_CR4","doi-asserted-by":"publisher","first-page":"505","DOI":"10.1016\/j.athoracsur.2004.04.042","volume":"79","author":"G Tasca","year":"2005","unstructured":"Tasca, G. et al. Impact of valve prosthesis-patient mismatch on left ventricular mass regression following aortic valve replacement. Ann thorac surg. \n                           79, 505\u2013510 (2005).","journal-title":"Ann thorac surg."},{"key":"15396_CR5","doi-asserted-by":"publisher","first-page":"924","DOI":"10.1016\/j.jcmg.2015.10.026","volume":"9","author":"V Dayan","year":"2016","unstructured":"Dayan, V. et al. Predictors and Outcomes of Prosthesis-Patient Mismatch After Aortic Valve Replacement. JACC Cardiovasc Imaging. \n                           9, 924\u201333 (2016).","journal-title":"JACC Cardiovasc Imaging."},{"key":"15396_CR6","doi-asserted-by":"publisher","first-page":"1518","DOI":"10.1093\/eurheartj\/ehs003","volume":"33","author":"SJ Head","year":"2012","unstructured":"Head, S. J. et al. The impact of prosthesis-patient mismatch on long-term survival after aortic valve replacement: a systematic review and meta-analysis of 34 observational studies comprising 27 186 patients with 133 141 patient-years. Eur Heart J. \n                           33, 1518\u201329 (2012).","journal-title":"Eur Heart J."},{"key":"15396_CR7","doi-asserted-by":"publisher","unstructured":"Sondergaard, L. et al. Two-Year Outcomes in Patients With Severe Aortic Valve Stenosis Randomized to Transcatheter Versus Surgical Aortic Valve Replacement: The All-Comers Nordic Aortic Valve Intervention Randomized Clinical Trial. Circulation Cardiovasc Interv. 9, https:\/\/doi.org\/10.1161\/CIRCINTERVENTIONS.115.003665 (2016).","DOI":"10.1161\/CIRCINTERVENTIONS.115.003665"},{"key":"15396_CR8","doi-asserted-by":"publisher","first-page":"1609","DOI":"10.1056\/NEJMoa1514616","volume":"374","author":"MB Leon","year":"2016","unstructured":"Leon, M. B. et al. Transcatheter or Surgical Aortic-Valve Replacement in Intermediate-Risk Patients. N Engl J Med. \n                           374, 1609\u20131620 (2016).","journal-title":"N Engl J Med."},{"key":"15396_CR9","first-page":"309","volume":"22","author":"S Bleiziffer","year":"2013","unstructured":"Bleiziffer, S. et al. Incidence and impact of prosthesis-patient mismatch after transcatheter aortic valve implantation. J Heart Valve Dis. \n                           22, 309\u2013316 (2013).","journal-title":"J Heart Valve Dis."},{"key":"15396_CR10","doi-asserted-by":"publisher","first-page":"391","DOI":"10.1016\/j.jtcvs.2012.01.043","volume":"145","author":"M Kukucka","year":"2013","unstructured":"Kukucka, M. et al. Patient-prosthesis mismatch after transapical aortic valve implantation: incidence and impact on survival. J Thorac Cardiovasc Surg. \n                           145, 391\u2013397 (2013).","journal-title":"J Thorac Cardiovasc Surg."},{"key":"15396_CR11","doi-asserted-by":"publisher","first-page":"1323","DOI":"10.1016\/j.jacc.2014.06.1195","volume":"64","author":"P Pibarot","year":"2014","unstructured":"Pibarot, P. et al. Incidence and sequelae of prosthesis-patient mismatch in transcatheter versus surgical valve replacement in high-risk patients with severe aortic stenosis: a PARTNER trial cohort\u2013a analysis. J Am Coll Cardiol. \n                           64, 1323\u20131334 (2014).","journal-title":"J Am Coll Cardiol."},{"key":"15396_CR12","doi-asserted-by":"publisher","first-page":"255","DOI":"10.1016\/j.amjcard.2010.02.036","volume":"106","author":"A Tzikas","year":"2010","unstructured":"Tzikas, A. et al. Prosthesis-patient mismatch after transcatheter aortic valve implantation with the medtronic CoreValve system in patients with aortic stenosis. Am J Cardiol. \n                           106, 255\u2013260 (2010).","journal-title":"Am J Cardiol."