{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,8,3]],"date-time":"2025-08-03T23:03:29Z","timestamp":1754262209757,"version":"3.37.3"},"reference-count":17,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2019,3,7]],"date-time":"2019-03-07T00:00:00Z","timestamp":1551916800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2019,3,7]],"date-time":"2019-03-07T00:00:00Z","timestamp":1551916800000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Sci Rep"],"abstract":"<jats:title>Abstract<\/jats:title><jats:p>Constant-voltage and constant-current stimulators may be used for transcranial electrical stimulation of motor evoked potentials (TES-MEP). However, no previous report has determined whether the two monophasic stimulation methods lead to similar responses during intra-operative monitoring. We studied differences in the lateralities of compound muscle action potentials (CMAPs) during intra-operative spinal cord monitoring via TES-MEP using monophasic constant-current and constant-voltage stimulations. CMAPs were bilaterally recorded from the upper and lower limb muscles in 95 patients who underwent elective spine and spinal cord surgery. We used two monophasic stimulation patterns: pattern 1, right anode and left cathode; pattern 2, right cathode and left anode. There were no statistically significant differences between the right and left sides with respect to success rates, wave amplitudes, and efficiencies, with constant-voltage stimulation, however, there were statistically significant differences between the right and left sides with constant-current stimulation. In case of our stimulation condition, there were no statistically significant differences between the right and left sides with respect to CMAPs with constant-voltage stimulation; constant-current stimulation was influenced by the type of monophasic stimulation, which necessitates the switch the polarity of the stimulation to bilaterally record CMAPs.<\/jats:p>","DOI":"10.1038\/s41598-019-39883-y","type":"journal-article","created":{"date-parts":[[2019,3,7]],"date-time":"2019-03-07T11:04:07Z","timestamp":1551956647000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":6,"title":["Monophasic transcranial constant-current versus constant-voltage stimulation of motor-evoked potentials during spinal surgery"],"prefix":"10.1038","volume":"9","author":[{"given":"Keisuke","family":"Masuda","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-0892-3382","authenticated-orcid":false,"given":"Hideki","family":"Shigematsu","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Masato","family":"Tanaka","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Eiichiro","family":"Iwata","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Yusuke","family":"Yamamoto","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Masahiko","family":"Kawaguchi","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Tsunenori","family":"Takatani","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Sachiko","family":"Kawasaki","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Yasuhito","family":"Tanaka","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2019,3,7]]},"reference":[{"key":"39883_CR1","doi-asserted-by":"publisher","first-page":"911","DOI":"10.2106\/00004623-198870060-00016","volume":"70","author":"M Machida","year":"1988","unstructured":"Machida, M. et al. Monitoring of motor action potentials after stimulation of the spinal cord. J Bone Joint Surg Am. 70, 911\u2013918 (1988).","journal-title":"J Bone Joint Surg Am."},{"key":"39883_CR2","doi-asserted-by":"publisher","first-page":"2240","DOI":"10.1097\/00007632-199510001-00011","volume":"20","author":"K Mochida","year":"1995","unstructured":"Mochida, K., Shinomiya, K., Komori, H. & Furuya, K. A new method of multisegment motor pathway monitoring using muscle potentials after train spinal stimulation. Spine. 20, 2240\u20132246 (1995).","journal-title":"Spine."},{"key":"39883_CR3","doi-asserted-by":"publisher","first-page":"709","DOI":"10.1227\/00006123-198905000-00008","volume":"24","author":"J Zentner","year":"1989","unstructured":"Zentner, J. Noninvasive motor evoked potential monitoring during neurosurgical operations on the spinal cord. Neurosurgery. 24, 709\u2013712 (1989).","journal-title":"Neurosurgery."},{"key":"39883_CR4","doi-asserted-by":"publisher","first-page":"375","DOI":"10.1016\/0168-5597(96)95728-7","volume":"100","author":"SJ Jones","year":"1996","unstructured":"Jones, S. J., Harrison, R., Koh, K. F., Mendoza, N. & Crockard, H. A. Motor evoked potential monitoring during spinal surgery: responses of distal limb muscles to transcranial cortical stimulation with pulse trains. Electroencephalogr Clin Neurophysiol. 100, 375\u2013383 (1996).","journal-title":"Electroencephalogr Clin Neurophysiol."},{"key":"39883_CR5","doi-asserted-by":"publisher","first-page":"1472","DOI":"10.1016\/j.spinee.2017.05.004","volume":"17","author":"H Shigematsu","year":"2017","unstructured":"Shigematsu, H. et al. Higher success rate with transcranial electrical stimulation of motor-evoked potentials using constant-voltage stimulation compared with constant-current stimulation in patients undergoing spinal surgery. Spine J. 17, 1472\u20131479 (2017).","journal-title":"Spine J."},{"key":"39883_CR6","doi-asserted-by":"publisher","first-page":"2291","DOI":"10.1016\/j.clinph.2013.07.025","volume":"124","author":"DB Macdonald","year":"2013","unstructured":"Macdonald, D. B., Skinner, S., Shils, J. & Yingling, C. Intraoperative motor evoked potential monitoring - a position statement by the American Society of Neurophysiological Monitoring. Clin Neurophysiol. 