{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,11,3]],"date-time":"2026-11-03T17:18:42Z","timestamp":1793726322024,"version":"4.6.1"},"reference-count":19,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2019,2,28]],"date-time":"2019-02-28T00:00:00Z","timestamp":1551312000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2019,2,28]],"date-time":"2019-02-28T00:00:00Z","timestamp":1551312000000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"funder":[{"name":"National Key Research and Development Plan of China"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Sci Rep"],"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:p>The accuracy of robot-assisted pedicle screw placement is unstable and remains controversial. The purpose of this study was to determine the risk factors for unsatisfactory Renaissance robot-assisted pedicle screw placement. This was a retrospective study of prospective data. From January 2017 to March 2018, 136 robot-assisted pedicle screw placements were performed in our department for spinal diseases, and a total of 874 screws were evaluated. All screws were assessed by the Gertzbein and Robbins classification. A and B were defined as satisfactory. C, D, and E were defined as unsatisfactory. Intraoperative registration failures due to nontechnical reasons or intraoperative adjustment were also defined as unsatisfactory. According to the evaluated results, the screws were divided into the satisfactory group (Group A) and the unsatisfactory group (Group B). The satisfactory rate was defined as satisfactory screws (the screws in Group A)\/total screws, and the accurate rate was defined as accuracy screws (the screws in Group A)\/the screws implanted by the robot (total screws - failed registration screws - screws adjusted during the operation). The age, sex, BMI, and BMD as well as the type of disease, the degree of vertebral rotation and the type of screw placement (percutaneous implantation or open implantation) were compared between the two groups, with the assessment of potential risk factors for unsatisfactory robot-assisted screw placement using logistic regression. A total of 874 screws were evaluated; there were 759 screws in Group A and 115 screws in Group B. The satisfactory rate was 86.8% (759\/874), and the accuracy rate of the robot-placed screws was 94.4% (759\/804). After logistic regression analysis, the independent risk factors were identified as obesity (OR 5.357 [95% CI 2.897\u20139.906], p\u2009&lt;\u20090.01), osteoporosis, vertebral rotation and the presence of congenital scoliosis (OR 9.835 [95% CI 4.279\u201322.604], p\u2009&lt;\u20090.01), particularly for severe osteoporosis (T\u2009&lt;\u2009\u22123.5) and severe vertebral rotation (III-IV). According to the results of this study, obesity, osteoporosis and congenital scoliosis are risk factors for unsatisfactory robot-assisted screw placement. Furthermore, for surgeons in the initial stage of using a robot, we suggest avoiding cases in which a single risk factor or multiple risk factors exist to ensure the safety of the operation and to help augment the confidence of the surgeons.<\/jats:p>","DOI":"10.1038\/s41598-019-40057-z","type":"journal-article","created":{"date-parts":[[2019,2,28]],"date-time":"2019-02-28T06:05:03Z","timestamp":1551333903000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":57,"title":["Risk factors for robot-assisted spinal pedicle screw malposition"],"prefix":"10.1038","volume":"9","author":[{"given":"Jia Nan","family":"Zhang","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yong","family":"Fan","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ding Jun","family":"Hao","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2019,2,28]]},"reference":[{"key":"40057_CR1","doi-asserted-by":"publisher","first-page":"1519","DOI":"10.2106\/00004623-199911000-00003","volume":"81","author":"JE Lonstein","year":"1999","unstructured":"Lonstein, J. E. et al. Complications associated with pedicle screws. J. Bone Joint Surg. Am. 81, 1519\u20131528 (1999).","journal-title":"J. Bone Joint Surg. Am."