{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,11,5]],"date-time":"2026-11-05T20:51:08Z","timestamp":1793911868342,"version":"4.8.0"},"reference-count":30,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2018,3,2]],"date-time":"2018-03-02T00:00:00Z","timestamp":1519948800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2018,3,2]],"date-time":"2018-03-02T00:00:00Z","timestamp":1519948800000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Sci Rep"],"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:p>\n                    The presence of external elements is a major limitation of current hearing aids and cochlear implants, as they lead to discomfort and inconvenience. Totally implantable hearing devices have been proposed as a solution to mitigate these constraints, which has led to challenges in designing implantable sensors. This work presents a feasibility analysis of a MEMS piezoelectric accelerometer coupled to the ossicular chain as an alternative sensor. The main requirements of the sensor include small size, low internal noise, low power consumption, and large bandwidth. Different designs of MEMS piezoelectric accelerometers were modeled using Finite Element (FE) method, as well as optimized for high net charge sensitivity. The best design, a 2 \u00d7 2\u2009mm\n                    <jats:sup>2<\/jats:sup>\n                    annular configuration with a 500\u2009nm thick Aluminum Nitride (AlN) layer was selected for fabrication. The prototype was characterized, and its charge sensitivity and spectral acceleration noise were found to be with good agreement to the FE model predictions. Weak coupling between a middle ear FE model and the prototype was considered, resulting in equivalent input noise (EIN) lower than 60\u2009dB sound pressure level between 600\u2009Hz and 10\u2009kHz. These results are an encouraging proof of concept for the development of MEMS piezoelectric accelerometers as implantable sensors for hearing devices.\n                  <\/jats:p>","DOI":"10.1038\/s41598-018-22219-7","type":"journal-article","created":{"date-parts":[[2018,2,26]],"date-time":"2018-02-26T06:21:03Z","timestamp":1519626063000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":54,"title":["On the design of a MEMS piezoelectric accelerometer coupled to the middle ear as an implantable sensor for hearing devices"],"prefix":"10.1038","volume":"8","author":[{"given":"A. L.","family":"Gesing","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"F. D. P.","family":"Alves","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"S.","family":"Paul","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"J. A.","family":"Cordioli","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2018,3,2]]},"reference":[{"key":"22219_CR1","unstructured":"World Health Organization. Deafness and hearing loss. World Health Organization Fact Sheets, http:\/\/who.int\/mediacentre\/factsheets\/fs300\/en\/ (2017)."},{"key":"22219_CR2","doi-asserted-by":"publisher","first-page":"114","DOI":"10.1097\/MAO.0b013e31814b242f","volume":"29","author":"R Briggs","year":"2008","unstructured":"Briggs, R. et al. Initial clinical experience with a totally implantable cochlear implant research device. Otology & Neurotology 29, 114\u2013119 (2008).","journal-title":"Otology & Neurotology"},{"key":"22219_CR3","doi-asserted-by":"publisher","first-page":"221","DOI":"10.1016\/j.otc.2011.09.002","volume":"45","author":"ML Carlson","year":"2012","unstructured":"Carlson, M. L., Driscoll, C. L. W., Gifford, R. H. & McMenomey, S. O. Cochlear implantation: current and future device options. Otolaryngologic Clinics of North America 45, 221\u2013248 (2012).","journal-title":"Otolaryngologic Clinics of North America"},{"key":"22219_CR4","doi-asserted-by":"publisher","first-page":"277","DOI":"10.1109\/TBCAS.2009.2032267","volume":"3","author":"WH Ko","year":"2009","unstructured":"Ko, W. H. et al. Studies of MEMS acoustic sensors as implantable microphones for totally implantable hearing-aid systems. IEEE Transactions on Biomedical Circuits and Systems 3, 277\u2013285 (2009).","journal-title":"IEEE Transactions on Biomedical Circuits and Systems"},{"key":"22219_CR5","doi-asserted-by":"publisher","first-page":"1399","DOI":"10.1016\/j.medengphy.2013.03.012","volume":"35","author":"M Sachse","year":"2013","unstructured":"Sachse, M., Hortschitz, W., Stifter, M., Steiner, H. & Sauter, T. Design of an implantable seismic sensor placed on the ossicular chain. Medical engineering & physics 35, 1399\u20131405 (2013).","journal-title":"Medical engineering & physics"},{"key":"22219_CR6","doi-asserted-by":"publisher","first-page":"206","DOI":"10.1016\/j.otohns.2007.03.012","volume":"137","author":"HA Jenkins","year":"2007","unstructured":"Jenkins, H. A. et