{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,7]],"date-time":"2026-10-07T06:34:03Z","timestamp":1791354843833,"version":"4.3.1"},"reference-count":30,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2018,6,8]],"date-time":"2018-06-08T00:00:00Z","timestamp":1528416000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2018,6,8]],"date-time":"2018-06-08T00:00:00Z","timestamp":1528416000000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Sci Rep"],"abstract":"<jats:title>Abstract<\/jats:title><jats:p>In conventional fundus photography, trans-pupillary illumination delivers illuminating light to the interior of the eye through the peripheral area of the pupil, and only the central part of the pupil can be used for collecting imaging light. Therefore, the field of view of conventional fundus cameras is limited, and pupil dilation is required for evaluating the retinal periphery which is frequently affected by diabetic retinopathy (DR), retinopathy of prematurity (ROP), and other chorioretinal conditions. We report here a nonmydriatic wide field fundus camera employing trans-pars-planar illumination which delivers illuminating light through the pars plana, an area outside of the pupil. Trans-pars-planar illumination frees the entire pupil for imaging purpose only, and thus wide field fundus photography can be readily achieved with less pupil dilation. For proof-of-concept testing, using all off-the-shelf components a prototype instrument that can achieve 90\u00b0 fundus view coverage in single-shot fundus images, without the need of pharmacologic pupil dilation was demonstrated.<\/jats:p>","DOI":"10.1038\/s41598-018-27112-x","type":"journal-article","created":{"date-parts":[[2018,6,4]],"date-time":"2018-06-04T10:08:01Z","timestamp":1528106881000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":24,"title":["Contact-free trans-pars-planar illumination enables snapshot fundus camera for nonmydriatic wide field photography"],"prefix":"10.1038","volume":"8","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-7372-366X","authenticated-orcid":false,"given":"Benquan","family":"Wang","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Devrim","family":"Toslak","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-3095-2232","authenticated-orcid":false,"given":"Minhaj Nur","family":"Alam","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-1971-2249","authenticated-orcid":false,"given":"R. V. Paul","family":"Chan","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Xincheng","family":"Yao","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2018,6,8]]},"reference":[{"key":"27112_CR1","first-page":"889","volume":"16","author":"JA Pugh","year":"1993","unstructured":"Pugh, J. A. et al. Screening for diabetic retinopathy. The wide-angle retinal camera. Diabetes Care 16, 889\u2013895 (1993).","journal-title":"The wide-angle retinal camera. Diabetes Care"},{"key":"27112_CR2","doi-asserted-by":"publisher","first-page":"60","DOI":"10.1159\/000219687","volume":"42","author":"KV Chalam","year":"2009","unstructured":"Chalam, K. V., Brar, V. S. & Keshavamurthy, R. Evaluation of modified portable digital camera for screening of diabetic retinopathy. Ophthalmic Res 42, 60\u201362, https:\/\/doi.org\/10.1159\/000219687 (2009).","journal-title":"Ophthalmic Res"},{"key":"27112_CR3","doi-asserted-by":"publisher","first-page":"e238","DOI":"10.1542\/peds.2014-0978","volume":"135","author":"WM Fierson","year":"2015","unstructured":"Fierson, W. M. & Capone, A. Jr. American Academy of Pediatrics Section on, O. & American Academy of Ophthalmology, A. A. o. C. O. Telemedicine for evaluation of retinopathy of prematurity. Pediatrics 135, e238\u2013254, https:\/\/doi.org\/10.1542\/peds.2014-0978 (2015).","journal-title":"Pediatrics"},{"key":"27112_CR4","doi-asserted-by":"publisher","first-page":"101","DOI":"10.1016\/j.jcjo.2014.11.005","volume":"50","author":"SK Wang","year":"2015","unstructured":"Wang, S. K. et al. SUNDROP: six years of screening for retinopathy of prematurity with telemedicine. Can J Ophthalmol 50, 101\u2013106, https:\/\/doi.org\/10.1016\/j.jcjo.2014.11.005 (2015).","journal-title":"Can J Ophthalmol"},{"key":"27112_CR5","doi-asserted-by":"publisher","first-page":"221","DOI":"10.1364\/AO.48.000221","volume":"48","author":"E DeHoog","year":"2009","unstructured":"DeHoog, E. & Schwiegerling, J. Fundus camera systems: a comparative analysis. Applied optics 48, 221\u2013228 (2009).","journal-title":"Applied optics"},{"key":"27112_CR6","first-page":"630","volume":"18","author":"O Pomerantzeff","year":"1979","unstructured":"Pomerantzeff, O., Webb, R. H. & Delori, F. C. Image formation in fundus cameras. Investigative ophthalmology & visual science 18, 630\u2013637 (1979).","journal-title":"Investigative ophthalmology & visual science"},{"key":"27112_CR7","doi-asserted-by":"publisher","first-page":"7600","DOI":"10.1167\/iovs.12-10449","volume":"53","author":"K Tran","year":"2012","unstructured":"Tran, K., Mendel, T. A., Holbrook, K. L. & Yates, P. A. Construction of an inexpensive, hand-held fundus camera through modification of a consumer \u201cpoint-and-shoot\u201d camera. Investigative ophthalmology & visual science 53, 7600\u20137607, https:\/\/doi.org\/10.1167\/iovs.12-10449 (2012).","journal-title":"Investigative ophthalmology & visual science"},{"key":"27112_CR8","doi-asserted-by":"publisher","first-page":"1128","DOI":"10.1126\/science.155.3766.1128","volume":"155","author":"RA Cone","year":"1967","unstructured":"Cone, R. A. Early receptor potential: photoreversible charge displacement in rhodopsin. Science 155, 1128\u20131131 (1967).","journal-title":"Science"},{"key":"27112_CR9","doi-asserted-by":"publisher","first-page":"198","DOI":"10.1089\/tmj.2015.0068","volume":"22","author":"N Panwar","year":"2016","unstructured":"Panwar, N. et al. Fundus Photography in the 21st Century\u2013A Review of Recent Technological Advances and Their Implications for Worldwide Healthcare. Telemedicine journal and e-health: the official journal of the American Telemedicine Association 22, 198\u2013208, https:\/\/doi.org\/10.1089\/tmj.2015.0068 (2016).","journal-title":"Telemedicine journal and e-health: the official journal of the American Telemedicine Association"},{"key":"27112_CR10","unstructured":"Pomerantzeff, O. Wide-angle opthalmoscope employing transillumination. US Patent US3954329A (1976)."},{"key":"27112_CR11","unstructured":"Pomerantzeff, O. Illumination system for ophthalmoscope. US Patent US4061423A (1977)."},{"key":"27112_CR12","doi-asserted-by":"publisher","first-page":"1603","DOI":"10.1001\/archopht.121.11.1603","volume":"121","author":"CL Shields","year":"2003","unstructured":"Shields, C. L., Materin, M. & Shields, J. A. Panoramic imaging of the ocular fundus. Arch Ophthalmol 121, 1603\u20131607, https:\/\/doi.org\/10.1001\/archopht.121.11.1603 (2003).","journal-title":"Arch Ophthalmol"},{"key":"27112_CR13","doi-asserted-by":"publisher","first-page":"2688","DOI":"10.1364\/OL.41.002688","volume":"41","author":"D Toslak","year":"2016","unstructured":"Toslak, D. et al. Trans-palpebral illumination: an approach for wide-angle fundus photography without the need for pupil dilation. Optics letters 41, 2688\u20132691, https:\/\/doi.org\/10.1364\/OL.41.002688 (2016).","journal-title":"Optics letters"},{"key":"27112_CR14","doi-asserted-by":"publisher","first-page":"1741","DOI":"10.1364\/BOE.8.001741","volume":"8","author":"M Alam","year":"2017","unstructured":"Alam, M., Thapa, D., Lim, J. I., Cao, D. & Yao, X. C. Quantitative