{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,2,19]],"date-time":"2026-02-19T22:40:21Z","timestamp":1771540821836,"version":"3.50.1"},"reference-count":25,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2019,3,5]],"date-time":"2019-03-05T00:00:00Z","timestamp":1551744000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2019,3,5]],"date-time":"2019-03-05T00:00:00Z","timestamp":1551744000000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Sci Rep"],"abstract":"<jats:title>Abstract<\/jats:title><jats:p>Retinal ganglion cells are distributed disproportionately with retinal eccentricity. Pattern electroretinogram (PERG) stimuli resulted in reduced responses with more eccentric stimuli. Therefore, we investigated whether PERG amplitude is associated with the location of visual field (VF) defect in primary open-angle glaucoma. Data from Twenty-nine glaucoma patients with a parafoveal scotoma (PFS) within the central 10\u00b0 of fixation, 23 glaucoma patients with a peripheral nasal step (PNS), and 27 normal control subjects were analyzed in this study. Electroretinograms (ERGs) were obtained using a commercial ERG stimulator (Neuro-ERG). The thickness of the ganglion cell-inner plexiform layer (GCIPL) was measured using spectral-domain optical coherence tomography. A lower N95 amplitude was observed in both PFS and PNS compared to the normal control (Both P\u2009&lt;\u20090.001). The N95 amplitude of the PFS group was significantly lower than that of the PNS group (P\u2009=\u20090.034). Average GCIPL thickness correlated positively with N95 amplitude (r\u2009=\u20090.368, P\u2009=\u20090.002), but did not correlate significantly with global mean sensitivity (r\u2009=\u20090.228, P\u2009=\u20090.073) or mean deviation on 24-2 standard automated perimetry (r\u2009=\u20090.173, P\u2009=\u20090.176). In conclusion, parafoveal VF defects were associated with the lower PERG amplitude. Therefore, it is necessary to take into account the location of VF defects in evaluating PERGs of glaucoma patients.<\/jats:p>","DOI":"10.1038\/s41598-019-39948-y","type":"journal-article","created":{"date-parts":[[2019,3,5]],"date-time":"2019-03-05T11:05:48Z","timestamp":1551783948000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":4,"title":["Comparison of pattern electroretinograms of glaucoma patients with parafoveal scotoma versus peripheral nasal step"],"prefix":"10.1038","volume":"9","author":[{"given":"Kyoung In","family":"Jung","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-3284-4756","authenticated-orcid":false,"given":"Sooji","family":"Jeon","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Yong Chan","family":"Kim","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Chan Kee","family":"Park","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2019,3,5]]},"reference":[{"key":"39948_CR1","doi-asserted-by":"publisher","first-page":"S71","DOI":"10.1016\/j.ophtha.2017.04.009","volume":"124","author":"AS Camp","year":"2017","unstructured":"Camp, A. S. & Weinreb, R. N. Will Perimetry Be Performed to Monitor Glaucoma in 2025? Ophthalmology 124, S71\u2013S75 (2017).","journal-title":"Ophthalmology"},{"key":"39948_CR2","doi-asserted-by":"publisher","first-page":"488","DOI":"10.1016\/j.ajo.2009.09.027","volume":"149","author":"A Tafreshi","year":"2010","unstructured":"Tafreshi, A. et al. Pattern electroretinogram and psychophysical tests of visual function for discriminating between healthy and glaucoma eyes. Am J Ophthalmol 149, 488\u2013495 (2010).","journal-title":"Am J Ophthalmol"},{"key":"39948_CR3","doi-asserted-by":"publisher","first-page":"287","DOI":"10.1007\/s00441-013-1598-6","volume":"353","author":"M Bach","year":"2013","unstructured":"Bach, M. & Poloschek, C. M. Electrophysiology and glaucoma: current status and future challenges. Cell Tissue Res 353, 287\u2013296 (2013).","journal-title":"Cell Tissue Res"},{"key":"39948_CR4","doi-asserted-by":"publisher","first-page":"386","DOI":"10.1097\/OPX.0b013e318177ebf3","volume":"85","author":"M Bach","year":"2008","unstructured":"Bach, M. & Hoffmann, M. B. Update on the pattern electroretinogram in glaucoma. Optom Vis Sci 85, 386\u2013395 (2008).","journal-title":"Optom Vis Sci"},{"key":"39948_CR5","doi-asserted-by":"publisher","first-page":"1182","DOI":"10.1167\/iovs.12-11201","volume":"54","author":"D Preiser","year":"2013","unstructured":"Preiser, D., Lagreze, W. A., Bach, M. & Poloschek, C. M. Photopic