{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,11,7]],"date-time":"2026-11-07T22:48:59Z","timestamp":1794091739268,"version":"4.8.0"},"reference-count":44,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2019,2,28]],"date-time":"2019-02-28T00:00:00Z","timestamp":1551312000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2019,2,28]],"date-time":"2019-02-28T00:00:00Z","timestamp":1551312000000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Sci Rep"],"abstract":"<jats:title>Abstract<\/jats:title><jats:p>Robustness against data inconsistencies, imaging artifacts and acquisition speed are crucial factors limiting the possible range of applications for magnetic resonance imaging (MRI). Therefore, we report a novel calibrationless parallel imaging technique which simultaneously estimates coil profiles and image content in a relaxed forward model. Our method is robust against a wide class of data inconsistencies, minimizes imaging artifacts and is comparably fast, combining important advantages of many conceptually different state-of-the-art parallel imaging approaches. Depending on the experimental setting, data can be undersampled well below the Nyquist limit. Here, even high acceleration factors yield excellent imaging results while being robust to noise and the occurrence of phase singularities in the image domain, as we show on different data. Moreover, our method successfully reconstructs acquisitions with insufficient field-of-view. We further compare our approach to ESPIRiT and SAKE using spin-echo and gradient echo MRI data from the human head and knee. In addition, we show its applicability to non-Cartesian imaging on radial FLASH cardiac MRI data. Using theoretical considerations, we show that ENLIVE can be related to a low-rank formulation of blind multi-channel deconvolution, explaining why it inherently promotes low-rank solutions.<\/jats:p>","DOI":"10.1038\/s41598-019-39888-7","type":"journal-article","created":{"date-parts":[[2019,2,28]],"date-time":"2019-02-28T11:05:03Z","timestamp":1551351903000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":32,"title":["ENLIVE: An Efficient Nonlinear Method for Calibrationless and Robust Parallel Imaging"],"prefix":"10.1038","volume":"9","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-8619-0444","authenticated-orcid":false,"given":"H. Christian M.","family":"Holme","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Sebastian","family":"Rosenzweig","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Frank","family":"Ong","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Robin N.","family":"Wilke","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Michael","family":"Lustig","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-8850-809X","authenticated-orcid":false,"given":"Martin","family":"Uecker","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2019,2,28]]},"reference":[{"key":"39888_CR1","doi-asserted-by":"publisher","first-page":"952","DOI":"10.1002\/(SICI)1522-2594(199911)42:5<952::AID-MRM16>3.0.CO;2-S","volume":"42","author":"KP Pruessmann","year":"1999","unstructured":"Pruessmann, K. P., Weiger, M., Scheidegger, M. B. & Boesiger, P. SENSE: sensitivity encoding for fast MRI. Magn. Reson. Med. 42, 952\u2013962 (1999).","journal-title":"Magn. Reson. Med."},{"key":"39888_CR2","doi-asserted-by":"publisher","first-page":"1202","DOI":"10.1002\/mrm.10171","volume":"47","author":"MA Griswold","year":"2002","unstructured":"Griswold, M. A. et al. Generalized autocalibrating partially parallel acquisitions (GRAPPA). Magn. Reson. Med. 47, 1202\u20131210 (2002).","journal-title":"Magn. Reson. Med."},{"key":"39888_CR3","doi-asserted-by":"publisher","first-page":"1196","DOI":"10.1002\/mrm.21245","volume":"57","author":"L Ying","year":"2007","unstructured":"Ying, L. & Sheng, J. Joint image reconstruction and sensitivity estimation in SENSE (JSENSE). Magn. Reson. Med. 57, 1196\u20131202 (2007).","journal-title":"Magn. Reson. Med."