{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,5,15]],"date-time":"2026-05-15T05:14:38Z","timestamp":1778822078854,"version":"3.51.4"},"reference-count":36,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2018,9,12]],"date-time":"2018-09-12T00:00:00Z","timestamp":1536710400000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2018,9,12]],"date-time":"2018-09-12T00:00:00Z","timestamp":1536710400000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"funder":[{"DOI":"10.13039\/501100006769","name":"Russian Science Foundation","doi-asserted-by":"publisher","award":["15-15-20012"],"award-info":[{"award-number":["15-15-20012"]}],"id":[{"id":"10.13039\/501100006769","id-type":"DOI","asserted-by":"publisher"}]},{"DOI":"10.13039\/501100006769","name":"Russian Science Foundation","doi-asserted-by":"publisher","award":["15-15-20012"],"award-info":[{"award-number":["15-15-20012"]}],"id":[{"id":"10.13039\/501100006769","id-type":"DOI","asserted-by":"publisher"}]},{"DOI":"10.13039\/501100006769","name":"Russian Science Foundation","doi-asserted-by":"publisher","award":["15-15-20012"],"award-info":[{"award-number":["15-15-20012"]}],"id":[{"id":"10.13039\/501100006769","id-type":"DOI","asserted-by":"publisher"}]},{"DOI":"10.13039\/501100006769","name":"Russian Science Foundation","doi-asserted-by":"publisher","award":["15-15-20012"],"award-info":[{"award-number":["15-15-20012"]}],"id":[{"id":"10.13039\/501100006769","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Sci Rep"],"abstract":"<jats:title>Abstract<\/jats:title><jats:p>The velocity of the pulse wave (PWV) propagating through the vascular tree is an essential parameter for diagnostic the state of the cardiovascular system especially when it is measured in the pool of carotid arteries. In this research, we showed for the first time that the time of the blood-pressure-wave propagation from the heart to the face is a function of the body position. Significant asymmetry and asynchronicity of blood pulsations in the facial area were found in a recumbent position. Parameters of blood pulsations were measured by an advanced camera-based photoplethysmography system in 73 apparently healthy subjects. Most likely, observed changes of the blood-pulsation parameters are caused by variations of the arterial blood pressure due to hydrostatic pressure changes, and secondary reaction of blood vessels in response to these variations. Demonstrated feasibility of PWV measurements in the pool of carotid arteries provides considerable advantages over other technologies. Moreover, possibilities of the method to estimate physiological regulation of the peripheral blood flow (particularly, as a response to the gravitational changes) have been demonstrated. The proposed concept allows development of non-invasive medical equipment capable of solving a wide range of scientific and practical problems related to vascular physiology.<\/jats:p>","DOI":"10.1038\/s41598-018-32036-7","type":"journal-article","created":{"date-parts":[[2018,9,6]],"date-time":"2018-09-06T09:39:52Z","timestamp":1536226792000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":30,"title":["Alterations of blood pulsations parameters in carotid basin due to body position change"],"prefix":"10.1038","volume":"8","author":[{"ORCID":"https:\/\/orcid.org\/0000-0003-2506-9736","authenticated-orcid":false,"given":"Alexei A.","family":"Kamshilin","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Tatiana V.","family":"Krasnikova","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Maxim A.","family":"Volynsky","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-4069-9229","authenticated-orcid":false,"given":"Serguei V.","family":"Miridonov","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Oleg