{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,27]],"date-time":"2026-10-27T13:21:16Z","timestamp":1793107276573,"version":"4.5.0"},"reference-count":39,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2018,6,29]],"date-time":"2018-06-29T00:00:00Z","timestamp":1530230400000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2018,6,29]],"date-time":"2018-06-29T00:00:00Z","timestamp":1530230400000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"funder":[{"DOI":"10.13039\/501100004963","name":"EC | Seventh Framework Programme","doi-asserted-by":"publisher","award":["ERC-2011-AdG- 294099"],"award-info":[{"award-number":["ERC-2011-AdG- 294099"]}],"id":[{"id":"10.13039\/501100004963","id-type":"DOI","asserted-by":"publisher"}]},{"DOI":"10.13039\/501100003339","name":"Ministry of Economy and Competitiveness | Consejo Superior de Investigaciones Cient&amp;#x00ED;ficas","doi-asserted-by":"publisher","award":["FIS2011-25637"],"award-info":[{"award-number":["FIS2011-25637"]}],"id":[{"id":"10.13039\/501100003339","id-type":"DOI","asserted-by":"publisher"}]},{"DOI":"10.13039\/501100003339","name":"Ministry of Economy and Competitiveness | Consejo Superior de Investigaciones Cient&amp;#x00ED;ficas","doi-asserted-by":"publisher","award":["FIS2014-56643-R"],"award-info":[{"award-number":["FIS2014-56643-R"]}],"id":[{"id":"10.13039\/501100003339","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Sci Rep"],"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:p>In a cataract surgery, the opacified crystalline lens is replaced by an artificial intraocular lens (IOL). To optimize the visual quality after surgery, the intraocular lens to be implanted must be selected preoperatively for every individual patient. Different generations of formulas have been proposed for selecting the intraocular lens dioptric power as a function of its estimated postoperative position. However, very few formulas include crystalline lens information, in most cases only one-dimensional. The present study proposes a new formula to preoperatively estimate the postoperative IOL position (ELP) based on information of the 3-dimensional full shape of the crystalline lens, obtained from quantitative eye anterior segment optical coherence tomography imaging. Real patients were measured before and after cataract surgery (IOL implantation). The IOL position and the postoperative refraction estimation errors were calculated by subtracting the preoperative estimations from the actual values measured after surgery. The proposed ELP formula produced lower estimation errors for both parameters -ELP and refraction- than the predictions obtained with standard state-of-the-art methods, and opens new avenues to the development of new generation IOL power calculation formulas that improve refractive and visual outcomes.<\/jats:p>","DOI":"10.1038\/s41598-018-28272-6","type":"journal-article","created":{"date-parts":[[2018,6,25]],"date-time":"2018-06-25T06:09:39Z","timestamp":1529906979000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":61,"title":["Estimation of intraocular lens position from full crystalline lens geometry: towards a new generation of intraocular lens power calculation formulas"],"prefix":"10.1038","volume":"8","author":[{"ORCID":"https:\/\/orcid.org\/0000-0001-7097-8846","authenticated-orcid":false,"given":"Eduardo","family":"Martinez-Enriquez","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Pablo","family":"P\u00e9rez-Merino","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Sonia","family":"Dur\u00e1n-Poveda","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ignacio","family":"Jim\u00e9nez-Alfaro","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Susana","family":"Marcos","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2018,6,29]]},"reference":[{"key":"28272_CR1","doi-asserted-by":"publisher","first-page":"635","DOI":"10.1136\/bjo.85.6.635","volume":"85","author":"A