{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,17]],"date-time":"2026-08-17T21:50:31Z","timestamp":1787003431030,"version":"build-2736575974"},"reference-count":17,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2018,4,9]],"date-time":"2018-04-09T00:00:00Z","timestamp":1523232000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2018,4,9]],"date-time":"2018-04-09T00:00:00Z","timestamp":1523232000000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Sci Rep"],"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:p>\n                    Susceptibility artifacts caused by stainless steel orthodontic appliances (braces) pose significant challenges in clinical brain MRI examinations. We introduced field correction device (FCD) utilizing permanent magnets to cancel the induced B\n                    <jats:sub>0<\/jats:sub>\n                    inhomogeneity and mitigate geometric distortions in MRI. We evaluated a prototype FCD using a 3D-printed head phantom in this proof of concept study. The phantom was compartmented into anterior frontal lobe, temporal lobe, fronto-parieto-occipital lobe, basal ganglia and thalami, brain stem, and cerebellum and had built-in orthogonal gridlines to facilitate the quantification of geometric distortions and volume obliterations. Stainless steel braces were mounted on dental models of three different sizes with total induced magnetic moment 0.15 to 0.17\u2009A\u00b7m\n                    <jats:sup>2<\/jats:sup>\n                    . With braces B\n                    <jats:sub>0<\/jats:sub>\n                    standard deviation (SD) ranged from 2.8 to 3.7 ppm in the temporal and anterior frontal lobes vs. 0.2 to 0.3 ppm without braces. The volume of brain regions in diffusion weighted imaging was obliterated by 32\u201338% with braces vs. 0% without braces in the cerebellum. With the FCD the SD of B\n                    <jats:sub>0<\/jats:sub>\n                    ranged from 0.3 to 1.2 ppm, and obliterated volume ranged from 0 to 6% in the corresponding brain areas. These results showed that FCD can effectively decrease susceptibility artifacts from orthodontic appliances.\n                  <\/jats:p>","DOI":"10.1038\/s41598-018-23890-6","type":"journal-article","created":{"date-parts":[[2018,4,3]],"date-time":"2018-04-03T23:22:18Z","timestamp":1522797738000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":5,"title":["Correcting B0 Field Distortions in MRI Caused by Stainless Steel Orthodontic Appliances at 1.5 T Using Permanent Magnets \u2013 A Head Phantom Study"],"prefix":"10.1038","volume":"8","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-5649-2900","authenticated-orcid":false,"given":"Zhiyue J.","family":"Wang","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yong Jong","family":"Park","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Michael C.","family":"Morriss","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-5233-4422","authenticated-orcid":false,"given":"Youngseob","family":"Seo","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Trung","family":"Nguyen","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Rami R.","family":"Hallac","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ana","family":"Nava","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-3605-6076","authenticated-orcid":false,"given":"Rajiv","family":"Chopra","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-7714-7989","authenticated-orcid":false,"given":"Yonatan","family":"Chatzinoff","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Khyana","family":"Price","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Nancy K.","family":"Rollins","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2018,4,9]]},"reference":[{"key":"23890_CR1","doi-asserted-by":"publisher","first-page":"139","DOI":"10.1148\/radiology.147.1.6828719","volume":"147","author":"PF New","year":"1983","unstructured":"New, P. F. et al. Potential hazards and artifacts of ferromagnetic and nonferromagnetic surgical and dental materials and devices in nuclear magnetic resonance imaging. Radiology 147, 139\u2013148 (1983).","journal-title":"Radiology"},{"key":"23890_CR2","first-page":"354","volume":"12","author":"C Devge","year":"1997","unstructured":"Devge, C., Tjellstrom, A. & Nellstrom, H. Magnetic resonance imaging in patients with dental implants: a clinical report. Int J Oral Maxillofac Implants 12, 354\u2013359 (1997).","journal-title":"Int J Oral Maxillofac Implants"},{"key":"23890_CR3","first-page":"E278","volume":"14","author":"AL Costa","year":"2009","unstructured":"Costa, A. L. et al. Artifacts in brain magnetic resonance imaging due to metallic dental objects. Medicina oral, patologia oral y cirugia bucal 14, E278\u2013282 (2009).","journal-title":"Medicina oral, patologia oral y cirugia bucal"},{"key":"23890_CR4","doi-asserted-by":"publisher","first-page":"547","DOI":"10.2214\/AJR.11.7364","volume":"197","author":"BA Hargreaves","year":"2011","unstructured":"Hargreaves, B. A. et al. Metal-induced artifacts in MRI. AJR Am J Roentgenol 197, 547\u2013555, https:\/\/doi.org\/10.2214\/AJR.11.7364 (2011).","journal-title":"AJR Am J Roentgenol"},{"key":"23890_CR5","doi-asserted-by":"publisher","first-page":"906","DOI":"10.1002\/mrm.10298","volume":"48","author":"JL Wilson","year":"2002","unstructured":"Wilson, J. L., Jenkinson, M. & Jezzard, P. Optimization of static field homogeneity in human brain using diamagnetic passive shims. Magn Reson Med 48, 906\u2013914, https:\/\/doi.org\/10.1002\/mrm.10298 (2002).","journal-title":"Magn