},{"key":"40057_CR2","doi-asserted-by":"publisher","first-page":"392","DOI":"10.1097\/BRS.0b013e318191ed32","volume":"34","author":"I Pechlivanis","year":"2009","unstructured":"Pechlivanis, I. et al. Percutaneous placement of pedicle screws in the lumbar spine using a bone mounted miniature robotic system: first experiences and accuracy of screw placement. Spine 34, 392\u2013398, https:\/\/doi.org\/10.1097\/BRS.0b013e318191ed32 (2009).","journal-title":"Spine"},{"key":"40057_CR3","doi-asserted-by":"publisher","first-page":"2109","DOI":"10.1097\/BRS.0b013e3181d323ab","volume":"35","author":"DP Devito","year":"2010","unstructured":"Devito, D. P. et al. Clinical acceptance and accuracy assessment of spinal implants guided with SpineAssist surgical robot: retrospective study. Spine 35, 2109\u20132115, https:\/\/doi.org\/10.1097\/BRS.0b013e3181d323ab (2010).","journal-title":"Spine"},{"key":"40057_CR4","doi-asserted-by":"publisher","first-page":"291","DOI":"10.1007\/s00586-013-2879-1","volume":"23","author":"HJ Marcus","year":"2014","unstructured":"Marcus, H. J., Cundy, T. P., Nandi, D., Yang, G. Z. & Darzi, A. Robot-assisted and fluoroscopy-guided pedicle screw placement: a systematic review. Eur. Spine J. 23, 291\u2013297, https:\/\/doi.org\/10.1007\/s00586-013-2879-1 (2014).","journal-title":"Eur. Spine J."},{"key":"40057_CR5","doi-asserted-by":"publisher","first-page":"353","DOI":"10.1097\/brs.0000000000001778","volume":"42","author":"SJ Hyun","year":"2017","unstructured":"Hyun, S. J., Kim, K. J., Jahng, T. A. & Kim, H. J. Minimally Invasive Robotic Versus Open Fluoroscopic-guided Spinal Instrumented Fusions: A Randomized Controlled Trial. Spine 42, 353\u2013358, https:\/\/doi.org\/10.1097\/brs.0000000000001778 (2017).","journal-title":"Spine"},{"key":"40057_CR6","doi-asserted-by":"publisher","first-page":"E496","DOI":"10.1097\/BRS.0b013e31824b7767","volume":"37","author":"F Ringel","year":"2012","unstructured":"Ringel, F. et al. Accuracy of robot-assisted placement of lumbar and sacral pedicle screws: a prospective randomized comparison to conventional freehand screw implantation. Spine 37, E496\u2013501, https:\/\/doi.org\/10.1097\/BRS.0b013e31824b7767 (2012).","journal-title":"Spine"},{"key":"40057_CR7","doi-asserted-by":"publisher","first-page":"153","DOI":"10.1097\/brs.0000000000000100","volume":"39","author":"Y Barzilay","year":"2014","unstructured":"Barzilay, Y. et al. Robot-assisted vertebral body augmentation: a radiation reduction tool. Spine 39, 153\u2013157, https:\/\/doi.org\/10.1097\/brs.0000000000000100 (2014).","journal-title":"Spine"},{"key":"40057_CR8","doi-asserted-by":"publisher","first-page":"11","DOI":"10.1097\/00007632-199001000-00004","volume":"15","author":"SD Gertzbein","year":"1990","unstructured":"Gertzbein, S. D. & Robbins, S. E. Accuracy of pedicular screw placement in vivo. Spine 15, 11\u201314 (1990).","journal-title":"Spine"},{"key":"40057_CR9","doi-asserted-by":"publisher","first-page":"17","DOI":"10.1007\/s11701-016-0597-5","volume":"11","author":"N Keric","year":"2017","unstructured":"Keric, N. et al. Evaluation of surgical strategy of conventional vs. percutaneous robot-assisted spinal trans-pedicular instrumentation in spondylodiscitis. J. Robot. Surg. 11, 17\u201325, https:\/\/doi.org\/10.1007\/s11701-016-0597-5 (2017).","journal-title":"J. Robot. Surg."},{"key":"40057_CR10","doi-asserted-by":"publisher","first-page":"636","DOI":"10.3171\/2014.3.spine13714","volume":"20","author":"B Schatlo","year":"2014","unstructured":"Schatlo, B. et al. Safety and accuracy of robot-assisted versus fluoroscopy-guided pedicle screw insertion for degenerative diseases of the lumbar spine: a matched cohort comparison. J. Neurosurg. Spine 20, 636\u2013643, https:\/\/doi.org\/10.3171\/2014.3.spine13714 (2014).","journal-title":"J. Neurosurg. Spine"},{"key":"40057_CR11","doi-asserted-by":"publisher","first-page":"1839","DOI":"10.1007\/s11999-013-3291-1","volume":"472","author":"X Hu","year":"2014","unstructured":"Hu, X. & Lieberman, I. H. What is the learning curve for robotic-assisted pedicle screw placement in spine surgery? Clin. Orthop. Relat. Res. 472, 1839\u20131844, https:\/\/doi.org\/10.1007\/s11999-013-3291-1 (2014).","journal-title":"Clin. Orthop. Relat. Res."},{"key":"40057_CR12","doi-asserted-by":"publisher","first-page":"E986","DOI":"10.1097\/brs.0000000000000960","volume":"40","author":"JD van Dijk","year":"2015","unstructured":"van Dijk, J. D., van den Ende, R. P., Stramigioli, S., Kochling, M. & Hoss, N. Clinical pedicle screw accuracy and deviation from planning in robot-guided spine surgery: robot-guided pedicle screw accuracy. Spine 40, E986\u2013991, https:\/\/doi.org\/10.1097\/brs.0000000000000960 (2015).","journal-title":"Spine"},{"key":"40057_CR13","doi-asserted-by":"publisher","first-page":"E183","DOI":"10.1097\/BSD.0b013e31828054c8","volume":"26","author":"MH Lee","year":"2013","unstructured":"Lee, M. H. et al. Feasibility of Intra-operative Computed Tomography Navigation System for Pedicle Screw Insertion of the Thoraco-lumbar Spine. Journal of spinal disorders & techniques 26, E183\u2013e187, https:\/\/doi.org\/10.1097\/BSD.0b013e31828054c8 (2013).","journal-title":"Journal of spinal disorders & techniques"},{"key":"40057_CR14","doi-asserted-by":"publisher","first-page":"e86346","DOI":"10.1371\/journal.pone.0086346","volume":"9","author":"W