{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,11,13]],"date-time":"2026-11-13T01:38:56Z","timestamp":1794533936059,"version":"4.9.1"},"reference-count":39,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2019,3,20]],"date-time":"2019-03-20T00:00:00Z","timestamp":1553040000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2019,3,20]],"date-time":"2019-03-20T00:00:00Z","timestamp":1553040000000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Sci Rep"],"abstract":"<jats:title>Abstract<\/jats:title><jats:p>We propose a noninvasive, self-diagnostic device that enables safe tear collection and glucose measurement. The device described herein was manufactured by tight assembly of a lid for tear collection in conjunction with a strip-type glucose sensor. The lid was designed to be in contact with the inferior palpebral conjunctiva for tear collection and was thus designed to possess a proper contact area and rounded boundaries to avoid eye tissue damage. For the strip-type glucose sensor, we employed a commercially available electrochemical sensor (Accu-Chek test strips), which was modified to reduce the volume of the reaction chamber (0.4\u2009\u03bcl) for a small amount of collected tear fluid. When tested with <jats:italic>in vivo<\/jats:italic> animal models, the device was able to collect tear fluid in a relatively short time (&lt;2\u2009s) without causing eye tissue damage, and the device allowed the collected tear fluid to be delivered to the sensor for measurement of tear glucose concentrations. The blood glucose concentrations estimated with the tear glucose concentrations obtained with the device exhibited a high correlation with those actually measured with a clinically available glucometer (R<jats:sup>2<\/jats:sup>\u2009=\u20090.9617).<\/jats:p>","DOI":"10.1038\/s41598-019-41066-8","type":"journal-article","created":{"date-parts":[[2019,3,20]],"date-time":"2019-03-20T11:03:45Z","timestamp":1553079825000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":36,"title":["Noninvasive Self-diagnostic Device for Tear Collection and Glucose Measurement"],"prefix":"10.1038","volume":"9","author":[{"given":"Seung Ho","family":"Lee","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yong Chan","family":"Cho","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Young","family":"Bin Choy","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2019,3,20]]},"reference":[{"key":"41066_CR1","doi-asserted-by":"publisher","first-page":"2339","DOI":"10.1056\/NEJMra0906948","volume":"363","author":"MI McCarthy","year":"2010","unstructured":"McCarthy, M. I. Genomic Medicine Genomics, Type 2 Diabetes, and Obesity. New Engl J Med 363, 2339\u20132350, https:\/\/doi.org\/10.1056\/NEJMra0906948 (2010).","journal-title":"New Engl J Med"},{"key":"41066_CR2","doi-asserted-by":"publisher","first-page":"41","DOI":"10.1038\/nature18642","volume":"536","author":"C Fuchsberger","year":"2016","unstructured":"Fuchsberger, C. et al. The genetic architecture of type 2 diabetes. Nature 536, 41\u201347, https:\/\/doi.org\/10.1038\/nature18642 (2016).","journal-title":"Nature"},{"key":"41066_CR3","doi-asserted-by":"crossref","unstructured":"Bartha, J. L., Martinez-Del-Fresno, P., Comino-Delgado, R. J. E. J. O. O., Gynecology & Biology, R. Early diagnosis of gestational diabetes mellitus and prevention of diabetes-related complications. 109, 41\u201344 (2003).","DOI":"10.1016\/S0301-2115(02)00480-3"},{"issue":"3","key":"41066_CR4","doi-asserted-by":"publisher","first-page":"363","DOI":"10.1001\/jama.284.3.363","volume":"284","author":"Charles M. Clark","year":"2000","unstructured":"Clark, C. M. et al. Promoting early diagnosis and treatment of type 2 diabetes: the National Diabetes Education Program. 