{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,28]],"date-time":"2026-08-28T20:21:03Z","timestamp":1787948463924,"version":"build-2784847793"},"reference-count":56,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2018,5,8]],"date-time":"2018-05-08T00:00:00Z","timestamp":1525737600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2018,5,8]],"date-time":"2018-05-08T00:00:00Z","timestamp":1525737600000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Sci Rep"],"abstract":"<jats:title>Abstract<\/jats:title><jats:p>Neuromodulation induced by transcranial electric stimulation (TES) exhibited promising potential for clinical practice. However, the underlying mechanisms remain subject of research. The combination of TES and electroencephalography (EEG) offers great potential for investigating these mechanisms and brain function in general, especially when performed simultaneously. In conventional applications, the combination of EEG and TES suffers from limitations on the electrode level (gel for electrode-skin interface) and the usability level (preparation time, reproducibility of positioning). To overcome these limitations, we designed a bifunctional cap for simultaneous TES\u2013EEG applications. We used novel electrode materials, namely textile stimulation electrodes and dry EEG electrodes integrated in a flexible textile cap. We verified the functionality of this cap by analysing the effect of TES on visual evoked potentials (VEPs). In accordance with previous reports using standard TES, the amplitude of the N75 component was significantly decreased post-stimulation, indicating the feasibility of using this novel flexible cap for simultaneous TES and EEG. Further, we found a significant reduction of the P100 component only during TES, indicating a different brain modulation effect during and after TES. In conclusion, the novel bifunctional cap offers a novel tool for simultaneous TES\u2013EEG applications in clinical research, therapy monitoring and closed-loop stimulation.<\/jats:p>","DOI":"10.1038\/s41598-018-25562-x","type":"journal-article","created":{"date-parts":[[2018,5,2]],"date-time":"2018-05-02T13:29:26Z","timestamp":1525267766000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":34,"title":["Novel bifunctional cap for simultaneous electroencephalography and transcranial electrical stimulation"],"prefix":"10.1038","volume":"8","author":[{"given":"Sophia","family":"Wunder","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-7315-1115","authenticated-orcid":false,"given":"Alexander","family":"Hunold","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-9196-0717","authenticated-orcid":false,"given":"Patrique","family":"Fiedler","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Falk","family":"Schlegelmilch","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Klaus","family":"Schellhorn","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-3871-2890","authenticated-orcid":false,"given":"Jens","family":"Haueisen","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2018,5,8]]},"reference":[{"key":"25562_CR1","doi-asserted-by":"publisher","first-page":"206","DOI":"10.1016\/j.brs.2008.06.004","volume":"1","author":"MA Nitsche","year":"2008","unstructured":"Nitsche, M. A. et al. Transcranial direct current stimulation: State of the art 2008. Brain Stimulation 1, 206\u2013223 (2008).","journal-title":"Brain Stimulation"},{"key":"25562_CR2","doi-asserted-by":"publisher","first-page":"29","DOI":"10.1007\/s13295-014-0056-6","volume":"5","author":"W Paulus","year":"2014","unstructured":"Paulus, W. Transcranial brain stimulation: potential and limitations. e-Neuroforum 5, 29\u201336 (2014).","journal-title":"e-Neuroforum"},{"key":"25562_CR3","doi-asserted-by":"publisher","first-page":"14147","DOI":"10.1523\/JNEUROSCI.4248-08.2008","volume":"28","author":"D