{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,11,19]],"date-time":"2025-11-19T07:00:26Z","timestamp":1763535626908,"version":"3.37.3"},"reference-count":36,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2019,6,26]],"date-time":"2019-06-26T00:00:00Z","timestamp":1561507200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2019,6,26]],"date-time":"2019-06-26T00:00:00Z","timestamp":1561507200000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"funder":[{"name":"UCLA Physical Sciences Entrepreneurship and Innovation Fund Award"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Sci Rep"],"abstract":"<jats:title>Abstract<\/jats:title><jats:p>Palpable thyroid lesions are common, and although mostly benign, lethal malignant nodules do occur and may be difficult to differentiate. Here, we introduce the use of a piezoelectric system called Smart-touch fine needle (or STFN) mounted directly onto conventional biopsy needles, to evaluate abnormal tissues, through quantitative real-time measurements of variations in tissue stiffness as the needle penetrates tissue. Using well-characterized biomaterials of known stiffness and explanted animal tissue models, we first established experimental protocols for STFN measures on biological tissues, as well as optimized device design for high signal-to-noise ratio. Freshly excised patient thyroids with varying fibrotic and malignant potential revealed discrete variations in STFN based tissue stiffness\/stiffness heterogeneity and correlated well with final histopathology. Our piezoelectric needle sensor reveals mechanical heterogeneity in thyroid tissue lesions and provides a foundation for the design of hand-held tools for the rapid, mechano-profiling of malignant lesions <jats:italic>in vivo<\/jats:italic> while performing fine needle aspiration (FNA).<\/jats:p>","DOI":"10.1038\/s41598-019-45730-x","type":"journal-article","created":{"date-parts":[[2019,6,26]],"date-time":"2019-06-26T10:02:56Z","timestamp":1561543376000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":19,"title":["Piezoelectric needle sensor reveals mechanical heterogeneity in human thyroid tissue lesions"],"prefix":"10.1038","volume":"9","author":[{"given":"Shivani","family":"Sharma","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Renato","family":"Aguilera","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"JianYu","family":"Rao","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-4333-6957","authenticated-orcid":false,"given":"James K.","family":"Gimzewski","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2019,6,26]]},"reference":[{"key":"45730_CR1","doi-asserted-by":"publisher","first-page":"1764","DOI":"10.1056\/NEJMcp031436","volume":"351","author":"L Hegedus","year":"2004","unstructured":"Hegedus, L. Clinical practice. The thyroid nodule. The New England journal of medicine 351, 1764\u20131771, https:\/\/doi.org\/10.1056\/NEJMcp031436 (2004).","journal-title":"The New England journal of medicine"},{"key":"45730_CR2","doi-asserted-by":"publisher","first-page":"9","DOI":"10.3322\/caac.21208","volume":"64","author":"R Siegel","year":"2014","unstructured":"Siegel, R., Ma, J., Zou, Z. & Jemal, A. Cancer statistics, 2014. CA: a cancer journal for clinicians 64, 9\u201329, https:\/\/doi.org\/10.3322\/caac.21208 (2014).","journal-title":"CA: a cancer journal for clinicians"},{"key":"45730_CR3","doi-asserted-by":"publisher","first-page":"372","DOI":"10.1002\/cncr.30360","volume":"123","author":"BR Haugen","year":"2017","unstructured":"Haugen, B. R. 2015 American Thyroid Association Management Guidelines for Adult Patients with Thyroid Nodules and Differentiated Thyroid Cancer: What is new and what has changed? Cancer 123, 372\u2013381, https:\/\/doi.org\/10.1002\/cncr.30360 (2017).","journal-title":"Cancer"},{"key":"45730_CR4","doi-asserted-by":"publisher","first-page":"791","DOI":"10.4158\/EP151150.OR","volume":"22","author":"RDA Kulstad","year":"2016","unstructured":"Kulstad, R. D. A. Thyroid Nodules >4 Cm Need to Be Removed? An Evaluation of Thyroid Fine-Needle Aspiration Biopsy in Large Thyroid Nodules. Endocrine practice: official journal of the American College of Endocrinology and the American Association of Clinical Endocrinologists 22, 791\u2013798, https:\/\/doi.org\/10.4158\/EP151150.OR (2016).","journal-title":"Endocrine practice: official journal of the American College of Endocrinology and the American Association of Clinical Endocrinologists"},{"key":"45730_CR5","doi-asserted-by":"publisher","first-page":"25","DOI":"10.1002\/dc.2840020107","volume":"2","author":"JF Silverman","year":"1986","unstructured":"Silverman, J. F. et al. Fine-needle aspiration versus large-needle biopsy or cutting biopsy in evaluation of thyroid nodules. Diagn Cytopathol 2, 25\u201330 (1986).","journal-title":"Diagn Cytopathol"},{"key":"45730_CR6","doi-asserted-by":"publisher","first-page":"413","DOI":"10.1016\/j.actbio.2007.04.002","volume":"3","author":"S Suresh","year":"2007","unstructured":"Suresh, S. Biomechanics and biophysics of cancer cells. Acta biomaterialia 3, 413\u2013438 (2007).","journal-title":"Acta biomaterialia"},{"key":"45730_CR7","doi-asserted-by":"publisher","first-page":"512","DOI":"10.1038\/nrc3080","volume":"11","author":"D Wirtz","year":"2011","unstructured":"Wirtz, D., Konstantopoulos, K. & Searson, P. C. The physics of cancer: the role of physical interactions and mechanical forces in metastasis. Nature reviews. Cancer 11, 512\u2013522, https:\/\/doi.org\/10.1038\/nrc3080 (2011).","journal-title":"Nature reviews. Cancer"},{"key":"45730_CR8","doi-asserted-by":"publisher","first-page":"321","DOI":"10.1146\/annurev-bioeng-071813-105259","volume":"16","author":"RK Jain","year":"2014","unstructured":"Jain, R. K., Martin, J. D. & Stylianopoulos, T. The role of mechanical forces in tumor growth and therapy. Annual review of biomedical engineering 16, 321\u2013346, https:\/\/doi.org\/10.1146\/annurev-bioeng-071813-105259 (2014).","journal-title":"Annual review of biomedical engineering"},{"key":"45730_CR9","doi-asserted-by":"publisher","first-page":"1788","DOI":"10.1001\/jamainternmed.2013.9245","volume":"173","author":"R Smith-Bindman","year":"2013","unstructured":"Smith-Bindman, R. et al. Risk of thyroid cancer based on thyroid ultrasound imaging characteristics: results of a population-based study. JAMA internal medicine 173, 1788\u20131796, https:\/\/doi.org\/10.1001\/jamainternmed.2013.9245 (2013).","journal-title":"JAMA internal medicine"},{"key":"45730_CR10","doi-asserted-by":"publisher","first-page":"212","DOI":"10.14366\/usg.15074","volume":"35","author":"DG Na","year":"2016","unstructured":"Na, D. G., Kim, D. S., Kim, S. J., Ryoo, J. W. & Jung, S. L. Thyroid nodules with isolated macrocalcification: malignancy risk and diagnostic efficacy of fine-needle aspiration and core needle biopsy. Ultrasonography 35, 212\u2013219, https:\/\/doi.org\/10.14366\/usg.15074 (2016).","journal-title":"Ultrasonography"},{"key":"45730_CR11","doi-asserted-by":"publisher","first-page":"448","DOI":"10.2214\/AJR.14.13448","volume":"205","author":"WA Berg","year":"2015","unstructured":"Berg, W. A. et al. Quantitative Maximum Shear-Wave Stiffness of Breast Masses as a Predictor of Histopathologic Severity. AJR Am J Roentgenol 205, 448\u2013455, https:\/\/doi.org\/10.2214\/AJR.14.13448 (2015).","journal-title":"AJR Am J Roentgenol"},{"key":"45730_CR12","doi-asserted-by":"publisher","first-page":"37","DOI":"10.1016\/j.ultrasmedbio.2017.09.012","volume":"44","author":"R Guo","year":"2018","unstructured":"Guo, R., Lu, G., Qin, B. & Fei, B. Ultrasound Imaging Technologies for Breast Cancer Detection and