characteristics of sickle cell retinopathy in optical coherence tomography angiography. Biomedical optics express 8, 1741\u20131753, https:\/\/doi.org\/10.1364\/Boe.8.001741 (2017).","journal-title":"Biomedical optics express"},{"key":"27112_CR15","doi-asserted-by":"publisher","first-page":"e59","DOI":"10.1016\/j.ophtha.2007.10.006","volume":"114","author":"S Koreen","year":"2007","unstructured":"Koreen, S. et al. Evaluation of a computer-based system for plus disease diagnosis in retinopathy of prematurity. Ophthalmology 114, e59\u201367, https:\/\/doi.org\/10.1016\/j.ophtha.2007.10.006 (2007).","journal-title":"Ophthalmology"},{"key":"27112_CR16","doi-asserted-by":"publisher","first-page":"2708","DOI":"10.2337\/dc07-0732","volume":"30","author":"TT Nguyen","year":"2007","unstructured":"Nguyen, T. T., Wang, J. J. & Wong, T. Y. Retinal vascular changes in pre-diabetes and prehypertension: new findings and their research and clinical implications. Diabetes Care 30, 2708\u20132715, https:\/\/doi.org\/10.2337\/dc07-0732 (2007).","journal-title":"Diabetes Care"},{"key":"27112_CR17","doi-asserted-by":"publisher","first-page":"277","DOI":"10.1007\/s11892-009-0043-4","volume":"9","author":"TT Nguyen","year":"2009","unstructured":"Nguyen, T. T. & Wong, T. Y. Retinal vascular changes and diabetic retinopathy. Curr Diab Rep 9, 277\u2013283 (2009).","journal-title":"Curr Diab Rep"},{"key":"27112_CR18","doi-asserted-by":"publisher","first-page":"1427","DOI":"10.1109\/TBME.2007.900804","volume":"54","author":"H Narasimha-Iyer","year":"2007","unstructured":"Narasimha-Iyer, H., Beach, J. M., Khoobehi, B. & Roysam, B. Automatic identification of retinal arteries and veins from dual-wavelength images using structural and functional features. IEEE Trans Biomed Eng 54, 1427\u20131435, https:\/\/doi.org\/10.1109\/TBME.2007.900804 (2007).","journal-title":"IEEE Trans Biomed Eng"},{"key":"27112_CR19","doi-asserted-by":"publisher","first-page":"3550","DOI":"10.1109\/IEMBS.2008.4649972","volume":"2008","author":"L Tramontan","year":"2008","unstructured":"Tramontan, L., Grisan, E. & Ruggeri, A. An improved system for the automatic estimation of the Arteriolar-to-Venular diameter Ratio (AVR) in retinal images. Conf Proc IEEE Eng Med Biol Soc 2008, 3550\u20133553, https:\/\/doi.org\/10.1109\/IEMBS.2008.4649972 (2008).","journal-title":"Conf Proc IEEE Eng Med Biol Soc"},{"key":"27112_CR20","doi-asserted-by":"publisher","DOI":"10.1016\/j.ophtha.2017.02.012","author":"PS Silva","year":"2017","unstructured":"Silva, P. S. et al. Hemorrhage and\/or Microaneurysm Severity and Count in Ultrawide Field Images and Early Treatment Diabetic Retinopathy Study Photography. Ophthalmology. https:\/\/doi.org\/10.1016\/j.ophtha.2017.02.012 (2017).","journal-title":"Ophthalmology"},{"key":"27112_CR21","doi-asserted-by":"publisher","first-page":"50","DOI":"10.2337\/dc13-1292","volume":"37","author":"PS Silva","year":"2014","unstructured":"Silva, P. S. et al. Potential efficiency benefits of nonmydriatic ultrawide field retinal imaging in an ocular telehealth diabetic retinopathy program. Diabetes Care 37, 50\u201355, https:\/\/doi.org\/10.2337\/dc13-1292 (2014).","journal-title":"Diabetes Care"},{"key":"27112_CR22","unstructured":"Foster, C. S. & Vitale, A. T. In Diagnosis and treatment of uveitis Ch. 2, 11 (WB Saunders Philadelphia, 2002)."