{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,11,20]],"date-time":"2026-11-20T04:44:57Z","timestamp":1795149897673,"version":"4.10.3"},"reference-count":37,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2019,10,11]],"date-time":"2019-10-11T00:00:00Z","timestamp":1570752000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2019,10,11]],"date-time":"2019-10-11T00:00:00Z","timestamp":1570752000000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"funder":[{"name":"KAKENH"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Sci Rep"],"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:p>\n                    Currently, surgical staples are composed of non\u2013biodegradable titanium (Ti) that can cause allergic reactions and interfere with imaging. This paper proposes a novel biodegradable magnesium (Mg) alloy staple and discusses analyses conducted to evaluate its safety and feasibility. Specifically, finite element analysis revealed that the proposed staple has a suitable stress distribution while stapling and maintaining closure. Further, an immersion test using artificial intestinal juice produced satisfactory biodegradable behavior, mechanical durability, and biocompatibility\n                    <jats:italic>in vitro<\/jats:italic>\n                    . Hydrogen resulting from rapid corrosion of Mg was observed in small quantities only in the first week of immersion, and most staples maintained their shapes until at least the fourth week. Further, the tensile force was maintained for more than a week and was reduced to approximately one-half by the fourth week. In addition, the Mg concentration of the intestinal artificial juice was at a low cytotoxic level. In porcine intestinal anastomoses, the Mg alloy staples caused neither technical failure nor such complications as anastomotic leakage, hematoma, or adhesion. No necrosis or serious inflammation reaction was histopathologically recognized. Thus, the proposed Mg alloy staple offers a promising alternative to Ti alloy\u00a0staples.\n                  <\/jats:p>","DOI":"10.1038\/s41598-019-51123-x","type":"journal-article","created":{"date-parts":[[2019,10,11]],"date-time":"2019-10-11T06:04:04Z","timestamp":1570773844000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":46,"title":["Biodegradable Surgical Staple Composed of Magnesium Alloy"],"prefix":"10.1038","volume":"9","author":[{"ORCID":"https:\/\/orcid.org\/0000-0001-5373-9069","authenticated-orcid":false,"given":"Hizuru","family":"Amano","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Kotaro","family":"Hanada","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Akinari","family":"Hinoki","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Takahisa","family":"Tainaka","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Chiyoe","family":"Shirota","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Wataru","family":"Sumida","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Kazuki","family":"Yokota","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Naruhiko","family":"Murase","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Kazuo","family":"Oshima","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Kosuke","family":"Chiba","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yujiro","family":"Tanaka","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-1818-6697","authenticated-orcid":false,"given":"Hiroo","family":"Uchida","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2019,10,11]]},"reference":[{"key":"51123_CR1","first-page":"Cd004320","volume":"9","author":"PY Choy","year":"2011","unstructured":"Choy, P. Y. et al. Stapled versus handsewn methods for ileocolic anastomoses. Cochrane Database Syst. Rev. 9, Cd004320 (2011).","journal-title":"Cochrane Database Syst. Rev."