{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,2,6]],"date-time":"2026-02-06T22:02:20Z","timestamp":1770415340901,"version":"3.49.0"},"reference-count":23,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2019,10,22]],"date-time":"2019-10-22T00:00:00Z","timestamp":1571702400000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2019,10,22]],"date-time":"2019-10-22T00:00:00Z","timestamp":1571702400000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"funder":[{"DOI":"10.13039\/501100001834","name":"University of Twente","doi-asserted-by":"publisher","id":[{"id":"10.13039\/501100001834","id-type":"DOI","asserted-by":"publisher"}]},{"name":"Pioneers in Healthcare Innovation Fund"},{"DOI":"10.13039\/501100003246","name":"Nederlandse Organisatie voor Wetenschappelijk Onderzoek","doi-asserted-by":"publisher","award":["VENI-13615"],"award-info":[{"award-number":["VENI-13615"]}],"id":[{"id":"10.13039\/501100003246","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Sci Rep"],"abstract":"<jats:title>Abstract<\/jats:title><jats:p>The non-invasive quantification of total haemoglobin concentrations [tHb] is highly desired for the assessment of haematologic disorders in vulnerable patient groups, but invasive blood sampling is still the gold standard in current clinical practice. This work demonstrates the potential of visible-light spectroscopic optical coherence tomography (sOCT) for quantifying the [tHb] in human whole blood. To accurately quantify the [tHb] from the substantial optical attenuation by blood in the visible wavelength range, we used a combination of zero-delay acquisition and focus tracking that ensures optimal system sensitivity at any depth inside the sample. Subsequently, we developed an analysis model to adequately correct for the high scattering contribution by red blood cells to the sOCT signal. We validate our method and compare it to conventional sOCT (without focus tracking and zero-delay acquisition) through <jats:italic>ex-vivo<\/jats:italic> measurements on flowing human whole blood, with [tHb] values in the clinical range of 7\u201323\u2009g\/dL. For our method with optimized sensitivity, the measured and expected values correlate well (Pearson correlation coefficient\u2009=\u20090.89, p\u2009&lt;\u20090.01), with a precision of 3.8\u2009g\/dL. This is a considerable improvement compared to conventional sOCT (Pearson correlation coefficient\u2009=\u20090.59, p\u2009=\u20090.16; precision of 9.1\u2009g\/dL).<\/jats:p>","DOI":"10.1038\/s41598-019-51721-9","type":"journal-article","created":{"date-parts":[[2019,10,23]],"date-time":"2019-10-23T04:26:13Z","timestamp":1571804773000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":23,"title":["Quantification of total haemoglobin concentrations in human whole blood by spectroscopic visible-light optical coherence tomography"],"prefix":"10.1038","volume":"9","author":[{"given":"Colin","family":"Veenstra","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Saskia","family":"Kruitwagen","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Dafne","family":"Groener","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Wilma","family":"Petersen","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Wiendelt","family":"Steenbergen","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Nienke","family":"Bosschaart","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2019,10,22]]},"reference":[{"key":"51721_CR1","unstructured":"World Health Organization. Haemoglobin concentrations for the diagnosis of anaemia and assessment of severity. at https:\/\/www.who.int\/vmnis\/indicators\/haemoglobin\/en\/ (2011)."},{"key":"51721_CR2","doi-asserted-by":"crossref","unstructured":"Jeon, K. J., Kim, S. & Park, K. K. Noninvasive total hemoglobin measurement. J. Biomed. Opt., 45\u201350 (2002).","DOI":"10.1117\/1.1427047"},{"key":"51721_CR3","doi-asserted-by":"publisher","first-page":"117","DOI":"10.1111\/tme.12525","volume":"28","author":"GL Crighton","year":"2018","unstructured":"Crighton, G. L., New, H. V., Liley, H. G. & Stanworth, S. J. Patient blood management, what does this actually mean for neonates and infants? Transfus. Med. 28, 117\u2013131 (2018).","journal-title":"Transfus. Med."