{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,12,31]],"date-time":"2025-12-31T03:30:45Z","timestamp":1767151845775,"version":"build-2238731810"},"reference-count":32,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2017,12,1]],"date-time":"2017-12-01T00:00:00Z","timestamp":1512086400000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2017,12,1]],"date-time":"2017-12-01T00:00:00Z","timestamp":1512086400000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Sci Rep"],"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:p>Since there are several casualties due to uncontrolled bleeding resulting from simple injury to surgery, effective styptic or vessel adhesives are important; however, their development is limited by the lack of standardized systems to evaluate potential compounds. The current study outlines the development of an aorta styptic evaluation system, comprising of decellularized swine aorta tissue and a heart pump-mimicking system. Although the cells in the swine aorta were removed, the structural stability of the aorta was sustained due to the maintenance of the extracellular matrix. Using a control adhesive, Cyanoacrylate, the developed model was found to have similar adhesive efficacy to intact aorta. The circulatory-mimicking system was designed to mimic the beat rate and strength of blood-flow from the heart, which was necessary to evaluate the adherent efficacy. The decellularized aorta improves instabilities of intact tissues, which occurs on account of storage and origin, thereby allowing for a more standardized system. The system was able to simulate several symptoms of circulation, according to patient age and health, by adjusting pumping frequency and intensity. Therefore, this system can be used as a standardized evaluation system for screening adhesives. Further, it would also evaluate other medical devices, such as stent or medications.<\/jats:p>","DOI":"10.1038\/s41598-017-16814-3","type":"journal-article","created":{"date-parts":[[2017,11,27]],"date-time":"2017-11-27T06:06:48Z","timestamp":1511762808000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":4,"title":["Artificial controlled model of blood circulation system for adhesive evaluation"],"prefix":"10.1038","volume":"7","author":[{"given":"Sang-Myung","family":"Jung","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Goo Yong","family":"Chung","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Hwa Sung","family":"Shin","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2017,12,1]]},"reference":[{"key":"16814_CR1","first-page":"1383","volume":"61","author":"TB Bruns","year":"2000","unstructured":"Bruns, T. B. & Worthington, J. M. Using tissue adhesive for wound repair: a practical guide to dermabond. Am Fam Physician 61, 1383 (2000).","journal-title":"Am Fam Physician"},{"key":"16814_CR2","doi-asserted-by":"publisher","first-page":"490","DOI":"10.1016\/j.ajem.2007.05.015","volume":"26","author":"AJ Singer","year":"2008","unstructured":"Singer, A. J., Quinn, J. V. & Hollander, J. E. The cyanoacrylate topical skin adhesives. Am J Emerg Med 26, 490 (2008).","journal-title":"Am J Emerg Med"},{"key":"16814_CR3","doi-asserted-by":"publisher","first-page":"2361","DOI":"10.12659\/MSM.894991","volume":"21","author":"W Wojciech","year":"2015","unstructured":"Wojciech, W., Agnieszka, S.-P., Magdalena, B. & Tomasz, G. Experimental Comparison of Efficiency of First Aid Dressings in Burning White Phosphorus on Bacon Model. Med Sci Monit. 21, 2361\u20132366 (2015).","journal-title":"Med Sci Monit."