},{"key":"51123_CR2","doi-asserted-by":"crossref","unstructured":"Amano, H. et al. The impact of body weight on stapled anastomosis in pediatric patients. J. Pediatr. Surg. (2018).","DOI":"10.1016\/j.jpedsurg.2018.04.030"},{"issue":"9","key":"51123_CR3","doi-asserted-by":"publisher","first-page":"208","DOI":"10.4240\/wjgs.v4.i9.208","volume":"4","author":"F Goulder","year":"2012","unstructured":"Goulder, F. Bowel anastomoses: The theory, the practice and the evidence base. World J. Gastrointest. Surg. 4(9), 208\u2013213 (2012).","journal-title":"World J. Gastrointest. Surg."},{"issue":"5","key":"51123_CR4","doi-asserted-by":"publisher","first-page":"689","DOI":"10.1097\/00000658-197811000-00019","volume":"188","author":"JL Chassin","year":"1978","unstructured":"Chassin, J. L. et al. The stapled gastrointestinal tract anastomosis: Incidence of postoperative complications compared with the sutured anastomosis. Ann. Surg. 188(5), 689\u2013696 (1978).","journal-title":"Ann. Surg."},{"key":"51123_CR5","doi-asserted-by":"publisher","first-page":"90","DOI":"10.1186\/s13000-015-0291-3","volume":"10","author":"Y Nihon\u2013Yanagi","year":"2015","unstructured":"Nihon\u2013Yanagi, Y. et al. A case of postoperative hepatic granuloma presumptively caused by surgical staples\/clipping materials. Diag. Path. 10, 90 (2015).","journal-title":"Diag. Path."},{"issue":"2","key":"51123_CR6","first-page":"123","volume":"9","author":"M Tomita","year":"2003","unstructured":"Tomita, M. et al. Pulmonary granuloma possibly caused by staples after video\u2013assisted thoracoscopic surgery. Ann. Thorac. Cardiovasc. Surg. 9(2), 123\u2013125 (2003).","journal-title":"Ann. Thorac. Cardiovasc. Surg."},{"issue":"3","key":"51123_CR7","doi-asserted-by":"publisher","first-page":"563","DOI":"10.1016\/j.ejcts.2006.11.056","volume":"31","author":"M Yuksel","year":"2007","unstructured":"Yuksel, M., Akgul, A. G., Evman, S. & Batirel, H. F. Suture and stapler granulomas: A word of caution. Eur. J. Cardiothorac. Surg. 31(3), 563\u2013565 (2007).","journal-title":"Eur. J. Cardiothorac. Surg."},{"issue":"1","key":"51123_CR8","doi-asserted-by":"publisher","first-page":"90","DOI":"10.1007\/BF02967485","volume":"8","author":"K Tamai","year":"2001","unstructured":"Tamai, K. et al. A case of allergic reaction to surgical metal clips inserted for postoperative boost irradiation in a patient undergoing breast\u2013conserving therapy. Breast Cancer 8(1), 90\u201392 (2001).","journal-title":"Breast Cancer"},{"issue":"3","key":"51123_CR9","doi-asserted-by":"publisher","first-page":"1475","DOI":"10.1016\/j.actbio.2013.11.021","volume":"10","author":"PK Bowen","year":"2014","unstructured":"Bowen, P. K., Drelich, J. & Goldman, J. Magnesium in the murine artery: Probing the products of corrosion. Acta Biomaterialia 10(3), 1475\u20131483 (2014).","journal-title":"Acta Biomaterialia"},{"issue":"5","key":"51123_CR10","first-page":"667","volume":"28","author":"H Waizy","year":"2014","unstructured":"Waizy, H. et al. In vivo study of a biodegradable orthopedic screw (MgYREZr\u2013alloy) in a rabbit model for up to 12 months. J. Biomed. Appl. 28(5), 667\u2013675 (2014).","journal-title":"J. Biomed. Appl."