V.","family":"Mamontov","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2018,9,12]]},"reference":[{"key":"32036_CR1","doi-asserted-by":"publisher","first-page":"1111","DOI":"10.1161\/01.HYP.33.5.1111","volume":"33","author":"J Blacher","year":"1999","unstructured":"Blacher, J., Asmar, R., Djane, S., London, G. M. & Safar, M. E. Aortic pulse wave velocity as a marker of cardiovascular risk in hypertensive patients. Hypertension 33, 1111\u20131117 (1999).","journal-title":"Hypertension"},{"key":"32036_CR2","doi-asserted-by":"publisher","first-page":"165","DOI":"10.1016\/S0895-7061(99)00192-2","volume":"13","author":"LA Bortolotto","year":"2000","unstructured":"Bortolotto, L. A., Blacher, J., Kondo, T., Takazawa, K. & Safar, M. E. Assessment of vascular aging and atherosclerosis in hypertensive subjects: second derivative of photoplethysmogram versus pulse wave velocity. Am. J. Hypertens. 13, 165\u2013171 (2000).","journal-title":"Am. J. Hypertens."},{"key":"32036_CR3","doi-asserted-by":"publisher","first-page":"86","DOI":"10.1111\/j.1469-8986.1976.tb03344.x","volume":"13","author":"B Gribbin","year":"1976","unstructured":"Gribbin, B., Steptoe, A. & Sleight, P. Pulse wave velocity as a measure of blood pressure change. Psychophysiology 13, 86\u201390 (1976).","journal-title":"Psychophysiology"},{"key":"32036_CR4","doi-asserted-by":"publisher","first-page":"581","DOI":"10.1088\/0967-3334\/23\/3\/309","volume":"23","author":"S Loukogeorgakis","year":"2002","unstructured":"Loukogeorgakis, S., Dawson, R., Philips, N., Martyn, C. N. & Greenwald, S. E. Validation of a device to measure arterial pulse wave velocity by a photoplethysmographic method. Physiol. Meas. 23, 581\u2013596 (2002).","journal-title":"Physiol. Meas."},{"key":"32036_CR5","doi-asserted-by":"publisher","first-page":"1456","DOI":"10.1161\/01.CIR.88.4.1456","volume":"88","author":"PV Vaitkevicius","year":"1993","unstructured":"Vaitkevicius, P. V. et al. Effects of age and aerobic capacity on arterial stiffness in healthy adults. Circulation 88, 1456\u20131462 (1993).","journal-title":"Circulation"},{"key":"32036_CR6","doi-asserted-by":"publisher","first-page":"1411","DOI":"10.1097\/HJH.0b013e3282ffac00","volume":"26","author":"SJ Vermeersch","year":"2008","unstructured":"Vermeersch, S. J. et al. Age and gender related patterns in carotid-femoral PWV and carotid and femoral stiffness in a large healthy, middle-aged population. J. Hypertens. 26, 1411\u20131419 (2008).","journal-title":"J. Hypertens."},{"key":"32036_CR7","doi-asserted-by":"publisher","first-page":"54","DOI":"10.1007\/BF02513266","volume":"37","author":"M Nitzan","year":"1999","unstructured":"Nitzan, M., Babchenko, A. & Khanokh, B. Very low frequency variability in arterial blood pressure and blood volume pulse. Med. Biol. Eng. Comput. 37, 54\u201358 (1999).","journal-title":"Med. Biol. Eng. Comput."},{"key":"32036_CR8","doi-asserted-by":"publisher","first-page":"485","DOI":"10.1161\/01.HYP.26.3.485","volume":"26","author":"R Asmar","year":"1995","unstructured":"Asmar, R. et al. Assessment of arterial distensibility by automatic pulse wave velocity measurement. Hypertension 26, 485\u2013490 (1995).","journal-title":"Hypertension"},{"key":"32036_CR9","doi-asserted-by":"publisher","first-page":"555","DOI":"10.1007\/s40846-015-0086-8","volume":"35","author":"T Pereira","year":"2015","unstructured":"Pereira, T., Correia, C. & Cardoso, J. Novel methods for pulse wave velocity measurement. J. Med. Biol. Eng. 35, 555\u2013565 (2015).","journal-title":"J. Med. Biol. Eng."},{"key":"32036_CR10","doi-asserted-by":"publisher","first-page":"136","DOI":"10.1152\/japplphysiol.00657.2005","volume":"100","author":"RA Payne","year":"2006","unstructured":"Payne, R. A., Symeonidis, C. N., Webb, D. J. & Maxwell, S. R. J. Pulse transit time measured from the ECG: an unreliable marker of beat-to-beat blood pressure. J. Appl. Physiol. 