{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,11,10]],"date-time":"2026-11-10T14:18:30Z","timestamp":1794320310794,"version":"4.9.0"},"reference-count":29,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2019,11,4]],"date-time":"2019-11-04T00:00:00Z","timestamp":1572825600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2019,11,4]],"date-time":"2019-11-04T00:00:00Z","timestamp":1572825600000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Sci Rep"],"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:p>\n                    In this third-generation dual-source CT (DSCT) study, we retrospectively investigated radiation dose and image quality of portal-venous high-pitch emergency CT in 60 patients (28 female, mean age 56 years) with a body mass index (BMI) \u2265\u00a030\u2009kg\/m\n                    <jats:sup>2<\/jats:sup>\n                    . Patients were dichotomized in groups A (median BMI 31.5\u2009kg\/m\n                    <jats:sup>2<\/jats:sup>\n                    ; n\u2009=\u200933) and B (36.8\u2009kg\/m\n                    <jats:sup>2<\/jats:sup>\n                    ; n\u2009=\u200927). Volumetric CT dose index (CTDI\n                    <jats:sub>vol<\/jats:sub>\n                    ), size-specific dose estimate (SSDE), dose length product (DLP) and effective dose (ED) were assessed. Contrast-to-noise ratio (CNR) and dose-independent figure-of-merit (FOM) CNR were calculated. Subjective image quality was assessed using a five-point scale. Mean values of CTDI\n                    <jats:sub>vol<\/jats:sub>\n                    , SSDE as well as normalized DLP and ED were 7.6\u2009\u00b1\u20091.8 mGy, 8.0\u2009\u00b1\u20091.8 mGy, 304\u2009\u00b1\u200974 mGy\u2009*\u2009cm and 5.2\u2009\u00b1\u20091.3\u2009mSv for group A, and 12.6\u2009\u00b1\u20093.7 mGy, 11.0\u2009\u00b1\u20092.6 mGy, 521\u2009\u00b1\u2009157 mGy\u2009*\u2009cm and 8.9\u2009\u00b1\u20092.7\u2009mSv for group B (p\u2009&lt;\u20090.001). CNR of the liver and spleen as well as each calculated FOM CNR were significantly higher in group A (p\u2009&lt;\u20090.001). Subjective image quality was good in both groups. In conclusion, third-generation abdominal high-pitch emergency DSCT yields good image quality in obese patients. Radiation dose increases in patients with a BMI &gt;\u00a036.8\u2009kg\/m\n                    <jats:sup>2<\/jats:sup>\n                    .\n                  <\/jats:p>","DOI":"10.1038\/s41598-019-52454-5","type":"journal-article","created":{"date-parts":[[2019,11,4]],"date-time":"2019-11-04T06:03:55Z","timestamp":1572847435000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":17,"title":["Radiation dose and image quality of high-pitch emergency abdominal CT in obese patients using third-generation dual-source CT (DSCT)"],"prefix":"10.1038","volume":"9","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-1054-1463","authenticated-orcid":false,"given":"Robert","family":"Forbrig","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Michael","family":"Ingrisch","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Robert","family":"Stahl","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Katharina Stella","family":"Winter","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Maximilian","family":"Reiser","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Christoph G.","family":"Trumm","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2019,11,4]]},"reference":[{"key":"52454_CR1","doi-asserted-by":"publisher","first-page":"571","DOI":"10.1016\/j.gtc.2016.07.012","volume":"45","author":"C Arroyo-Johnson","year":"2016","unstructured":"Arroyo-Johnson, C. & Mincey, K. D. Obesity Epidemiology Worldwide. Gastroenterol Clin North Am. 45, 571\u2013579 (2016).","journal-title":"Gastroenterol Clin North Am."