},{"key":"51721_CR4","doi-asserted-by":"publisher","first-page":"972","DOI":"10.1213\/ANE.0b013e318233041a","volume":"114","author":"MY Shamir","year":"2012","unstructured":"Shamir, M. Y., Avramovich, A. & Smaka, T. The current status of continuous noninvasive measurement of total, carboxy, and methemoglobin concentration. Anesth. Analg. 114, 972\u2013978 (2012).","journal-title":"Anesth. Analg."},{"key":"51721_CR5","doi-asserted-by":"crossref","unstructured":"Saerchen, E. et al. Focused, wide-band, polymer-based optoacoustic transducers for noninvasive monitoring of total hemoglobin concentration and other blood variables. Proc. SPIE 7899, Photons Plus Ultrasound: Imaging and Sensing. 78994E (2011).","DOI":"10.1117\/12.879490"},{"key":"51721_CR6","doi-asserted-by":"crossref","unstructured":"Bosschaart, N., Faber, D. J., Leeuwen, T. G. & Aalders, M. C. In vivo low-coherence spectroscopic measurements of local hemoglobin absorption spectra in human skin. J. Biomed. Opt., 100504 (2011).","DOI":"10.1117\/1.3644497"},{"key":"51721_CR7","doi-asserted-by":"publisher","first-page":"2056","DOI":"10.1364\/BOE.9.002056","volume":"9","author":"S Pi","year":"2018","unstructured":"Pi, S. et al. Automated spectroscopic retinal oximetry with visible-light optical coherence tomography. Biomed. Opt. Express 9, 2056\u20132067 (2018).","journal-title":"Biomed. Opt. Express"},{"key":"51721_CR8","doi-asserted-by":"publisher","first-page":"1429","DOI":"10.1364\/BOE.6.001429","volume":"6","author":"SP Chong","year":"2015","unstructured":"Chong, S. P., Merkle, C. W., Leahy, C., Radhakrishnan, H. & Srinivasan, V. J. Quantitative microvascular hemoglobin mapping using visible light spectroscopic Optical Coherence Tomography. Biomed. Opt. Express 6, 1429\u20131450 (2015).","journal-title":"Biomed. Opt. Express"},{"key":"51721_CR9","doi-asserted-by":"crossref","unstructured":"Yi, J. & Li, X. Estimation of oxygen saturation from erythrocytes by high resolution spectroscopic optical coherence tomography. Opt. Lett., 2094\u20132096 (2010).","DOI":"10.1364\/OL.35.002094"},{"key":"51721_CR10","doi-asserted-by":"publisher","first-page":"3603","DOI":"10.1364\/BOE.5.003603","volume":"5","author":"J Yi","year":"2014","unstructured":"Yi, J., Chen, S., Backman, V. & Zhang, H. F. In vivo functional microangiography by visible-light optical coherence tomography. Biomed. Opt. Express 5, 3603\u20133612 (2014).","journal-title":"Biomed. Opt. Express"},{"key":"51721_CR11","doi-asserted-by":"publisher","first-page":"2840","DOI":"10.1364\/BOE.6.002840","volume":"6","author":"S Chen","year":"2015","unstructured":"Chen, S., Yi, J. & Zhang, H. F. Measuring oxygen saturation in retinal and choroidal circulations in rats using visible light optical coherence tomography angiography. Biomed. Opt. Express 6, 2840\u20132853 (2015).","journal-title":"Biomed. Opt. Express"},{"key":"51721_CR12","doi-asserted-by":"publisher","DOI":"10.1038\/lsa.2015.107","volume":"4","author":"J Yi","year":"2015","unstructured":"Yi, J. et al. Visible light optical coherence tomography measures retinal oxygen metabolic response to systemic oxygenation. Light Sci. Appl. 4, e334 (2015).","journal-title":"Light Sci. Appl."},{"key":"51721_CR13","doi-asserted-by":"publisher","first-page":"3581","DOI":"10.1364\/BOE.9.003581","volume":"9","author":"C Veenstra","year":"2018","unstructured":"Veenstra, C., Petersen, W., Vellekoop, I. M., Steenbergen, W. & Bosschaart, N. Spatially confined quantification of bilirubin concentrations by spectroscopic visible-light optical coherence tomography. Biomed. Opt. Express 9, 3581\u20133589 (2018).","journal-title":"Biomed. Opt. Express"},{"key":"51721_CR14","doi-asserted-by":"publisher","first-page":"310","DOI":"10.1364\/BOE.1.000310","volume":"1","author":"FE Robles","year":"2010","unstructured":"Robles, F. E., Chowdhury, S. & Wax, A. Assessing hemoglobin concentration using spectroscopic optical coherence tomography for feasibility of tissue diagnostics. Biomed. Opt. Express 1, 310\u2013317 (2010).","journal-title":"Biomed. Opt. Express"},{"key":"51721_CR15","doi-asserted-by":"publisher","first-page":"361","DOI":"10.1089\/15270290152608534","volume":"2","author":"R V\u00e1squez","year":"2001","unstructured":"V\u00e1squez, R. & Villena, M. Normal hematological values for healthy persons living at 4000 meters in Bolivia. High alt. med. biol. 2, 361\u2013367 (2001).","journal-title":"High alt. med. biol."