100, 136\u2013141 (2006).","journal-title":"J. Appl. Physiol."},{"key":"32036_CR11","doi-asserted-by":"publisher","first-page":"1669","DOI":"10.1183\/09031936.95.08101669","volume":"8","author":"D Pitson","year":"1995","unstructured":"Pitson, D., Sandell, A., van den Hout, R. & Stradling, J. Use of pulse transit time as a measure of inspiratory effort in patients with obstructive sleep apnoea. Eur. Respir. J. 8, 1669\u20131674 (1995).","journal-title":"Eur. Respir. J."},{"key":"32036_CR12","doi-asserted-by":"publisher","first-page":"669","DOI":"10.1042\/cs0950669","volume":"95","author":"Y-L Liang","year":"1998","unstructured":"Liang, Y.-L. et al. Non-invasive measurements of arterial structure and function: repeatability, interrelationships and trial sample size. Clin. Sci. 95, 669\u2013679 (1998).","journal-title":"Clin. Sci."},{"key":"32036_CR13","doi-asserted-by":"publisher","first-page":"2079","DOI":"10.1097\/00004872-199816121-00033","volume":"16","author":"IB Wilkinson","year":"1998","unstructured":"Wilkinson, I. B. et al. Reproducibility of pulse wave velocity and augmentation index measured by pulse wave analysis. J. Hypertens. 16, 2079\u20132084 (1998).","journal-title":"J. Hypertens."},{"key":"32036_CR14","doi-asserted-by":"publisher","DOI":"10.1007\/s10916-016-0558-6","volume":"40","author":"Y Zheng","year":"2016","unstructured":"Zheng, Y., Poon, C. C. Y., Yan, B. P. & Lau, J. Y. W. Pulse arrival time based cuff-less and 24-h wearable blood pressure monitoring and its diagnostic value in hypertension. J. Med. Syst. 40, 195 (2016).","journal-title":"J. Med. Syst."},{"key":"32036_CR15","doi-asserted-by":"publisher","first-page":"871","DOI":"10.1007\/s10439-011-0467-2","volume":"40","author":"Y Chen","year":"2012","unstructured":"Chen, Y., Wen, C., Tao, G. & Bi, M. Continuous and noninvasive measurement of systolic and diastolic blood pressure by one mathematical model with the same model parameters and two separate pulse wave velocities. Ann. Biomed. Eng. 40, 871\u2013882 (2012).","journal-title":"Ann. Biomed. Eng."},{"key":"32036_CR16","doi-asserted-by":"crossref","unstructured":"Nakano, K., Ohnishi, T., Nishidate, I. & Haneishi, H. Noncontact sphygmomanometer based on pulse-wave transit time between the face and hand. In Optical Diagnostics and Sensing XVIII: Toward Point-of-Care Diagnostics (ed. Cot\u00e9, G. L.). Proc. SPIE 10501, 1050110 (2018).","DOI":"10.1117\/12.2289349"},{"key":"32036_CR17","doi-asserted-by":"publisher","first-page":"1879","DOI":"10.1109\/TBME.2015.2441951","volume":"62","author":"R Mukkamala","year":"2015","unstructured":"Mukkamala, R. et al. Towards ubiquitous blood pressure monitoring via pulse transit time: theory and practice. IEEE Trans. Biomed. Eng. 62, 1879\u20131910 (2015).","journal-title":"IEEE Trans. Biomed. Eng."},{"key":"32036_CR18","doi-asserted-by":"publisher","first-page":"21","DOI":"10.3390\/technologies5020021","volume":"5","author":"M Sharma","year":"2017","unstructured":"Sharma, M. et al. Cuff-less and continuous blood pressure monitoring: a methodological review. Technologies 5, 21 (2017).","journal-title":"Technologies"},{"key":"32036_CR19","doi-asserted-by":"publisher","first-page":"47","DOI":"10.3389\/fphys.2017.00047","volume":"8","author":"Y Obata","year":"2017","unstructured":"Obata, Y. et al. Noninvasive assessment of the effect of position and exercise on pulse arrival to peripheral vascular beds in healthy volunteers. Front. Physiol. 8, 47 (2017).","journal-title":"Front. Physiol."