{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,24]],"date-time":"2026-10-24T06:07:54Z","timestamp":1792822074823,"version":"4.5.0"},"reference-count":17,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2019,7,9]],"date-time":"2019-07-09T00:00:00Z","timestamp":1562630400000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2019,7,9]],"date-time":"2019-07-09T00:00:00Z","timestamp":1562630400000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Sci Rep"],"abstract":"<jats:title>Abstract<\/jats:title><jats:p>The aim of this study was to assess the central macular imaging captured with an optical biometer based on full-eye-length Swept-Source OCT (SS-OCT) scan as a screening strategy for identifying macular diseases in patients scheduled for cataract surgery. 1,114 eyes of 749 consecutive patients underwent a biometrical examination with IOLMaster 700 SS-OCT technology (Carl Zeiss) and conventional Spectral-Domain OCT (SD-OCT) (Spectralis OCT, Heidelberg) device analysis on the same day. Seven examiners graded the scans individually in a full-masked mode. Twenty-five eyes were excluded for media opacities. Among the 1,089 included eyes, statistical analysis revealed a mean Kendall\u2019s Coefficient of 0.83 (range 0.76\u20130.89). A logistic regression model demonstrated a highly significant correlation (p\u2009&lt;\u20090.001) between the coefficient of concordance and SD-OCT imaging. Intraobserver reproducibility was 0.89 (range 0.86\u20130.91). Optical biometer SS-OCT scans showed a mean sensitivity of 0.81 and a mean specificity of 0.84. The positive and negative predictive value detected was 0.78 and 0.86, respectively. In order to predict the risk of reduced visual recovery, especially in cases of retinal pathology, optical biometer with SS-OCT scan has proven to be a useful modality for detecting macular structural abnormalities in patients undergoing cataract surgery. Conventional SD-OCT remains mandatory to confirm the presumed diagnosis.<\/jats:p>","DOI":"10.1038\/s41598-019-46243-3","type":"journal-article","created":{"date-parts":[[2019,7,9]],"date-time":"2019-07-09T13:01:56Z","timestamp":1562677316000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":18,"title":["Swept-Source Optical Coherence Tomography Biometer as Screening Strategy for Macular Disease in Patients Scheduled for Cataract Surgery"],"prefix":"10.1038","volume":"9","author":[{"given":"Daniele","family":"Tognetto","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-4725-1590","authenticated-orcid":false,"given":"Marco R.","family":"Pastore","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-7033-1911","authenticated-orcid":false,"given":"Chiara","family":"De Giacinto","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Riccardo","family":"Merli","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Marco","family":"Franzon","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Rossella","family":"D\u2019Aloisio","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Lorenzo","family":"Belfanti","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Rosa","family":"Giglio","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Gabriella","family":"Cirigliano","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2019,7,9]]},"reference":[{"key":"46243_CR1","doi-asserted-by":"publisher","first-page":"81","DOI":"10.1097\/ICU.0000000000000441","volume":"29","author":"VS Sangwan","year":"2018","unstructured":"Sangwan, V. S., Gupta, S. & Das, S. Cataract surgery in ocular surface diseases: clinical challenges and outcomes. Curr Opin Ophthalmol 29, 81\u201387 (2018).","journal-title":"Curr Opin Ophthalmol"},{"key":"46243_CR2","first-page":"CD001054","volume":"20","author":"EL Clarke","year":"2018","unstructured":"Clarke, E. L., Evans, J. R. & Smeeth, L. Community screening for visual impairment in older people. Cochrane Database Syst Rev 20, CD001054 (2018).","journal-title":"Cochrane Database Syst Rev"},{"key":"46243_CR3","doi-asserted-by":"publisher","first-page":"2","DOI":"10.1016\/j.ophtha.2013.10.002","volume":"121","author":"JC Erie","year":"2014","unstructured":"Erie, J. C. Rising cataract surgery rates: demand and supply. Ophthalmology 121, 2\u20134 (2014).","journal-title":"Ophthalmology"},{"key":"46243_CR4","doi-asserted-by":"publisher","first-page":"324","DOI":"10.1016\/j.jcrs.2016.12.022","volume":"43","author":"S Zafar","year":"2017","unstructured":"Zafar, S., Siddiqui, M. A. R., Shahzad, R. & Shahzad, M. H. Swept-source optical coherence tomography to screen for macular pathology in eyes having routine cataract surgery. J Cataract Refract Surg 43, 324\u2013327 (2017).","journal-title":"J Cataract Refract Surg"},{"key":"46243_CR5","doi-asserted-by":"publisher","first-page":"39","DOI":"10.1097\/ICU.0000000000000115","volume":"26","author":"M Ali Khan","year":"2015","unstructured":"Ali Khan, M., Skidmore, K. & Ho, A. C. Perioperative retina evaluation of the cataract surgery patient. Curr Opin Ophthalmol 26, 39\u201344 (2015).","journal-title":"Curr Opin Ophthalmol"},{"key":"46243_CR6","doi-asserted-by":"publisher","DOI":"10.1038\/s41598-018-22807-7","volume":"8","author":"X Huang","year":"2018","unstructured":"Huang, X. et al. Macular assessment of preoperative optical coherence tomography in ageing Chinese undergoing routine cataract surgery. Sci Rep 8, 5103 (2018).","journal-title":"Sci Rep"},{"key":"46243_CR7","doi-asserted-by":"publisher","first-page":"765","DOI":"10.1111\/j.1369-7625.2012.00801.x","volume":"17","author":"S Garcia-Gutierrez","year":"2014","unstructured":"Garcia-Gutierrez, S. et al. Impact of clinical and patient-reported outcomes on patient satisfaction with cataract extraction. Health Expect 17, 765\u2013775 (2014).","journal-title":"Health Expect"},{"key":"46243_CR8","doi-asserted-by":"publisher","first-page":"552","DOI":"10.5301\/ejo.5000630","volume":"25","author":"T Bertelmann","year":"2015","unstructured":"Bertelmann, T. et al. Foveal pit morphology evaluation during optical biometry measurements using a full-eye-length swept-source OCT scan biometer prototype. Eur J Ophthalmol 25, 552\u2013558 (2015).","journal-title":"Eur J Ophthalmol"},{"key":"46243_CR9","doi-asserted-by":"publisher","first-page":"530","DOI":"10.1016\/j.jcrs.2016.02.029","volume":"42","author":"N Hirnschall","year":"2016","unstructured":"Hirnschall, N., Leisser, C., Radda, S., Maedel, S. & Findl, O. Macular disease detection with a swept-source optical coherence tomography-based biometry device in patients scheduled for cataract surgery. J Cataract Refract Surg 42, 530\u2013536 (2016).","journal-title":"J Cataract Refract Surg"},{"key":"46243_CR10","doi-asserted-by":"publisher","first-page":"50","DOI":"10.1016\/j.jcrs.2015.07.042","volume":"42","author":"HJ Shammas","year":"2016","unstructured":"Shammas, H. J., Ortiz, S., Shammas, M. C., Kim, S. H. & Chong, C. Biometry measurements using a new large-coherence-length swept-source optical coherence tomographer. J Cataract Refract Surg 42, 50\u201361 (2016).","journal-title":"J Cataract Refract Surg"},{"key":"46243_CR11","doi-asserted-by":"publisher","first-page":"1544","DOI":"10.1016\/j.jcrs.2016.06.039","volume":"42","author":"CS Tan","year":"2016","unstructured":"Tan, C. S. & Cheong, K. X. Detecting macular disease with a biometry device using swept-source optical coherence tomography. J Cataract Refract Surg 42, 1544\u20131545 (2016).","journal-title":"J Cataract Refract Surg"},{"key":"46243_CR12","doi-asserted-by":"publisher","first-page":"354","DOI":"10.1136\/bjophthalmol-2014-305331","volume":"99","author":"CS Tan","year":"2015","unstructured":"Tan, C. S., Ngo, W. K. & Cheong, K. X. Comparison of choroidal thicknesses using swept source and spectral domain optical coherence tomography in diseased and normal eyes. Br J Ophthalmol 99, 354\u2013358 (2015).","journal-title":"Br J Ophthalmol"},{"key":"46243_CR13","doi-asserted-by":"publisher","first-page":"2188","DOI":"10.1097\/IAE.0000000000000847","volume":"35","author":"WA Samara","year":"2015","unstructured":"Samara, W. A. et al. Correlation of foveal avascular zone size with foveal morphology in normal eyes using optical coherence tomography angiography. Retina 35, 2188\u20132195 (2015).","journal-title":"Retina"},{"key":"46243_CR14","unstructured":"R Core Team. R: A Language and Environment for Statistical Computing. R Foundation for Statistical Computing, http:\/\/www.R-project.org\/ (2014)."},{"key":"46243_CR15","doi-asserted-by":"publisher","first-page":"1129","DOI":"10.1016\/S0895-4356(03)00177-X","volume":"56","author":"AS Glas","year":"2003","unstructured":"Glas, A. S., Lijmer, J. G., Prins, M. H., Bonsel, G. J. & Bossuyt, P. M. M. The diagnostic odds ratio: a single indicator of test performance. J Clin Epidemiol 56, 1129\u20131135 (2003).","journal-title":"J Clin Epidemiol"},{"key":"46243_CR16","doi-asserted-by":"publisher","first-page":"151","DOI":"10.11613\/BM.2007.014","volume":"17","author":"MA Raslich","year":"2007","unstructured":"Raslich, M. A., Markert, R. J. & Stutes, S. A. Selecting and interpreting diagnostic tests. Biochem Med 17, 151\u2013161 (2007).","journal-title":"Biochem Med"},{"key":"46243_CR17","doi-asserted-by":"publisher","unstructured":"Legendre, P. Coefficient of concordance. (ed. Salkind, N. J.) 164\u2013169, https:\/\/doi.org\/10.4135\/9781412961288.n55 (SAGE Publications Inc., 2010).","DOI":"10.4135\/9781412961288.n55"}],"container-title":["Scientific Reports"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.nature.com\/articles\/s41598-019-46243-3.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.nature.com\/articles\/s41598-019-46243-3","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.nature.com\/articles\/s41598-019-46243-3.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2022,12,17]],"date-time":"2022-12-17T11:21:29Z","timestamp":1671276089000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.nature.com\/articles\/s41598-019-46243-3"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2019,7,9]]},"references-count":17,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2019,12]]}},"alternative-id":["46243"],"URL":"https:\/\/doi.org\/10.1038\/s41598-019-46243-3","relation":{},"ISSN":["2045-2322"],"issn-type":[{"value":"2045-2322","type":"electronic"}],"subject":[],"published":{"date-parts":[[2019,7,9]]},"assertion":[{"value":"22 March 2019","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"24 June 2019","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"9 July 2019","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"The authors declare no competing interests.","order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing Interests"}}],"article-number":"9912"}}