124, 2291\u20132316 (2013).","journal-title":"Clin Neurophysiol."},{"key":"39883_CR7","doi-asserted-by":"crossref","unstructured":"Pechstein, U., Cedzich, C., Nadstawek, J., Schramm, J. Transcranial high-frequency repetitive electrical stimulation for recording myogenic motor evoked potentials with the patient under general anesthesia. Neurosurgery. 39, 335\u2013343, discussion 43\u201344 (1996).","DOI":"10.1097\/00006123-199608000-00020"},{"key":"39883_CR8","doi-asserted-by":"publisher","first-page":"42","DOI":"10.1097\/WNP.0000000000000253","volume":"33","author":"AD Legatt","year":"2016","unstructured":"Legatt, A. D. et al. ACNS guideline: transcranial electrical stimulation sotor evoked potential monitoring. J Clin Neurophysiol. 33, 42\u201350 (2016).","journal-title":"J Clin Neurophysiol."},{"key":"39883_CR9","doi-asserted-by":"publisher","first-page":"303","DOI":"10.1007\/s10877-005-5097-5","volume":"18","author":"Z Chen","year":"2004","unstructured":"Chen, Z. The effects of isoflurane and propofol on intraoperative neurophysiological monitoring during spinal surgery. J Clin Monit Comput. 18, 303\u2013308 (2004).","journal-title":"J Clin Monit Comput."},{"key":"39883_CR10","doi-asserted-by":"publisher","first-page":"25","DOI":"10.1152\/ajplegacy.1964.206.1.25","volume":"206","author":"M Reivich","year":"1964","unstructured":"Reivich, M. Arterial Pco2 and cerebral hemodynamics. Am J Physiol. 206, 25\u201335 (1964).","journal-title":"Am J Physiol."},{"key":"39883_CR11","first-page":"1007","volume":"80","author":"K Leslie","year":"1995","unstructured":"Leslie, K., Sessler, D. I., Bjorksten, A. R. & Moayeri, A. Mild hypothermia alters propofol pharmacokinetics and increases the duration of action of atracurium. Anesth Analg. 80, 1007\u20131014 (1995).","journal-title":"Anesth Analg."},{"key":"39883_CR12","doi-asserted-by":"publisher","first-page":"409","DOI":"10.1097\/00004691-200210000-00004","volume":"19","author":"M Seyal","year":"2002","unstructured":"Seyal, M. & Mull, B. Mechanisms of signal change during intraoperative somatosensory evoked potential monitoring of the spinal cord. J Clin Neurophysiol. 19, 409\u2013415 (2002).","journal-title":"J Clin Neurophysiol."},{"key":"39883_CR13","first-page":"13","volume":"17","author":"R Lyon","year":"2005","unstructured":"Lyon, R., Feiner, J. & Lieberman, J. A. Progressive suppression of motor evoked potentials during general anesthesia: the phenomenon of \u201canesthetic fade\u201d. J Neurosurg Anesthesiol. 17, 13\u201319 (2005).","journal-title":"J Neurosurg Anesthesiol."},{"key":"39883_CR14","first-page":"1043","volume":"28","author":"DD Langeloo","year":"2003","unstructured":"Langeloo, D. D., Lelivelt, A., Louis Journee, H., Slappendel, R. & de Kleuver, M. Transcranial electrical motor-evoked potential monitoring during surgery for spinal deformity: a study of 145 patients. Spine. 28, 1043\u20131050 (2003).","journal-title":"Spine."},{"key":"39883_CR15","doi-asserted-by":"crossref","unstructured":"Sala, F. et al. Motor evoked potential monitoring improves outcome after surgery for intramedullary spinal cord tumors: a historical control study. Neurosurgery. 58, 1129\u20131143, discussion \u201343 (2006).","DOI":"10.1227\/01.NEU.0000215948.97195.58"},{"key":"39883_CR16","doi-asserted-by":"publisher","first-page":"102","DOI":"10.1007\/s776-002-8430-x","volume":"7","author":"Y Nakagawa","year":"2002","unstructured":"Nakagawa, Y., Tamaki, T., Yamada, H. & Nishiura, H. Discrepancy between decreases in the amplitude of compound muscle action potential and loss of motor function caused by ischemic and compressive insults to the spinal cord. J Orthop Sci. 7, 102\u2013110 (2002).","journal-title":"J Orthop Sci."},{"key":"39883_CR17","doi-asserted-by":"publisher","first-page":"E159","DOI":"10.1097\/BRS.0000000000000082","volume":"39","author":"D Ukegawa","year":"2014","unstructured":"Ukegawa, D. et al. Efficacy of biphasic transcranial electric stimulation in intraoperative motor evoked potential monitoring for cervical compression myelopathy. Spine. 39, E159\u2013E165 (2014).","journal-title":"Spine."}],"container-title":["Scientific Reports"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.nature.com\/articles\/s41598-019-39883-y.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.nature.com\/articles\/s41598-019-39883-y","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.nature.com\/articles\/s41598-019-39883-y.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2022,12,17]],"date-time":"2022-12-17T07:17:46Z","timestamp":1671261466000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.nature.com\/articles\/s41598-019-39883-y"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2019,3,7]]},"references-count":17,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2019,12]]}},"alternative-id":["39883"],"URL":"https:\/\/doi.org\/10.1038\/s41598-019-39883-y","relation":{},"ISSN":["2045-2322"],"issn-type":[{"type":"electronic","value":"2045-2322"}],"subject":[],"published":{"date-parts":[[2019,3,7]]},"assertion":[{"value":"14 May 2018","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"25 January 2019","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"7 March 2019","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"The authors declare no competing interests.","order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing Interests"}}],"article-number":"3773"}}