Foster","year":"2001","unstructured":"Foster, A. Cataract and \u201cVision 2020\u2014the right to sight\u201d initiative. British Journal of Ophthalmology 85, 635\u2013637 (2001).","journal-title":"British Journal of Ophthalmology"},{"key":"28272_CR2","doi-asserted-by":"publisher","first-page":"472","DOI":"10.1111\/j.1755-3768.2007.00879.x","volume":"85","author":"T Olsen","year":"2007","unstructured":"Olsen, T. Calculation of intraocular lens power: a review. Acta Ophthalmol. Scand. 85, 472\u2013485 (2007).","journal-title":"Acta Ophthalmol. Scand."},{"key":"28272_CR3","doi-asserted-by":"publisher","first-page":"337","DOI":"10.1016\/S0146-2776(81)80031-6","volume":"7","author":"D Sanders","year":"1981","unstructured":"Sanders, D. et al. Comparison of the accuracy of the Binkhorst, Colenbrander, and SRK implant power prediction formulas. J. Am. Intraocul. Implant. Soc. 7, 337\u2013340 (1981).","journal-title":"J. Am. Intraocul. Implant. Soc."},{"key":"28272_CR4","doi-asserted-by":"publisher","first-page":"136","DOI":"10.1016\/S0886-3350(88)80087-7","volume":"14","author":"DR Sanders","year":"1988","unstructured":"Sanders, D. R., Retzlaff, J. & Kraff, M. C. Comparison of the SRK II formula and other second generation formulas. J Cataract Refract. Surg. 14, 136\u2013141 (1988).","journal-title":"J Cataract Refract. Surg."},{"key":"28272_CR5","first-page":"17","volume":"6","author":"RD Binkhorst","year":"1975","unstructured":"Binkhorst, R. D. The optical design of intraocular lens implants. Ophthalmic Surg. 6, 17\u201331 (1975).","journal-title":"Ophthalmic Surg."},{"key":"28272_CR6","unstructured":"Binkhorst, R. D. Biometric A-scan ultrasonography and intraocular lens power calculation. Selected proceedings of the fifth biennial cataract surgical congress, St. Louis, Mosby 175\u2013182 (1978)."},{"key":"28272_CR7","doi-asserted-by":"publisher","first-page":"735","DOI":"10.1136\/bjo.57.10.735","volume":"57","author":"MC Colenbrander","year":"1973","unstructured":"Colenbrander, M. C. Calculation of the power of an iris clip lens for distant vision. Br. J. Ophthalmol. 57, 735\u2013740 (1973).","journal-title":"Br. J. Ophthalmol."},{"key":"28272_CR8","doi-asserted-by":"publisher","first-page":"17","DOI":"10.1016\/S0886-3350(88)80059-2","volume":"14","author":"JT Holladay","year":"1988","unstructured":"Holladay, J. T. et al. A three-part system for refining intraocular lens power calculations. J. Cataract Refract. Surg. 14, 17\u201324 (1988).","journal-title":"J. Cataract Refract. Surg."},{"key":"28272_CR9","doi-asserted-by":"publisher","first-page":"333","DOI":"10.1016\/S0886-3350(13)80705-5","volume":"16","author":"JA Retzlaff","year":"1990","unstructured":"Retzlaff, J. A., Sanders, D. R. & Kraff, M. C. Development of the SRK\/T intraocular lens implant power calculation formula. J. Cataract Refract. Surg. 16, 333\u2013340 (1990).","journal-title":"J. Cataract Refract. Surg."},{"key":"28272_CR10","unstructured":"Haigis, W. In Intraocular Lens Power Calculations (ed Shammas H.) 41\u201357 (Slack, 2004)."},{"key":"28272_CR11","first-page":"20","volume":"1","author":"KJ Hoffer","year":"1984","unstructured":"Hoffer, K. J. The effect of axial length on posterior chamber lens and posterior capsule position. Current concepts Ophthalmic Surg. 1, 20\u201322 (1984).","journal-title":"Current concepts Ophthalmic Surg."},{"key":"28272_CR12","doi-asserted-by":"publisher","first-page":"700","DOI":"10.1016\/S0886-3350(13)80338-0","volume":"19","author":"KJ Hoffer","year":"1993","unstructured":"Hoffer, K. J. The Hoffer Q formula: a comparison of theoretic and regression formulas. J Cataract Refract. Surg. 19, 700\u2013712 (1993).","journal-title":"J Cataract Refract. Surg."