},{"key":"16814_CR4","first-page":"4","volume":"2026","author":"A Mehmet","year":"2016","unstructured":"Mehmet, A. et al. The Effects of Classic Two-Minute Pressing and Commercial Adhesive Bandages on Ecchymosis Development Following Removal of Intravenous Catheters. Emergency Medicine Investigations 2026, 4 (2016).","journal-title":"Emergency Medicine Investigations"},{"key":"16814_CR5","doi-asserted-by":"publisher","first-page":"121","DOI":"10.1080\/08998280.2012.11928805","volume":"25","author":"MB Mina","year":"2012","unstructured":"Mina, M. B. & William, C. R. Fatal aortic rupture from nonpenetrating chest trauma. Proc (Bayl Univ Med Cent) 25, 121\u2013123 (2012).","journal-title":"Proc (Bayl Univ Med Cent)"},{"key":"16814_CR6","doi-asserted-by":"publisher","first-page":"2101","DOI":"10.1056\/NEJMcp1401430","volume":"371","author":"KC Kent","year":"2014","unstructured":"Kent, K. C. Clinical practice. Abdominal aortic aneurysms. N Engl J Med. 371, 2101\u20132108 (2014).","journal-title":"N Engl J Med."},{"key":"16814_CR7","first-page":"218","volume":"6","author":"L Nora","year":"2014","unstructured":"Nora, L. et al. A Blood-Resistant Surgical Glue for Minimally Invasive Repair of Vessels and Heart Defects. Sci Transl Med 6, 218 (2014).","journal-title":"Sci Transl Med"},{"key":"16814_CR8","doi-asserted-by":"publisher","first-page":"687","DOI":"10.1583\/10-3084.1","volume":"17","author":"L Qingsheng","year":"2010","unstructured":"Qingsheng, L. et al. Treatment of Type I Endoleak after Endovascular Repair of Infrarenal Abdominal Aortic Aneurysm: Success of Fibrin Glue Sac Embolization. J Endovasc Ther 17, 687\u2013693 (2010).","journal-title":"J Endovasc Ther"},{"key":"16814_CR9","doi-asserted-by":"crossref","unstructured":"Coulthard, P., Worthington, H., Esposito, M., Elst, M. & Waes, O. J. Tissue adhesives for closure of surgical incisions. Cochrane Database Syst Rev 2 (2004).","DOI":"10.1016\/S0965-206X(04)42005-1"},{"key":"16814_CR10","first-page":"1383","volume":"61","author":"BB Thomas","year":"2000","unstructured":"Thomas, B. B. & Mack, J. W. Using Tissue Adhesive for Wound Repair: A Practical Guide to Dermabond. Am. Fam. Physician 61, 1383\u20131388 (2000).","journal-title":"Am. Fam. Physician"},{"key":"16814_CR11","doi-asserted-by":"publisher","first-page":"169","DOI":"10.1532\/HSF98.20041126","volume":"8","author":"M Kaplan","year":"2005","unstructured":"Kaplan, M. & Baysal, K. In vitro toxicity test of ethyl 2-cyanoacrylate, a tissue adhesive used in cardiovascular surgery, by fibroblast cell culture method. Heart Surg Forum 8, 169\u2013172 (2005).","journal-title":"Heart Surg Forum"},{"key":"16814_CR12","first-page":"6","volume":"11","author":"P Gemma","year":"2016","unstructured":"Gemma, P. et al. Cytotoxicity of Cyanoacrylate-Based Tissue Adhesives and Short-Term Preclinical In Vivo Biocompatibility in Abdominal Hernia Repair. PLoS One 11, 6 (2016).","journal-title":"PLoS One"},{"key":"16814_CR13","doi-asserted-by":"publisher","first-page":"326","DOI":"10.1002\/jbm.a.32788","volume":"94","author":"X Mo","year":"2010","unstructured":"Mo, X., Iwata, H. & Ikada, Y. A tissue adhesives evaluated in vitro and in vivo analysis. J Biomed Mater Res A 94, 326\u2013332 (2010).","journal-title":"J Biomed Mater Res A"},{"key":"16814_CR14","doi-asserted-by":"publisher","first-page":"280","DOI":"10.7205\/MILMED-D-09-00185","volume":"175","author":"JG Clay","year":"2010","unstructured":"Clay, J. G., Grayson, J. K. & Zierold, D. Comparative testing of new hemostatic agents in a swine model of extremity arterial and venous hemorrhage. Mil Med. 175, 280\u2013284 (2010).","journal-title":"Mil Med."},{"key":"16814_CR15","doi-asserted-by":"publisher","first-page":"450","DOI":"10.1097\/TA.0b013e3181ac0c99","volume":"67","author":"BS Kheirabadi","year":"2009","unstructured":"Kheirabadi, B. S., Scherer, M. R., Estep, J. S., Dubick, M. A. & Holcomb, J. B. Determination of efficacy of new hemostatic dressings in a model of extremity arterial hemorrhage in swine. J Trauma. 