{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,29]],"date-time":"2026-10-29T01:07:02Z","timestamp":1793236022727,"version":"4.5.0"},"reference-count":50,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2019,11,28]],"date-time":"2019-11-28T00:00:00Z","timestamp":1574899200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2019,11,28]],"date-time":"2019-11-28T00:00:00Z","timestamp":1574899200000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Sci Rep"],"abstract":"<jats:title>Abstract<\/jats:title><jats:p>EEG-based technologies may be limited in identifying recall under sedation (RUS). We developed a novel index, posteriorization\/anteriorization (P\/A) index, based on auditory evoked EEG signal and assessed whether it could differentiate between patients with or without RUS. Methods: EEG and BIS were sampled from 3 groups: 1. Patients undergoing sedation (n\u2009=\u200926); 2. Awake volunteers (n\u2009=\u200913, positive control for recall) 3. Patients undergoing general anesthesia (GA, n\u2009=\u200912, negative control for recall). In recovery, recall was assessed using the BRICE questionnaire. Of the 26 sedated patients, 12 experienced recall. Both The P\/A index and BIS differentiated between patients with recall and no recall. However, BIS differentiation may have been sensitive to the main drug used for sedation (midazolam vs. propofol) and the P\/A index did not show similar drug-based sensitivity. Furthermore, only BIS results were correlated with EMG. Conclusion: This pilot study provided support for the association between P\/A index and recall after sedation. Further research is needed in integrating the index into clinical use: (1) it should be derived by an easy-to-use EEG system with a better signal-to-noise ratio; (2) its applicability to other drugs must be shown.<\/jats:p>","DOI":"10.1038\/s41598-019-54270-3","type":"journal-article","created":{"date-parts":[[2019,11,28]],"date-time":"2019-11-28T11:03:21Z","timestamp":1574939001000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":5,"title":["A New Index of Coordinated Posterior and Anterior Evoked EEG to Detect Recall Under Sedation \u2013 A Pilot Study"],"prefix":"10.1038","volume":"9","author":[{"given":"Dana","family":"Baron Shahaf","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Gregory M. T.","family":"Hare","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Andrew J.","family":"Baker","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Violina","family":"Chenosia","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Leonid","family":"Priven","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Nikhil","family":"Mistry","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Goded","family":"Shahaf","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2019,11,28]]},"reference":[{"key":"54270_CR1","doi-asserted-by":"publisher","first-page":"848","DOI":"10.1136\/bjsports-2016-097466","volume":"51","author":"RJ Echemendia","year":"2017","unstructured":"Echemendia, R. J. et al. The Sport Concussion Assessment Tool 5th Edition (SCAT5): Background and rationale. Br. J. Sports Med. 51, 848\u2013850 (2017).","journal-title":"Br. J. Sports Med."},{"key":"54270_CR2","doi-asserted-by":"publisher","first-page":"E5","DOI":"10.3171\/2016.1.FOCUS15617","volume":"40","author":"JG Hobbs","year":"2016","unstructured":"Hobbs, J. G., Young, J. S. & Bailes, J. E. Sports-related concussions: diagnosis, complications, and current management strategies. Neurosurg. Focus 40, E5 (2016).","journal-title":"Neurosurg. Focus"},{"key":"54270_CR3","doi-asserted-by":"publisher","first-page":"3","DOI":"10.4097\/kjae.2014.66.1.3","volume":"66","author":"JR Lee","year":"2014","unstructured":"Lee, J. R. Anesthetic considerations for robotic surgery. Korean J. Anesthesiol. 66, 3\u201311 (2014).","journal-title":"Korean J. Anesthesiol."