Terney","year":"2008","unstructured":"Terney, D., Chaieb, L., Moliadze, V., Antal, A. & Paulus, W. Increasing human brain excitability by transcranial high-frequency random noise stimulation. Journal of Neuroscience 28, 14147\u201314155 (2008).","journal-title":"Journal of Neuroscience"},{"key":"25562_CR4","doi-asserted-by":"publisher","first-page":"15416","DOI":"10.1523\/JNEUROSCI.2002-11.2011","volume":"31","author":"A Fertonani","year":"2011","unstructured":"Fertonani, A., Pirulli, C. & Miniussi, C. Random noise stimulation improves neuroplasticity in perceptual learning. Journal of Neuroscience 31, 15416\u201315423 (2011).","journal-title":"Journal of Neuroscience"},{"key":"25562_CR5","doi-asserted-by":"publisher","first-page":"175","DOI":"10.1016\/j.brs.2011.03.002","volume":"5","author":"AR Brunoni","year":"2012","unstructured":"Brunoni, A. R. et al. Clinical research with transcranial direct current stimulation (tDCS): challenges and future directions. Brain Stimulation 5, 175\u2013195 (2012).","journal-title":"Brain Stimulation"},{"key":"25562_CR6","doi-asserted-by":"publisher","first-page":"641","DOI":"10.1016\/j.brs.2016.06.004","volume":"9","author":"M Bikson","year":"2016","unstructured":"Bikson, M. et al. Safety of Transcranial Direct Current Stimulation: Evidence Based Update 2016. Brain Stimulation 9, 641\u2013661 (2016).","journal-title":"Brain Stimulation"},{"key":"25562_CR7","doi-asserted-by":"publisher","first-page":"208","DOI":"10.1016\/j.brainresbull.2007.01.004","volume":"72","author":"C Poreisz","year":"2007","unstructured":"Poreisz, C., Boros, K., Antal, A. & Paulus, W. Safety aspects of transcranial direct current stimulation concerning healthy subjects and patients. Brain Research Bulletin 72, 208\u2013214 (2007).","journal-title":"Brain Research Bulletin"},{"key":"25562_CR8","doi-asserted-by":"publisher","first-page":"261","DOI":"10.1113\/jphysiol.2001.013364","volume":"540","author":"S Durand","year":"2002","unstructured":"Durand, S., Fromy, B., Bouy\u00e9, P., Saumet, J. L. & Abraham, P. Vasodilatation in response to repeated anodal current application in the human skin relies on aspirin-sensitive mechanisms. Journal of Physiology 540, 261\u2013269 (2002).","journal-title":"Journal of Physiology"},{"key":"25562_CR9","doi-asserted-by":"publisher","first-page":"188","DOI":"10.1016\/j.jneumeth.2010.05.007","volume":"190","author":"P Minhas","year":"2010","unstructured":"Minhas, P. et al. Electrodes for high-definition transcutaneous DC stimulation for applications in drug delivery and electrotherapy, including tDCS. Journal of Neuroscience Methods 190, 188\u2013197 (2010).","journal-title":"Journal of Neuroscience Methods"},{"key":"25562_CR10","doi-asserted-by":"publisher","first-page":"872","DOI":"10.1212\/01.WNL.0000152986.07469.E9","volume":"64","author":"MB Iyer","year":"2005","unstructured":"Iyer, M. B. et al. Safety and cognitive effect of frontal DC brain polarization in healthy individuals. Neurology 64, 872\u2013875 (2005).","journal-title":"Neurology"},{"key":"25562_CR11","doi-asserted-by":"crossref","unstructured":"DaSilva, A. F., Volz, M. S., Bikson, M. & Fregni, F. Electrode positioning and montage in transcranial direct current stimulation. Journal of Visualized Experiments (2011).","DOI":"10.3791\/2744"},{"key":"25562_CR12","doi-asserted-by":"publisher","first-page":"317","DOI":"10.3389\/fnhum.2013.00317","volume":"7","author":"A Antal","year":"2013","unstructured":"Antal, A. & Paulus, W. Transcranial alternating current stimulation (tACS). Frontiers in Human Neuroscience 7, 317 (2013).","journal-title":"Frontiers in Human Neuroscience"},{"key":"25562_CR13","first-page":"38","volume":"14","author":"TL