},{"key":"39888_CR4","doi-asserted-by":"publisher","first-page":"674","DOI":"10.1002\/mrm.21691","volume":"60","author":"M Uecker","year":"2008","unstructured":"Uecker, M., Hohage, T., Block, K. T. & Frahm, J. Image reconstruction by regularized nonlinear inversion-joint estimation of coil sensitivities and image content. Magn. Reson. Med. 60, 674\u2013682 (2008).","journal-title":"Magn. Reson. Med."},{"key":"39888_CR5","doi-asserted-by":"publisher","first-page":"959","DOI":"10.1002\/mrm.24997","volume":"72","author":"PJ Shin","year":"2014","unstructured":"Shin, P. J. et al. Calibrationless parallel imaging reconstruction based on structured low-rank matrix completion. Magn. Reson. Med. 72, 959\u2013970, https:\/\/doi.org\/10.1002\/mrm.24997 (2014).","journal-title":"Magn. Reson. Med."},{"key":"39888_CR6","doi-asserted-by":"publisher","first-page":"668","DOI":"10.1109\/TMI.2013.2293974","volume":"33","author":"JP Haldar","year":"2014","unstructured":"Haldar, J. P. Low-Rank Modeling of Local k-Space Neighborhoods (LORAKS) for Constrained MRI. IEEE Trans. Med. Imag. 33, 668\u2013681, https:\/\/doi.org\/10.1109\/TMI.2013.2293974 (2014).","journal-title":"Med. Imag."},{"key":"39888_CR7","doi-asserted-by":"publisher","first-page":"1499","DOI":"10.1002\/mrm.25717","volume":"75","author":"JP Haldar","year":"2016","unstructured":"Haldar, J. P. & Zhuo, J. P-LORAKS: Low-rank modeling of local k-space neighborhoods with parallel imaging data. Magn. Reson. Med. 75, 1499\u20131514, https:\/\/doi.org\/10.1002\/mrm.25717 (2016).","journal-title":"Magn. Reson. Med."},{"key":"39888_CR8","doi-asserted-by":"crossref","unstructured":"Trzasko, J. D. & Manduca, A. Calibrationless parallel MRI using CLEAR. In Conf. Rec. Asilomar Conf. Signals Syst. Comput., 45, 75\u201379 (Pacific Grove, 2011).","DOI":"10.1109\/ACSSC.2011.6189958"},{"key":"39888_CR9","doi-asserted-by":"publisher","first-page":"990","DOI":"10.1002\/mrm.24751","volume":"71","author":"M Uecker","year":"2014","unstructured":"Uecker, M. et al. ESPIRiT-an eigenvalue approach to autocalibrating parallel MRI: where SENSE meets GRAPPA. Magn. Reson. Med. 71, 990\u20131001 (2014).","journal-title":"Magn. Reson. Med."},{"key":"39888_CR10","doi-asserted-by":"publisher","first-page":"1118","DOI":"10.1002\/mrm.20249","volume":"52","author":"MA Griswold","year":"2004","unstructured":"Griswold, M. A., Kannengiesser, S., Heidemann, R. M., Wang, J. & Jakob, P. M. Field-of-view limitations in parallel imaging. Magn. Reson. Med. 52, 1118\u20131126, https:\/\/doi.org\/10.1002\/mrm.20249 (2004).","journal-title":"Magn. Reson. Med."},{"key":"39888_CR11","doi-asserted-by":"publisher","first-page":"1201","DOI":"10.1002\/mrm.26191","volume":"77","author":"M Uecker","year":"2017","unstructured":"Uecker, M. & Lustig, M. Estimating absolute-phase maps using ESPIRiT and virtual conjugate coils. Magn. Reson. Med. 77, 1201\u20131207, https:\/\/doi.org\/10.1002\/mrm.26191 (2017).","journal-title":"Magn. Reson. Med."},{"key":"39888_CR12","unstructured":"Holme, H. C. M. et al. ENLIVE: A Non-Linear Calibrationless Method for Parallel Imaging using a Low-Rank Constraint. In Proc. Intl. Soc. Mag. Reson. Med., 25, 5160 (Honolulu, 2017)."},{"key":"39888_CR13","doi-asserted-by":"publisher","first-page":"43","DOI":"10.1109\/79.489268","volume":"13","author":"D Kundur","year":"1996","unstructured":"Kundur, D. & Hatzinakos, D. Blind image deconvolution. IEEE Signal Process. Mag. 13, 43\u201364, https:\/\/doi.org\/10.1109\/79.489268 (1996).","journal-title":"IEEE Signal Process. Mag."