},{"key":"54270_CR4","doi-asserted-by":"publisher","first-page":"668","DOI":"10.1213\/ANE.0b013e3181c35926","volume":"110","author":"GA Mashour","year":"2010","unstructured":"Mashour, G. A. Posttraumatic stress disorder after intraoperative awareness and high-risk surgery. Anesthesia and Analgesia 110, 668\u2013670 (2010).","journal-title":"Anesthesia and Analgesia"},{"key":"54270_CR5","doi-asserted-by":"publisher","first-page":"85","DOI":"10.1093\/bja\/ael120","volume":"97","author":"J Bruhn","year":"2006","unstructured":"Bruhn, J., Myles, P. S., Sneyd, R. & Struys, M. M. R. F. Depth of anaesthesia monitoring: what\u2019 s available, what\u2019 s validated and what\u2019 s next? Br. J. Anaesth. 97, 85\u201394 (2006).","journal-title":"Br. J. Anaesth."},{"key":"54270_CR6","doi-asserted-by":"publisher","first-page":"336","DOI":"10.1093\/bja\/aei047","volume":"94","author":"P Hans","year":"2005","unstructured":"Hans, P., Dewandre, P. Y., Brichant, J. F. & Bonhomme, V. Comparative effects of ketamine on Bispectral Index and spectral entropy of the electroencephalogram under sevoflurane anaesthesia. Br. J. Anaesth. 94, 336\u2013340 (2005).","journal-title":"Br. J. Anaesth."},{"key":"54270_CR7","doi-asserted-by":"publisher","first-page":"214","DOI":"10.1097\/ALN.0000000000001479","volume":"126","author":"RD Sanders","year":"2017","unstructured":"Sanders, R. D. et al. Incidence of Connected Consciousness after Tracheal Intubation. Anesthesiology 126, 214\u2013222 (2017).","journal-title":"Anesthesiology"},{"key":"54270_CR8","doi-asserted-by":"publisher","first-page":"i95","DOI":"10.1093\/bja\/aev072","volume":"115","author":"PJ Schuller","year":"2015","unstructured":"Schuller, P. J., Newell, S., Strickland, P. A. & Barry, J. J. Response of bispectral index to neuromuscular block in awake volunteers. Br. J. Anaesth. 115, i95\u2013i103 (2015).","journal-title":"Br. J. Anaesth."},{"key":"54270_CR9","doi-asserted-by":"publisher","first-page":"488","DOI":"10.1213\/01.ANE.0000072741.78244.C0","volume":"97","author":"M Messner","year":"2003","unstructured":"Messner, M., Beese, U., Romst\u00f6ck, J., Dinkel, M. & Tschaikowsky, K. The bispectral index declines during neuromuscular block in fully awake persons. Anesth. Analg. 97, 488\u2013491 (2003).","journal-title":"Anesth. Analg."},{"key":"54270_CR10","doi-asserted-by":"publisher","first-page":"1363","DOI":"10.1213\/01.ANE.0000148121.84560.8D","volume":"100","author":"SE Rampersad","year":"2005","unstructured":"Rampersad, S. E. & Mulroy, M. F. A case of awareness despite an \u2018adequate depth of anesthesia\u2019 as indicated by a Bispectral Index?? monitor. Anesth. Analg. 100, 1363\u20131364 (2005).","journal-title":"Anesth. Analg."},{"key":"54270_CR11","doi-asserted-by":"publisher","first-page":"1097","DOI":"10.1056\/NEJMoa0707361","volume":"358","author":"M Avidan","year":"2008","unstructured":"Avidan, M. & Zhang, L. Anesthesia awareness and the bispectral index. N. Engl. J. Med. 358, 1097\u20131108 (2008).","journal-title":"N. Engl. J. Med."},{"key":"54270_CR12","doi-asserted-by":"publisher","first-page":"494","DOI":"10.1093\/bja\/aet012","volume":"110","author":"MS Avidan","year":"2013","unstructured":"Avidan, M. S. & Mashour, G. A. The incidence of intraoperative awareness in the UK: Under the rate or under the radar? British Journal of Anaesthesia 110, 494\u2013497 (2013).","journal-title":"British Journal of Anaesthesia"},{"key":"54270_CR13","doi-asserted-by":"publisher","first-page":"560","DOI":"10.1093\/bja\/aeu314","volume":"113","author":"TM Cook","year":"2014","unstructured":"Cook, T. M. et al. 5th National Audit Project (NAP5) on accidental awareness during general anaesthesia: Patient experiences, human factors, sedation, consent, and medicolegal issues. Br. J. Anaesth. 113, 560\u2013574 (2014).","journal-title":"Br. J. Anaesth."},{"key":"54270_CR14","doi-asserted-by":"publisher","first-page":"1158","DOI":"10.1213\/ANE.0000000000001175","volume":"122","author":"Y Chen","year":"2016","unstructured":"Chen, Y. et al. Amnesia of the Operating Room in the B-Unaware and BAG-RECALL Clinical Trials. Anesth. Analg. 