Huang","year":"2008","unstructured":"Huang, T. L. & Charyton, C. A comprehensive review of the psychological effects of brainwave entrainment. Alternative Therapies in Health and Medicine 14, 38\u201349 (2008).","journal-title":"Alternative Therapies in Health and Medicine"},{"key":"25562_CR14","doi-asserted-by":"publisher","first-page":"2789","DOI":"10.1016\/j.neuropsychologia.2010.06.002","volume":"48","author":"KS Utz","year":"2010","unstructured":"Utz, K. S., Dimova, V., Oppenlander, K. & Kerkhoff, G. Electrified minds: transcranial direct current stimulation (tDCS) and galvanic vestibular stimulation (GVS) as methods of non-invasive brain stimulation in neuropsychology\u2013a review of current data and future implications. Neuropsychologia 48, 2789\u20132810 (2010).","journal-title":"Neuropsychologia"},{"key":"25562_CR15","doi-asserted-by":"publisher","first-page":"88","DOI":"10.5498\/wjp.v5.i1.88","volume":"5","author":"G Tortella","year":"2015","unstructured":"Tortella, G., Casati, R. & Aparicio, L. V. M. Transcranial direct current stimulation in psychiatric disorders. World Journal of Psychiatry 5, 88\u2013102 (2015).","journal-title":"World Journal of Psychiatry"},{"key":"25562_CR16","doi-asserted-by":"publisher","first-page":"490","DOI":"10.1093\/brain\/awh369","volume":"128","author":"F Hummel","year":"2005","unstructured":"Hummel, F. Effects of non-invasive cortical stimulation on skilled motor function in chronic stroke. Brain 128, 490\u2013499 (2005).","journal-title":"Brain"},{"key":"25562_CR17","doi-asserted-by":"publisher","first-page":"957","DOI":"10.1007\/s00115-012-3566-x","volume":"83","author":"FC Hummel","year":"2012","unstructured":"Hummel, F. C. & Gerloff, C. Transcranial brain stimulation after stroke. Der Nervenarzt 83, 957\u2013965 (2012).","journal-title":"Der Nervenarzt"},{"key":"25562_CR18","doi-asserted-by":"publisher","first-page":"1571","DOI":"10.1001\/archneur.65.12.1571","volume":"65","author":"G Schlaug","year":"2008","unstructured":"Schlaug, G., Renga, V. & Nair, D. Transcranial direct current stimulation in stroke recovery. Archives of Neurology 65, 1571\u20131576 (2008).","journal-title":"Archives of Neurology"},{"key":"25562_CR19","doi-asserted-by":"publisher","first-page":"819","DOI":"10.1161\/STROKEAHA.110.600288","volume":"42","author":"J Fridriksson","year":"2011","unstructured":"Fridriksson, J., Richardson, J. D., Baker, J. M. & Rorden, C. Transcranial direct current stimulation improves naming reaction time in fluent aphasia: a double-blind, sham-controlled study. Stroke 42, 819\u2013821 (2011).","journal-title":"Stroke"},{"key":"25562_CR20","doi-asserted-by":"publisher","first-page":"203","DOI":"10.1111\/j.1399-5618.2006.00291.x","volume":"8","author":"F Fregni","year":"2006","unstructured":"Fregni, F. et al. Treatment of major depression with transcranial direct current stimulation. Bipolar Disorders 8, 203\u2013204 (2006).","journal-title":"Bipolar Disorders"},{"key":"25562_CR21","doi-asserted-by":"publisher","first-page":"14","DOI":"10.1016\/j.expneurol.2009.03.038","volume":"219","author":"MA Nitsche","year":"2009","unstructured":"Nitsche, M. A., Boggio, P. S., Fregni, F. & Pascual-Leone, A. Treatment of depression with transcranial direct current stimulation (tDCS): a review. Experimental Neurology 219, 14\u201319 (2009).","journal-title":"Experimental Neurology"},{"key":"25562_CR22","doi-asserted-by":"publisher","first-page":"646","DOI":"10.1002\/da.22079","volume":"30","author":"L Valiengo","year":"2013","unstructured":"Valiengo, L. et al. The sertraline versus electrical current therapy for treating depression clinical study (select-TDCS): results of the crossover and follow-up phases. Depression and Anxiety 30, 646\u2013653 (2013).","journal-title":"Depression and