67, 450\u2013459 (2009).","journal-title":"J Trauma."},{"key":"16814_CR16","doi-asserted-by":"publisher","first-page":"1055","DOI":"10.1038\/ajh.2012.87","volume":"25","author":"K Georges","year":"2012","unstructured":"Georges, K. et al. Aortic Pulse Pressure Is Associated With the Localization of Coronary Artery Disease Based on Coronary Flow Lateralization. Am J Hypertens. 25, 1055\u20131063 (2012).","journal-title":"Am J Hypertens."},{"key":"16814_CR17","doi-asserted-by":"publisher","first-page":"121","DOI":"10.1161\/01.HYP.0000135448.73199.75","volume":"44","author":"ES Michel","year":"2004","unstructured":"Michel, E. S. Peripheral Pulse Pressure, Large Arteries, and Microvessels. Hypertens. 44, 121\u2013122 (2004).","journal-title":"Hypertens."},{"key":"16814_CR18","doi-asserted-by":"publisher","first-page":"1241","DOI":"10.1016\/j.actbio.2010.11.017","volume":"7","author":"B Mendoza-Novelo","year":"2011","unstructured":"Mendoza-Novelo, B. et al. Decellularization of pericardial tissue and its impact on tensile viscoelasticity and glycosaminoglycan content. Acta Biomater. 7, 1241\u20131248 (2011).","journal-title":"Acta Biomater."},{"key":"16814_CR19","unstructured":"Richard, E. K. Cardiovascular Physiology Concepts 2nd ed. (ed. Crystal. T.) 21\u201326 (Wolters Kluwer Health, 2011)."},{"key":"16814_CR20","doi-asserted-by":"publisher","first-page":"1488","DOI":"10.1007\/s10439-015-1332-5","volume":"43","author":"J Tong","year":"2015","unstructured":"Tong, J. & Holzapfel, G. A. Structure, Mechanics, and Histology of Intraluminal Thrombi in Abdominal Aortic Aneurysms. Ann Biomed Eng. 43, 1488\u20131501 (2015).","journal-title":"Ann Biomed Eng."},{"key":"16814_CR21","doi-asserted-by":"publisher","first-page":"957","DOI":"10.1152\/physrev.00041.2008","volume":"89","author":"EW Jessica","year":"2009","unstructured":"Jessica, E. W. & Robert, P. M. Vascular Extracellular Matrix and Arterial Mechanics. Physiol Rev. 89, 957\u2013989 (2009).","journal-title":"Physiol Rev."},{"key":"16814_CR22","doi-asserted-by":"publisher","first-page":"1731","DOI":"10.1016\/j.bpj.2012.03.041","volume":"102","author":"MB Jan-Willem","year":"2012","unstructured":"Jan-Willem, M. B., Brian, A. A., Jan, H. N. L. & Tjerk, H. O. Mechanical Properties of the Extracellular Matrix of the Aorta Studied by Enzymatic Treatments. Biophys J. 102, 1731\u20131737 (2012).","journal-title":"Biophys J."},{"key":"16814_CR23","first-page":"7","volume":"11","author":"SM Krane","year":"1983","unstructured":"Krane, S. M. & Amento, E. P. Cellular interactions and control of collagenase secretion in the synovium. J Rheumatol Suppl. 11, 7\u201312 (1983).","journal-title":"J Rheumatol Suppl."},{"key":"16814_CR24","doi-asserted-by":"crossref","unstructured":"Sacks, M. S. Biaxial mechanical evaluation of biological materials in Cardiovascular Soft Tissue Mechanic. (ed. Stephen, C. & Jay, D. H.) 199\u2013246 (Springer Science & Business Media, 2001).","DOI":"10.1007\/0-306-48389-0_7"},{"key":"16814_CR25","doi-asserted-by":"publisher","unstructured":"Ellen, M. G., Jessica, C. M., James, S. B. & C. Peter, W. The structure and micromechanics of elastic tissue. Interface Focus 4, https:\/\/doi.org\/10.1098\/rsfs.2013.0058 (2014).","DOI":"10.1098\/rsfs.2013.0058"},{"key":"16814_CR26","first-page":"155","volume":"2","author":"PE Ali","year":"2009","unstructured":"Ali, P. E. Mechanical Properties of Normal and Diseased Cerebrovascular System. J Vasc Interv Neurol. 2, 155\u2013162 (2009).","journal-title":"J Vasc Interv Neurol."