},{"key":"52454_CR2","doi-asserted-by":"publisher","first-page":"295","DOI":"10.1016\/j.jemermed.2015.07.023","volume":"50","author":"SD Siadecki","year":"2016","unstructured":"Siadecki, S. D., Frasure, S. E., Lewiss, R. E. & Saul, T. High Body Mass Index is Strongly Correlated with Decreased Image Quality in Focused Bedside Echocardiography. J Emerg Med. 50, 295\u2013301 (2016).","journal-title":"J Emerg Med."},{"key":"52454_CR3","doi-asserted-by":"publisher","first-page":"366","DOI":"10.1007\/s00117-010-2087-5","volume":"51","author":"F Bamberg","year":"2011","unstructured":"Bamberg, F. et al. Challenges for computed tomography of overweight patients [Article in German]. Radiologe. 51, 366\u2013371 (2011).","journal-title":"Radiologe."},{"key":"52454_CR4","doi-asserted-by":"publisher","first-page":"2549","DOI":"10.1038\/oby.2008.410","volume":"16","author":"AA Ginde","year":"2008","unstructured":"Ginde, A. A., Foianini, A., Renner, D. M., Valley, M. & Camargo, C. A. Jr. The challenge of CT and MRI imaging of obese individuals who present to the emergency department: a national survey. Obesity (Silver Spring). 16, 2549\u20132551 (2008).","journal-title":"Obesity (Silver Spring)."},{"key":"52454_CR5","unstructured":"Siemens Healthineers. SOMATOM Force. Siemens Healthineers, Erlangen, https:\/\/www.healthcare.siemens.de\/computed-tomography\/dual-source-ct\/somatom-force (2018)."},{"key":"52454_CR6","doi-asserted-by":"publisher","first-page":"362","DOI":"10.1016\/j.ejrad.2008.08.013","volume":"68","author":"M Petersilka","year":"2008","unstructured":"Petersilka, M., Bruder, H., Krauss, B., Stierstorfer, K. & Flohr, T. G. Technical principles of dual source CT. Eur J Radiol. 68, 362\u2013368 (2008).","journal-title":"Eur J Radiol."},{"key":"52454_CR7","doi-asserted-by":"publisher","first-page":"1643","DOI":"10.1007\/s00330-014-3194-x","volume":"24","author":"FG Meinel","year":"2014","unstructured":"Meinel, F. G. et al. Image quality and radiation dose of low tube voltage 3rd generation dual-source coronary CT angiography in obese patients: a phantom study. Eur Radiol. 24, 1643\u20131650 (2014).","journal-title":"Eur Radiol."},{"key":"52454_CR8","doi-asserted-by":"publisher","first-page":"e0211097","DOI":"10.1371\/journal.pone.0211097","volume":"14","author":"HK Lim","year":"2019","unstructured":"Lim, H. K., Ha, H. I., Hwang, H. J. & Lee, K. High-pitch, 120 kVp\/30 mAs, low-dose dual-source chest CT with iterative reconstruction: Prospective evaluation of radiation dose reduction and image quality compared with those of standard-pitch low-dose chest CT in healthy adult volunteers. PLoS One. 14, e0211097 (2019).","journal-title":"PLoS One."},{"key":"52454_CR9","doi-asserted-by":"publisher","first-page":"20170443","DOI":"10.1259\/bjr.20170443","volume":"91","author":"J Gariani","year":"2018","unstructured":"Gariani, J., Martin, S. P., Botsikas, D., Becker, C. D. & Montet, X. Evaluating the effect of increased pitch, iterative reconstruction and dual source CT on dose reduction and image quality. Br J Radiol. 91, 20170443 (2018).","journal-title":"Br J Radiol."},{"key":"52454_CR10","doi-asserted-by":"publisher","first-page":"e392","DOI":"10.1016\/j.ejrad.2011.12.017","volume":"81","author":"NA Amacker","year":"2012","unstructured":"Amacker, N. A., Mader, C., Alkadhi, H., Leschka, S. & Frauenfelder, T. Routine chest and abdominal high-pitch CT: an alternative low dose protocol with preserved image quality. Eur J Radiol. 81, e392\u2013397 (2012).","journal-title":"Eur J Radiol."},{"key":"52454_CR11","doi-asserted-by":"publisher","first-page":"353","DOI":"10.1097\/RCT.0b013e31821a02c8","volume":"35","author":"AD Hardie","year":"2011","unstructured":"Hardie, A. D., Mayes, N. & Boulter, D. J. Use of high-pitch dual-source computed tomography of the abdomen and pelvis to markedly reduce scan time: clinical feasibility study. J Comput Assist Tomogr. 35, 353\u2013355 (2011).","journal-title":"J Comput Assist Tomogr."