Anxiety"},{"key":"25562_CR23","doi-asserted-by":"publisher","first-page":"1791","DOI":"10.1017\/S0033291711003059","volume":"42","author":"UG Kalu","year":"2012","unstructured":"Kalu, U. G., Sexton, C. E., Loo, C. K. & Ebmeier, K. P. Transcranial direct current stimulation in the treatment of major depression: a meta-analysis. Psychological Medicine 42, 1791\u20131800 (2012).","journal-title":"Psychological Medicine"},{"key":"25562_CR24","doi-asserted-by":"publisher","first-page":"23","DOI":"10.1007\/s00221-005-2334-6","volume":"166","author":"F Fregni","year":"2005","unstructured":"Fregni, F. et al. Anodal transcranial direct current stimulation of prefrontal cortex enhances working memory. Experimental Brain Research 166, 23\u201330 (2005).","journal-title":"Experimental Brain Research"},{"key":"25562_CR25","doi-asserted-by":"publisher","first-page":"9985","DOI":"10.1523\/JNEUROSCI.2725-04.2004","volume":"24","author":"L Marshall","year":"2004","unstructured":"Marshall, L., M\u00f6lle, M., Hallschmid, M. & Born, J. Transcranial Direct Current Stimulation during Sleep Improves Declarative Memory. Journal of Neuroscience 24, 9985\u20139992 (2004).","journal-title":"Journal of Neuroscience"},{"key":"25562_CR26","doi-asserted-by":"publisher","first-page":"1415","DOI":"10.1162\/jocn.2008.20098","volume":"20","author":"A Fl\u00f6el","year":"2008","unstructured":"Fl\u00f6el, A., R\u00f6sser, N., Michka, O., Knecht, S. & Breitenstein, C. Noninvasive Brain Stimulation Improves Language Learning. Journal of Cognitive Neuroscience 20, 1415\u20131422 (2008).","journal-title":"Journal of Cognitive Neuroscience"},{"key":"25562_CR27","doi-asserted-by":"publisher","first-page":"3553","DOI":"10.1097\/00001756-200111160-00036","volume":"12","author":"A Antal","year":"2001","unstructured":"Antal, A., Nitsche, M. A. & Paulus, W. External modulation of visual perception in humans. NeuroReport 12, 3553\u20133555 (2001).","journal-title":"NeuroReport"},{"key":"25562_CR28","doi-asserted-by":"publisher","first-page":"313","DOI":"10.1111\/j.0953-816X.2004.03450.x","volume":"20","author":"A Rogalewski","year":"2004","unstructured":"Rogalewski, A., Breitenstein, C., Nitsche, M. A., Paulus, W. & Knecht, S. Transcranial direct current stimulation disrupts tactile perception. European Journal of Neuroscience 20, 313\u2013316 (2004).","journal-title":"European Journal of Neuroscience"},{"key":"25562_CR29","doi-asserted-by":"publisher","first-page":"56","DOI":"10.1097\/AJP.0b013e318157233b","volume":"24","author":"A Antal","year":"2008","unstructured":"Antal, A. et al. Transcranial Direct Current Stimulation Over Somatosensory Cortex Decreases ExperimentallyInduced Acute Pain Perception. Clinical Journal of Pain 24, 56\u201363 (2008).","journal-title":"Clinical Journal of Pain"},{"key":"25562_CR30","doi-asserted-by":"publisher","first-page":"805","DOI":"10.1016\/j.clinph.2007.12.001","volume":"119","author":"P Ragert","year":"2008","unstructured":"Ragert, P., Vandermeeren, Y., Camus, M. & Cohen, L. G. Improvement of spatial tactile acuity by transcranial direct current stimulation. Clinical Neurophysiology 119, 805\u2013811 (2008).","journal-title":"Clinical Neurophysiology"},{"key":"25562_CR31","doi-asserted-by":"publisher","first-page":"2075","DOI":"10.1016\/S1388-2457(01)00657-5","volume":"112","author":"MJ Schroeder","year":"2001","unstructured":"Schroeder, M. J. & Barr, R. E. Quantitative analysis of the electroencephalogram during cranial electrotherapy stimulation. Clinical Neurophysiology 112, 2075\u20132083 (2001).","journal-title":"Clinical Neurophysiology"},{"key":"25562_CR32","doi-asserted-by":"publisher","first-page":"610","DOI":"10.1038\/nature05278","volume":"444","author":"L Marshall","year":"2006","unstructured":"Marshall, L., Helgad\u00f3ttir, H., M\u00f6lle, M. & Born, J. Boosting