negative response versus pattern electroretinogram in early glaucoma. Invest Ophthalmol Vis Sci 54, 1182\u20131191 (2013).","journal-title":"Invest Ophthalmol Vis Sci"},{"key":"39948_CR6","doi-asserted-by":"publisher","first-page":"437","DOI":"10.1016\/j.ophtha.2008.10.026","volume":"116","author":"C Bowd","year":"2009","unstructured":"Bowd, C. et al. Diagnostic accuracy of pattern electroretinogram optimized for glaucoma detection. Ophthalmology 116, 437\u2013443 (2009).","journal-title":"Ophthalmology"},{"key":"39948_CR7","first-page":"1710","volume":"34","author":"N Pfeiffer","year":"1993","unstructured":"Pfeiffer, N., Tillmon, B. & Bach, M. Predictive value of the pattern electroretinogram in high-risk ocular hypertension. Invest Ophthalmol Vis Sci 34, 1710\u20131715 (1993).","journal-title":"Invest Ophthalmol Vis Sci"},{"key":"39948_CR8","doi-asserted-by":"publisher","first-page":"1098","DOI":"10.1016\/S0161-6420(87)33318-4","volume":"94","author":"P Wanger","year":"1987","unstructured":"Wanger, P. & Persson, H. E. Pattern-reversal electroretinograms and high-pass resolution perimetry in suspected or early glaucoma. Ophthalmology 94, 1098\u20131103 (1987).","journal-title":"Ophthalmology"},{"key":"39948_CR9","doi-asserted-by":"publisher","first-page":"e0178004","DOI":"10.1371\/journal.pone.0178004","volume":"12","author":"K Park","year":"2017","unstructured":"Park, K., Kim, J. & Lee, J. Measurement of macular structure-function relationships using spectral domain-optical coherence tomography (SD-OCT) and pattern electroretinograms (PERG). PLoS One 12, e0178004 (2017).","journal-title":"PLoS One"},{"key":"39948_CR10","doi-asserted-by":"publisher","first-page":"8571","DOI":"10.1167\/iovs.11-8376","volume":"52","author":"X Luo","year":"2011","unstructured":"Luo, X. & Frishman, L. J. Retinal pathway origins of the pattern electroretinogram (PERG). Invest Ophthalmol Vis Sci 52, 8571\u20138584 (2011).","journal-title":"Invest Ophthalmol Vis Sci"},{"key":"39948_CR11","first-page":"2068","volume":"33","author":"PA Sample","year":"1992","unstructured":"Sample, P. A. & Weinreb, R. N. Progressive color visual field loss in glaucoma. Invest Ophthalmol Vis Sci 33, 2068\u20132071 (1992).","journal-title":"Invest Ophthalmol Vis Sci"},{"key":"39948_CR12","doi-asserted-by":"publisher","first-page":"1546","DOI":"10.1016\/j.ophtha.2013.01.045","volume":"120","author":"SC Park","year":"2013","unstructured":"Park, S. C. et al. Parafoveal scotoma progression in glaucoma: Humphrey 10-2 versus 24-2 visual field analysis. Ophthalmology 120, 1546\u20131550 (2013).","journal-title":"Ophthalmology"},{"key":"39948_CR13","doi-asserted-by":"publisher","first-page":"3","DOI":"10.1167\/tvst.1.1.3","volume":"1","author":"DC Hood","year":"2012","unstructured":"Hood, D. C. et al. The Nature of Macular Damage in Glaucoma as Revealed by Averaging Optical Coherence Tomography Data. Transl Vis Sci Technol 1, 3 (2012).","journal-title":"Transl Vis Sci Technol"},{"key":"39948_CR14","doi-asserted-by":"publisher","first-page":"939","DOI":"10.1152\/jn.1984.51.5.939","volume":"51","author":"RF Hess","year":"1984","unstructured":"Hess, R. F. & Baker, C. L. Jr. Human pattern-evoked electroretinogram. J Neurophysiol 51, 939\u2013951 (1984).","journal-title":"J Neurophysiol"},{"key":"39948_CR15","doi-asserted-by":"publisher","first-page":"8323","DOI":"10.1167\/iovs.11-7962","volume":"52","author":"JC Mwanza","year":"2011","unstructured":"Mwanza, J. C. et al. Macular ganglion cell-inner plexiform layer: automated detection and thickness reproducibility with spectral domain-optical coherence tomography in glaucoma. Invest Ophthalmol Vis Sci 52, 8323\u20138329 (2011).","journal-title":"Invest Ophthalmol Vis Sci"},{"key":"39948_CR16","doi-asserted-by":"publisher","first-page":"7344","DOI":"10.1167\/iovs.13-12667","volume":"54","author":"HY Shin","year":"2013","unstructured":"Shin, H. Y., Park, H. Y., Jung, K. I. & Park, C. K. Comparative study of macular ganglion cell-inner plexiform layer and peripapillary retinal nerve fiber layer measurement: structure-function analysis. Invest Ophthalmol Vis Sci 54, 7344\u20137353 (2013).","journal-title":"Invest Ophthalmol Vis Sci"},{"key":"39948_CR17","unstructured":"JL., F. The design and Analysis of Clinical Experiments. 1\u201332 (Wiley, 1986)."