},{"key":"15396_CR13","doi-asserted-by":"publisher","first-page":"862","DOI":"10.1016\/j.ahj.2010.07.017","volume":"160","author":"MA Sherif","year":"2010","unstructured":"Sherif, M. A. et al. Early hemodynamic and neurohormonal response after transcatheter aortic valve implantation. Am Heart J. \n                           160, 862\u2013869 (2010).","journal-title":"Am Heart J."},{"key":"15396_CR14","doi-asserted-by":"publisher","first-page":"1026","DOI":"10.1016\/j.amjcard.2012.11.063","volume":"111","author":"L Nombela-Franco","year":"2013","unstructured":"Nombela-Franco, L. et al. Comparison of hemodynamic performance of self-expandable CoreValve versus balloon-expandable Edwards SAPIEN aortic valves inserted by catheter for aortic stenosis. Am J Cardiol. \n                           111, 1026\u20131033 (2013).","journal-title":"Am J Cardiol."},{"key":"15396_CR15","doi-asserted-by":"publisher","first-page":"1074","DOI":"10.1016\/j.ijcard.2012.10.062","volume":"167","author":"AJ Munoz-Garcia","year":"2013","unstructured":"Munoz-Garcia, A. J. et al. Incidence and clinical outcome of prosthesis-patient mismatch after transcatheter aortic valve implantation with the CoreValve prosthesis. Int J Cardiol. \n                           167, 1074\u20131076 (2013).","journal-title":"Int J Cardiol."},{"key":"15396_CR16","doi-asserted-by":"publisher","first-page":"1016","DOI":"10.1016\/j.jacc.2011.05.026","volume":"58","author":"D Kalavrouziotis","year":"2011","unstructured":"Kalavrouziotis, D. et al. Transcatheter aortic valve implantation in patients with severe aortic stenosis and small aortic annulus. J Am Coll Cardiol. \n                           58, 1016\u20131024 (2011).","journal-title":"J Am Coll Cardiol."},{"key":"15396_CR17","doi-asserted-by":"publisher","first-page":"857","DOI":"10.1093\/eurheartj\/ehp537","volume":"31","author":"H Jilaihawi","year":"2010","unstructured":"Jilaihawi, H. et al. Prosthesis-patient mismatch after transcatheter aortic valve implantation with the Medtronic-Corevalve bioprosthesis. Eur Heart J. \n                           31, 857\u2013864 (2010).","journal-title":"Eur Heart J."},{"key":"15396_CR18","doi-asserted-by":"publisher","first-page":"926","DOI":"10.1016\/j.ahj.2010.02.030","volume":"159","author":"M Gotzmann","year":"2010","unstructured":"Gotzmann, M., Lindstaedt, M., Bojara, W., Mugge, A. & Germing, A. Hemodynamic results and changes in myocardial function after transcatheter aortic valve implantation. Am Heart J. \n                           159, 926\u2013932 (2010).","journal-title":"Am Heart J."},{"key":"15396_CR19","doi-asserted-by":"publisher","first-page":"248","DOI":"10.1016\/j.jcct.2013.08.005","volume":"7","author":"M Freeman","year":"2013","unstructured":"Freeman, M. et al. Multidetector CT predictors of prosthesis-patient mismatch in transcatheter aortic valve replacement. J Cardiovasc Comput Tomogr. \n                           7, 248\u2013255 (2013).","journal-title":"J Cardiovasc Comput Tomogr."},{"key":"15396_CR20","doi-asserted-by":"publisher","first-page":"1910","DOI":"10.1016\/j.jacc.2011.08.027","volume":"58","author":"SH Ewe","year":"2011","unstructured":"Ewe, S. H. et al. Hemodynamic and clinical impact of prosthesis-patient mismatch after transcatheter aortic valve implantation. J Am Coll Cardiol. \n                           58, 1910\u20131918 (2011).","journal-title":"J Am Coll Cardiol."