},{"key":"28272_CR13","doi-asserted-by":"publisher","first-page":"419","DOI":"10.1016\/j.jcrs.2005.12.139","volume":"32","author":"T Olsen","year":"2006","unstructured":"Olsen, T. Prediction of the effective postoperative (intraocular lens) anterior chamber depth. J. Cataract Refract. Surg. 32, 419\u2013424 (2006).","journal-title":"J. Cataract Refract. Surg."},{"key":"28272_CR14","doi-asserted-by":"publisher","first-page":"368","DOI":"10.1016\/j.jcrs.2007.10.031","volume":"34","author":"S Norrby","year":"2008","unstructured":"Norrby, S. Sources of error in intraocular lens power calculation. J. Cataract Refract. Surg. 34, 368\u2013376 (2008).","journal-title":"J. Cataract Refract. Surg."},{"key":"28272_CR15","doi-asserted-by":"publisher","DOI":"10.1038\/s41598-017-13800-7","volume":"7","author":"W Wang","year":"2017","unstructured":"Wang, W. et al. Precision of a new ocular biometer in eyes with cataract using swept source optical coherence tomography combined with Placido-disk corneal topography. Sci. Rep. 7, 13736 (2017).","journal-title":"Sci. Rep."},{"key":"28272_CR16","doi-asserted-by":"publisher","first-page":"587","DOI":"10.1016\/S0886-3350(13)80774-2","volume":"16","author":"T Olsen","year":"1990","unstructured":"Olsen, T., Olesen, H., Thim, K. & Corydon, L. Prediction of postoperative intraocular lens chamber depth. J. Cataract Refract. Surg. 16, 587\u2013590 (1990).","journal-title":"J. Cataract Refract. Surg."},{"key":"28272_CR17","doi-asserted-by":"publisher","first-page":"764","DOI":"10.1016\/j.jcrs.2013.10.037","volume":"40","author":"T Olsen","year":"2014","unstructured":"Olsen, T. & Hoffmann, P. C constant: new concept for ray tracing-assisted intraocular lens power calculation. J. Cataract. Refract. Surg. 40, 764\u2013773 (2014).","journal-title":"J. Cataract. Refract. Surg."},{"key":"28272_CR18","doi-asserted-by":"crossref","first-page":"1356","DOI":"10.1167\/iovs.15-16541","volume":"56","author":"KY Hwang","year":"2015","unstructured":"Hwang, K. Y., Yoo, Y. S., Joo, C. K. & Yoon, G. New parameter for predicting the postoperative IOL position: preoperative lens equator depth measured by three-dimentional anterior segment optical coherence tomography. Investigative Ophthalmology & Visual Science 56, 1356\u20131356 (2015).","journal-title":"Investigative Ophthalmology & Visual Science"},{"key":"28272_CR19","doi-asserted-by":"publisher","first-page":"2782","DOI":"10.1364\/OE.18.002782","volume":"18","author":"S Ortiz","year":"2010","unstructured":"Ortiz, S. et al. Optical distortion correction in optical coherence tomography for quantitative ocular anterior segment by three-dimensional imaging. Opt. Express 18, 2782\u20132796 (2010).","journal-title":"Opt. Express"},{"key":"28272_CR20","doi-asserted-by":"publisher","first-page":"6708","DOI":"10.1364\/AO.48.006708","volume":"48","author":"S Ortiz","year":"2009","unstructured":"Ortiz, S., Siedlecki, D., Remon, L. & Marcos, S. Optical coherence tomography for quantitative surface topography. Appl. Opt. 48, 6708\u20136715 (2009).","journal-title":"Appl. Opt."},{"key":"28272_CR21","doi-asserted-by":"publisher","first-page":"1074","DOI":"10.1364\/BOE.7.001074","volume":"7","author":"M Sun","year":"2016","unstructured":"Sun, M., P\u00e9rez-Merino, P., Martinez-Enriquez, E., Velasco-Ocana, M. & Marcos, S. Full 3-D OCT-based pseudophakic custom computer eye model. Biomed. Opt. Express 7, 1074\u20131088 (2016).","journal-title":"Biomed. Opt. Express"},{"key":"28272_CR22","doi-asserted-by":"publisher","first-page":"2471","DOI":"10.1364\/BOE.3.002471","volume":"3","author":"S Ortiz","year":"2012","unstructured":"Ortiz, S., Perez-Merino, P., Gambra, E., de Castro, A. & Marcos, S. In vivo human crystalline lens topography. Biomed. Opt. Express 3, 2471\u20132488 (2012).","journal-title":"Biomed. Opt. Express"},{"key":"28272_CR23","doi-asserted-by":"crossref","unstructured":"Martinez-Enriquez, E. et al. Optical coherence tomography based estimates of crystalline lens volume, equatorial diameter, and plane position. Invest. Ophthalmol. Vis. Sci. 57, OCT600\u2013610 (2016).","DOI":"10.1167\/iovs.15-18933"},{"key":"28272_CR24","doi-asserted-by":"publisher","first-page":"247","DOI":"10.1159\/000456720","volume":"57","author":"RI Barraquer","year":"2017","unstructured":"Barraquer, R. I. et al. Validation of the Nuclear Cataract Grading System BCN 10. Ophthalmic Res. 57, 247\u2013251 (2017).","journal-title":"Ophthalmic Res."