Reson Med"},{"key":"23890_CR6","doi-asserted-by":"publisher","first-page":"243","DOI":"10.1002\/mrm.20365","volume":"53","author":"JJ Hsu","year":"2005","unstructured":"Hsu, J. J. & Glover, G. H. Mitigation of susceptibility-induced signal loss in neuroimaging using localized shim coils. Magn Reson Med 53, 243\u2013248, https:\/\/doi.org\/10.1002\/mrm.20365 (2005).","journal-title":"Magn Reson Med"},{"key":"23890_CR7","doi-asserted-by":"publisher","first-page":"7","DOI":"10.1118\/1.596162","volume":"15","author":"ZH Cho","year":"1988","unstructured":"Cho, Z. H., Kim, D. J. & Kim, Y. K. Total inhomogeneity correction including chemical shifts and susceptibility by view angle tilting. Med Phys 15, 7\u201311 (1988).","journal-title":"Med Phys"},{"key":"23890_CR8","doi-asserted-by":"publisher","first-page":"699","DOI":"10.1148\/radiographics.20.3.g00ma10699","volume":"20","author":"RV Olsen","year":"2000","unstructured":"Olsen, R. V. et al. Metal artifact reduction sequence: early clinical applications. Radiographics 20, 699\u2013712 (2000).","journal-title":"Radiographics"},{"key":"23890_CR9","doi-asserted-by":"publisher","first-page":"66","DOI":"10.1002\/mrm.21967","volume":"62","author":"W Lu","year":"2009","unstructured":"Lu, W., Pauly, K. B., Gold, G. E., Pauly, J. M. & Hargreaves, B. A. SEMAC: Slice Encoding for Metal Artifact Correction in MRI. Magn Reson Med 62, 66\u201376, https:\/\/doi.org\/10.1002\/mrm.21967 (2009).","journal-title":"Magn Reson Med"},{"key":"23890_CR10","unstructured":"Wang, Z. J., Park, Y. J., Seo, Y., Morriss, M. C. & Rollins, N. K. Reducing Brain MRI Artifacts Caused by Ferromagnetic Orthodontic Appliances Using Permanent Magnets. In International Society of Magnetic Resonance in Medicine (Singapore, 2016)."},{"key":"23890_CR11","unstructured":"Wang, Z. J., Park, Y. J., Seo, Y., Morriss, M. C. & Rollins, N. K. In Radiological Society of North America (Chicago, Illinois, 2015)."},{"key":"23890_CR12","unstructured":"Wang, Z. J. et al. In Radiological Society of North America (Chicago, Illinois, 2016)."},{"key":"23890_CR13","doi-asserted-by":"publisher","first-page":"5871","DOI":"10.1118\/1.4930796","volume":"42","author":"ZJ Wang","year":"2015","unstructured":"Wang, Z. J., Rollins, N. K., Liang, H. & Park, Y. J. Induced magnetic moment in stainless steel components of orthodontic appliances in 1.5 T MRI scanners. Med Phys 42, 5871\u20135878, https:\/\/doi.org\/10.1118\/1.4930796 (2015).","journal-title":"Med Phys"},{"key":"23890_CR14","doi-asserted-by":"crossref","unstructured":"Coey, J. M. D. Rare-Earth Iron Permanent Magnets (Monographs on the Physics and Chemistry of Materials). (Oxford Science Publications, 1996).","DOI":"10.1093\/oso\/9780198517924.001.0001"},{"key":"23890_CR15","doi-asserted-by":"publisher","first-page":"907","DOI":"10.1016\/j.jpeds.2010.01.009","volume":"156","author":"JD Rollins","year":"2010","unstructured":"Rollins, J. D., Collins, J. S. & Holden, K. R. United States head circumference growth reference charts: birth to 21 years. J Pediatr 156, 907\u2013913, 913 e901-902, https:\/\/doi.org\/10.1016\/j.jpeds.2010.01.009 (2010).","journal-title":"J Pediatr"},{"key":"23890_CR16","doi-asserted-by":"publisher","first-page":"870","DOI":"10.1161\/STR.0b013e318284056a","volume":"44","author":"EC Jauch","year":"2013","unstructured":"Jauch, E. C. et al. Guidelines for the early management of patients with acute ischemic stroke: a guideline for healthcare professionals from the American Heart Association\/American Stroke Association. Stroke; a journal of cerebral circulation 44, 870\u2013947, https:\/\/doi.org\/10.1161\/STR.0b013e318284056a (2013).","journal-title":"Stroke; a journal of cerebral circulation"},{"key":"23890_CR17","doi-asserted-by":"publisher","first-page":"E117","DOI":"10.3174\/ajnr.A3690","volume":"34","author":"M Wintermark","year":"2013","unstructured":"Wintermark, M. et al. Imaging recommendations for acute stroke and transient ischemic attack patients: A joint statement by the American Society of Neuroradiology, the American College of Radiology, and the Society of NeuroInterventional Surgery. AJNR Am J Neuroradiol 34, E117\u2013127, https:\/\/doi.org\/10.3174\/ajnr.A3690 (2013).","journal-title":"AJNR Am J Neuroradiol"}],"container-title":["Scientific Reports"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.nature.com\/articles\/s41598-018-23890-6.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.nature.com\/articles\/s41598-018-23890-6","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.nature.com\/articles\/s41598-018-23890-6.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2024,7,5]],"date-time":"2024-07-05T14:22:44Z","timestamp":1720189364000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.nature.com\/articles\/s41598-018-23890-6"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2018,4,9]]},"references-count":17,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2018,12]]}},"alternative-id":["23890"],"URL":"https:\/\/doi.org\/10.1038\/s41598-018-23890-6","relation":{},"ISSN":["2045-2322"],"issn-type":[{"value":"2045-2322","type":"electronic"}],"subject":[],"published":{"date-parts":[[2018,4,9]]},"assertion":[{"value":"8 January 2018","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"22 March 2018","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"9 April 2018","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"The authors declare no competing interests.","order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing Interests"}}],"article-number":"5706"}}