284, 363\u2013365 (2000).","journal-title":"JAMA"},{"key":"41066_CR5","doi-asserted-by":"publisher","first-page":"S1","DOI":"10.1002\/dmrr.512","volume":"20","author":"C Valeri","year":"2004","unstructured":"Valeri, C., Pozzilli, P. & Leslie, D. Glucose control in diabetes. Diabetes-Metab Res 20, S1\u2013S8, https:\/\/doi.org\/10.1002\/dmrr.512 (2004).","journal-title":"Diabetes-Metab Res"},{"key":"41066_CR6","doi-asserted-by":"crossref","unstructured":"Meetoo, D. D., McAllister, G. & West, A. Assessing glycaemic control: self-monitoring of blood glucose. Br J Nurs 20 (2011).","DOI":"10.12968\/bjon.2011.20.15.919"},{"key":"41066_CR7","doi-asserted-by":"publisher","first-page":"919","DOI":"10.1177\/193229680800200526","volume":"2","author":"L Heinemann","year":"2008","unstructured":"Heinemann, L. Finger pricking and pain: a never ending story. J Diabetes Sci Technol 2, 919\u2013921, https:\/\/doi.org\/10.1177\/193229680800200526 (2008).","journal-title":"J Diabetes Sci Technol"},{"key":"41066_CR8","doi-asserted-by":"publisher","first-page":"9197","DOI":"10.1039\/c6cc03609k","volume":"52","author":"JT La Belle","year":"2016","unstructured":"La Belle, J. T. et al. Self-monitoring of tear glucose: the development of a tear based glucose sensor as an alternative to self-monitoring of blood glucose. Chem Commun 52, 9197\u20139204, https:\/\/doi.org\/10.1039\/c6cc03609k (2016).","journal-title":"Chem Commun"},{"key":"41066_CR9","doi-asserted-by":"publisher","first-page":"16","DOI":"10.1016\/j.diabres.2006.10.027","volume":"77","author":"A Tura","year":"2007","unstructured":"Tura, A., Maran, A. & Pacini, G. Non-invasive glucose monitoring: Assessment of technologies and devices according to quantitative criteria. Diabetes Res Clin Pr 77, 16\u201340, https:\/\/doi.org\/10.1016\/j.diabres.2006.10.027 (2007).","journal-title":"Diabetes Res Clin Pr"},{"key":"41066_CR10","doi-asserted-by":"publisher","first-page":"16","DOI":"10.1016\/j.aca.2012.03.043","volume":"750","author":"SK Vashist","year":"2012","unstructured":"Vashist, S. K. Non-invasive glucose monitoring technology in diabetes management: A review. Anal Chim Acta 750, 16\u201327, https:\/\/doi.org\/10.1016\/j.aca.2012.03.043 (2012).","journal-title":"Anal Chim Acta"},{"key":"41066_CR11","doi-asserted-by":"publisher","first-page":"280","DOI":"10.1016\/S1542-0124(12)70094-0","volume":"5","author":"JT Baca","year":"2007","unstructured":"Baca, J. T., Finegold, D. N. & Asher, S. A. Tear glucose analysis for the noninvasive detection and monitoring of diabetes mellitus. Ocul Surf 5, 280\u2013293 (2007).","journal-title":"Ocul Surf"},{"key":"41066_CR12","doi-asserted-by":"publisher","first-page":"455","DOI":"10.1016\/j.bios.2015.03.070","volume":"70","author":"C Liu","year":"2015","unstructured":"Liu, C. et al. A glucose oxidase-coupled DNAzyme sensor for glucose detection in tears and saliva. Biosens Bioelectron 70, 455\u2013461 (2015).","journal-title":"Biosens Bioelectron"},{"key":"41066_CR13","doi-asserted-by":"publisher","first-page":"8341","DOI":"10.1021\/ac201700c","volume":"83","author":"QY Yan","year":"2011","unstructured":"Yan, Q. Y. et al. Measurement of Tear Glucose Levels with Amperometric Glucose Biosensor\/Capillary Tube Configuration. Anal Chem 83, 8341\u20138346, https:\/\/doi.org\/10.1021\/ac201700c (2011).","journal-title":"Anal Chem"},{"key":"41066_CR14","doi-asserted-by":"publisher","first-page":"204","DOI":"10.1016\/j.bios.2013.05.014","volume":"49","author":"B Peng","year":"2013","unstructured":"Peng, B. et al. Evaluation of enzyme-based tear glucose electrochemical sensors over a wide range of blood glucose concentrations. Biosens Bioelectron 49, 204\u2013209 (2013).","journal-title":"Biosens Bioelectron"},{"key":"41066_CR15","doi-asserted-by":"publisher","first-page":"873","DOI":"10.1177\/193229680700100611","volume":"1","author":"BD