{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,5,16]],"date-time":"2026-05-16T00:04:16Z","timestamp":1778889856009,"version":"3.51.4"},"reference-count":18,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2018,1,10]],"date-time":"2018-01-10T00:00:00Z","timestamp":1515542400000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2018,1,10]],"date-time":"2018-01-10T00:00:00Z","timestamp":1515542400000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Sci Rep"],"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:p>Daily alignment of the microscope is a prerequisite to reaching optimal lens conditions for high resolution imaging in cryo-EM. In this study, we have investigated how image astigmatism varies with the imaging conditions (e.g. defocus, magnification). We have found that the large change of defocus\/magnification between visual correction of astigmatism and subsequent data collection tasks, or during data collection, will inevitably result in undesirable astigmatism in the final images. The dependence of astigmatism on the imaging conditions varies significantly from time to time, so that it cannot be reliably compensated by pre-calibration of the microscope. Based on these findings, we recommend that the same magnification and the median defocus of the intended defocus range for final data collection are used in the objective lens astigmatism correction task during microscope alignment and in the focus mode of the iterative low-dose imaging. It is also desirable to develop a fast, accurate method that can perform dynamic correction of the astigmatism for different intended defocuses during automated imaging. Our findings also suggest that the slope of astigmatism changes caused by varying defocuses can be used as a convenient measurement of objective lens rotation symmetry and potentially an acceptance test of new electron microscopes.<\/jats:p>","DOI":"10.1038\/s41598-017-18820-x","type":"journal-article","created":{"date-parts":[[2018,1,4]],"date-time":"2018-01-04T10:29:56Z","timestamp":1515061796000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":5,"title":["Defocus and magnification dependent variation of TEM image astigmatism"],"prefix":"10.1038","volume":"8","author":[{"given":"Rui","family":"Yan","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Kunpeng","family":"Li","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-1292-2411","authenticated-orcid":false,"given":"Wen","family":"Jiang","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2018,1,10]]},"reference":[{"key":"18820_CR1","doi-asserted-by":"publisher","first-page":"407","DOI":"10.1016\/0304-3991(94)90176-7","volume":"55","author":"K Ishizuka","year":"1994","unstructured":"Ishizuka, K. Coma-Free Alignment of a High-Resolution Electron-Microscope with 3-Fold Astigmatism. Ultramicroscopy 55, 407\u2013418 (1994).","journal-title":"Ultramicroscopy"},{"key":"18820_CR2","doi-asserted-by":"publisher","first-page":"49","DOI":"10.1016\/S0304-3991(78)80006-0","volume":"3","author":"F Zemlin","year":"1978","unstructured":"Zemlin, F., Weiss, K., Schiske, P., Kunath, W. & Herrmann, K.-H. Coma-free alignment of high resolution electron microscopes with the aid of optical diffractograms. Ultramicroscopy 3, 49\u201360 (1978).","journal-title":"Ultramicroscopy"},{"key":"18820_CR3","doi-asserted-by":"crossref","unstructured":"Thon, F. Phase Contrast Electron Microscopy in Electron Microscopy in Material Science (ed Valdre, U.) 571\u2013625 (Academic Press, 1971).","DOI":"10.1016\/B978-0-12-780584-9.50021-0"},{"key":"18820_CR4","doi-asserted-by":"publisher","first-page":"231","DOI":"10.1016\/S0076-6879(10)81010-9","volume":"481","author":"JC Sun","year":"2010","unstructured":"Sun, J. C. & Li, H. L. How to Operate a Cryo-Electron Microscope. Methods in Enzymology, Vol 481. Cryo-Em, Part a - Sample Preparation and Data Collection 481, 231\u2013249 (2010).","journal-title":"Cryo-Em, Part a - Sample Preparation and Data Collection"},{"key":"18820_CR5","doi-asserted-by":"publisher","first-page":"330","DOI":"10.1038\/nprot.2007.474","volume":"3","author":"RA Grassucci","year":"2008","unstructured":"Grassucci, R. A., Taylor, D. & Frank, J. Visualization of macromolecular complexes using cryo-electron microscopy with FEI Tecnai transmission electron microscopes. Nat Protoc 3, 330\u2013339 (2008).","journal-title":"Nat Protoc"},{"key":"18820_CR6","doi-asserted-by":"publisher","first-page":"438","DOI":"10.1016\/j.cell.2015.03.050","volume":"161","author":"Y Cheng","year":"2015","unstructured":"Cheng, Y., Grigorieff, N., Penczek, P. A. & Walz, T. A primer to single-particle cryo-electron microscopy. Cell 161, 438\u2013449 (2015).","journal-title":"Cell"},{"key":"18820_CR7","doi-asserted-by":"publisher","first-page":"35","DOI":"10.1016\/S0076-6879(10)82002-6","volume":"482","author":"PA Penczek","year":"2010","unstructured":"Penczek, P. A. Image restoration in cryo-electron microscopy. Methods Enzymol 482, 35\u201372 (2010).","journal-title":"Methods