122, 1158\u20131168 (2016).","journal-title":"Anesth. Analg."},{"key":"54270_CR15","doi-asserted-by":"publisher","first-page":"711","DOI":"10.1097\/ACO.0000000000000387","volume":"29","author":"EJ Stein","year":"2016","unstructured":"Stein, E. J. & Glick, D. B. Advances in awareness monitoring technologies. Curr. Opin. Anaesthesiol. 29, 711\u2013716 (2016).","journal-title":"Curr. Opin. Anaesthesiol."},{"key":"54270_CR16","doi-asserted-by":"publisher","first-page":"237","DOI":"10.1136\/emermed-2016-205767","volume":"34","author":"GJ Smits","year":"2017","unstructured":"Smits, G. J. et al. Procedural sedation in the emergency department by Dutch emergency physicians: A prospective multicentre observational study of 1711 adults. Emerg. Med. J. 34, 237\u2013242 (2017).","journal-title":"Emerg. Med. J."},{"key":"54270_CR17","doi-asserted-by":"publisher","first-page":"1169","DOI":"10.1007\/s12630-015-0463-3","volume":"62","author":"M Allen","year":"2015","unstructured":"Allen, M. et al. A randomized controlled trial of light versus deep propofol sedation for elective outpatient colonoscopy: recall, procedural conditions, and recoveryUne \u00e9tude randomis\u00e9e contr\u00f4l\u00e9e sur la s\u00e9dation l\u00e9g\u00e8re vs profonde au propofol pour la colonoscopie non urg. Can. J. Anesth. Can. d\u2019anesth\u00e9sie 62, 1169\u20131178 (2015).","journal-title":"Can. J. Anesth. Can. d\u2019anesth\u00e9sie"},{"key":"54270_CR18","doi-asserted-by":"publisher","first-page":"18","DOI":"10.1097\/00003643-200201000-00003","volume":"19","author":"ML Riess","year":"2009","unstructured":"Riess, M. L., Goeters, C., Graefe, U. A., Bone, H. G. & Van Aken, H. Sedation assessment in critically ill patients with bispectral index. Eur. J. Anaesthesiol. 19, 18\u201322 (2009).","journal-title":"Eur. J. Anaesthesiol."},{"key":"54270_CR19","doi-asserted-by":"publisher","first-page":"381","DOI":"10.1093\/bja\/aes386","volume":"110","author":"CD Kent","year":"2013","unstructured":"Kent, C. D., Mashour, G. A., Metzger, N. A., Posner, K. L. & Domino, K. B. Psychological impact of unexpected explicit recall of events occurring during surgery performed under sedation, regional anaesthesia, and general anaesthesia: Data from the Anesthesia Awareness Registry. Br. J. Anaesth. 110, 381\u2013387 (2013).","journal-title":"Br. J. Anaesth."},{"issue":"4","key":"54270_CR20","doi-asserted-by":"publisher","first-page":"734","DOI":"10.1097\/00000542-199710000-00002","volume":"87","author":"M. M. Ghoneim","year":"1997","unstructured":"Drugs, Memory and Sedation. Anesthesiology 87, 734\u20136 (1997).","journal-title":"Anesthesiology"},{"key":"54270_CR21","unstructured":"Depth of anaesthesia monitors \u2013 Bispectral Index (BIS), E-Entropy and Narcotrend-Compact M | Guidance and guidelines | NICE. https:\/\/www.nice.org.uk\/guidance\/dg6."},{"key":"54270_CR22","doi-asserted-by":"publisher","first-page":"569","DOI":"10.1016\/j.anclin.2017.07.003","volume":"35","author":"ZG Woodward","year":"2017","unstructured":"Woodward, Z. G., Urman, R. D. & Domino, K. B. Safety of Non\u2013Operating Room Anesthesia: A Closed Claims Update. Anesthesiology Clinics 35, 569\u2013581 (2017).","journal-title":"Anesthesiology Clinics"},{"key":"54270_CR23","doi-asserted-by":"publisher","first-page":"305","DOI":"10.3389\/fnhum.2013.00305","volume":"7","author":"G Shahaf","year":"2013","unstructured":"Shahaf, G. & Pratt, H. Thorough Specification of the Neurophysiologic Processes Underlying Behavior and of Their Manifestation in EEG \u2013 Demonstration with the Go\/No-Go Task. Front. Hum. Neurosci. 7, 305 (2013).","journal-title":"Front. Hum. Neurosci."