Cameron","year":"2007","unstructured":"Cameron, B. D. & Li, Y. Polarization-based diffuse reflectance imaging for noninvasive measurement of glucose. J Diabetes Sci Technol 1, 873\u2013878 (2007).","journal-title":"J Diabetes Sci Technol"},{"key":"41066_CR16","doi-asserted-by":"publisher","first-page":"4013","DOI":"10.1021\/ac0501238","volume":"77","author":"DA Stuart","year":"2005","unstructured":"Stuart, D. A. et al. Glucose sensing using near-infrared surface-enhanced Raman spectroscopy: Gold surfaces, 10-day stability, and improved accuracy. Anal Chem 77, 4013\u20134019, https:\/\/doi.org\/10.1021\/ac0501238 (2005).","journal-title":"Anal Chem"},{"key":"41066_CR17","doi-asserted-by":"publisher","first-page":"104","DOI":"10.3390\/mi8040104","volume":"8","author":"EFM Gabriel","year":"2017","unstructured":"Gabriel, E. F. M., Garcia, P. T., Lopes, F. M. & Coltro, W. K. T. Based Colorimetric Biosensor for Tear Glucose Measurements. Micromachines 8, 104 (2017).","journal-title":"Micromachines"},{"key":"41066_CR18","doi-asserted-by":"publisher","first-page":"141","DOI":"10.1007\/Bf00410700","volume":"192","author":"W Scherz","year":"1974","unstructured":"Scherz, W., Doane, M. G. & Dohlman, C. H. Tear Volume in Normal Eyes and Keratoconjunctivitis Sicca. A Graef Arch Klin Ex 192, 141\u2013150, https:\/\/doi.org\/10.1007\/Bf00410700 (1974).","journal-title":"A Graef Arch Klin Ex"},{"key":"41066_CR19","first-page":"264","volume":"5","author":"S Mishima","year":"1966","unstructured":"Mishima, S., Gasset, A., Klyce, S. & Baum, J. Determination of tear volume and tear flow. Invest Ophthalmol Vis Sci 5, 264\u2013276 (1966).","journal-title":"Invest Ophthalmol Vis Sci"},{"key":"41066_CR20","doi-asserted-by":"publisher","first-page":"135","DOI":"10.1016\/0014-4835(90)90223-H","volume":"50","author":"GB Vansetten","year":"1990","unstructured":"Vansetten, G. B. et al. Effects of the Schirmer Test on the Fibrinolytic System in the Tear Fluid. Exp Eye Res 50, 135\u2013141, https:\/\/doi.org\/10.1016\/0014-4835(90)90223-H (1990).","journal-title":"Exp Eye Res"},{"key":"41066_CR21","doi-asserted-by":"publisher","first-page":"187","DOI":"10.1111\/j.1475-1313.1982.tb00176.x","volume":"2","author":"CM Haggerty","year":"1982","unstructured":"Haggerty, C. M. & Larke, J. R. Human tear protein fractions during waking hours. Ophthalmic Physiol Opt 2, 187\u2013191 (1982).","journal-title":"Ophthalmic Physiol Opt"},{"key":"41066_CR22","doi-asserted-by":"publisher","first-page":"530","DOI":"10.1111\/j.1755-3768.1984.tb03964.x","volume":"62","author":"KM Daum","year":"1984","unstructured":"Daum, K. M. & Hill, R. M. Human Tears - Glucose Instabilities. Acta Ophthalmol 62, 530\u2013536 (1984).","journal-title":"Acta Ophthalmol"},{"key":"41066_CR23","doi-asserted-by":"publisher","first-page":"1391","DOI":"10.1097\/OPX.0000000000000411","volume":"91","author":"A Rohit","year":"2014","unstructured":"Rohit, A., Stapleton, F., Brown, S. H. J., Mitchell, T. W. & Willcox, M. D. P. Comparison of Tear Lipid Profile among Basal, Reflex, and Flush Tear Samples. Optom Vis Sci 91, 1391\u20131395 (2014).","journal-title":"Optom Vis Sci"},{"key":"41066_CR24","doi-asserted-by":"publisher","first-page":"1902","DOI":"10.1021\/ac4040168","volume":"86","author":"KH Cha","year":"2014","unstructured":"Cha, K. H., Jensen, G. C., Balijepalli, A. S., Cohan, B. E. & Meyerhoff, M. E. Evaluation of commercial glucometer test strips for potential measurement of glucose in tears. Anal Chem 86, 1902\u20131908 (2014).","journal-title":"Anal Chem"},{"key":"41066_CR25","doi-asserted-by":"publisher","first-page":"58","DOI":"10.1111\/j.1755-3768.1973.tb08246.x","volume":"51","author":"M Norn","year":"1973","unstructured":"Norn, M. Conjunctival sensitivity in normal eyes. Acta Ophthalmol 51, 58\u201366 (1973).","journal-title":"Acta Ophthalmol"},{"issue":"9","key":"41066_CR26","doi-asserted-by":"publisher","first-page":"1163","DOI":"10.1097\/ICO.0000000000001603","volume":"37","author":"Seung Ho Lee","year":"2018","unstructured":"Lee, S. H. et al. Designing Minimally Invasive Preocular Contact Tips for Potential Application in Tear Collection. Cornea, https:\/\/doi.org\/10.1097\/ico.0000000000001603 (2018).","journal-title":"Cornea"},{"key":"41066_CR27","doi-asserted-by":"publisher","first-page":"670","DOI":"10.1002\/elan.201400576","volume":"27","author":"KH Cha","year":"2015","unstructured":"Cha, K. H., Qin, Y. & Meyerhoff, M. E. Origin of Low Detection Limit and High Selectivity of Roche Accu\u2010Chek Test Strips that Enables Measurement of Tear Glucose Levels. Electroanal 27, 670\u2013676 (2015).","journal-title":"Electroanal"},{"key":"41066_CR28","doi-asserted-by":"publisher","first-page":"960","DOI":"10.1016\/j.talanta.2010.10.055","volume":"83","author":"MX Chu","year":"2011","unstructured":"Chu, M. X. et al. Soft contact lens biosensor for in situ monitoring of tear glucose as non-invasive blood sugar assessment. Talanta 83, 960\u2013965, https:\/\/doi.org\/10.1016\/j.talanta.2010.10.055 (2011).","journal-title":"Talanta"},{"key":"41066_CR29","doi-asserted-by":"publisher","first-page":"622","DOI":"10.2337\/diacare.10.5.622","volume":"10","author":"WL Clarke","year":"1987","unstructured":"Clarke, W. L., Cox, D., Gonderfrederick, L. A., Carter, W. & Pohl, S. L. Evaluating Clinical Accuracy of Systems for Self-Monitoring of Blood-Glucose. Diabetes Care 10, 622\u2013628, https:\/\/doi.org\/10.2337\/diacare.10.5.622 (1987).","journal-title":"Diabetes Care"},{"key":"41066_CR30","doi-asserted-by":"publisher","first-page":"776","DOI":"10.1089\/dia.2005.7.776","volume":"7","author":"WL Clarke","year":"2005","unstructured":"Clarke, W. L. The original Clarke error grid analysis (EGA). Diabetes Technol Ther 7, 776\u2013779 (2005).","journal-title":"Diabetes Technol Ther"},{"key":"41066_CR31","doi-asserted-by":"publisher","first-page":"61","DOI":"10.1097\/ICL.0b013e31811ead93","volume":"34","author":"DR Korb","year":"2008","unstructured":"Korb, D. R., Herman, J. P., Finnemore, V. M., Exford, J. M. & Blackie, C. A. An evaluation of the efficacy of fluorescein, rose bengal, lissamine green, and a new dye mixture for ocular surface staining. Eye Contact Lens 34, 61\u201364, https:\/\/doi.org\/10.1097\/ICL.0b013e31811ead93 (2008).","journal-title":"Eye Contact Lens"},{"key":"41066_CR32","doi-asserted-by":"publisher","first-page":"166","DOI":"10.1177\/193229681100500123","volume":"5","author":"J Zhang","year":"2011","unstructured":"Zhang, J., Hodge, W., Hutnick, C. & Wang, X. Noninvasive diagnostic devices for diabetes through measuring tear glucose. J Diabetes Sci Technol 5, 166\u2013172 (2011).","journal-title":"J Diabetes Sci Technol"},{"key":"41066_CR33","doi-asserted-by":"publisher","first-page":"1370","DOI":"10.1373\/clinchem.2006.078543","volume":"53","author":"JT Baca","year":"2007","unstructured":"Baca, J. T. et al. Mass spectral determination of fasting tear glucose concentrations in nondiabetic volunteers. Clin Chem 53, 1370\u20131372, https:\/\/doi.org\/10.1373\/clinchem.2006.078543 (2007).","journal-title":"Clin Chem"},{"key":"41066_CR34","doi-asserted-by":"publisher","first-page":"332","DOI":"10.1016\/j.jasms.2006.10.002","volume":"18","author":"CR Taormina","year":"2007","unstructured":"Taormina, C. R., Baca, J. T., Asher, S. A., Grabowski, J. J. & Finegold, D. N. Analysis of tear glucose concentration with electrospray ionization mass spectrometry. J Am Soc Mass Spectr 18, 332\u2013336, https:\/\/doi.org\/10.1016\/j.jasms.2006.10.002 (2007).","journal-title":"J Am Soc Mass Spectr"},{"key":"41066_CR35","doi-asserted-by":"publisher","first-page":"1602","DOI":"10.1039\/tf9595501602","volume":"55","author":"RE Collins","year":"1959","unstructured":"Collins, R. E. & Cooke, C. E. Fundamental Basis for the Contact Angle and Capillary Pressure. T Faraday Soc 55, 1602\u20131606, https:\/\/doi.org\/10.1039\/tf9595501602 (1959).","journal-title":"T Faraday Soc"},{"key":"41066_CR36","unstructured":"Al-Achi, A., Gupta, M. R. & Stagner, W. C. Integrated Pharmaceutics: Applied Preformulation, Product Design, And Regulatory Science. 