Management: A Review. Ultrasound Med Biol 44, 37\u201370, https:\/\/doi.org\/10.1016\/j.ultrasmedbio.2017.09.012 (2018).","journal-title":"Ultrasound Med Biol"},{"issue":"06","key":"45730_CR13","doi-asserted-by":"publisher","first-page":"550","DOI":"10.1055\/s-0035-1553293","volume":"36","author":"J. Carlsen","year":"2015","unstructured":"Carlsen, J. et al. Ultrasound Elastography in Breast Cancer Diagnosis. Ultraschall Med 36, 550\u2013562, quiz 563\u2013555, https:\/\/doi.org\/10.1055\/s-0035-1553293 (2015).","journal-title":"Ultraschall in der Medizin - European Journal of Ultrasound"},{"key":"45730_CR14","doi-asserted-by":"publisher","first-page":"1015","DOI":"10.1007\/s00330-012-2686-9","volume":"23","author":"SH Lee","year":"2013","unstructured":"Lee, S. H. et al. Differentiation of benign from malignant solid breast masses: comparison of two-dimensional and three-dimensional shear-wave elastography. Eur Radiol 23, 1015\u20131026, https:\/\/doi.org\/10.1007\/s00330-012-2686-9 (2013).","journal-title":"Eur Radiol"},{"key":"45730_CR15","doi-asserted-by":"publisher","first-page":"2336","DOI":"10.1016\/j.ultrasmedbio.2014.05.020","volume":"40","author":"JH Youk","year":"2014","unstructured":"Youk, J. H. et al. Comparison of strain and shear wave elastography for the differentiation of benign from malignant breast lesions, combined with B-mode ultrasonography: qualitative and quantitative assessments. Ultrasound Med Biol 40, 2336\u20132344, https:\/\/doi.org\/10.1016\/j.ultrasmedbio.2014.05.020 (2014).","journal-title":"Ultrasound Med Biol"},{"key":"45730_CR16","doi-asserted-by":"publisher","first-page":"16","DOI":"10.11152\/mu-925","volume":"19","author":"Y Jiao","year":"2017","unstructured":"Jiao, Y. et al. Shear wave elastography imaging for detecting malignant lesions of the liver: a systematic review and pooled meta-analysis. Medical ultrasonography 19, 16\u201322, https:\/\/doi.org\/10.11152\/mu-925 (2017).","journal-title":"Medical ultrasonography"},{"key":"45730_CR17","doi-asserted-by":"publisher","first-page":"101","DOI":"10.1016\/j.gtc.2015.10.010","volume":"45","author":"MM Xu","year":"2016","unstructured":"Xu, M. M. & Sethi, A. Imaging of the Pancreas. Gastroenterology clinics of North America 45, 101\u2013116, https:\/\/doi.org\/10.1016\/j.gtc.2015.10.010 (2016).","journal-title":"Gastroenterology clinics of North America"},{"key":"45730_CR18","doi-asserted-by":"publisher","first-page":"e8282","DOI":"10.1097\/MD.0000000000008282","volume":"96","author":"X Hu","year":"2017","unstructured":"Hu, X., Liu, Y. & Qian, L. Diagnostic potential of real-time elastography (RTE) and shear wave elastography (SWE) to differentiate benign and malignant thyroid nodules: A systematic review and meta-analysis. Medicine 96, e8282, https:\/\/doi.org\/10.1097\/MD.0000000000008282 (2017).","journal-title":"Medicine"},{"key":"45730_CR19","doi-asserted-by":"publisher","first-page":"165","DOI":"10.1038\/s41551-018-0201-6","volume":"2","author":"X Yu","year":"2018","unstructured":"Yu, X. et al. Needle-shaped ultrathin piezoelectric microsystem for guided tissue targeting via mechanical sensing. Nature Biomedical Engineering 2, 165\u2013172, https:\/\/doi.org\/10.1038\/s41551-018-0201-6 (2018).","journal-title":"Nature Biomedical Engineering"},{"key":"45730_CR20","doi-asserted-by":"publisher","first-page":"384003","DOI":"10.1088\/0957-4484\/19\/38\/384003","volume":"19","author":"SE Cross","year":"2008","unstructured":"Cross, S. E. et al. AFM-based analysis of human metastatic cancer cells. Nanotechnology 19, 384003, https:\/\/doi.org\/10.1088\/0957-4484\/19\/38\/384003 (2008).","journal-title":"Nanotechnology"},{"key":"45730_CR21","doi-asserted-by":"publisher","first-page":"757","DOI":"10.1016\/j.nano.2011.09.015","volume":"8","author":"S Sharma","year":"2012","unstructured":"Sharma, S. et