{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,24]],"date-time":"2026-09-24T02:42:53Z","timestamp":1790217773878,"version":"4.1.0"},"reference-count":25,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2018,7,27]],"date-time":"2018-07-27T00:00:00Z","timestamp":1532649600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2018,7,27]],"date-time":"2018-07-27T00:00:00Z","timestamp":1532649600000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Sci Rep"],"abstract":"<jats:title>Abstract<\/jats:title><jats:p>Three-dimensional (3D) printing has become broadly available and can be utilized to customize clamping mechanisms in biomechanical experiments. This report will describe our experience using 3D printed clamps to mount soft tissues from different anatomical regions. The feasibility and potential limitations of the technology will be discussed. Tissues were sourced in a fresh condition, including human skin, ligaments and tendons. Standardized clamps and fixtures were 3D printed and used to mount specimens. In<jats:italic>quasi-static<\/jats:italic>tensile tests combined with digital image correlation and<jats:italic>fatigue<\/jats:italic>trials we characterized the applicability of the clamping technique. Scanning electron microscopy was utilized to evaluate the specimens to assess the integrity of the extracellular matrix following the mechanical tests. 3D printed clamps showed no signs of clamping-related failure during the<jats:italic>quasi-static<\/jats:italic>tests, and intact extracellular matrix was found in the clamping area, at the transition clamping area and the central area from where the strain data was obtained. In the<jats:italic>fatigue<\/jats:italic>tests, material slippage was low, allowing for cyclic tests beyond 10<jats:sup>5<\/jats:sup>cycles. Comparison to other clamping techniques yields that 3D printed clamps ease and expedite specimen handling, are highly adaptable to specimen geometries and ideal for high-standardization and high-throughput experiments in soft tissue biomechanics.<\/jats:p>","DOI":"10.1038\/s41598-018-29583-4","type":"journal-article","created":{"date-parts":[[2018,7,23]],"date-time":"2018-07-23T10:08:45Z","timestamp":1532340525000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":59,"title":["Utilization of 3D printing technology to facilitate and standardize soft tissue testing"],"prefix":"10.1038","volume":"8","author":[{"given":"Mario","family":"Scholze","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-5685-0635","authenticated-orcid":false,"given":"Aqeeda","family":"Singh","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Pamela F.","family":"Lozano","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Benjamin","family":"Ondruschka","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Maziar","family":"Ramezani","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Michael","family":"Werner","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Niels","family":"Hammer","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2018,7,27]]},"reference":[{"key":"29583_CR1","doi-asserted-by":"publisher","first-page":"829","DOI":"10.1016\/S0021-9290(97)00033-X","volume":"30","author":"H Schechtman","year":"1997","unstructured":"Schechtman, H. & Bader, D. L. In vitro fatigue of human tendons. J Biomech 30, 829\u2013835 (1997).","journal-title":"J Biomech"},{"key":"29583_CR2","doi-asserted-by":"publisher","first-page":"516","DOI":"10.1016\/j.medengphy.2011.11.019","volume":"34","author":"D Shi","year":"2012","unstructured":"Shi, D., Wang, D., Wang, C. & Liu, A. A novel, inexpensive and easy to use tendon clamp for in vitro