slow oscillations during sleep potentiates memory. Nature 444, 610\u2013613 (2006).","journal-title":"Nature"},{"key":"25562_CR33","doi-asserted-by":"publisher","first-page":"333","DOI":"10.1016\/j.cub.2013.12.041","volume":"24","author":"RF Helfrich","year":"2014","unstructured":"Helfrich, R. F. et al. Entrainment of Brain Oscillations by Transcranial Alternating Current Stimulation. Current Biology 24, 333\u2013339 (2014).","journal-title":"Current Biology"},{"key":"25562_CR34","doi-asserted-by":"publisher","first-page":"4","DOI":"10.1016\/j.neuroimage.2016.02.012","volume":"140","author":"TO Bergmann","year":"2016","unstructured":"Bergmann, T. O., Karabanov, A., Hartwigsen, G., Thielscher, A. & Siebner, H. R. Combining non-invasive transcranial brain stimulation with neuroimaging and electrophysiology: Current approaches and future perspectives. NeuroImage 140, 4\u201319 (2016).","journal-title":"NeuroImage"},{"key":"25562_CR35","doi-asserted-by":"publisher","first-page":"702","DOI":"10.3389\/fnhum.2014.00601","volume":"8","author":"AL Mangia","year":"2014","unstructured":"Mangia, A. L., Pirini, M. & Cappello, A. Transcranial direct current stimulation and power spectral parameters: a tDCS\/EEG co-registration study. Frontiers in Human Neuroscience 8, 702 (2014).","journal-title":"Frontiers in Human Neuroscience"},{"key":"25562_CR36","doi-asserted-by":"publisher","first-page":"702","DOI":"10.1167\/iovs.03-0688","volume":"45","author":"A Antal","year":"2004","unstructured":"Antal, A., Kincses, T. Z., Nitsche, M. A., Bartfai, O. & Paulus, W. Excitability Changes Induced in the Human Primary Visual Cortex by Transcranial Direct Current Stimulation: Direct Electrophysiological Evidence. Investigative Opthalmology & Visual Science 45, 702 (2004).","journal-title":"Investigative Opthalmology & Visual Science"},{"key":"25562_CR37","doi-asserted-by":"publisher","first-page":"261","DOI":"10.1007\/s00221-006-0733-y","volume":"178","author":"N Accornero","year":"2007","unstructured":"Accornero, N., Li Voti, P., La Riccia, M. & Gregori, B. Visual evoked potentials modulation during direct current cortical polarization. Experimental Brain Research 178, 261\u2013266 (2007).","journal-title":"Experimental Brain Research"},{"key":"25562_CR38","doi-asserted-by":"publisher","first-page":"208","DOI":"10.1177\/1550059414539481","volume":"46","author":"G Strigaro","year":"2015","unstructured":"Strigaro, G., Mayer, I., Chen, J.-C., Cantello, R. & Rothwell, J. C. Transcranial Direct Current Stimulation Effects on Single and Paired Flash Visual Evoked Potentials. Clinical EEG and Neuroscience 46, 208\u2013213 (2015).","journal-title":"Clinical EEG and Neuroscience"},{"key":"25562_CR39","doi-asserted-by":"publisher","first-page":"1967","DOI":"10.1109\/TBME.2014.2311071","volume":"61","author":"A Roy","year":"2014","unstructured":"Roy, A., Baxter, B. & He, B. High-definition transcranial direct current stimulation induces both acute and persistent changes in broadband cortical synchronization: a simultaneous tDCS-EEG study. IEEE Transactions on Biomedical Engineering 61, 1967\u20131978 (2014).","journal-title":"IEEE Transactions on Biomedical Engineering"},{"key":"25562_CR40","first-page":"658","volume":"10","author":"MR van Schouwenburg","year":"2016","unstructured":"van Schouwenburg, M. R., Zanto, T. P. & Gazzaley, A. Spatial Attention and the Effects of Frontoparietal Alpha Band Stimulation. Frontiers in Human Neuroscience 10, 658 (2016).","journal-title":"Frontiers in Human Neuroscience"},{"key":"25562_CR41","doi-asserted-by":"publisher","first-page":"139","DOI":"10.1080\/21646821.2016.1202032","volume":"56","author":"C Drees","year":"2016","unstructured":"Drees, C. et al. Skin Irritation during Video-EEG