al. Correlative nanomechanical profiling with super-resolution F-actin imaging reveals novel insights into mechanisms of cisplatin resistance in ovarian cancer cells. Nanomedicine: nanotechnology, biology, and medicine 8, 757\u2013766, https:\/\/doi.org\/10.1016\/j.nano.2011.09.015 (2012).","journal-title":"Nanomedicine: nanotechnology, biology, and medicine"},{"key":"45730_CR22","doi-asserted-by":"publisher","DOI":"10.1038\/s42254-018-0001-7","author":"M Krieg","year":"2018","unstructured":"Krieg, M. et al. Atomic force microscopy-based mechanobiology. Nature Reviews Physics. https:\/\/doi.org\/10.1038\/s42254-018-0001-7 (2018).","journal-title":"Nature Reviews Physics"},{"key":"45730_CR23","doi-asserted-by":"publisher","first-page":"054303","DOI":"10.1063\/1.3127602","volume":"80","author":"P Hansma","year":"2009","unstructured":"Hansma, P. et al. The tissue diagnostic instrument. Rev Sci Instrum 80, 054303 (2009).","journal-title":"Rev Sci Instrum"},{"issue":"19","key":"45730_CR24","first-page":"194120","volume":"22","author":"I Levental","year":"2010","unstructured":"Levental, I. et al. A simple indentation device for measuring micrometer-scale tissue stiffness. J Phys Condens Matter 22, 194120, S0953-8984(10)33266-8 [pii]\u2009=\u200910.1088\/0953-8984\/22\/19\/194120 (2010).","journal-title":"Journal of Physics: Condensed Matter"},{"key":"45730_CR25","doi-asserted-by":"publisher","DOI":"10.1186\/1754-1611-2-12","volume":"2","author":"N Ragavendra","year":"2008","unstructured":"Ragavendra, N. et al. In vivo analysis of fracture toughness of thyroid gland tumors. J Biol Eng 2, 12 (2008).","journal-title":"J Biol Eng"},{"key":"45730_CR26","doi-asserted-by":"publisher","DOI":"10.1038\/s41598-017-13391-3","volume":"7","author":"J Luo","year":"2017","unstructured":"Luo, J. et al. Risk of malignancy in thyroid nodules: predictive value of puncture feeling of grittiness in the process of fine-needle aspiration. Sci Rep 7, 13109, https:\/\/doi.org\/10.1038\/s41598-017-13391-3 (2017).","journal-title":"Sci Rep"},{"key":"45730_CR27","doi-asserted-by":"publisher","first-page":"25","DOI":"10.2147\/CHC.S71852","volume":"7","author":"VK Chivukula","year":"2015","unstructured":"Chivukula, V. K., Krog, B. L., Nauseef, J. T., Henry, M. D. & Vigmostad, S. C. Alterations in cancer cell mechanical properties after fluid shear stress exposure: a micropipette aspiration study. Cell health and cytoskeleton 7, 25\u201335, https:\/\/doi.org\/10.2147\/CHC.S71852 (2015).","journal-title":"Cell health and cytoskeleton"},{"key":"45730_CR28","doi-asserted-by":"publisher","first-page":"780","DOI":"10.1038\/nnano.2007.388","volume":"2","author":"SE Cross","year":"2007","unstructured":"Cross, S. E., Jin, Y. S., Rao, J. & Gimzewski, J. K. Nanomechanical analysis of cells from cancer patients. Nature nanotechnology 2, 780\u2013783, https:\/\/doi.org\/10.1038\/nnano.2007.388 (2007).","journal-title":"Nature nanotechnology"},{"key":"45730_CR29","doi-asserted-by":"publisher","first-page":"757","DOI":"10.1038\/nnano.2012.167","volume":"7","author":"M Plodinec","year":"2012","unstructured":"Plodinec, M. et al. The nanomechanical signature of breast cancer. Nature nanotechnology 7, 757\u2013765 (2012).","journal-title":"Nature nanotechnology"},{"key":"45730_CR30","doi-asserted-by":"publisher","first-page":"930","DOI":"10.1103\/PhysRevLett.56.930","volume":"56","author":"G Binnig","year":"1986","unstructured":"Binnig, G., Quate, C. F. & Gerber, C. Atomic force microscope. Phys Rev Lett 56, 930\u2013933 (1986).","journal-title":"Phys Rev Lett"},{"key":"45730_CR31","doi-asserted-by":"publisher","first-page":"1777","DOI":"10.1016\/j.nano.2014.06.010","volume":"10","author":"J Kwok","year":"2014","unstructured":"Kwok, J. et al. Atomic force microscopy reveals age-dependent changes in nanomechanical