},{"issue":"4","key":"51123_CR11","doi-asserted-by":"publisher","first-page":"484","DOI":"10.1016\/j.biomaterials.2008.10.021","volume":"30","author":"X Gu","year":"2009","unstructured":"Gu, X., Zheng, Y., Cheng, Y., Zhong, S. & Xi, T. In vitro corrosion and biocompatibility of binary magnesium alloys. Biomaterials 30(4), 484\u2013498 (2009).","journal-title":"Biomaterials"},{"key":"51123_CR12","doi-asserted-by":"publisher","DOI":"10.1186\/1475-925X-12-62","volume":"12","author":"H Windhagen","year":"2013","unstructured":"Windhagen, H. et al. Biodegradable magnesium\u2013based screw clinically equivalent to titanium screw in hallux valgus surgery: Short\u2013term results of the first prospective, randomized, controlled clinical pilot study. Biomed Eng. Online 12, 62 (2013).","journal-title":"Biomed Eng. Online"},{"issue":"2","key":"51123_CR13","doi-asserted-by":"publisher","first-page":"e160","DOI":"10.4244\/EIJ-D-15-00371","volume":"12","author":"M Haude","year":"2016","unstructured":"Haude, M. et al. Safety and performance of the DRug\u2013Eluting Absorbable Metal Scaffold (DREAMS) in patients with de novo coronary lesions: 3\u2013year results of the prospective, multicentre, first\u2013in\u2013man BIOSOLVE\u2013I trial. EuroIntervention 12(2), e160\u20136 (2016).","journal-title":"EuroIntervention"},{"issue":"4","key":"51123_CR14","doi-asserted-by":"publisher","first-page":"1177","DOI":"10.1007\/s11837-015-1773-1","volume":"68","author":"J\u2013M Seitz","year":"2016","unstructured":"Seitz, J. \u2013M., Lucas, A. & Kirschner, A. Magnesium\u2013based compression screws: A novelty in the clinical use of implants. JOM 68(4), 1177\u20131182 (2016).","journal-title":"JOM"},{"issue":"4","key":"51123_CR15","doi-asserted-by":"publisher","first-page":"432","DOI":"10.4244\/EIJV13I4A61","volume":"13","author":"M Haude","year":"2017","unstructured":"Haude, M. et al. Sustained safety and clinical performance of a drug\u2013eluting absorbable metal scaffold up to 24 months: Pooled outcomes of BIOSOLVE\u2013II and BIOSOLVE\u2013III. EuroIntervention 13(4), 432\u2013439 (2017).","journal-title":"EuroIntervention"},{"key":"51123_CR16","doi-asserted-by":"publisher","first-page":"1741","DOI":"10.1002\/jbm.b.34267","volume":"107","author":"H Bai","year":"2019","unstructured":"Bai, H. et al. Fabrication, microstructure, and properties of a biodegradable Mg-Zn-Ca clip. J Biomed. Mater. Res. Part B: Appl. Biomater. 107, 1741\u20131749 (2019).","journal-title":"J Biomed. Mater. Res. Part B: Appl. Biomater."},{"key":"51123_CR17","doi-asserted-by":"publisher","first-page":"468","DOI":"10.1016\/j.actbio.2015.10.023","volume":"29","author":"N Ikeo","year":"2016","unstructured":"Ikeo, N. et al. Fabrication of a magnesium alloy with excellent ductility for biodegradable clips. Acta Biomater. 29, 468\u2013476 (2016).","journal-title":"Acta Biomater."},{"key":"51123_CR18","doi-asserted-by":"publisher","first-page":"1553","DOI":"10.1016\/j.surg.2016.12.023","volume":"161","author":"T Yoshida","year":"2017","unstructured":"Yoshida, T. et al. Development of a new biodegradable operative clip made of a magnesium alloy: Evaluation of its safety and tolerability for canine cholecystectomy. Surgery 161, 1553\u20131560 (2017).","journal-title":"Surgery"},{"issue":"2","key":"51123_CR19","doi-asserted-by":"publisher","first-page":"122","DOI":"10.1016\/j.bioactmat.2016.09.005","volume":"1","author":"Hongliu Wu","year":"2016","unstructured":"Wu, H. et al. Research of a novel biodegradable surgical staple made of high purity magnesium. Bioact. Mater. 