},{"key":"39888_CR14","doi-asserted-by":"publisher","first-page":"1711","DOI":"10.1109\/TIT.2013.2294644","volume":"60","author":"A Ahmed","year":"2014","unstructured":"Ahmed, A., Recht, B. & Romberg, J. Blind Deconvolution Using Convex Programming. IEEE Trans. Inf. Theory 60, 1711\u20131732 (2014).","journal-title":"IEEE Trans. Inf. Theory"},{"key":"39888_CR15","doi-asserted-by":"publisher","first-page":"608","DOI":"10.1109\/JSTSP.2016.2539100","volume":"10","author":"MA Davenport","year":"2016","unstructured":"Davenport, M. A. & Romberg, J. An Overview of Low-Rank Matrix Recovery From Incomplete Observations. IEEE J. Sel. Top. Signa. 10, 608\u2013622, https:\/\/doi.org\/10.1109\/JSTSP.2016.2539100 (2016).","journal-title":"IEEE J. Sel. Top. Signa."},{"key":"39888_CR16","doi-asserted-by":"publisher","first-page":"471","DOI":"10.1137\/070697835","volume":"52","author":"B Recht","year":"2010","unstructured":"Recht, B., Fazel, M. & Parrilo, P. A. Guaranteed Minimum-Rank Solutions of Linear Matrix Equations via Nuclear Norm Minimization. SIAM Rev. 52, 471\u2013501 (2010).","journal-title":"SIAM Rev."},{"key":"39888_CR17","doi-asserted-by":"publisher","first-page":"592","DOI":"10.1109\/29.17545","volume":"37","author":"EM Haacke","year":"1989","unstructured":"Haacke, E. M., Liang, Z. P. & Izen, S. H. Superresolution reconstruction through object modeling and parameter estimation. IEEE Trans. Acoust., Speech, Signal Process. 37, 592\u2013595, https:\/\/doi.org\/10.1109\/29.17545 (1989).","journal-title":"IEEE Trans. Acoust., Speech, Signal Process."},{"key":"39888_CR18","doi-asserted-by":"publisher","first-page":"480","DOI":"10.1109\/TCI.2016.2601296","volume":"2","author":"KH Jin","year":"2016","unstructured":"Jin, K. H., Lee, D. & Ye, J. C. A general framework for compressed sensing and parallel MRI using annihilating filter based low-rank hankel matrix. IEEE Trans. Comput. Imag. 2, 480\u2013495, https:\/\/doi.org\/10.1109\/TCI.2016.2601296 (2016).","journal-title":"IEEE Trans. Comput. Imag."},{"key":"39888_CR19","doi-asserted-by":"publisher","first-page":"1848","DOI":"10.1002\/mrm.26081","volume":"76","author":"D Lee","year":"2016","unstructured":"Lee, D., Jin, K. H., Kim, E. Y., Park, S.-H. & Ye, J. C. Acceleration of MR parameter mapping using annihilating filter-based low rank hankel matrix (ALOHA). Magn. Reson. Med. 76, 1848\u20131864, https:\/\/doi.org\/10.1002\/mrm.26081 (2016).","journal-title":"Magn. Reson. Med."},{"key":"39888_CR20","doi-asserted-by":"publisher","first-page":"535","DOI":"10.1109\/TCI.2017.2721819","volume":"3","author":"G Ongie","year":"2017","unstructured":"Ongie, G. & Jacob, M. A Fast Algorithm for Convolutional Structured Low-Rank Matrix Recovery. IEEE Trans. Comput. Imag. 3, 535\u2013550, https:\/\/doi.org\/10.1109\/TCI.2017.2721819 (2017).","journal-title":"IEEE Trans. Comput. Imag."},{"key":"39888_CR21","doi-asserted-by":"publisher","first-page":"1004","DOI":"10.1137\/15M1042280","volume":"9","author":"G Ongie","year":"2016","unstructured":"Ongie, G. & Jacob, M. Off-the-Grid Recovery of Piecewise Constant Images from Few Fourier Samples. SIAM J. Imag. Sci. 9, 1004\u20131041, https:\/\/doi.org\/10.1137\/15M1042280 (2016).","journal-title":"SIAM J. Imag. Sci."},{"key":"39888_CR22","unstructured":"Uecker, M., Block, K. T. & Frahm, J. Nonlinear Inversion with L1-Wavelet Regularization \u2013 Application to Autocalibrated Parallel Imaging. In Proc. Intl. Soc. Mag. Reson. Med., 16, 1479 (Toronto, 2008)."},{"key":"39888_CR23","doi-asserted-by":"publisher","first-page":"1132","DOI":"10.1109\/TMI.2013.2255133","volume":"32","author":"SG Lingala","year":"2013","unstructured":"Lingala, S. G. & Jacob, M. Blind compressive sensing dynamic MRI. IEEE Trans. Med. Imag. 32, 1132\u20131145, https:\/\/doi.org\/10.1109\/TMI.2013.2255133 (2013).","journal-title":"Imag."