575 (John Wiley & Sons, 2013)."},{"key":"41066_CR37","doi-asserted-by":"publisher","first-page":"760","DOI":"10.1089\/jop.2012.0175","volume":"29","author":"MA Patane","year":"2013","unstructured":"Patane, M. A. et al. Evaluation of Ocular and General Safety Following Repeated Dosing of Dexamethasone Phosphate Delivered by Transscleral Iontophoresis in Rabbits. J Ocul Pharmacol Th 29, 760\u2013769, https:\/\/doi.org\/10.1089\/jop.2012.0175 (2013).","journal-title":"J Ocul Pharmacol Th"},{"key":"41066_CR38","doi-asserted-by":"publisher","first-page":"895","DOI":"10.1080\/02713680600976552","volume":"31","author":"JD Lane","year":"2006","unstructured":"Lane, J. D., Krumholz, D. M., Sack, R. A. & Morris, C. Tear glucose dynamics in diabetes mellitus. Curr Eye Res 31, 895\u2013901 (2006).","journal-title":"Curr Eye Res"},{"key":"41066_CR39","doi-asserted-by":"publisher","first-page":"708","DOI":"10.1046\/j.1464-5491.2002.00835.x","volume":"19","author":"N Unwin","year":"2002","unstructured":"Unwin, N., Shaw, J., Zimmet, P. & Alberti, K. G. M. M. Impaired glucose tolerance and impaired fasting glycaemia: the current status on definition and intervention. Diabetic Med 19, 708\u2013723 (2002).","journal-title":"Diabetic Med"}],"updated-by":[{"DOI":"10.1038\/s41598-019-49489-z","type":"correction","label":"Correction","source":"publisher","updated":{"date-parts":[[2019,9,3]],"date-time":"2019-09-03T00:00:00Z","timestamp":1567468800000}}],"container-title":["Scientific Reports"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.nature.com\/articles\/s41598-019-41066-8.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.nature.com\/articles\/s41598-019-41066-8","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.nature.com\/articles\/s41598-019-41066-8.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2022,12,17]],"date-time":"2022-12-17T07:51:28Z","timestamp":1671263488000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.nature.com\/articles\/s41598-019-41066-8"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2019,3,20]]},"references-count":39,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2019,12]]}},"alternative-id":["41066"],"URL":"https:\/\/doi.org\/10.1038\/s41598-019-41066-8","relation":{"correction":[{"id-type":"doi","id":"10.1038\/s41598-019-49489-z","asserted-by":"object"}]},"ISSN":["2045-2322"],"issn-type":[{"value":"2045-2322","type":"electronic"}],"subject":[],"published":{"date-parts":[[2019,3,20]]},"assertion":[{"value":"19 June 2018","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"28 February 2019","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"20 March 2019","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"3 September 2019","order":4,"name":"change_date","label":"Change Date","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"Correction","order":5,"name":"change_type","label":"Change Type","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"An amendment to this paper has been published and can be accessed via a link at the top of the paper.","order":6,"name":"change_details","label":"Change Details","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"The authors declare no competing interests.","order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing Interests"}}],"article-number":"4747"}}