},{"key":"52454_CR12","doi-asserted-by":"publisher","first-page":"e0146949","DOI":"10.1371\/journal.pone.0146949","volume":"11","author":"BO Sabel","year":"2016","unstructured":"Sabel, B. O. et al. High-Pitch CT Pulmonary Angiography in Third Generation Dual-Source CT: Image Quality in an Unselected Patient Population. PLoS One. 11, e0146949 (2016).","journal-title":"PLoS One."},{"key":"52454_CR13","first-page":"117","volume":"3","author":"S Achenbach","year":"2009","unstructured":"Achenbach, S. et al. High-pitch spiral acquisition: a new scan mode for coronary CT angiography. J Cardiovasc. Comput Tomogr. 3, 117\u2013121 (2009).","journal-title":"Comput Tomogr."},{"key":"52454_CR14","doi-asserted-by":"publisher","first-page":"543","DOI":"10.1097\/RCT.0b013e318291f6a0","volume":"37","author":"CN De Cecco","year":"2013","unstructured":"De Cecco, C. N. et al. Second-generation dual-energy computed tomography of the abdomen: radiation dose comparison with 64- and 128-row single-energy acquisition. Comput Assist Tomogr. 37, 543\u2013546 (2013).","journal-title":"Comput Assist Tomogr."},{"key":"52454_CR15","doi-asserted-by":"publisher","first-page":"642","DOI":"10.1007\/s00330-016-4383-6","volume":"27","author":"JL Wichmann","year":"2017","unstructured":"Wichmann, J. L. et al. Single- and dual-energy CT of the abdomen: comparison of radiation dose and image quality of 2nd and 3rd generation dual-source CT. Eur Radiol. 27, 642\u2013650 (2017).","journal-title":"Eur Radiol."},{"key":"52454_CR16","doi-asserted-by":"publisher","first-page":"167","DOI":"10.1148\/radiol.2015141507","volume":"279","author":"JV Spearman","year":"2016","unstructured":"Spearman, J. V. et al. Effect of Automated Attenuation-based Tube Voltage Selection on Radiation Dose at CT: An Observational Study on a Global Scale. Radiology. 279, 167\u2013174 (2016).","journal-title":"Radiology."},{"key":"52454_CR17","doi-asserted-by":"publisher","first-page":"2346","DOI":"10.1007\/s00330-015-3632-4","volume":"25","author":"A Winklehner","year":"2015","unstructured":"Winklehner, A. et al. Automated attenuation-based tube voltage selection for body CTA: Performance evaluation of 192-slice dual-source CT. Eur Radiol. 25, 2346\u20132353 (2015).","journal-title":"Eur Radiol."},{"key":"52454_CR18","unstructured":"Menzel, H., Schibilla, H., Teunen, D. eds. European Guidelines on Quality Criteria for Computed Tomography. Publication EUR 16262 EN. Luxembourg: European Commission. 735\u2013738 (2000)."},{"key":"52454_CR19","doi-asserted-by":"publisher","first-page":"881","DOI":"10.2214\/AJR.09.3462","volume":"194","author":"JA Christner","year":"2010","unstructured":"Christner, J. A., Kofler, J. M. & McCollough, C. H. Estimating effective dose for CT using dose-length product compared with using organ doses: consequences of adopting international commission on radiological protection publication 103 or dual-energy scanning. Am J Roentgenol. 194, 881\u2013889 (2010).","journal-title":"Am J Roentgenol."},{"key":"52454_CR20","doi-asserted-by":"publisher","first-page":"841","DOI":"10.1148\/radiol.12112365","volume":"265","author":"JA Christner","year":"2012","unstructured":"Christner, J. A. et al. Size-specific dose estimates for adult patients at CT of the torso. Radiology. 265, 841\u2013847 (2012).","journal-title":"Radiology."},{"key":"52454_CR21","doi-asserted-by":"publisher","first-page":"6550","DOI":"10.1118\/1.4754584","volume":"39","author":"X Li","year":"2012","unstructured":"Li, X. et al. Effects of protocol and obesity on dose conversion factors in adult body CT. Med Phys. 39, 6550\u20136571 (2012).","journal-title":"Med Phys."},{"key":"52454_CR22","doi-asserted-by":"crossref","unstructured":"Boone, J., Strauss, K. & Cody, D. Size-specific dose estimates (SSDE) in pediatric and adult body CT examinations. Report of AAPM Task Group 204 (2011).","DOI":"10.37206\/143"},{"key":"52454_CR23","doi-asserted-by":"publisher","first-page":"125","DOI":"10.1148\/radiol.2461070307","volume":"246","author":"ST Schindera","year":"2008","unstructured":"Schindera, S. T. et al. Hypervascular liver tumors: low tube voltage, high tube current multi-detector row CT for enhanced detection\u2013phantom study. Radiology. 