Monitoring. The Neurodiagnostic Journal 56, 139\u2013150 (2016).","journal-title":"The Neurodiagnostic Journal"},{"key":"25562_CR42","doi-asserted-by":"publisher","first-page":"271","DOI":"10.1088\/0967-3334\/21\/2\/307","volume":"21","author":"A Searle","year":"2000","unstructured":"Searle, A. & Kirkup, L. A direct comparison of wet, dry and insulating bioelectric recording electrodes. Physiological Measurement 21, 271\u2013283 (2000).","journal-title":"Physiological Measurement"},{"issue":"2","key":"25562_CR43","first-page":"1","volume":"2","author":"M Teplan","year":"2002","unstructured":"Teplan, M. Fundamentals of EEG measurement. Measurement Science Review 2(2), 1\u201311 (2002).","journal-title":"Measurement Science Review"},{"key":"25562_CR44","doi-asserted-by":"publisher","first-page":"1401","DOI":"10.1212\/WNL.42.7.1401","volume":"42","author":"HH Morris","year":"1992","unstructured":"Morris, H. H., Klem, G. & Gilmore-Pollak, W. Hair loss after prolonged EEG\/video monitoring. Neurology 42, 1401\u20131402 (1992).","journal-title":"Neurology"},{"key":"25562_CR45","doi-asserted-by":"publisher","first-page":"95","DOI":"10.1002\/hbm.10010","volume":"15","author":"F Di Russo","year":"2002","unstructured":"Di Russo, F., Mart\u00ednez, A., Sereno, M. I., Pitzalis, S. & Hillyard, S. A. Cortical sources of the early components of the visual evoked potential. Human Brain Mapping 15, 95\u2013111 (2002).","journal-title":"Human Brain Mapping"},{"key":"25562_CR46","doi-asserted-by":"publisher","first-page":"647","DOI":"10.1007\/s10548-015-0435-5","volume":"28","author":"P Fiedler","year":"2015","unstructured":"Fiedler, P. et al. Novel Multipin Electrode Cap System for Dry Electroencephalography. Brain Topography 28, 647\u2013656 (2015).","journal-title":"Brain Topography"},{"key":"25562_CR47","doi-asserted-by":"crossref","unstructured":"Fiedler, P. et al. Engineering in Medicine and Biology Society (EMBC),IEEE 38th Annual International Conference of the IEEE, pp. 5705\u20135708 (2016).","DOI":"10.1109\/EMBC.2016.7592022"},{"key":"25562_CR48","doi-asserted-by":"publisher","first-page":"405","DOI":"10.1016\/j.brs.2015.01.293","volume":"8","author":"P Fiedler","year":"2015","unstructured":"Fiedler, P. et al. Novel flexible cap with integrated textile electrodes for rapid transcranial electrical stimulation. Brain Stimulation 8, 405\u2013406 (2015).","journal-title":"Brain Stimulation"},{"key":"25562_CR49","doi-asserted-by":"publisher","first-page":"2181","DOI":"10.1016\/j.clinph.2015.03.015","volume":"126","author":"A Fertonani","year":"2015","unstructured":"Fertonani, A., Ferrari, C. & Miniussi, C. What do you feel if I apply transcranial electric stimulation? Safety, sensations and secondary induced effects. Clinical Neurophysiology 126, 2181\u20132188 (2015).","journal-title":"Clinical Neurophysiology"},{"key":"25562_CR50","doi-asserted-by":"publisher","first-page":"12847","DOI":"10.3390\/s140712847","volume":"14","author":"MA Lopez-Gordo","year":"2014","unstructured":"Lopez-Gordo, M. A., Sanchez-Morillo, D. & Pelayo Valle, F. Dry EEG electrodes. Sensors 14, 12847\u201312870 (2014).","journal-title":"Sensors"},{"key":"25562_CR51","doi-asserted-by":"publisher","first-page":"184","DOI":"10.1177\/1550059412444976","volume":"43","author":"C Miniussi","year":"2012","unstructured":"Miniussi, C., Brignani, D. & Pellicciari, M. C. Combining Transcranial Electrical Stimulation With Electroencephalography: A Multimodal Approach. Clinical EEG and Neuroscience 43, 184\u2013191 (2012).","journal-title":"Clinical EEG and Neuroscience"},{"key":"25562_CR52","doi-asserted-by":"publisher","first-page":"111","DOI":"10.1007\/s10633-009-9195-4","volume":"120","author":"JV Odom","year":"2010","unstructured":"Odom, J. V. et al. ISCEV standard