},{"key":"39948_CR18","doi-asserted-by":"publisher","first-page":"1153","DOI":"10.1007\/s00417-008-0808-5","volume":"246","author":"B Falsini","year":"2008","unstructured":"Falsini, B. et al. Structure-function relationship in ocular hypertension and glaucoma: interindividual and interocular analysis by OCT and pattern ERG. Graefes Arch Clin Exp Ophthalmol 246, 1153\u20131162 (2008).","journal-title":"Graefes Arch Clin Exp Ophthalmol"},{"key":"39948_CR19","doi-asserted-by":"publisher","first-page":"905","DOI":"10.1016\/S0161-6420(00)00644-8","volume":"108","author":"V Parisi","year":"2001","unstructured":"Parisi, V. et al. Correlation between optical coherence tomography, pattern electroretinogram, and visual evoked potentials in open-angle glaucoma patients. Ophthalmology 108, 905\u2013912 (2001).","journal-title":"Ophthalmology"},{"key":"39948_CR20","doi-asserted-by":"publisher","first-page":"3904","DOI":"10.1167\/iovs.06-0161","volume":"47","author":"LM Ventura","year":"2006","unstructured":"Ventura, L. M., Sorokac, N., De Los Santos, R., Feuer, W. J. & Porciatti, V. The relationship between retinal ganglion cell function and retinal nerve fiber thickness in early glaucoma. Invest Ophthalmol Vis Sci 47, 3904\u20133911 (2006).","journal-title":"Invest Ophthalmol Vis Sci"},{"key":"39948_CR21","doi-asserted-by":"publisher","first-page":"48","DOI":"10.1016\/j.exer.2018.01.021","volume":"169","author":"M Bach","year":"2018","unstructured":"Bach, M., Cuno, A. K. & Hoffmann, M. B. Retinal conduction speed analysis reveals different origins of the P50 and N95 components of the (multifocal) pattern electroretinogram. Exp Eye Res 169, 48\u201353 (2018).","journal-title":"Exp Eye Res"},{"key":"39948_CR22","doi-asserted-by":"publisher","first-page":"957","DOI":"10.1016\/j.ophtha.2007.08.023","volume":"115","author":"MJ Fredette","year":"2008","unstructured":"Fredette, M. J., Anderson, D. R., Porciatti, V. & Feuer, W. Reproducibility of pattern electroretinogram in glaucoma patients with a range of severity of disease with the new glaucoma paradigm. Ophthalmology 115, 957\u2013963 (2008).","journal-title":"Ophthalmology"},{"key":"39948_CR23","doi-asserted-by":"publisher","first-page":"437","DOI":"10.1097\/IJG.0b013e31818c6f44","volume":"18","author":"C Bowd","year":"2009","unstructured":"Bowd, C. et al. Repeatability of pattern electroretinogram measurements using a new paradigm optimized for glaucoma detection. J Glaucoma 18, 437\u2013442 (2009).","journal-title":"J Glaucoma"},{"key":"39948_CR24","doi-asserted-by":"publisher","first-page":"161","DOI":"10.1016\/j.ophtha.2003.04.007","volume":"111","author":"V Porciatti","year":"2004","unstructured":"Porciatti, V. & Ventura, L. M. Normative data for a user-friendly paradigm for pattern electroretinogram recording. Ophthalmology 111, 161\u2013168 (2004).","journal-title":"Ophthalmology"},{"key":"39948_CR25","doi-asserted-by":"publisher","first-page":"227","DOI":"10.1007\/s10633-013-9412-z","volume":"127","author":"M Bach","year":"2013","unstructured":"Bach, M. & Ramharter-Sereinig, A. Pattern electroretinogram to detect glaucoma: comparing the PERGLA and the PERG Ratio protocols. Doc Ophthalmol 127, 227\u2013238 (2013).","journal-title":"Doc Ophthalmol"}],"container-title":["Scientific Reports"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.nature.com\/articles\/s41598-019-39948-y.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.nature.com\/articles\/s41598-019-39948-y","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.nature.com\/articles\/s41598-019-39948-y.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2022,12,17]],"date-time":"2022-12-17T07:13:46Z","timestamp":1671261226000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.nature.com\/articles\/s41598-019-39948-y"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2019,3,5]]},"references-count":25,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2019,12]]}},"alternative-id":["39948"],"URL":"https:\/\/doi.org\/10.1038\/s41598-019-39948-y","relation":{},"ISSN":["2045-2322"],"issn-type":[{"value":"2045-2322","type":"electronic"}],"subject":[],"published":{"date-parts":[[2019,3,5]]},"assertion":[{"value":"11 July 2018","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"1 February 2019","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"5 March 2019","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"The authors declare no competing interests.","order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing Interests"}}],"article-number":"3547"}}