},{"key":"39888_CR24","doi-asserted-by":"publisher","unstructured":"Haldar, J. P. & Liang, Z. P. Spatiotemporal imaging with partially separable functions: A matrix recovery approach. In Proc. IEEE Int. Symp. Biomed. Imaging, 716\u2013719, https:\/\/doi.org\/10.1109\/ISBI.2010.5490076 (Rotterdam, 2010).","DOI":"10.1109\/ISBI.2010.5490076"},{"key":"39888_CR25","unstructured":"Uecker, M. & Lustig, M. Making SENSE of Chemical Shift: Separating Species in Single-Shot EPI using Multiple Coils. In Proc. Intl. Soc. Mag. Reson. Med., 20, 2490 (Melbourne, 2012)."},{"key":"39888_CR26","doi-asserted-by":"publisher","first-page":"978","DOI":"10.1002\/mrm.25473","volume":"74","author":"PJ Shin","year":"2015","unstructured":"Shin, P. J. et al. Chemical Shift Separation with Controlled Aliasing for Hyperpolarized 13 C Metabolic Imaging. Magn. Reson. Med. 74, 978\u2013989 (2015).","journal-title":"Magn. Reson. Med."},{"key":"39888_CR27","unstructured":"Inati, S. J., Hansen, M. S. & Kellman, P. A solution to the phase problem in adaptive coil combination. In Proc. Intl. Soc. Mag. Reson. Med., 21, 2627 (Salt Lake City, 2013)."},{"key":"39888_CR28","unstructured":"Bilgic, B., Marques, J. P., Wald, L. L. & Setsompop, K. Block coil compression for virtual body coil without phase singularities. In Fourth International Workshop on MRI Phase Contrast & Quantitative Susceptibility Mapping (Graz, 2016)."},{"key":"39888_CR29","doi-asserted-by":"publisher","first-page":"682","DOI":"10.1002\/(SICI)1522-2594(200005)43:5<682::AID-MRM10>3.0.CO;2-G","volume":"43","author":"DO Walsh","year":"2000","unstructured":"Walsh, D. O., Gmitro, A. F. & Marcellin, M. W. Adaptive reconstruction of phased array MR imagery. Magn. Reson. Med. 43, 682\u2013690 (2000).","journal-title":"Magn. Reson. Med."},{"key":"39888_CR30","unstructured":"Uecker, M. & Lustig, M. Memory-Saving Iterative Reconstruction on Overlapping Blocks of K-Space. In Proc. Intl. Soc. Mag. Reson. Med., 21, 2645 (Salt Lake City, 2013)."},{"key":"39888_CR31","doi-asserted-by":"publisher","first-page":"1695","DOI":"10.1002\/jmri.24728","volume":"41","author":"N Li","year":"2015","unstructured":"Li, N., Wang, W.-T., Pham, D. L. & Butman, J. A. Artifactual microhemorrhage generated by susceptibility weighted image processing. J. Magn. Reson. Imaging 41, 1695\u20131700, https:\/\/doi.org\/10.1002\/jmri.24728 (2015).","journal-title":"J. Magn. Reson. Imaging"},{"key":"39888_CR32","doi-asserted-by":"publisher","first-page":"730","DOI":"10.1002\/mrm.26726","volume":"79","author":"X Wang","year":"2018","unstructured":"Wang, X. et al. Model-based T1 mapping with sparsity constraints using single-shot inversion-recovery radial FLASH. Magn. Reson. Med. 79, 730\u2013740, https:\/\/doi.org\/10.1002\/mrm.26726 (2018).","journal-title":"Magn. Reson. Med."},{"key":"39888_CR33","unstructured":"Uecker, M. et al. Berkeley advanced reconstruction toolbox. In Proc. Intl. Soc. Mag. Reson. Med., 23, 2486 (Toronto, 2015)."},{"key":"39888_CR34","doi-asserted-by":"publisher","first-page":"42","DOI":"10.5281\/zenodo.16303","volume":"36","author":"O Tange","year":"2011","unstructured":"Tange, O. GNU Parallel - The Command-Line Power Tool. login: The USENIX Mag. 36, 42\u201347, https:\/\/doi.org\/10.5281\/zenodo.16303 (2011).","journal-title":"login: The USENIX Mag."},{"key":"39888_CR35","doi-asserted-by":"publisher","first-page":"187","DOI":"10.1016\/j.jmr.2005.06.004","volume":"176","author":"JD Willig-Onwuachi","year":"2005","unstructured":"Willig-Onwuachi, J. D. et al. Phase-constrained parallel MR image reconstruction. J Magn Reson. 176, 187\u2013198 (2005).","journal-title":"J Magn Reson."},{"key":"39888_CR36","doi-asserted-by":"publisher","first-page":"93","DOI":"10.1002\/mrm.21652","volume":"61","author":"M Blaimer","year":"2009","unstructured":"Blaimer, M. et al. Virtual coil concept for improved parallel MRI employing conjugate symmetric signals. Magn. Reson. Med. 61, 93\u2013102 (2009).","journal-title":"Magn. Reson. Med."