Tian","year":"2014","unstructured":"Tian, W. et al. A robot-assisted surgical system using a force-image control method for pedicle screw insertion. Plos One 9, e86346 (2014).","journal-title":"Plos One"},{"key":"40057_CR15","doi-asserted-by":"publisher","first-page":"12","DOI":"10.1227\/NEU.0b013e318270d02c","volume":"72","author":"F Roser","year":"2013","unstructured":"Roser, F., Tatagiba, M. & Maier, G. Spinal robotics: current applications and future perspectives. Neurosurgery 72, 12\u201318 (2013).","journal-title":"Neurosurgery"},{"key":"40057_CR16","doi-asserted-by":"publisher","unstructured":"Kim, H. J. et al. A prospective, randomized, controlled trial of robot-assisted vs freehand pedicle screw fixation in spine surgery. Int. J. Med. Robot. 13, https:\/\/doi.org\/10.1002\/rcs.1779 (2017).","DOI":"10.1002\/rcs.1779"},{"key":"40057_CR17","doi-asserted-by":"publisher","first-page":"e5835","DOI":"10.1097\/md.0000000000005835","volume":"96","author":"TH Tsai","year":"2017","unstructured":"Tsai, T. H. et al. Pedicle screw placement accuracy of bone-mounted miniature robot system. Medicine (Baltimore) 96, e5835, https:\/\/doi.org\/10.1097\/md.0000000000005835 (2017).","journal-title":"Medicine (Baltimore)"},{"key":"40057_CR18","doi-asserted-by":"publisher","first-page":"E14","DOI":"10.3171\/2017.3.focus179","volume":"42","author":"G Molliqaj","year":"2017","unstructured":"Molliqaj, G. et al. Accuracy of robot-guided versus freehand fluoroscopy-assisted pedicle screw insertion in thoracolumbar spinal surgery. Neurosurg. Focus 42, E14, https:\/\/doi.org\/10.3171\/2017.3.focus179 (2017).","journal-title":"Neurosurg. Focus"},{"key":"40057_CR19","doi-asserted-by":"publisher","first-page":"661","DOI":"10.1007\/s00586-012-2499-1","volume":"22","author":"X Hu","year":"2013","unstructured":"Hu, X., Ohnmeiss, D. D. & Lieberman, I. H. Robotic-assisted pedicle screw placement: lessons learned from the first 102 patients. Eur. Spine J. 22, 661\u2013666, https:\/\/doi.org\/10.1007\/s00586-012-2499-1 (2013).","journal-title":"Eur. Spine J."}],"container-title":["Scientific Reports"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.nature.com\/articles\/s41598-019-40057-z.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.nature.com\/articles\/s41598-019-40057-z","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.nature.com\/articles\/s41598-019-40057-z.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2022,12,17]],"date-time":"2022-12-17T01:42:50Z","timestamp":1671241370000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.nature.com\/articles\/s41598-019-40057-z"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2019,2,28]]},"references-count":19,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2019,12]]}},"alternative-id":["40057"],"URL":"https:\/\/doi.org\/10.1038\/s41598-019-40057-z","relation":{},"ISSN":["2045-2322"],"issn-type":[{"value":"2045-2322","type":"electronic"}],"subject":[],"published":{"date-parts":[[2019,2,28]]},"assertion":[{"value":"24 May 2018","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"4 February 2019","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"28 February 2019","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"We wish to confirm that there are no known conflicts of interest associated with this publication and there has been no significant financial support for this work that could have influenced its outcome. We confirm that the manuscript has been read and approved by all named authors and that there are no other persons who satisfied the criteria for authorship but are not listed. We further confirm that the order of authors listed in the manuscript has been approved by all of us. We confirm that we have given due consideration to the protection of intellectual property associated with this work and that there are no impediments to publication, including the timing of publication, with respect to intellectual property. In so doing we confirm that we have followed the regulations of our institutions concerning intellectual property. We understand that the Corresponding Author is the sole contact for the Editorial process (including Editorial Manager and direct communications with the office). He is responsible for communicating with the other authors about progress, submissions of revisions and final approval of proofs. We confirm that we have provided a current, correct email address which is accessible by the Corresponding Author and which has been configured to accept email from haodjspine@126.com.","order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing Interests"}}],"article-number":"3025"}}