},{"key":"16814_CR27","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1016\/j.actbio.2008.09.013","volume":"5","author":"FB Stephen","year":"2009","unstructured":"Stephen, F. B., Donald, O. F. & Thomas, W. G. Extracellular matrix as a biological scaffold material: Structure and function. Acta Biomater 5, 1\u201313 (2009).","journal-title":"Acta Biomater"},{"key":"16814_CR28","doi-asserted-by":"publisher","first-page":"462","DOI":"10.1016\/j.biotechadv.2013.12.012","volume":"32","author":"WC Christina","year":"2014","unstructured":"Christina, W. C., Loran, D. S. & Eben, A. Decellularized Tissue and Cell-Derived Extracellular Matrices as Scaffolds for Orthopaedic Tissue Engineering. Biotechnol Adv. 32, 462\u2013484 (2014).","journal-title":"Biotechnol Adv."},{"key":"16814_CR29","doi-asserted-by":"publisher","first-page":"276","DOI":"10.1089\/ten.tec.2012.0760","volume":"20","author":"J Burk","year":"2014","unstructured":"Burk, J. et al. Freeze-thaw cycles enhance decellularization of large tendons. Tissue Eng Part C Methods. 20, 276\u2013284 (2014).","journal-title":"Tissue Eng Part C Methods."},{"key":"16814_CR30","doi-asserted-by":"publisher","first-page":"13","DOI":"10.1186\/s12896-017-0329-6","volume":"17","author":"PR Susanne","year":"2017","unstructured":"Susanne, P. R. et al. Automated freeze-thaw cycles for decellularization of tendon tissue - a pilot study. BMC Biotech 17, 13 (2017).","journal-title":"BMC Biotech"},{"key":"16814_CR31","doi-asserted-by":"publisher","first-page":"30","DOI":"10.1016\/j.ebiom.2016.02.023","volume":"5","author":"MS Courtney","year":"2016","unstructured":"Courtney, M. S., Mandy, B. E., James, J. H., Michael, L. S. & Gretchen, J. M. Modeling Barrier Tissues In Vitro: Methods, Achievements, and Challenges. EBioMedicine. 5, 30\u201339 (2016).","journal-title":"EBioMedicine."},{"key":"16814_CR32","unstructured":"Simel, D. Approach to the patient: history and physical examination. In Cecil Medicine. 25th ed. (ed. Goldman L.) 5\u201312 (Elsevier Saunders; 2016)."}],"updated-by":[{"DOI":"10.1038\/s41598-018-24839-5","type":"correction","label":"Correction","source":"publisher","updated":{"date-parts":[[2018,4,19]],"date-time":"2018-04-19T00:00:00Z","timestamp":1524096000000}}],"container-title":["Scientific Reports"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.nature.com\/articles\/s41598-017-16814-3.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.nature.com\/articles\/s41598-017-16814-3","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.nature.com\/articles\/s41598-017-16814-3.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2022,12,23]],"date-time":"2022-12-23T09:42:09Z","timestamp":1671788529000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.nature.com\/articles\/s41598-017-16814-3"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2017,12,1]]},"references-count":32,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2017,12]]}},"alternative-id":["16814"],"URL":"https:\/\/doi.org\/10.1038\/s41598-017-16814-3","relation":{},"ISSN":["2045-2322"],"issn-type":[{"value":"2045-2322","type":"electronic"}],"subject":[],"published":{"date-parts":[[2017,12,1]]},"assertion":[{"value":"7 June 2017","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"17 November 2017","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"1 December 2017","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"19 April 2018","order":4,"name":"change_date","label":"Change Date","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"Correction","order":5,"name":"change_type","label":"Change Type","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"A correction to this article has been published and is linked from the HTML and PDF versions of this paper. The error has not been fixed in the paper.","order":6,"name":"change_details","label":"Change Details","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"The authors declare that they have no competing interests.","order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing Interests"}}],"article-number":"16720"}}