al. US Phase I preliminary results of use of the otologics MET fully-implantable ossicular stimulator. Otolaryngology-Head and Neck Surgery 137, 206\u2013212 (2007).","journal-title":"Otolaryngology-Head and Neck Surgery"},{"key":"22219_CR7","doi-asserted-by":"publisher","first-page":"904","DOI":"10.1016\/j.otohns.2004.05.027","volume":"131","author":"DA Chen","year":"2004","unstructured":"Chen, D. A. et al. Phase 1 clinical trial results of the Envoy System: a totally implantable middle ear device for sensorineural hearing loss. Otolaryngology-Head and Neck Surgery 131, 904\u2013916 (2004).","journal-title":"Otolaryngology-Head and Neck Surgery"},{"key":"22219_CR8","doi-asserted-by":"publisher","first-page":"939","DOI":"10.1007\/s10544-007-9072-4","volume":"9","author":"WT Park","year":"2007","unstructured":"Park, W. T. et al. Ultraminiature encapsulated accelerometers as a fully implantable sensor for implantable hearing aids. Biomedical microdevices 9, 939\u2013949 (2007).","journal-title":"Biomedical microdevices"},{"key":"22219_CR9","doi-asserted-by":"crossref","unstructured":"Zurcher, M. A. et al. MEMS middle ear acoustic sensor for a fully implantable cochlear prosthesis. In Proc. of the 20th Int. Conf. on Micro Electro Mechanical Systems. 11\u201314 (2007).","DOI":"10.1109\/MEMSYS.2007.4433039"},{"key":"22219_CR10","doi-asserted-by":"publisher","first-page":"214","DOI":"10.1109\/JSSC.2014.2355822","volume":"50","author":"M Yip","year":"2015","unstructured":"Yip, M., Jin, R., Nakajima, H. H., Stankovic, K. M. & Chandrakasan, A. P. A fully-implantable cochlear implant SoC with piezoelectric middle-ear sensor and arbitrary waveform neural stimulation. IEEE J. Solid-State Circuits 50, 214\u2013229 (2015).","journal-title":"IEEE J. Solid-State Circuits"},{"key":"22219_CR11","doi-asserted-by":"crossref","unstructured":"Beker, L., Zorlu, O., Goksu, N. & Kulah, H. Stimulating auditory nerve with MEMS harvesters for fully implantable and self-powered cochlear implants. In Proc. of Eurosensors XXVII: The 17th Int. Conf. on Solid-State Sensors, Actuators and Microsystems. 1663\u20131666 (2013).","DOI":"10.1109\/Transducers.2013.6627104"},{"key":"22219_CR12","first-page":"584","volume":"1","author":"A Koyuncuo\u00c4\u0178lu","year":"2017","unstructured":"Koyuncuo\u00c4\u0178lu, A. et al. Bulk PZT cantilever based MEMS acoustic transducer for cochlear implant applications. Multidisciplinary Digital Publishing Institute Proceedings 1, 584 (2017).","journal-title":"Multidisciplinary Digital Publishing Institute Proceedings"},{"key":"22219_CR13","doi-asserted-by":"publisher","first-page":"1248","DOI":"10.1080\/00016489.2016.1201590","volume":"136","author":"XH Jia","year":"2016","unstructured":"Jia, X. H. et al. A new floating piezoelectric microphone for the implantable middle ear microphone in experimental studies. Acta Oto-Laryngologica 136, 1248\u20131254 (2016).","journal-title":"Acta Oto-Laryngologica"},{"key":"22219_CR14","doi-asserted-by":"publisher","first-page":"1506","DOI":"10.1002\/lary.23618","volume":"123","author":"N Gao","year":"2013","unstructured":"Gao, N. et al. The frequency response of a floating piezoelectric microphone for the implantable middle ear microphone. The Laryngoscope 123, 1506\u20131513 (2013).","journal-title":"The Laryngoscope"},{"key":"22219_CR15","unstructured":"Kaajakari, V. Practical MEMS: Design of microsystems, accelerometers, gyroscopes, RF MEMS, optical MEMS, and microfluidic systems. (Small Gear Pub, 2009)."},{"key":"22219_CR16","doi-asserted-by":"publisher","first-page":"433","DOI":"10.1109\/JMEMS.2003.811749","volume":"12","author":"LP Wang","year":"2003","unstructured":"Wang, L. P. et al. Design, fabrication, and measurement of high-sensitivity piezoelectric microelectromechanical systems accelerometers. Journal of Microelectromechanical Systems 12, 433\u2013439 (2003).","journal-title":"Journal of Microelectromechanical Systems"},{"key":"22219_CR17","doi-asserted-by":"publisher","first-page":"434","DOI":"10.1016\/j.sna.2005.03.014","volume":"121","author":"AT Kollias","year":"2005","unstructured":"Kollias, A. T. & Avaritsiotis, J. N. A study on the performance of bending mode piezoelectric accelerometers. Sensors and Actuators A: Physical 121, 434\u2013442 (2005).","journal-title":"Sensors and Actuators A: Physical"},{"key":"22219_CR18","doi-asserted-by":"crossref","unstructured":"Hindrichsen, C. C. et al. Circular piezoelectric accelerometer for high band width application. Sensors 475\u2013478 (IEEE, 2005)","DOI":"10.1109\/ICSENS.2009.5398277"},{"key":"22219_CR19","doi-asserted-by":"crossref","unstructured":"Gerfers, F. et al. Sub-\u03bcg ultra-low-noise MEMS accelerometers based on CMOS-compatible piezoelectric AlN thin films. Solid-State Sensors, Actuators and Microsystems Conference 1191\u20131194 (IEEE, 2007)","DOI":"10.1109\/SENSOR.2007.4300349"},{"key":"22219_CR20","doi-asserted-by":"publisher","first-page":"246","DOI":"10.1106\/8BFB-GC8P-XQ47-YCQ0","volume":"11","author":"J Sirohi","year":"2000","unstructured":"Sirohi, J. & Chopra, I. Fundamental understanding of piezoelectric strain sensors. Journal of Intelligent Material Systems and Structures 11, 246\u2013257 (2000).","journal-title":"Journal of Intelligent Material Systems and Structures"},{"key":"22219_CR21","unstructured":"Cowen, A., Glukh, K. & Hardy, B. PiezoMUMPs Design Handbook. (MEMSCAP Inc., 2014)."