},{"key":"15396_CR21","doi-asserted-by":"publisher","first-page":"1928","DOI":"10.1161\/CIRCULATIONAHA.109.929893","volume":"122","author":"MA Clavel","year":"2010","unstructured":"Clavel, M. A. et al. Comparison between transcatheter and surgical prosthetic valve implantation in patients with severe aortic stenosis and reduced left ventricular ejection fraction. Circulation. \n                           122, 1928\u20131936 (2010).","journal-title":"Circulation."},{"key":"15396_CR22","doi-asserted-by":"publisher","first-page":"28","DOI":"10.1016\/j.echo.2010.08.027","volume":"24","author":"C Giannini","year":"2011","unstructured":"Giannini, C. et al. Left ventricular reverse remodeling in percutaneous and surgical aortic bioprostheses: an echocardiographic study. J Am Soc Echocardiogr. \n                           24, 28\u201336 (2011).","journal-title":"J Am Soc Echocardiogr."},{"key":"15396_CR23","doi-asserted-by":"publisher","first-page":"414","DOI":"10.1055\/s-0032-1311534","volume":"61","author":"A Van Linden","year":"2013","unstructured":"Van Linden, A. et al. Prosthesis-patient mismatch after transcatheter aortic valve implantation using the Edwards SAPIEN prosthesis. Thorac Cardiovasc Surg. \n                           61, 414\u2013420 (2013).","journal-title":"Thorac Cardiovasc Surg."},{"key":"15396_CR24","doi-asserted-by":"publisher","first-page":"617","DOI":"10.1016\/j.jtcvs.2011.11.004","volume":"143","author":"M Seiffert","year":"2012","unstructured":"Seiffert, M. et al. Impact of patient-prosthesis mismatch after transcatheter aortic valve-in-valve implantation in degenerated bioprostheses. J Thorac Cardiovasc Surg. \n                           143, 617\u2013624 (2012).","journal-title":"J Thorac Cardiovasc Surg."},{"key":"15396_CR25","doi-asserted-by":"publisher","first-page":"501","DOI":"10.1016\/j.recesp.2015.08.018","volume":"69","author":"M Del Trigo","year":"2016","unstructured":"Del Trigo, M. et al. Self-expanding Portico Valve Versus Balloon-expandable SAPIEN XT Valve in Patients With Small Aortic Annuli: Comparison of Hemodynamic Performance. Rev Esp Cardiol (Engl Ed). \n                           69, 501\u2013508 (2016).","journal-title":"Rev Esp Cardiol (Engl Ed)."},{"key":"15396_CR26","doi-asserted-by":"publisher","first-page":"670","DOI":"10.1016\/j.jcin.2014.10.029","volume":"8","author":"V Kamperidis","year":"2015","unstructured":"Kamperidis, V. et al. Surgical sutureless and transcatheter aortic valves: hemodynamic performance and clinical outcomes in propensity score-matched high-risk populations with severe aortic stenosis. JACC Cardiovasc Interv. \n                           8, 670\u2013677 (2015).","journal-title":"JACC Cardiovasc Interv."},{"key":"15396_CR27","doi-asserted-by":"publisher","first-page":"1574","DOI":"10.1016\/j.amjcard.2015.02.059","volume":"115","author":"J Laflamme","year":"2015","unstructured":"Laflamme, J. et al. Incidence and risk factors of hemolysis after transcatheter aortic valve implantation with a balloon-expandable valve. Am J Cardiol. \n                           115, 1574\u20131579 (2015).","journal-title":"Am J Cardiol."},{"key":"15396_CR28","doi-asserted-by":"publisher","unstructured":"Poulin, F. et al. Impact of Prosthesis-Patient Mismatch on Left Ventricular Myocardial Mechanics After Transcatheter Aortic Valve Replacement. J Am Heart Assoc. 5, https:\/\/doi.org\/10.1161\/JAHA.115.002866 (2016).","DOI":"10.1161\/JAHA.115.002866"},{"key":"15396_CR29","doi-asserted-by":"publisher","first-page":"692","DOI":"10.1016\/j.jcin.2015.02.008","volume":"8","author":"T Spangenberg","year":"2015","unstructured":"Spangenberg, T. et al. Treatment of acquired von Willebrand syndrome in aortic stenosis with transcatheter aortic valve replacement. JACC Cardiovasc Interv. \n                           8, 692\u2013700 (2015).","journal-title":"JACC Cardiovasc Interv."