biomechanical testing. Med Eng Phys 34, 516\u2013520, https:\/\/doi.org\/10.1016\/j.medengphy.2011.11.019 (2012).","journal-title":"Med Eng Phys"},{"key":"29583_CR3","first-page":"13","volume":"14","author":"JZ Wu","year":"2004","unstructured":"Wu, J. Z., Brumfield, A., Miller, G. R., Metheny, R. & Cutlip, R. G. Comparison of mechanical properties of rat tibialis anterior tendon evaluated using two different approaches. Bio-medical materials and engineering 14, 13\u201322 (2004).","journal-title":"Bio-medical materials and engineering"},{"key":"29583_CR4","doi-asserted-by":"publisher","first-page":"281","DOI":"10.1007\/BF01851700","volume":"162","author":"K Wilhelm","year":"1973","unstructured":"Wilhelm, K. Das Verhalten der menschlichen Achillesschne im Experiment bei statischer und dynamischer Belastung. Research in Experimental Medicine 162, 281\u2013297 (1973).","journal-title":"Research in Experimental Medicine"},{"key":"29583_CR5","doi-asserted-by":"publisher","first-page":"209","DOI":"10.1016\/j.jmbbm.2012.09.001","volume":"17","author":"M Takaza","year":"2013","unstructured":"Takaza, M., Moerman, K. M., Gindre, J., Lyons, G. & Simms, C. K. The anisotropic mechanical behaviour of passive skeletal muscle tissue subjected to large tensile strain. J Mech Behav Biomed Mater 17, 209\u2013220, https:\/\/doi.org\/10.1016\/j.jmbbm.2012.09.001 (2013).","journal-title":"J Mech Behav Biomed Mater"},{"key":"29583_CR6","doi-asserted-by":"publisher","first-page":"349","DOI":"10.1243\/095441105X34239","volume":"219","author":"BH Ng","year":"2005","unstructured":"Ng, B. H., Chou, S. M. & Krishna, V. The influence of gripping techniques on the tensile properties of tendons. Proc Inst Mech Eng H 219, 349\u2013354, https:\/\/doi.org\/10.1243\/095441105X34239 (2005).","journal-title":"Proc Inst Mech Eng H"},{"key":"29583_CR7","doi-asserted-by":"publisher","first-page":"387","DOI":"10.1243\/095441105X63309","volume":"219","author":"BH Ng","year":"2005","unstructured":"Ng, B. H., Chou, S. M., Lim, B. H. & Chong, A. The changes in the tensile properties of tendons after freeze storage in saline solution. Proc Inst Mech Eng H 219, 387\u2013392, https:\/\/doi.org\/10.1243\/095441105X63309 (2005).","journal-title":"Proc Inst Mech Eng H"},{"key":"29583_CR8","doi-asserted-by":"publisher","first-page":"1182","DOI":"10.1016\/j.medengphy.2009.06.008","volume":"31","author":"MO Kiss","year":"2009","unstructured":"Kiss, M. O. et al. A low-cost thermoelectrically cooled tissue clamp for in vitro cyclic loading and load-to-failure testing of muscles and tendons. Med Eng Phys 31, 1182\u20131186, https:\/\/doi.org\/10.1016\/j.medengphy.2009.06.008 (2009).","journal-title":"Med Eng Phys"},{"key":"29583_CR9","doi-asserted-by":"publisher","first-page":"324","DOI":"10.1016\/j.jmbbm.2013.11.020","volume":"30","author":"AM Reyes","year":"2014","unstructured":"Reyes, A. M., Jahr, H., van Schie, H. T., Weinans, H. & Zadpoor, A. A. Prediction of the elastic strain limit of tendons. J Mech Behav Biomed Mater 30, 324\u2013338, https:\/\/doi.org\/10.1016\/j.jmbbm.2013.11.020 (2014).","journal-title":"J Mech Behav Biomed Mater"},{"key":"29583_CR10","doi-asserted-by":"publisher","first-page":"370","DOI":"10.3415\/VCOT-10-09-0128","volume":"24","author":"JE Bowser","year":"2011","unstructured":"Bowser, J. E., Elder, S. H., Rashmir-Raven, A. M. & Swiderski, C. E. A cryogenic clamping technique that facilitates ultimate tensile strength determinations in tendons and ligaments. Vet Comp Orthop Traumatol 24, 370\u2013373, https:\/\/doi.org\/10.3415\/VCOT-10-09-0128 (2011).","journal-title":"Vet Comp Orthop