},{"key":"32036_CR20","doi-asserted-by":"publisher","first-page":"727","DOI":"10.1007\/s10877-015-9761-0","volume":"30","author":"M Hickey","year":"2016","unstructured":"Hickey, M., Phillips, J. P. & Kyriacou, P. A. Investigation of peripheral photoplethysmographic morphology changes induced during a hand-elevation study. J. Clin. Monit. Comput. 30, 727\u2013736 (2016).","journal-title":"J. Clin. Monit. Comput."},{"key":"32036_CR21","doi-asserted-by":"publisher","first-page":"855","DOI":"10.3389\/fphys.2017.00855","volume":"8","author":"A Tripathy","year":"2017","unstructured":"Tripathy, A. et al. A pulse wave velocity based method to assess the mean arterial blood pressure limits of autoregulation in peripheral arteries. Front. Physiol. 8, 855 (2017).","journal-title":"Front. Physiol."},{"key":"32036_CR22","doi-asserted-by":"crossref","unstructured":"Erts, R., Kukulis, I., Spigulis, J. & Kere, L. Dual channel photoplethysmography studies of cardio-vascular response to the body position changes. In Photon Migration andDiffuse-Light Imaging II (eds Licha, K. & Cubeddu, R.). Proc. SPIE 5859, 58591K (2005).","DOI":"10.1117\/12.632883"},{"key":"32036_CR23","doi-asserted-by":"publisher","first-page":"916","DOI":"10.1631\/jzus.2007.A0916","volume":"8","author":"S-Z Xin","year":"2007","unstructured":"Xin, S.-Z. et al. Investigation of blood pulse PPG signal regulation on toe effect of body posture and lower limb height. J. Zhejiang Univ. - Sci. A Appl. Phys. Eng. 8, 916\u2013920 (2007).","journal-title":"J. Zhejiang Univ. - Sci. A Appl. Phys. Eng."},{"key":"32036_CR24","doi-asserted-by":"publisher","first-page":"2116","DOI":"10.1016\/j.jacc.2015.08.888","volume":"66","author":"TT van Sloten","year":"2015","unstructured":"van Sloten, T. T. et al. Carotid stiffness is associated with incident stroke: A systematic review and individual participant data meta-analysis. J. Am. Coll. Cardiol. 66, 2116\u20132125 (2015).","journal-title":"J. Am. Coll. Cardiol."},{"key":"32036_CR25","doi-asserted-by":"publisher","first-page":"21434","DOI":"10.1364\/OE.16.021434","volume":"16","author":"W Verkruysse","year":"2008","unstructured":"Verkruysse, W., Svaasand, L. O. & Nelson, J. S. Remote plethysmographic imaging using ambient light. Opt. Express 16, 21434\u201321445 (2008).","journal-title":"Opt. Express"},{"key":"32036_CR26","doi-asserted-by":"publisher","first-page":"996","DOI":"10.1364\/BOE.2.000996","volume":"2","author":"AA Kamshilin","year":"2011","unstructured":"Kamshilin, A. A., Miridonov, S., Teplov, V., Saarenheimo, R. & Nippolainen, E. Photoplethysmographic imaging of high spatial resolution. Biomed. Opt. Express 2, 996\u20131006 (2011).","journal-title":"Biomed. Opt. Express"},{"key":"32036_CR27","doi-asserted-by":"publisher","first-page":"5138","DOI":"10.1364\/BOE.7.005138","volume":"7","author":"AA Kamshilin","year":"2016","unstructured":"Kamshilin, A. A. et al. Accurate measurement of the pulse wave delay with imaging photoplethysmography. Biomed. Opt. Express 7, 5138\u20135147 (2016).","journal-title":"Biomed. Opt. Express"},{"key":"32036_CR28","doi-asserted-by":"publisher","DOI":"10.1038\/s41598-017-13552-4","volume":"7","author":"MV Volkov","year":"2017","unstructured":"Volkov, M. V. et al. Video capillaroscopy clarifies mechanism of the photoplethysmographic waveform appearance. Sci. Rep. 7, 13298 (2017).","journal-title":"Sci. Rep."},{"key":"32036_CR29","doi-asserted-by":"publisher","DOI":"10.1038\/srep10494","volume":"5","author":"AA Kamshilin","year":"2015","unstructured":"Kamshilin, A. A. et al. A new look at the essence of the imaging photoplethysmography. Sci. Rep. 5, 10494 (2015).","journal-title":"Sci. Rep."},{"key":"32036_CR30","doi-asserted-by":"publisher","first-page":"R1","DOI":"10.1088\/0967-3334\/28\/3\/R01","volume":"28","author":"J Allen","year":"2007","unstructured":"Allen, J. Photoplethysmography and its application in clinical physiological measurement. Physiol. Meas. 28, R1\u2013R39 (2007).","journal-title":"Physiol. Meas."