246, 125\u2013132 (2008).","journal-title":"Radiology."},{"key":"52454_CR24","doi-asserted-by":"publisher","first-page":"467","DOI":"10.1148\/radiol.11110021","volume":"261","author":"T Nakaura","year":"2011","unstructured":"Nakaura, T. et al. Abdominal dynamic CT in patients with renal dysfunction: contrast agent dose reduction with low tube voltage and high tube current-time product settings at 256-detector row CT. Radiology. 261, 467\u2013476 (2011).","journal-title":"Radiology."},{"key":"52454_CR25","doi-asserted-by":"publisher","first-page":"732","DOI":"10.1148\/radiol.10092016","volume":"257","author":"LS Guimaraes","year":"2010","unstructured":"Guimaraes, L. S. et al. Appropriate patient selection at abdominal dual-energy CT using 80 kV: relationship between patient size, image noise, and image quality. Radiology. 257, 732\u2013742 (2010).","journal-title":"Radiology."},{"key":"52454_CR26","doi-asserted-by":"publisher","first-page":"3260","DOI":"10.1007\/s00330-014-3365-9","volume":"24","author":"GM Lu","year":"2014","unstructured":"Lu, G. M. et al. High-pitch computed tomography pulmonary angiography with iterative reconstruction at 80 kVp and 20 mL contrast agent volume. Eur Radiol. 24, 3260\u20133268 (2014).","journal-title":"Eur Radiol."},{"key":"52454_CR27","doi-asserted-by":"publisher","first-page":"279","DOI":"10.1007\/s00330-011-2251-y","volume":"22","author":"T De Zordo","year":"2012","unstructured":"De Zordo, T. et al. Comparison of image quality and radiation dose of different pulmonary CTA protocols on a 128-slice CT: high-pitch dual source CT, dual energy CT and conventional spiral CT. Eur Radiol. 22, 279\u2013286 (2012).","journal-title":"Eur Radiol."},{"key":"52454_CR28","doi-asserted-by":"publisher","first-page":"2441","DOI":"10.1088\/0031-9155\/57\/9\/2441","volume":"57","author":"A Ding","year":"2012","unstructured":"Ding, A., Mille, M. M., Liu, T., Caracappa, P. F. & Xu, X. G. Extension of RPI-adult male and female computational phantoms to obese patients and a Monte Carlo study of the effect on CT imaging dose. Phys Med Biol. 57, 2441\u201359 (2012).","journal-title":"Phys Med Biol."},{"key":"52454_CR29","unstructured":"Federal Office for Radiation Protection. Publication of updated diagnostic reference levels for diagnostic and interventional X-ray examinations [Article in German]. Federal Office for Radiation Protection, Berlin, http:\/\/www.bfs.de\/SharedDocs\/Downloads\/BfS\/DE\/fachinfo\/ion\/drw-roentgen.pdf?__blob=publicationFile&v=9 (2016)."}],"container-title":["Scientific Reports"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.nature.com\/articles\/s41598-019-52454-5.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.nature.com\/articles\/s41598-019-52454-5","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.nature.com\/articles\/s41598-019-52454-5.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2022,12,17]],"date-time":"2022-12-17T10:26:37Z","timestamp":1671272797000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.nature.com\/articles\/s41598-019-52454-5"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2019,11,4]]},"references-count":29,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2019,12]]}},"alternative-id":["52454"],"URL":"https:\/\/doi.org\/10.1038\/s41598-019-52454-5","relation":{},"ISSN":["2045-2322"],"issn-type":[{"value":"2045-2322","type":"electronic"}],"subject":[],"published":{"date-parts":[[2019,11,4]]},"assertion":[{"value":"9 January 2019","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"17 October 2019","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"4 November 2019","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"The authors declare no competing interests.","order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"15877"}}