for clinical visual evoked potentials (2009 update). Documenta Ophthalmologica 120, 111\u2013119 (2010).","journal-title":"Documenta Ophthalmologica"},{"key":"25562_CR53","doi-asserted-by":"publisher","DOI":"10.1186\/1471-2202-12-2","volume":"12","author":"T Zaehle","year":"2011","unstructured":"Zaehle, T., Sandmann, P., Thorne, J. D., J\u00e4ncke, L. & Herrmann, C. S. Transcranial direct current stimulation of the prefrontal cortex modulates working memory performance: combined behavioural and electrophysiological evidence. BMC Neuroscience 12, 2 (2011).","journal-title":"BMC Neuroscience"},{"key":"25562_CR54","doi-asserted-by":"publisher","first-page":"65","DOI":"10.1016\/0013-4694(94)90114-7","volume":"90","author":"HA Baseler","year":"1994","unstructured":"Baseler, H. A., Sutter, E. E., Klein, S. A. & Carney, T. The topography of visual evoked response properties across the visual field. Electroencephalography and Clinical Neurophysiology 90, 65\u201381 (1994).","journal-title":"Electroencephalography and Clinical Neurophysiology"},{"key":"25562_CR55","doi-asserted-by":"publisher","first-page":"1774","DOI":"10.1016\/j.clinph.2017.06.001","volume":"128","author":"A Antal","year":"2017","unstructured":"Antal, A. et al. Low intensity transcranial electric stimulation: Safety, ethical, legal regulatory and application guidelines. Clinical Neurophysiology 128, 1774\u20131809 (2017).","journal-title":"Clinical Neurophysiology"},{"key":"25562_CR56","doi-asserted-by":"publisher","first-page":"1600","DOI":"10.1016\/j.neuroimage.2006.09.024","volume":"34","author":"V Jurcak","year":"2007","unstructured":"Jurcak, V., Tsuzuki, D. & Dan, I. 10\/20, 10\/10, and 10\/5 systems revisited: Their validity as relative head-surface-based positioning systems. NeuroImage 34, 1600\u20131611 (2007).","journal-title":"NeuroImage"}],"container-title":["Scientific Reports"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.nature.com\/articles\/s41598-018-25562-x.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.nature.com\/articles\/s41598-018-25562-x","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.nature.com\/articles\/s41598-018-25562-x.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,7,4]],"date-time":"2025-07-04T01:59:08Z","timestamp":1751594348000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.nature.com\/articles\/s41598-018-25562-x"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2018,5,8]]},"references-count":56,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2018,12]]}},"alternative-id":["25562"],"URL":"https:\/\/doi.org\/10.1038\/s41598-018-25562-x","relation":{},"ISSN":["2045-2322"],"issn-type":[{"value":"2045-2322","type":"electronic"}],"subject":[],"published":{"date-parts":[[2018,5,8]]},"assertion":[{"value":"29 December 2017","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"23 April 2018","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"8 May 2018","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"S.W and K.S are employed by neuroCare and affiliated with neuroConn GmbH, Ilmenau, Germany. F.S. was employed by neuroCare and affiliated with neuroConn GmbH during the course of the study and is now affiliated to the Department of General Practice, University Medical Center, Georg-August University, G\u00f6ttingen, Germany. P.F. was affiliated to the Institute of Biomedical Engineering and Informatics, Technische Universit\u00e4t Ilmenau, Germany during the course of the study and is now employed by eemagine Medical Imaging Solutions GmbH, Berlin, Germany. J.H. and A.H. are affiliated to the Institute of Biomedical Engineering and Informatics and\u00a0declare no competing interests.","order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing Interests"}}],"article-number":"7259"}}