},{"key":"32036_CR31","doi-asserted-by":"publisher","first-page":"1737","DOI":"10.1364\/BOE.7.001737","volume":"7","author":"AV Mo\u00e7o","year":"2016","unstructured":"Mo\u00e7o, A. V., Stuijk, S. & de Haan, G. Motion robust PPG-imaging through color channel mapping. Biomed. Opt. Express 7, 1737\u20131754 (2016).","journal-title":"Biomed. Opt. Express"},{"key":"32036_CR32","doi-asserted-by":"publisher","DOI":"10.1186\/s10194-018-0872-0","volume":"19","author":"AA Kamshilin","year":"2018","unstructured":"Kamshilin, A. A. et al. Novel capsaicin-induced parameters of microcirculation in migraine patients revealed by imaging photoplethysmography. J. Headache Pain 19, 43 (2018).","journal-title":"J. Headache Pain"},{"key":"32036_CR33","doi-asserted-by":"publisher","first-page":"1332","DOI":"10.1093\/ajh\/hpv043","volume":"28","author":"R Kalfon","year":"2015","unstructured":"Kalfon, R., Campbell, J., Alvarez-Alvarado, S. & Figueroa, A. Aortic hemodynamics and arterial stiffness responses to muscle metaboreflex activation with concurrent cold pressor test. Am. J. Hypertens. 28, 1332\u20131338 (2015).","journal-title":"Am. J. Hypertens."},{"key":"32036_CR34","doi-asserted-by":"publisher","first-page":"2469","DOI":"10.1364\/BOE.7.002469","volume":"7","author":"IS Sidorov","year":"2016","unstructured":"Sidorov, I. S., Volynsky, M. A. & Kamshilin, A. A. Influence of polarization filtration on the information readout from pulsating blood vessels. Biomed. Opt. Express 7, 2469\u20132474 (2016).","journal-title":"Biomed. Opt. Express"},{"key":"32036_CR35","doi-asserted-by":"publisher","first-page":"185","DOI":"10.1016\/0004-3702(81)90024-2","volume":"17","author":"BKP Horn","year":"1981","unstructured":"Horn, B. K. P. & Schunk, B. G. Determining optical flow. Artif. Intellegence 17, 185\u2013201 (1981).","journal-title":"Artif. Intellegence"},{"key":"32036_CR36","doi-asserted-by":"publisher","first-page":"229","DOI":"10.1109\/TPAMI.1987.4767897","volume":"PAMI-9","author":"JK Kearney","year":"1987","unstructured":"Kearney, J. K., Thompson, W. B. & Boley, D. L. Optical flow estimation: An error analysis of gradient-based methods with local optimization. IEEE Trans. Pattern Anal. Mach. Intell. PAMI-9, 229\u2013244 (1987).","journal-title":"IEEE Trans. Pattern Anal. Mach. Intell."}],"container-title":["Scientific Reports"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.nature.com\/articles\/s41598-018-32036-7.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.nature.com\/articles\/s41598-018-32036-7","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.nature.com\/articles\/s41598-018-32036-7.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2022,12,21]],"date-time":"2022-12-21T09:33:11Z","timestamp":1671615191000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.nature.com\/articles\/s41598-018-32036-7"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2018,9,12]]},"references-count":36,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2018,12]]}},"alternative-id":["32036"],"URL":"https:\/\/doi.org\/10.1038\/s41598-018-32036-7","relation":{},"ISSN":["2045-2322"],"issn-type":[{"value":"2045-2322","type":"electronic"}],"subject":[],"published":{"date-parts":[[2018,9,12]]},"assertion":[{"value":"15 June 2018","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"28 August 2018","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"12 September 2018","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"The authors declare no competing interests.","order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing Interests"}}],"article-number":"13663"}}