properties of the extracellular matrix of native human menisci: implications for joint degeneration and osteoarthritis. Nanomedicine: nanotechnology, biology, and medicine 10, 1777\u20131785, https:\/\/doi.org\/10.1016\/j.nano.2014.06.010 (2014).","journal-title":"Nanomedicine: nanotechnology, biology, and medicine"},{"key":"45730_CR32","doi-asserted-by":"publisher","first-page":"1817","DOI":"10.1557\/adv.2016.255","volume":"1","author":"S Sharma","year":"2016","unstructured":"Sharma, S. & Gimzewski, J. K. Application of AFM to the Nanomechanics of Cancer. MRS Advances 1, 1817\u20131827, https:\/\/doi.org\/10.1557\/adv.2016.255 (2016).","journal-title":"MRS Advances"},{"key":"45730_CR33","doi-asserted-by":"publisher","first-page":"81","DOI":"10.1016\/j.jbiomech.2014.10.038","volume":"48","author":"D Wickramaratne","year":"2015","unstructured":"Wickramaratne, D. et al. Fine Needle Elastography (FNE) device for biomechanically determining local variations of tissue mechanical properties. Journal of biomechanics 48, 81\u201388, https:\/\/doi.org\/10.1016\/j.jbiomech.2014.10.038 (2015).","journal-title":"Journal of biomechanics"},{"key":"45730_CR34","doi-asserted-by":"publisher","first-page":"665","DOI":"10.1016\/j.medengphy.2012.04.007","volume":"34","author":"DJ van Gerwen","year":"2012","unstructured":"van Gerwen, D. J., Dankelman, J. & van den Dobbelsteen, J. J. Needle-tissue interaction forces\u2013a survey of experimental data. Medical engineering & physics 34, 665\u2013680, https:\/\/doi.org\/10.1016\/j.medengphy.2012.04.007 (2012).","journal-title":"Medical engineering & physics"},{"key":"45730_CR35","doi-asserted-by":"publisher","first-page":"1707","DOI":"10.1109\/TBME.2004.831542","volume":"51","author":"AM Okamura","year":"2004","unstructured":"Okamura, A. M., Simone, C. & O\u2019Leary, M. D. Force modeling for needle insertion into soft tissue. IEEE transactions on bio-medical engineering 51, 1707\u20131716, https:\/\/doi.org\/10.1109\/TBME.2004.831542 (2004).","journal-title":"IEEE transactions on bio-medical engineering"},{"key":"45730_CR36","doi-asserted-by":"publisher","first-page":"685","DOI":"10.1007\/s10439-013-0924-1","volume":"42","author":"DJ van Gerwen","year":"2014","unstructured":"van Gerwen, D. J., Dankelman, J. & van den Dobbelsteen, J. J. Measurement and stochastic modeling of kidney puncture forces. Annals of biomedical engineering 42, 685\u2013695, https:\/\/doi.org\/10.1007\/s10439-013-0924-1 (2014).","journal-title":"Annals of biomedical engineering"}],"container-title":["Scientific Reports"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.nature.com\/articles\/s41598-019-45730-x.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.nature.com\/articles\/s41598-019-45730-x","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.nature.com\/articles\/s41598-019-45730-x.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2022,12,17]],"date-time":"2022-12-17T10:56:52Z","timestamp":1671274612000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.nature.com\/articles\/s41598-019-45730-x"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2019,6,26]]},"references-count":36,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2019,12]]}},"alternative-id":["45730"],"URL":"https:\/\/doi.org\/10.1038\/s41598-019-45730-x","relation":{},"ISSN":["2045-2322"],"issn-type":[{"type":"electronic","value":"2045-2322"}],"subject":[],"published":{"date-parts":[[2019,6,26]]},"assertion":[{"value":"7 December 2018","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"10 June 2019","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"26 June 2019","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"The authors declare no competing interests.","order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing Interests"}}],"article-number":"9282"}}