},{"key":"22219_CR22","doi-asserted-by":"publisher","first-page":"1235","DOI":"10.1109\/JSEN.2005.859256","volume":"5","author":"FA Levinzon","year":"2005","unstructured":"Levinzon, F. A. Noise of piezoelectric accelerometer with integral FET amplifier. IEEE Sensors Journal 5, 1235\u20131242 (2005).","journal-title":"IEEE Sensors Journal"},{"key":"22219_CR23","doi-asserted-by":"publisher","first-page":"108","DOI":"10.1109\/JSEN.2003.820366","volume":"4","author":"FA Levinzon","year":"2004","unstructured":"Levinzon, F. A. Fundamental noise limit of piezoelectric accelerometer. IEEE Sensors Journal 4, 108\u2013111 (2004).","journal-title":"IEEE Sensors Journal"},{"key":"22219_CR24","doi-asserted-by":"crossref","unstructured":"Arora, J. S. Introduction to Optimum Design. (Elsevier and Academic Press, 2004).","DOI":"10.1016\/B978-012064155-0\/50012-4"},{"key":"22219_CR25","unstructured":"Mathworks I. Genetic algorithm options. Mathworks Online Documentation, https:\/\/www.mathworks.com\/help\/gads\/genetic-algorithm-options.html (2016)."},{"key":"22219_CR26","doi-asserted-by":"crossref","unstructured":"Haupt, R. L. & Haupt, S. E. Practical Genetic Algorithms. (John Wiley, 2004).","DOI":"10.1002\/0471671746"},{"key":"22219_CR27","doi-asserted-by":"publisher","first-page":"1830","DOI":"10.1121\/1.4933817","volume":"138","author":"FS Pires","year":"2015","unstructured":"Pires, F. S., Arellano, D. C., Paul, S. & Cordioli, J. A. On material properties and damping models for the dynamic modeling of the human middle ear by means of the finite element method. The Journal of the Acoustical Society of America 138, 1830\u20131831 (2015).","journal-title":"The Journal of the Acoustical Society of America"},{"key":"22219_CR28","doi-asserted-by":"publisher","first-page":"137","DOI":"10.1016\/j.heares.2013.01.007","volume":"301","author":"J Chung","year":"2013","unstructured":"Chung, J. et al. Optimal ossicular site for maximal vibration transmissions to coupled transducers. Hearing Research 301, 137\u2013145 (2013).","journal-title":"Hearing Research"},{"key":"22219_CR29","doi-asserted-by":"publisher","first-page":"595","DOI":"10.1016\/j.proeng.2011.12.148","volume":"25","author":"M Sachse","year":"2011","unstructured":"Sachse, M. et al. A middle ear microphone design based on the physiology of the human ear. Procedia Engineering 25, 595\u2013598 (2011).","journal-title":"Procedia Engineering"},{"key":"22219_CR30","doi-asserted-by":"publisher","first-page":"030034","DOI":"10.1121\/1.4799235","volume":"19","author":"W Conklin","year":"2013","unstructured":"Conklin, W. Leveraging microelectromechanical microphones inherent matching to reduce noise using multiple microphone elements. Proceedings of Meetings on Acoustics ICA2013 19, 030034 (2013).","journal-title":"Proceedings of Meetings on Acoustics ICA2013"}],"container-title":["Scientific Reports"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.nature.com\/articles\/s41598-018-22219-7.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.nature.com\/articles\/s41598-018-22219-7","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.nature.com\/articles\/s41598-018-22219-7.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,7,1]],"date-time":"2025-07-01T21:02:41Z","timestamp":1751403761000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.nature.com\/articles\/s41598-018-22219-7"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2018,3,2]]},"references-count":30,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2018,12]]}},"alternative-id":["22219"],"URL":"https:\/\/doi.org\/10.1038\/s41598-018-22219-7","relation":{},"ISSN":["2045-2322"],"issn-type":[{"value":"2045-2322","type":"electronic"}],"subject":[],"published":{"date-parts":[[2018,3,2]]},"assertion":[{"value":"8 January 2018","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"19 February 2018","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"2 March 2018","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"The authors declare no competing interests.","order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing Interests"}}],"article-number":"3920"}}