},{"key":"15396_CR30","doi-asserted-by":"publisher","first-page":"388","DOI":"10.1016\/j.carrev.2014.10.004","volume":"15","author":"V Subban","year":"2014","unstructured":"Subban, V. et al. Transcatheter valve-in-valve replacement of degenerated bioprosthetic aortic valves: a single Australian Centre experience. Cardiovasc Revasc Med. \n                           15, 388\u2013392 (2014).","journal-title":"Cardiovasc Revasc Med."},{"key":"15396_CR31","doi-asserted-by":"publisher","first-page":"721","DOI":"10.1093\/ejcts\/ezw095","volume":"50","author":"HG Thyregod","year":"2016","unstructured":"Thyregod, H. G. et al. No clinical effect of prosthesis-patient mismatch after transcatheter versus surgical aortic valve replacement in intermediate- and low-risk patients with severe aortic valve stenosis at mid-term follow-up: an analysis from the NOTION trial. Eur J Cardiothorac Surg. \n                           50, 721\u2013728 (2016).","journal-title":"Eur J Cardiothorac Surg."},{"key":"15396_CR32","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1093\/ehjci\/jew039","volume":"18","author":"H Utsunomiya","year":"2017","unstructured":"Utsunomiya, H. et al. Geometric changes in ventriculoaortic complex after transcatheter aortic valve replacement and its association with post-procedural prosthesis-patient mismatch: an intraprocedural 3D-TEE study. Eur Heart J Cardiovasc Imaging. \n                           18, 1\u201310 (2017).","journal-title":"Eur Heart J Cardiovasc Imaging."},{"key":"15396_CR33","doi-asserted-by":"publisher","first-page":"1014","DOI":"10.1016\/j.jtcvs.2015.10.070","volume":"151","author":"GL Zorn 3rd","year":"2016","unstructured":"Zorn, G. L. 3rd et al. Prosthesis-patient mismatch in high-risk patients with severe aortic stenosis: A randomized trial of a self-expanding prosthesis. J Thorac Cardiovasc Surg. \n                           151, 1014\u20131023.e3 (2016).","journal-title":"J Thorac Cardiovasc Surg."},{"key":"15396_CR34","doi-asserted-by":"publisher","first-page":"1892","DOI":"10.1016\/j.jtcvs.2013.07.008","volume":"147","author":"A Finkelstein","year":"2014","unstructured":"Finkelstein, A. et al. Hemodynamic performance and outcome of percutaneous versus surgical stentless bioprostheses for aortic stenosis with anticipated patient-prosthesis mismatch. J Thorac Cardiovasc Surg. \n                           147, 1892\u20131899 (2014).","journal-title":"J Thorac Cardiovasc Surg."},{"key":"15396_CR35","doi-asserted-by":"publisher","first-page":"1982","DOI":"10.1016\/j.athoracsur.2013.02.038","volume":"95","author":"A Unbehaun","year":"2013","unstructured":"Unbehaun, A. et al. New 29-mm balloon-expandable prosthesis for transcatheter aortic valve implantation in large annuli. Ann Thorac Surg. \n                           95, 1982\u20131990 (2013).","journal-title":"Ann Thorac Surg."},{"key":"15396_CR36","doi-asserted-by":"publisher","first-page":"875","DOI":"10.4244\/EIJV12I7A144","volume":"12","author":"T Schmidt","year":"2016","unstructured":"Schmidt, T. et al. Redo TAVI: initial experience at two German centres. EuroIntervention. \n                           12, 875\u201382 (2016).","journal-title":"EuroIntervention."},{"key":"15396_CR37","doi-asserted-by":"publisher","first-page":"1549","DOI":"10.1007\/s10554-014-0510-0","volume":"30","author":"C da Silva","year":"2014","unstructured":"da Silva, C. et al. Prosthesis-patient mismatch after transcatheter aortic valve implantation: impact of 2D-transthoracic echocardiography versus 3D-transesophageal echocardiography. Int J Cardiovasc Imaging. \n                           30, 1549\u201357 (2014).","journal-title":"Int J Cardiovasc Imaging."