122\u2013126 (2016).","journal-title":"Bioactive Materials"},{"issue":"8","key":"51123_CR20","first-page":"1203","volume":"31","author":"S Qu","year":"2017","unstructured":"Qu, S. et al. In vivo and in vitro assessment of the biocompatibility and degradation of high\u2013purity Mg anastomotic staples. J. Biomed. Appl. 31(8), 1203\u20131214 (2017).","journal-title":"J. Biomed. Appl."},{"issue":"11","key":"51123_CR21","doi-asserted-by":"publisher","first-page":"9506","DOI":"10.1021\/acsami.7b00813","volume":"9","author":"J Xia","year":"2017","unstructured":"Xia, J. et al. High\u2013purity magnesium staples suppress inflammatory response in rectal anastomoses. ACS Appl. Mater. Int. 9(11), 9506\u20139515 (2017).","journal-title":"ACS Appl. Mater. Int."},{"issue":"9","key":"51123_CR22","doi-asserted-by":"publisher","first-page":"1059","DOI":"10.1016\/j.scriptamat.2005.07.001","volume":"53","author":"H Somekawa","year":"2005","unstructured":"Somekawa, H. & Mukai, T. Effect of grain refinement on fracture toughness in extruded pure magnesium. Scripta Materialia 53(9), 1059\u20131064 (2005).","journal-title":"Scripta Materialia"},{"issue":"24","key":"51123_CR23","doi-asserted-by":"publisher","first-page":"3947","DOI":"10.1016\/j.surfcoat.2010.03.015","volume":"204","author":"Y Zhang","year":"2010","unstructured":"Zhang, Y. et al. Effects of laser shock processing on stress corrosion cracking susceptibility of AZ31B magnesium alloy. Surf. Coat. Tech. 204(24), 3947\u20133953 (2010).","journal-title":"Surf. Coat. Tech."},{"issue":"1\u20132","key":"51123_CR24","doi-asserted-by":"publisher","first-page":"11","DOI":"10.1002\/adem.200900287","volume":"13","author":"A Atrens","year":"2011","unstructured":"Atrens, A., Winzer, N. & Dietzel, W. Stress corrosion cracking of magnesium alloys. Adv. Eng. Mater. 13(1\u20132), 11\u201318 (2011).","journal-title":"Adv. Eng. Mater."},{"key":"51123_CR25","doi-asserted-by":"publisher","first-page":"189","DOI":"10.1016\/j.procir.2013.01.038","volume":"5","author":"B Denkena","year":"2013","unstructured":"Denkena, B. et al. Influence of Stress on the Degradation Behavior of Mg LAE442 Implant Systems. Procedia CIRP 5, 189\u2013195 (2013).","journal-title":"Procedia CIRP"},{"issue":"2","key":"51123_CR26","doi-asserted-by":"publisher","first-page":"175","DOI":"10.1016\/j.scriptamat.2008.03.001","volume":"59","author":"MB Kannan","year":"2008","unstructured":"Kannan, M. B. & Raman, R. S. Evaluating the stress corrosion cracking susceptibility of Mg\u2013Al\u2013Zn alloy in modified\u2013simulated body fluid for orthopaedic implant application. Scripta Materialia 59(2), 175\u2013178 (2008).","journal-title":"Scripta Materialia"},{"issue":"10","key":"51123_CR27","doi-asserted-by":"publisher","first-page":"8714","DOI":"10.1016\/j.actbio.2012.10.008","volume":"9","author":"J Kuhlmann","year":"2013","unstructured":"Kuhlmann, J. et al. Fast escape of hydrogen from gas cavities around corroding magnesium implants. Acta Biomaterialia 9(10), 8714\u20138721 (2013).","journal-title":"Acta Biomaterialia"},{"key":"51123_CR28","unstructured":"Uchida, H., Hinoki, A. & Hanada, K. WIPO Patent No. WO2017061616 (2017)."},{"issue":"6","key":"51123_CR29","doi-asserted-by":"publisher","first-page":"849","DOI":"10.1007\/s00256-014-2057-5","volume":"44","author":"L Filli","year":"2015","unstructured":"Filli, L. et al. Metal-induced artifacts in computed tomography and magnetic resonance imaging: Comparison of a biodegradable magnesium alloy versus titanium and stainless steel controls. Skeletal Radiol. 44(6), 849\u2013856 (2015).","journal-title":"Skeletal Radiol."