},{"key":"51721_CR16","doi-asserted-by":"publisher","first-page":"2263","DOI":"10.1364\/BOE.3.002263","volume":"3","author":"N Bosschaart","year":"2012","unstructured":"Bosschaart, N., Aalders, M. C. G., van Leeuwen, T. G. & Faber, D. J. Spectral domain detection in low-coherence spectroscopy. Biomed Opt Express 3, 2263\u20132272 (2012).","journal-title":"Biomed Opt Express"},{"key":"51721_CR17","doi-asserted-by":"publisher","first-page":"121314","DOI":"10.1117\/1.JBO.20.12.121314","volume":"20","author":"M Almasian","year":"2015","unstructured":"Almasian, M., Bosschaart, N., van Leeuwen, T. G. & Faber, D. J. Validation of quantitative attenuation and backscattering coefficient measurements by optical coherence tomography in the concentration-dependent and multiple scattering regime. J. Biomed. Opt. 20, 121314 (2015).","journal-title":"J. Biomed. Opt."},{"key":"51721_CR18","doi-asserted-by":"publisher","first-page":"453","DOI":"10.1007\/s10103-013-1446-7","volume":"29","author":"N Bosschaart","year":"2014","unstructured":"Bosschaart, N., Edelman, G. J., Aalders, M. C., van Leeuwen, T. G. & Faber, D. J. A literature review and novel theoretical approach on the optical properties of whole blood. Lasers Med. Sci. 29, 453\u2013479 (2014).","journal-title":"Lasers Med. Sci."},{"key":"51721_CR19","doi-asserted-by":"publisher","first-page":"3746","DOI":"10.1364\/OL.34.003746","volume":"34","author":"N Bosschaart","year":"2009","unstructured":"Bosschaart, N. et al. Quantitative measurements of absorption spectra in scattering media by low-coherence spectroscopy. Opt. Lett. 34, 3746\u20133748 (2009).","journal-title":"Opt. Lett."},{"key":"51721_CR20","unstructured":"Baskurt, O. K., Hardeman, M. R. & Rampling, M. W. Handbook of Hemorheology and Hemodynamics. (IOS Press, 2007)."},{"key":"51721_CR21","doi-asserted-by":"publisher","first-page":"042312","DOI":"10.1103\/PhysRevE.88.042312","volume":"88","author":"N Weiss","year":"2013","unstructured":"Weiss, N., van Leeuwen, T. G. & Kalkman, J. Localized measurement of longitudinal and transverse flow velocities in colloidal suspensions using optical coherence tomography. Phys. Rev. E 88, 042312 (2013).","journal-title":"Phys. Rev. E"},{"key":"51721_CR22","doi-asserted-by":"publisher","first-page":"3598","DOI":"10.1364\/OE.11.003598","volume":"11","author":"SH Yun","year":"2003","unstructured":"Yun, S. H., Tearney, G. J., Bouma, B. E., Park, B. H. & de Boer, J. F. High-speed spectral-domain optical coherence tomography at 1.3 mu m wavelength. Opt Express 11, 3598\u20133604 (2003).","journal-title":"Opt Express"},{"key":"51721_CR23","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1016\/0006-3002(56)90380-8","volume":"19","author":"LNM Duyens","year":"1956","unstructured":"Duyens, L. N. M. The flattering of the absorption spectrum of suspensions, as compared to that of solutions. Biochim. Biophys. Acta 19, 1\u201312 (1956).","journal-title":"Biochim. Biophys. Acta"}],"container-title":["Scientific Reports"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.nature.com\/articles\/s41598-019-51721-9.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.nature.com\/articles\/s41598-019-51721-9","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.nature.com\/articles\/s41598-019-51721-9.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2022,12,17]],"date-time":"2022-12-17T14:57:26Z","timestamp":1671289046000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.nature.com\/articles\/s41598-019-51721-9"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2019,10,22]]},"references-count":23,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2019,12]]}},"alternative-id":["51721"],"URL":"https:\/\/doi.org\/10.1038\/s41598-019-51721-9","relation":{},"ISSN":["2045-2322"],"issn-type":[{"value":"2045-2322","type":"electronic"}],"subject":[],"published":{"date-parts":[[2019,10,22]]},"assertion":[{"value":"12 July 2019","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"2 October 2019","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"22 October 2019","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"The authors declare no competing interests.","order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"15115"}}