},{"key":"15396_CR38","doi-asserted-by":"publisher","first-page":"1099","DOI":"10.1136\/heartjnl-2013-305118","volume":"100","author":"JTH Price","year":"2014","unstructured":"Price, J. T. H., Lam, B. K., Lapierre, H., Mesana, T. G. & Ruel, M. The impact of prosthesis-patient mismatch after aortic valve replacement varies according to age at operation. Heart. \n                           100, 1099\u20131106 (2014).","journal-title":"Heart."},{"key":"15396_CR39","doi-asserted-by":"publisher","first-page":"701","DOI":"10.1161\/CIRCINTERVENTIONS.114.001681","volume":"7","author":"J Rodes-Cabau","year":"2014","unstructured":"Rodes-Cabau, J. et al. Impact of aortic annulus size on valve hemodynamics and clinical outcomes after transcatheter and surgical aortic valve replacement: insights from the PARTNER Trial. Circulation Cardiovasc Interv. \n                           7, 701\u2013711 (2014).","journal-title":"Circulation Cardiovasc Interv."},{"key":"15396_CR40","doi-asserted-by":"publisher","first-page":"1335","DOI":"10.1016\/j.jacc.2014.07.952","volume":"64","author":"JJ Popma","year":"2014","unstructured":"Popma, J. J. & Khabbaz, K. Prosthesis-patient mismatch after \u201chigh-risk\u201d aortic valve replacement. J Am Coll Cardiol. \n                           64, 1335\u20131338 (2014).","journal-title":"J Am Coll Cardiol."},{"key":"15396_CR41","doi-asserted-by":"publisher","first-page":"1883","DOI":"10.1016\/j.jacc.2009.01.060","volume":"53","author":"MA Clavel","year":"2009","unstructured":"Clavel, M. A. et al. Comparison of the hemodynamic performance of percutaneous and surgical bioprostheses for the treatment of severe aortic stenosis. J Am Coll Cardiol. \n                           53, 1883\u20131891 (2009).","journal-title":"J Am Coll Cardiol."},{"key":"15396_CR42","doi-asserted-by":"publisher","first-page":"1053","DOI":"10.1016\/j.jcmg.2011.06.021","volume":"4","author":"MA Clavel","year":"2011","unstructured":"Clavel, M. A. et al. Validation and characterization of transcatheter aortic valve effective orifice area measured by Doppler echocardiography. JACC Cardiovasc imaging. \n                           4, 1053\u20131062 (2011).","journal-title":"JACC Cardiovasc imaging."},{"key":"15396_CR43","doi-asserted-by":"publisher","first-page":"791","DOI":"10.1016\/j.jacc.2015.06.026","volume":"66","author":"M Abdel-Wahab","year":"2015","unstructured":"Abdel-Wahab, M. et al. 1-Year Outcomes After Transcatheter Aortic Valve Replacement With Balloon-Expandable Versus Self-Expandable Valves: Results From the CHOICE Randomized Clinical Trial. J Am Coll Cardiol. \n                           66, 791\u2013800 (2015).","journal-title":"J Am Coll Cardiol."},{"key":"15396_CR44","doi-asserted-by":"publisher","first-page":"211","DOI":"10.1093\/icvts\/ivu131","volume":"19","author":"P Donndorf","year":"2014","unstructured":"Donndorf, P. et al. Impact of closed minimal extracorporeal circulation on microvascular tissue perfusion during surgical aortic valve replacement: intravital imaging in a prospective randomized study. Interact Cardiov TH. \n                           19, 211\u2013217 (2014).","journal-title":"Interact Cardiov TH."},{"key":"15396_CR45","doi-asserted-by":"publisher","first-page":"580","DOI":"10.1177\/0267659114567138","volume":"30","author":"M Ozeren","year":"2015","unstructured":"Ozeren, M. et al. Usefulness of elevated red cell distribution width for predicting systemic inflammatory response syndrome after extracorporeal circulation. Perfusion. \n                           30, 580\u2013586 (2015).","journal-title":"Perfusion."