},{"key":"27112_CR23","doi-asserted-by":"crossref","unstructured":"Bye, L., Modi, N. & Stanford, M. In Basic sciences for ophthalmology Ch. 1, 51 (OUP Oxford, 2013).","DOI":"10.1093\/med\/9780199584994.003.0001"},{"key":"27112_CR24","doi-asserted-by":"publisher","first-page":"558","DOI":"10.1113\/jphysiol.1966.sp008056","volume":"186","author":"FW Campbell","year":"1966","unstructured":"Campbell, F. W. & Gubisch, R. W. Optical quality of the human eye. The Journal of physiology 186, 558\u2013578 (1966).","journal-title":"The Journal of physiology"},{"key":"27112_CR25","doi-asserted-by":"publisher","first-page":"2873","DOI":"10.1364\/JOSAA.14.002873","volume":"14","author":"J Liang","year":"1997","unstructured":"Liang, J. & Williams, D. R. Aberrations and retinal image quality of the normal human eye. Journal of the Optical Society of America. A, Optics, image science, and vision 14, 2873\u20132883 (1997).","journal-title":"Journal of the Optical Society of America. A, Optics, image science, and vision"},{"key":"27112_CR26","doi-asserted-by":"publisher","first-page":"237","DOI":"10.1016\/S0002-9394(99)80096-8","volume":"125","author":"TW Olsen","year":"1998","unstructured":"Olsen, T. W., Aaberg, S. Y., Geroski, D. H. & Edelhauser, H. F. Human sclera: thickness and surface area. American journal of ophthalmology 125, 237\u2013241 (1998).","journal-title":"American journal of ophthalmology"},{"key":"27112_CR27","doi-asserted-by":"publisher","first-page":"331","DOI":"10.1002\/lsm.1900110404","volume":"11","author":"A Vogel","year":"1991","unstructured":"Vogel, A., Dlugos, C., Nuffer, R. & Birngruber, R. Optical properties of human sclera, and their consequences for transscleral laser applications. Lasers Surg Med 11, 331\u2013340 (1991).","journal-title":"Lasers Surg Med"},{"key":"27112_CR28","unstructured":"In ISO 15004-2 (International Organization for Standardization, 2007)."},{"key":"27112_CR29","doi-asserted-by":"publisher","first-page":"263","DOI":"10.1109\/42.34715","volume":"8","author":"S Chaudhuri","year":"1989","unstructured":"Chaudhuri, S., Chatterjee, S., Katz, N., Nelson, M. & Goldbaum, M. Detection of blood vessels in retinal images using two-dimensional matched filters. IEEE transactions on medical imaging 8, 263\u2013269, https:\/\/doi.org\/10.1109\/42.34715 (1989).","journal-title":"IEEE transactions on medical imaging"},{"key":"27112_CR30","doi-asserted-by":"publisher","first-page":"51","DOI":"10.3341\/kjo.1998.12.2.103","volume":"12","author":"SB Lee","year":"1998","unstructured":"Lee, S. B., Uhm, K. B. & Hong, C. Retinal vessel diameter in normal and primary open-angle glaucoma. Korean J Ophthalmol 12, 51\u201359, https:\/\/doi.org\/10.3341\/kjo.1998.12.1.51 (1998).","journal-title":"Korean J Ophthalmol"}],"container-title":["Scientific Reports"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.nature.com\/articles\/s41598-018-27112-x.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.nature.com\/articles\/s41598-018-27112-x","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.nature.com\/articles\/s41598-018-27112-x.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2022,12,21]],"date-time":"2022-12-21T06:02:10Z","timestamp":1671602530000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.nature.com\/articles\/s41598-018-27112-x"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2018,6,8]]},"references-count":30,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2018,12]]}},"alternative-id":["27112"],"URL":"https:\/\/doi.org\/10.1038\/s41598-018-27112-x","relation":{},"ISSN":["2045-2322"],"issn-type":[{"value":"2045-2322","type":"electronic"}],"subject":[],"published":{"date-parts":[[2018,6,8]]},"assertion":[{"value":"13 July 2017","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"29 May 2018","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"8 June 2018","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"B.W., D.T. and X.Y. have pending patent (US 62\/518,801) relative to this work. M.N.A. and R.V.P.C. have no competing interests.","order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing Interests"}}],"article-number":"8768"}}