},{"key":"28272_CR25","doi-asserted-by":"publisher","first-page":"4842","DOI":"10.1364\/OE.17.004842","volume":"17","author":"I Grulkowski","year":"2009","unstructured":"Grulkowski, I. et al. Anterior segment imaging with Spectral OCT system using a high-speed CMOS camera. Opt. Express 17, 4842\u20134858 (2009).","journal-title":"Opt. Express"},{"key":"28272_CR26","doi-asserted-by":"publisher","first-page":"5039","DOI":"10.1364\/BOE.6.005039","volume":"6","author":"P P\u00e9rez-Merino","year":"2015","unstructured":"P\u00e9rez-Merino, P., Velasco-Ocana, M., Martinez-Enriquez, E. & Marcos, S. OCT-based crystalline lens topography in accommodating eyes. Biomed. Opt. Express 6, 5039\u20135054 (2015).","journal-title":"Biomed. Opt. Express"},{"key":"28272_CR27","doi-asserted-by":"publisher","first-page":"918","DOI":"10.1364\/BOE.8.000918","volume":"8","author":"E Martinez-Enriquez","year":"2017","unstructured":"Martinez-Enriquez, E., Perez-Merino, P., Velasco-Ocana, M. & Marcos, S. OCT-based full crystalline lens shape change during accommodation in vivo. Biomed. Opt. Express 8, 918\u2013933 (2017).","journal-title":"Biomed. Opt. Express"},{"key":"28272_CR28","first-page":"1304","volume":"38","author":"W Drexler","year":"1997","unstructured":"Drexler, W. et al. Submicrometer precision biometry of the anterior segment of the human eye. Invest. Ophthalmol. Vis. Sci. 38, 1304\u20131313 (1997).","journal-title":"Invest. Ophthalmol. Vis. Sci."},{"key":"28272_CR29","doi-asserted-by":"publisher","first-page":"2732","DOI":"10.1016\/j.visres.2008.09.010","volume":"48","author":"SR Uhlhorn","year":"2008","unstructured":"Uhlhorn, S. R., Borja, D., Manns, F. & Parel, J. M. Refractive index measurement of the isolated crystalline lens using optical coherence tomography. Vision Res. 48, 2732\u20132738 (2008).","journal-title":"Vision Res."},{"key":"28272_CR30","doi-asserted-by":"publisher","first-page":"2173","DOI":"10.1364\/BOE.8.002173","volume":"8","author":"P P\u00e9rez-Merino","year":"2017","unstructured":"P\u00e9rez-Merino, P. et al. Three-dimensional OCT based guinea pig eye model: relating morphology and optics. Biomed. Opt. Express 8, 2173\u20132184 (2017).","journal-title":"Biomed. Opt. Express"},{"key":"28272_CR31","doi-asserted-by":"publisher","first-page":"897","DOI":"10.1167\/iovs.17-23596","volume":"59","author":"A de Castro","year":"2018","unstructured":"de Castro, A. et al. Three-dimensional cataract crystalline lens imaging with swept-source optical coherence tomography. Invest. Ophthalmol. Vis. Sci. 59, 897\u2013903 (2018).","journal-title":"Invest. Ophthalmol. Vis. Sci."},{"key":"28272_CR32","doi-asserted-by":"publisher","first-page":"1201","DOI":"10.1136\/bjophthalmol-2015-307779","volume":"100","author":"A Akman","year":"2016","unstructured":"Akman, A., Asena, L. & Gungor, S. G. Evaluation and comparison of the new swept source OCT-based IOLMaster 700 with the IOLMaster 500. Br. J. Ophthalmol. 100, 1201\u20131205 (2016).","journal-title":"Br. J. Ophthalmol."