Enzymol"},{"key":"18820_CR8","doi-asserted-by":"publisher","first-page":"197","DOI":"10.1006\/jsbi.1997.3845","volume":"118","author":"J Zhu","year":"1997","unstructured":"Zhu, J., Penczek, P. A., Schroder, R. & Frank, J. Three-dimensional reconstruction with contrast transfer function correction from energy-filtered cryoelectron micrographs: procedure and application to the 70S Escherichia coli ribosome. J Struct Biol 118, 197\u2013219 (1997).","journal-title":"J Struct Biol"},{"key":"18820_CR9","doi-asserted-by":"publisher","first-page":"210","DOI":"10.1016\/j.jsb.2016.11.001","volume":"197","author":"R Yan","year":"2017","unstructured":"Yan, R., Li, K. & Jiang, W. Real-time detection and single-pass minimization of TEM objective lens astigmatism. J Struct Biol 197, 210\u2013219 (2017).","journal-title":"J Struct Biol"},{"key":"18820_CR10","unstructured":"Hawkes, P. W. The Beginnings of electron microscopy., (Academic Press, 2013)."},{"key":"18820_CR11","doi-asserted-by":"crossref","unstructured":"Rai-Choudhury, P. Handbook of microlithography, micromachining, and microfabrication. (SPIE Optical Engineering Press, 1997).","DOI":"10.1117\/3.2265071"},{"key":"18820_CR12","doi-asserted-by":"publisher","first-page":"136","DOI":"10.1016\/j.jsb.2012.12.006","volume":"181","author":"J Vargas","year":"2013","unstructured":"Vargas, J. et al. FASTDEF: fast defocus and astigmatism estimation for high-throughput transmission electron microscopy. J Struct Biol 181, 136\u2013148 (2013).","journal-title":"J Struct Biol"},{"key":"18820_CR13","doi-asserted-by":"publisher","first-page":"6","DOI":"10.1016\/j.ultramic.2013.05.001","volume":"134","author":"J Barthel","year":"2013","unstructured":"Barthel, J. & Thust, A. On the optical stability of high-resolution transmission electron microscopes. Ultramicroscopy 134, 6\u201317 (2013).","journal-title":"Ultramicroscopy"},{"key":"18820_CR14","doi-asserted-by":"publisher","first-page":"348","DOI":"10.1016\/j.jsb.2015.04.003","volume":"190","author":"R Marabini","year":"2015","unstructured":"Marabini, R. et al. CTF Challenge: Result summary. J Struct Biol 190, 348\u2013359 (2015).","journal-title":"J Struct Biol"},{"key":"18820_CR15","doi-asserted-by":"publisher","first-page":"387","DOI":"10.1038\/nmeth.3806","volume":"13","author":"A Iudin","year":"2016","unstructured":"Iudin, A., Korir, P. K., Salavert-Torres, J., Kleywegt, G. J. & Patwardhan, A. EMPIAR: a public archive for raw electron microscopy image data. Nat Methods 13, 387\u2013388 (2016).","journal-title":"Nat Methods"},{"key":"18820_CR16","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1016\/j.jsb.2015.11.003","volume":"193","author":"K Zhang","year":"2016","unstructured":"Zhang, K. Gctf: Real-time CTF determination and correction. J Struct Biol 193, 1\u201312 (2016).","journal-title":"J Struct Biol"},{"key":"18820_CR17","doi-asserted-by":"publisher","first-page":"207","DOI":"10.1016\/j.jsb.2016.06.003","volume":"195","author":"G Yu","year":"2016","unstructured":"Yu, G. et al. An algorithm for estimation and correction of anisotropic magnification distortion of cryo-EM images without need of pre-calibration. J Struct Biol 195, 207\u2013215 (2016).","journal-title":"J Struct Biol"},{"key":"18820_CR18","doi-asserted-by":"publisher","first-page":"204","DOI":"10.1016\/j.jsb.2015.08.006","volume":"192","author":"T Grant","year":"2015","unstructured":"Grant, T. & Grigorieff, N. Automatic estimation and correction of anisotropic magnification distortion in electron microscopes. J Struct Biol 192, 204\u2013208 (2015).","journal-title":"J Struct Biol"}],"container-title":["Scientific Reports"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.nature.com\/articles\/s41598-017-18820-x.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.nature.com\/articles\/s41598-017-18820-x","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.nature.com\/articles\/s41598-017-18820-x.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2022,12,23]],"date-time":"2022-12-23T21:02:00Z","timestamp":1671829320000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.nature.com\/articles\/s41598-017-18820-x"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2018,1,10]]},"references-count":18,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2018,12]]}},"alternative-id":["18820"],"URL":"https:\/\/doi.org\/10.1038\/s41598-017-18820-x","relation":{"has-preprint":[{"id-type":"doi","id":"10.1101\/138255","asserted-by":"object"}]},"ISSN":["2045-2322"],"issn-type":[{"value":"2045-2322","type":"electronic"}],"subject":[],"published":{"date-parts":[[2018,1,10]]},"assertion":[{"value":"8 September 2017","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"18 December 2017","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"10 January 2018","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"The authors declare that they have no competing interests.","order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing Interests"}}],"article-number":"344"}}