},{"issue":"5","key":"51123_CR30","doi-asserted-by":"publisher","first-page":"63","DOI":"10.1016\/j.cossms.2009.04.001","volume":"12","author":"F Witte","year":"2008","unstructured":"Witte, F. et al. Degradable biomaterials based on magnesium corrosion. Curr. Opin. Solid St. M. 12(5), 63\u201372 (2008).","journal-title":"Curr. Opin. Solid St. M."},{"key":"51123_CR31","doi-asserted-by":"publisher","DOI":"10.1186\/s40064-015-0922-x","volume":"4","author":"MB Christensen","year":"2015","unstructured":"Christensen, M. B., Oberg, K. & Wolchok, J. C. Tensile properties of the rectal and sigmoid colon: A comparative analysis of human and porcine tissue. SpringerPlus 4, 142 (2015).","journal-title":"SpringerPlus"},{"issue":"5","key":"51123_CR32","doi-asserted-by":"publisher","first-page":"1693","DOI":"10.1016\/j.actbio.2009.10.006","volume":"6","author":"H Hermawan","year":"2010","unstructured":"Hermawan, H., Dube, D. & Mantovani, D. Developments in metallic biodegradable stents. Acta Biomaterialia 6(5), 1693\u20131697 (2010).","journal-title":"Acta Biomaterialia"},{"key":"51123_CR33","unstructured":"Coated VICRYL\u00ae (polyglactin 910) Suture IFU. https:\/\/hostedvl106.quosavl.com\/qb\/, (accessed 7 September 2018)."},{"key":"51123_CR34","unstructured":"ISO Standard 10993-5:2009, Biological evaluation of medical devices\u2013Part 5: Tests for in vitro cytotoxicity, International Organization for Standardization (2009)."},{"key":"51123_CR35","doi-asserted-by":"publisher","first-page":"3760","DOI":"10.1016\/S1003-6326(15)64014-6","volume":"25","author":"S Yu","year":"2015","unstructured":"Yu, S. et al. In vitro and in vivo evaluation of effects of Mg\u20136Zn alloy on tight junction of intestinal epithelial cell. Trans. Nonferrous Met. Soc. China 25, 3760\u20133766 (2015).","journal-title":"Trans. Nonferrous Met. Soc. China"},{"key":"51123_CR36","unstructured":"Shiozaki, Y. The Japanese Pharmacopoeia, 17th Edition, The Ministry of Health, Labour and Welfare https:\/\/www.mhlw.go.jp\/file\/06-Seisakujouhou-11120000-Iyakushokuhinkyoku\/JP17_REV_1.pdf, 2016 (accessed 7 September 2018)."},{"key":"51123_CR37","unstructured":"ASTM\u2013E8\u201304. Standard Test Methods for Tension Testing of Metallic Materials, Annual Book of ASTM standards, Philadelphia, Pennsylvania, USA (2004)."}],"container-title":["Scientific Reports"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.nature.com\/articles\/s41598-019-51123-x.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.nature.com\/articles\/s41598-019-51123-x","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.nature.com\/articles\/s41598-019-51123-x.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2022,12,17]],"date-time":"2022-12-17T09:28:33Z","timestamp":1671269313000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.nature.com\/articles\/s41598-019-51123-x"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2019,10,11]]},"references-count":37,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2019,12]]}},"alternative-id":["51123"],"URL":"https:\/\/doi.org\/10.1038\/s41598-019-51123-x","relation":{},"ISSN":["2045-2322"],"issn-type":[{"value":"2045-2322","type":"electronic"}],"subject":[],"published":{"date-parts":[[2019,10,11]]},"assertion":[{"value":"11 February 2019","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"25 September 2019","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"11 October 2019","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"The authors declare no competing interests.","order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing Interests"}}],"article-number":"14671"}}