},{"key":"15396_CR46","doi-asserted-by":"publisher","first-page":"2605","DOI":"10.1016\/j.jacc.2014.08.052","volume":"64","author":"P Genereux","year":"2014","unstructured":"Genereux, P. et al. Incidence, predictors, and prognostic impact of late bleeding complications after transcatheter aortic valve replacement. J Am Coll Cardiol. \n                           64, 2605\u20132615 (2014).","journal-title":"J Am Coll Cardiol."},{"key":"15396_CR47","doi-asserted-by":"publisher","first-page":"1629","DOI":"10.1016\/j.amjcard.2016.02.036","volume":"117","author":"YB Liao","year":"2016","unstructured":"Liao, Y. B. et al. Meta-Analysis of the Effectiveness and Safety of Transcatheter Aortic Valve Implantation Without Balloon Predilation. Am J Cardiol. \n                           117, 1629\u20131635 (2016).","journal-title":"Am J Cardiol."},{"key":"15396_CR48","doi-asserted-by":"publisher","first-page":"39","DOI":"10.1016\/j.jacc.2008.09.022","volume":"53","author":"D Mohty","year":"2009","unstructured":"Mohty, D. et al. Impact of prosthesis-patient mismatch on long-term survival after aortic valve replacement: influence of age, obesity, and left ventricular dysfunction. J Am Coll Cardiol. \n                           53, 39\u201347 (2009).","journal-title":"J Am Coll Cardiol."},{"key":"15396_CR49","doi-asserted-by":"publisher","DOI":"10.1186\/1745-6215-8-16","volume":"8","author":"JF Tierney","year":"2007","unstructured":"Tierney, J. F., Stewart, L. A., Ghersi, D., Burdett, S. & Sydes, M. R. Practical methods for incorporating summary time-to-event data into meta-analysis. Trials. \n                           8, 16 (2007).","journal-title":"Trials."},{"key":"15396_CR50","doi-asserted-by":"publisher","first-page":"359","DOI":"10.2147\/CLEP.S66677","volume":"6","author":"AV Margulis","year":"2014","unstructured":"Margulis, A. V. et al. Quality assessment of observational studies in a drug-safety systematic review, comparison of two tools: the Newcastle-Ottawa Scale and the RTI item bank. Clin Epidemiol. \n                           6, 359\u2013368 (2014).","journal-title":"Clin Epidemiol."},{"key":"15396_CR51","doi-asserted-by":"publisher","first-page":"2008","DOI":"10.1001\/jama.283.15.2008","volume":"283","author":"DF Stroup","year":"2000","unstructured":"Stroup, D. F. et al. Meta-analysis of observational studies in epidemiology: a proposal for reporting. Meta-analysis Of Observational Studies in Epidemiology (MOOSE) group. Jama. \n                           283, 2008\u20132012 (2000).","journal-title":"Jama."}],"container-title":["Scientific Reports"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.nature.com\/articles\/s41598-017-15396-4.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.nature.com\/articles\/s41598-017-15396-4","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.nature.com\/articles\/s41598-017-15396-4.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2022,12,23]],"date-time":"2022-12-23T08:15:33Z","timestamp":1671783333000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.nature.com\/articles\/s41598-017-15396-4"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2017,11,8]]},"references-count":51,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2017,12]]}},"alternative-id":["15396"],"URL":"https:\/\/doi.org\/10.1038\/s41598-017-15396-4","relation":{},"ISSN":["2045-2322"],"issn-type":[{"value":"2045-2322","type":"electronic"}],"subject":[],"published":{"date-parts":[[2017,11,8]]},"assertion":[{"value":"9 June 2017","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"26 October 2017","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"8 November 2017","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"The authors declare that they have no competing interests.","order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing Interests"}}],"article-number":"15014"}}