},{"key":"28272_CR33","doi-asserted-by":"publisher","first-page":"245","DOI":"10.1016\/S0004-3702(97)00063-5","volume":"97","author":"AL Blum","year":"1997","unstructured":"Blum, A. L. & Langley, P. Selection of relevant features and examples in machine learning. Artificial Intelligence 97, 245\u2013271 (1997).","journal-title":"Artificial Intelligence"},{"key":"28272_CR34","doi-asserted-by":"publisher","first-page":"232","DOI":"10.1016\/j.ajo.2016.08.016","volume":"170","author":"K Hayashi","year":"2016","unstructured":"Hayashi, K., Ogawa, S., Yoshida, M. & Yoshimura, K. Influence of patient age on intraocular lens power prediction error. Am. J. Ophthalmol. 170, 232\u2013237 (2016).","journal-title":"Am. J. Ophthalmol."},{"key":"28272_CR35","doi-asserted-by":"publisher","first-page":"577","DOI":"10.1016\/j.ajo.2014.11.036","volume":"159","author":"G Carifi","year":"2015","unstructured":"Carifi, G., Aiello, F., Zygoura, V., Kopsachilis, N. & Maurino, V. Accuracy of the refractive prediction determined by multiple currently available intraocular lens power calculation formulas in small eyes. Am. J. Ophthalmol. 159, 577\u2013583 (2015).","journal-title":"Am. J. Ophthalmol."},{"key":"28272_CR36","doi-asserted-by":"publisher","first-page":"693","DOI":"10.1016\/S0161-6420(99)90153-7","volume":"106","author":"B Seitz","year":"1999","unstructured":"Seitz, B., Langenbucher, A., Nguyen, N. X., Kus, M. M. & Kuchle, M. Underestimation of intraocular lens power for cataract surgery after myopic photorefractive keratectomy. Ophthalmology 106, 693\u2013702 (1999).","journal-title":"Ophthalmology"},{"key":"28272_CR37","doi-asserted-by":"publisher","first-page":"940","DOI":"10.1016\/j.ophtha.2010.08.048","volume":"118","author":"M McCarthy","year":"2011","unstructured":"McCarthy, M., Gavanski, G. M., Paton, K. E. & Holland, S. P. Intraocular lens power calculations after myopic laser refractive surgery: a comparison of methods in 173 eyes. Ophthalmology 118, 940\u2013944 (2011).","journal-title":"Ophthalmology"},{"key":"28272_CR38","doi-asserted-by":"publisher","first-page":"45","DOI":"10.1016\/S0886-3350(03)00459-0","volume":"30","author":"MG Wirtitsch","year":"2004","unstructured":"Wirtitsch, M. G. et al. Effect of haptic design on change in axial lens position after cataract surgery. J. Cataract Refract. Surg. 30, 45\u201351 (2004).","journal-title":"J. Cataract Refract. Surg."},{"key":"28272_CR39","doi-asserted-by":"publisher","first-page":"35","DOI":"10.1016\/j.jcrs.2015.08.015","volume":"42","author":"S Klijn","year":"2016","unstructured":"Klijn, S., Sicam, V. A. & Reus, N. J. Long-term changes in intraocular lens position and corneal curvature after cataract surgery and their effect on refraction. J. Cataract Refract. Surg. 42, 35\u201343 (2016).","journal-title":"J. Cataract Refract. Surg."}],"container-title":["Scientific Reports"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.nature.com\/articles\/s41598-018-28272-6.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.nature.com\/articles\/s41598-018-28272-6","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.nature.com\/articles\/s41598-018-28272-6.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2024,7,7]],"date-time":"2024-07-07T14:06:30Z","timestamp":1720361190000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.nature.com\/articles\/s41598-018-28272-6"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2018,6,29]]},"references-count":39,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2018,12]]}},"alternative-id":["28272"],"URL":"https:\/\/doi.org\/10.1038\/s41598-018-28272-6","relation":{},"ISSN":["2045-2322"],"issn-type":[{"value":"2045-2322","type":"electronic"}],"subject":[],"published":{"date-parts":[[2018,6,29]]},"assertion":[{"value":"6 March 2018","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"20 June 2018","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"29 June 2018","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"The authors declare no competing interests.","order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing Interests"}}],"article-number":"9829"}}