Traumatol"},{"key":"29583_CR11","doi-asserted-by":"crossref","first-page":"111","DOI":"10.2460\/ajvr.1996.57.01.111","volume":"57","author":"GL Matthews","year":"1996","unstructured":"Matthews, G. L., Keegan, K. G. & Graham, H. L. Effects of tendon grip technique (frozen versus unfrozen) on in vitro surface strain measurements of the equine deep digital flexor tendon. American journal of veterinary research 57, 111\u2013115 (1996).","journal-title":"American journal of veterinary research"},{"key":"29583_CR12","doi-asserted-by":"publisher","first-page":"1539","DOI":"10.1016\/j.jbiomech.2009.03.041","volume":"42","author":"AM Merican","year":"2009","unstructured":"Merican, A. M. & Amis, A. A. Iliotibial band tension affects patellofemoral and tibiofemoral kinematics. J Biomech 42, 1539\u20131546, https:\/\/doi.org\/10.1016\/j.jbiomech.2009.03.041 (2009).","journal-title":"J Biomech"},{"key":"29583_CR13","doi-asserted-by":"publisher","first-page":"2323","DOI":"10.1016\/j.jbiomech.2009.06.049","volume":"42","author":"AM Merican","year":"2009","unstructured":"Merican, A. M., Sanghavi, S., Iranpour, F. & Amis, A. A. The structural properties of the lateral retinaculum and capsular complex of the knee. J Biomech 42, 2323\u20132329, https:\/\/doi.org\/10.1016\/j.jbiomech.2009.06.049 (2009).","journal-title":"J Biomech"},{"key":"29583_CR14","doi-asserted-by":"crossref","first-page":"263","DOI":"10.1016\/S0034-5288(18)31711-9","volume":"39","author":"DJ Riemersma","year":"1985","unstructured":"Riemersma, D. J. & Schamhardt, H. C. In vitro mechanical properties of equine tendons in relation to cross-sectional area and collagen content. Res Vet Sci 39, 263\u2013270 (1985).","journal-title":"Res Vet Sci"},{"key":"29583_CR15","doi-asserted-by":"publisher","first-page":"81","DOI":"10.1016\/j.jmbbm.2012.04.025","volume":"16","author":"N Hammer","year":"2012","unstructured":"Hammer, N. et al. Ultimate stress and age-dependent deformation characteristics of the iliotibial tract. J Mech Behav Biomed Mater 16, 81\u201386, https:\/\/doi.org\/10.1016\/j.jmbbm.2012.04.025 (2012).","journal-title":"J Mech Behav Biomed Mater"},{"key":"29583_CR16","doi-asserted-by":"publisher","first-page":"112","DOI":"10.1016\/j.jmbbm.2015.04.028","volume":"49","author":"F Sichting","year":"2015","unstructured":"Sichting, F. et al. Quantification of material slippage in the iliotibial tract when applying the partial plastination clamping technique. J Mech Behav Biomed Mater 49, 112\u2013117, https:\/\/doi.org\/10.1016\/j.jmbbm.2015.04.028 (2015).","journal-title":"J Mech Behav Biomed Mater"},{"key":"29583_CR17","doi-asserted-by":"publisher","first-page":"1221","DOI":"10.1016\/j.medengphy.2011.12.009","volume":"34","author":"H Steinke","year":"2012","unstructured":"Steinke, H. et al. Deformation behavior of the iliotibial tract under different states of fixation. Med Eng Phys 34, 1221\u20131227, https:\/\/doi.org\/10.1016\/j.medengphy.2011.12.009 (2012).","journal-title":"Med Eng Phys"},{"key":"29583_CR18","doi-asserted-by":"publisher","first-page":"164","DOI":"10.1016\/j.jmbbm.2016.01.018","volume":"61","author":"N Hammer","year":"2016","unstructured":"Hammer, N. et al. A preliminary technical study on sodium dodecyl sulfate-induced changes of the nano-structural and macro-mechanical properties in human iliotibial tract specimens. J Mech Behav Biomed Mater 61, 164\u2013173, https:\/\/doi.org\/10.1016\/j.jmbbm.2016.01.018 (2016).","journal-title":"J Mech Behav Biomed Mater"},{"key":"29583_CR19","doi-asserted-by":"publisher","first-page":"e105037","DOI":"10.1371\/journal.pone.0105037","volume":"9","author":"N Hammer","year":"2014","unstructured":"Hammer, N. et al. Do