{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,17]],"date-time":"2026-08-17T21:49:19Z","timestamp":1787003359336,"version":"build-2736575974"},"reference-count":16,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2018,7,6]],"date-time":"2018-07-06T00:00:00Z","timestamp":1530835200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2018,7,6]],"date-time":"2018-07-06T00:00:00Z","timestamp":1530835200000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Sci Rep"],"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:p>\n                    Accurate alignment of an intraocular lens (IOL) is indispensable for achieving accurate postoperative refractive outcomes. Thus, we evaluated decentration and tilt of single- and three-piece IOLs, as well as anterior chamber depth (ACD), at 3\u2009hours, 24\u2009hours, 2 weeks, and 4 weeks after cataract surgery, using swept-source anterior segment optical coherence tomography. There was no significant difference in postoperative visual acuity between eyes with single- or three-piece IOLs. Absolute values of IOL decentration at 24\u2009hours and 2 weeks after surgery were significantly larger (\n                    <jats:italic>P<\/jats:italic>\n                    \u2009=\u20090.008 and 0.046, respectively) in eyes with the single-piece IOL than in those with the three-piece IOL. Both single- and three-piece IOLs tended to tilt toward the inferotemporal direction; however, there was no significant difference in the absolute values of IOL tilt at any postoperative time point. ACD at 24\u2009hours after surgery was significantly deeper (\n                    <jats:italic>P<\/jats:italic>\n                    \u2009=\u20090.009) in eyes with the three-piece IOL, compared with eyes with the single-piece IOL. Therefore, although both single- and three-piece IOL locations varied transiently after surgery, IOL locations were similar between both IOLs at 4 weeks after surgery and were not associated with any statistical difference in visual function.\n                  <\/jats:p>","DOI":"10.1038\/s41598-018-28609-1","type":"journal-article","created":{"date-parts":[[2018,7,2]],"date-time":"2018-07-02T05:10:18Z","timestamp":1530508218000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":31,"title":["Short-term Dynamics after Single- and Three-piece Acrylic Intraocular Lens Implantation: A Swept-source Anterior Segment Optical Coherence Tomography Study"],"prefix":"10.1038","volume":"8","author":[{"given":"Tatsuhiko","family":"Sato","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Shunsuke","family":"Shibata","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Motoaki","family":"Yoshida","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ken","family":"Hayashi","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2018,7,6]]},"reference":[{"key":"28609_CR1","doi-asserted-by":"publisher","first-page":"337","DOI":"10.1016\/j.jcrs.2004.06.042","volume":"31","author":"K Hayashi","year":"2005","unstructured":"Hayashi, K. & Hayashi, H. Comparison of the stability of 1-piece and 3-piece acrylic intraocular lenses in the lens capsule. J Cataract Refract Surg. 31, 337\u2013342 (2005).","journal-title":"J Cataract Refract Surg."},{"key":"28609_CR2","doi-asserted-by":"publisher","first-page":"406","DOI":"10.1016\/j.ajo.2010.09.013","volume":"151","author":"DA Kumar","year":"2011","unstructured":"Kumar, D. A. et al. Evaluation of intraocular lens tilt with anterior segment optical coherence tomography. Am J Ophthalmol. 151, 406\u2013412.e2 (2011).","journal-title":"Am J Ophthalmol."},{"key":"28609_CR3","doi-asserted-by":"publisher","first-page":"1517","DOI":"10.1016\/j.jcrs.2010.02.028","volume":"36","author":"JL Alio","year":"2010","unstructured":"Alio, J. L., Pinero, D. P., Sala, E. & Amparo, F. Intraocular stability of an angle-supported phakic intraocular lens with changes in pupil diameter. J Cataract Refract Surg. 36, 1517\u20131522 (2010).","journal-title":"J Cataract Refract Surg."},{"key":"28609_CR4","doi-asserted-by":"publisher","first-page":"e0142556","DOI":"10.1371\/journal.pone.0142556","volume":"10","author":"X Ding","year":"2015","unstructured":"Ding, X. et al. The repeatability assessment of three-dimensional capsule-intraocular lens complex measurements by means of high-speed swept-source optical coherence tomography. PLoS One. 10, e0142556 (2015).","journal-title":"PLoS One."},{"key":"28609_CR5","doi-asserted-by":"publisher","first-page":"e0184066","DOI":"10.1371\/journal.pone.0184066","volume":"12","author":"S Kimura","year":"2017","unstructured":"Kimura, S. et al. Assessment of tilt and decentration of crystalline lens and intraocular lens relative to the corneal topographic axis using anterior segment optical coherence tomography. PLoS One. 12, e0184066 (2017).","journal-title":"PLoS One."},{"key":"28609_CR6","doi-asserted-by":"publisher","first-page":"159","DOI":"10.2307\/2529310","volume":"33","author":"JR Landis","year":"1977","unstructured":"Landis, J. R. & Koch, G. G. The measurement of observer agreement for categorical data. Biometrics. 33, 159\u2013174 (1977).","journal-title":"Biometrics."