},{"key":"39888_CR37","doi-asserted-by":"publisher","first-page":"1086","DOI":"10.1002\/mrm.25685","volume":"75","author":"M Blaimer","year":"2016","unstructured":"Blaimer, M. et al. Comparison of phase-constrained parallel MRI approaches: Analogies and differences. Magn. Reson. Med. 75, 1086\u20131099 (2016).","journal-title":"Magn. Reson. Med."},{"key":"39888_CR38","doi-asserted-by":"publisher","first-page":"1456","DOI":"10.1002\/mrm.22453","volume":"63","author":"M Uecker","year":"2010","unstructured":"Uecker, M., Zhang, S. & Frahm, J. Nonlinear inverse reconstruction for real-time MRI of the human heart using undersampled radial FLASH. Magn. Reson. Med. 63, 1456\u20131462, https:\/\/doi.org\/10.1002\/mrm.22453 (2010).","journal-title":"Magn. Reson. Med."},{"key":"39888_CR39","doi-asserted-by":"publisher","first-page":"308","DOI":"10.1002\/mrm.24643","volume":"71","author":"A Moussavi","year":"2013","unstructured":"Moussavi, A., Untenberger, M., Uecker, M. & Frahm, J. Correction of gradient-induced phase errors in radial MRI. Magn. Reson. Med. 71, 308\u2013312, https:\/\/doi.org\/10.1002\/mrm.24643 (2013).","journal-title":"Magn. Reson. Med."},{"key":"39888_CR40","doi-asserted-by":"crossref","unstructured":"Vasanawala, S. et al. Practical parallel imaging compressed sensing MRI: Summary of two years of experience in accelerating body MRI of pediatric patients. In Proc. IEEE Int. Symp. Biomed. Imaging, 1039\u20131043 (IEEE, Chicago, 2011).","DOI":"10.1109\/ISBI.2011.5872579"},{"key":"39888_CR41","doi-asserted-by":"publisher","first-page":"823","DOI":"10.1002\/mrm.1910030602","volume":"3","author":"J Hennig","year":"1986","unstructured":"Hennig, J., Nauerth, A. & Friedburg, H. RARE imaging: a fast imaging method for clinical MR. Magn. Reson. Med. 3, 823\u2013833 (1986).","journal-title":"Magn. Reson. Med."},{"key":"39888_CR42","unstructured":"Ong, F., Amin, S., Vasanawala, S. & Lustig, M. Mridata.org: An open archive for sharing MRI raw data. In Proc. Intl. Soc. Mag. Reson. Med., 26 (Paris, 2018)."},{"key":"39888_CR43","doi-asserted-by":"publisher","first-page":"549","DOI":"10.1002\/mrm.20787","volume":"55","author":"FA Breuer","year":"2006","unstructured":"Breuer, F. A. et al. Controlled aliasing in volumetric parallel imaging (2D CAIPIRINHA). Magn. Reson. Med. 55, 549\u2013556, https:\/\/doi.org\/10.1002\/mrm.20787 (2006).","journal-title":"Magn. Reson. Med."},{"key":"39888_CR44","unstructured":"Kovesi, P. Good Colour Maps: How to Design Them. arXiv Preprint at https:\/\/arxiv.org\/abs\/1509.03700 (2015)."}],"container-title":["Scientific Reports"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.nature.com\/articles\/s41598-019-39888-7.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.nature.com\/articles\/s41598-019-39888-7","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.nature.com\/articles\/s41598-019-39888-7.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2022,12,17]],"date-time":"2022-12-17T06:44:22Z","timestamp":1671259462000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.nature.com\/articles\/s41598-019-39888-7"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2019,2,28]]},"references-count":44,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2019,12]]}},"alternative-id":["39888"],"URL":"https:\/\/doi.org\/10.1038\/s41598-019-39888-7","relation":{},"ISSN":["2045-2322"],"issn-type":[{"value":"2045-2322","type":"electronic"}],"subject":[],"published":{"date-parts":[[2019,2,28]]},"assertion":[{"value":"13 July 2018","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"4 February 2019","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"28 February 2019","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"The authors declare no competing interests.","order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing Interests"}}],"article-number":"3034"}}