cells contribute to tendon and ligament biomechanics? PLoS One 9, e105037, https:\/\/doi.org\/10.1371\/journal.pone.0105037 (2014).","journal-title":"PLoS One"},{"key":"29583_CR20","doi-asserted-by":"publisher","first-page":"3437","DOI":"10.1016\/j.jbiomech.2016.09.001","volume":"49","author":"S Schleifenbaum","year":"2016","unstructured":"Schleifenbaum, S. et al. Tensile properties of the hip joint ligaments are largely variable and age-dependent - An in-vitro analysis in an age range of 14\u201393 years. J Biomech 49, 3437\u20133443, https:\/\/doi.org\/10.1016\/j.jbiomech.2016.09.001 (2016).","journal-title":"J Biomech"},{"key":"29583_CR21","doi-asserted-by":"publisher","first-page":"e0151223","DOI":"10.1371\/journal.pone.0151223","volume":"11","author":"S Schleifenbaum","year":"2016","unstructured":"Schleifenbaum, S. et al. Acellularization-Induced Changes in Tensile Properties Are Organ Specific - An In-Vitro Mechanical and Structural Analysis of Porcine Soft Tissues. PLoS One 11, e0151223, https:\/\/doi.org\/10.1371\/journal.pone.0151223 (2016).","journal-title":"PLoS One"},{"key":"29583_CR22","doi-asserted-by":"crossref","unstructured":"Saunders, M. M. Mechanical testing for the biomechanics engineer: a practical guide.\u00a0Synthesis Lectures on Biomedical Engineering 9.3, 1\u2013276 (2015).","DOI":"10.2200\/S00616ED1V01Y201411BME054"},{"key":"29583_CR23","doi-asserted-by":"publisher","first-page":"71","DOI":"10.1016\/j.jmbbm.2013.04.005","volume":"23","author":"SF Mattucci","year":"2013","unstructured":"Mattucci, S. F., Moulton, J. A., Chandrashekar, N. & Cronin, D. S. Strain rate dependent properties of human craniovertebral ligaments. J Mech Behav Biomed Mater 23, 71\u201379, https:\/\/doi.org\/10.1016\/j.jmbbm.2013.04.005 (2013).","journal-title":"J Mech Behav Biomed Mater"},{"key":"29583_CR24","doi-asserted-by":"publisher","unstructured":"Dai, Z., Ronholm, J., Tian, Y., Sethi, B. & Cao, X. Sterilization techniques for biodegradable scaffolds in tissue engineering applications. J Tissue Eng 7, 2041731416648810, https:\/\/doi.org\/10.1177\/2041731416648810 (2016).","DOI":"10.1177\/2041731416648810"},{"key":"29583_CR25","unstructured":"Specialties, I. S. M. I. M. Plastics Compatibility with Sterilization Methods, https:\/\/www.industrialspec.com\/resources\/plastics-sterilization-compatibility (2018)."}],"container-title":["Scientific Reports"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.nature.com\/articles\/s41598-018-29583-4.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.nature.com\/articles\/s41598-018-29583-4","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.nature.com\/articles\/s41598-018-29583-4.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2024,7,8]],"date-time":"2024-07-08T14:33:32Z","timestamp":1720449212000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.nature.com\/articles\/s41598-018-29583-4"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2018,7,27]]},"references-count":25,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2018,12]]}},"alternative-id":["29583"],"URL":"https:\/\/doi.org\/10.1038\/s41598-018-29583-4","relation":{},"ISSN":["2045-2322"],"issn-type":[{"value":"2045-2322","type":"electronic"}],"subject":[],"published":{"date-parts":[[2018,7,27]]},"assertion":[{"value":"8 May 2018","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"13 July 2018","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"27 July 2018","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"The authors declare no competing interests.","order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing Interests"}}],"article-number":"11340"}}