},{"key":"28609_CR7","doi-asserted-by":"publisher","first-page":"57","DOI":"10.1016\/S0886-3350(98)80075-8","volume":"24","author":"JT Holladay","year":"1998","unstructured":"Holladay, J. T., Dudeja, D. R. & Koch, D. D. Evaluating and reporting astigmatism for individual and aggregate data. J Cataract Refract Surg. 24, 57\u201365 (1998).","journal-title":"J Cataract Refract Surg."},{"key":"28609_CR8","doi-asserted-by":"publisher","first-page":"89","DOI":"10.1001\/archopht.1992.01080130091032","volume":"110","author":"EI Assia","year":"1992","unstructured":"Assia, E. I. & Apple, D. J. Side-view analysis of the lens. I. The crystalline lens and the evacuated bag. Arch Ophthalmol. 110, 89\u201393 (1992).","journal-title":"Arch Ophthalmol."},{"key":"28609_CR9","doi-asserted-by":"publisher","first-page":"547","DOI":"10.1016\/S0886-3350(98)80300-3","volume":"24","author":"A Vasavada","year":"1998","unstructured":"Vasavada, A. & Singh, R. Relationship between lens and capsular bag size. J Cataract Refract Surg. 24, 547\u2013551 (1998).","journal-title":"J Cataract Refract Surg."},{"key":"28609_CR10","doi-asserted-by":"publisher","first-page":"549","DOI":"10.1136\/bjo.82.5.549","volume":"82","author":"T Oshika","year":"1998","unstructured":"Oshika, T., Nagata, T. & Ishii, Y. Adhesion of lens capsule to intraocular lenses of polymethylmethacrylate, silicone, and acrylic foldable materials: an experimental study. Br J Ophthalmol. 82, 549\u2013553 (1998).","journal-title":"Br J Ophthalmol."},{"key":"28609_CR11","doi-asserted-by":"publisher","first-page":"1579","DOI":"10.1001\/archopht.116.12.1579","volume":"116","author":"H Hayashi","year":"1998","unstructured":"Hayashi, H., Hayashi, K., Nakao, F. & Hayashi, F. Quantitative comparison of posterior capsule opacification after polymethylmethacrylate, silicone, and soft acrylic intraocular lens implantation. Arch Ophthalmol. 116, 1579\u20131582 (1998).","journal-title":"Arch Ophthalmol."},{"key":"28609_CR12","doi-asserted-by":"publisher","first-page":"2397","DOI":"10.1016\/j.jcrs.2004.03.041","volume":"30","author":"SS Lane","year":"2004","unstructured":"Lane, S. S. et al. Comparison of the biomechanical behavior of foldable intraocular lenses. J Cataract Refract Surg. 30, 2397\u20132402 (2004).","journal-title":"J Cataract Refract Surg."},{"key":"28609_CR13","doi-asserted-by":"publisher","first-page":"1429","DOI":"10.1136\/bjo.82.12.1429","volume":"82","author":"H Hayashi","year":"1998","unstructured":"Hayashi, H., Hayashi, K., Nakao, F. & Hayashi, F. Anterior capsule contraction and intraocular lens dislocation in eyes with pseudoexfoliation syndrome. Br J Ophthalmol. 82, 1429\u20131432 (1998).","journal-title":"Br J Ophthalmol."},{"key":"28609_CR14","doi-asserted-by":"publisher","first-page":"1515","DOI":"10.1016\/S0886-3350(99)00242-4","volume":"25","author":"K Hayashi","year":"1999","unstructured":"Hayashi, K., Hayashi, H., Nakao, F. & Hayashi, F. Intraocular lens tilt and decentration after implantation in eyes with glaucoma. J Cataract Refract Surg. 25, 1515\u20131520 (1999).","journal-title":"J Cataract Refract Surg."},{"key":"28609_CR15","doi-asserted-by":"publisher","first-page":"97","DOI":"10.1016\/j.jcrs.2010.07.027","volume":"37","author":"K Hayashi","year":"2011","unstructured":"Hayashi, K., Yoshida, M., Hirata, A. & Hayashi, H. Anterior capsule relaxing incisions with neodymium: YAG laser for patients at high-risk for anterior capsule contraction. J Cataract Refract Surg. 37, 97\u2013103 (2011).","journal-title":"J Cataract Refract Surg."},{"key":"28609_CR16","doi-asserted-by":"publisher","first-page":"420","DOI":"10.1037\/0033-2909.86.2.420","volume":"86","author":"PE Shrout","year":"1979","unstructured":"Shrout, P. E. & Fleiss, J. L. Intraclass correlations: uses in assessing rater reliability. Psychol Bull. 86, 420\u2013428 (1979).","journal-title":"Psychol Bull."}],"container-title":["Scientific Reports"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.nature.com\/articles\/s41598-018-28609-1.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.nature.com\/articles\/s41598-018-28609-1","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.nature.com\/articles\/s41598-018-28609-1.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2022,12,21]],"date-time":"2022-12-21T02:15:45Z","timestamp":1671588945000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.nature.com\/articles\/s41598-018-28609-1"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2018,7,6]]},"references-count":16,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2018,12]]}},"alternative-id":["28609"],"URL":"https:\/\/doi.org\/10.1038\/s41598-018-28609-1","relation":{},"ISSN":["2045-2322"],"issn-type":[{"value":"2045-2322","type":"electronic"}],"subject":[],"published":{"date-parts":[[2018,7,6]]},"assertion":[{"value":"26 January 2018","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"26 June 2018","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"6 July 2018","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"The authors declare no competing interests.","order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing Interests"}}],"article-number":"10230"}}