},{"key":"54270_CR24","doi-asserted-by":"publisher","first-page":"183","DOI":"10.1016\/j.jneumeth.2014.10.016","volume":"239","author":"G Shahaf","year":"2015","unstructured":"Shahaf, G., Fisher, T., Aharon-Peretz, J. & Pratt, H. Comprehensive analysis suggests simple processes underlying EEG\/ERP - Demonstration with the go\/no-go paradigm in ADHD. J. Neurosci. Methods 239, 183\u2013193 (2015).","journal-title":"J. Neurosci. Methods"},{"key":"54270_CR25","doi-asserted-by":"publisher","first-page":"163","DOI":"10.1023\/B:JOCM.0000042921.47988.bf","volume":"18","author":"H Ypp\u00e4ril\u00e4","year":"2004","unstructured":"Ypp\u00e4ril\u00e4, H. et al. N100 auditory potential and electroencephalogram discriminate propofol-induced sedation levels. J. Clin. Monit. Comput. 18, 163\u2013170 (2004).","journal-title":"J. Clin. Monit. Comput."},{"key":"54270_CR26","doi-asserted-by":"publisher","first-page":"896","DOI":"10.1097\/00000542-200110000-00018","volume":"95","author":"RA Veselis","year":"2001","unstructured":"Veselis, R. A., Reinsel, R. A. & Feshchenko, V. A. Drug-induced amnesia is a separate phenomenon from sedation: electrophysiologic evidence. Anesthesiology 95, 896\u2013907 (2001).","journal-title":"Anesthesiology"},{"key":"54270_CR27","doi-asserted-by":"publisher","first-page":"364","DOI":"10.1097\/00000542-200108000-00017","volume":"95","author":"T Kurita","year":"2001","unstructured":"Kurita, T. et al. Auditory evoked potential index predicts the depth of sedation and movement in response to skin incision during sevoflurane anesthesia. Anesthesiology 95, 364\u2013370 (2001).","journal-title":"Anesthesiology"},{"key":"54270_CR28","doi-asserted-by":"publisher","first-page":"441","DOI":"10.1007\/s12013-014-0221-0","volume":"71","author":"X Dong","year":"2014","unstructured":"Dong, X., Suo, P., Yuan, X. & Yao, X. Use of Auditory Evoked Potentials for Intra-Operative Awareness in Anesthesia: A Consciousness-Based Conceptual Model. Cell Biochem. Biophys. 71, 441\u2013447 (2014).","journal-title":"Cell Biochem. Biophys."},{"key":"54270_CR29","doi-asserted-by":"publisher","first-page":"2638","DOI":"10.1056\/NEJMra0808281","volume":"363","author":"EN Brown","year":"2010","unstructured":"Brown, E. N., Lydic, R. & Schiff, N. D. General Anesthesia, Sleep, and Coma. N. Engl. J. Med. 363, 2638\u20132650 (2010).","journal-title":"N. Engl. J. Med."},{"key":"54270_CR30","doi-asserted-by":"publisher","first-page":"937","DOI":"10.1097\/ALN.0000000000000841","volume":"123","author":"PL Purdon","year":"2015","unstructured":"Purdon, P. L., Sampson, A., Pavone, K. J. & Brown, E. N. Clinical Electroencephalography for Anesthesiologists Part I: Background and Basic Signatures. Anesthesiology 123, 937\u2013960 (2015).","journal-title":"Anesthesiology"},{"key":"54270_CR31","doi-asserted-by":"publisher","first-page":"E1142","DOI":"10.1073\/pnas.1221180110","volume":"110","author":"PL Purdon","year":"2013","unstructured":"Purdon, P. L. et al. Electroencephalogram signatures of loss and recovery of consciousness from propofol. Proc. Natl. Acad. Sci. USA 110, E1142\u201351 (2013).","journal-title":"Proc. Natl. Acad. Sci. USA"},{"key":"54270_CR32","doi-asserted-by":"publisher","first-page":"128","DOI":"10.3389\/fpsyt.2017.00128","volume":"8","author":"G Shahaf","year":"2017","unstructured":"Shahaf, G. et al. A pilot study of possible easy-to-use electrophysiological index for early detection of antidepressive treatment non-response. Front. Psychiatry 8, 128 (2017).","journal-title":"Front. Psychiatry"},{"key":"54270_CR33","doi-asserted-by":"publisher","first-page":"32","DOI":"10.3389\/fnhum.2018.00032","volume":"12","author":"G Shahaf","year":"2018","unstructured":"Shahaf, G., Nitzan, U., Erez, G., Mendelovic, S. & Bloch, Y. Monitoring attention in ADHD with an easy-to-use electrophysiological index. Frontiers in Human Neuroscience 12, 32 (2018).","journal-title":"Frontiers in Human Neuroscience"},{"key":"54270_CR34","doi-asserted-by":"publisher","first-page":"535","DOI":"10.1093\/bja\/42.6.535","volume":"42","author":"DD Brice","year":"1970","unstructured":"Brice, D. D., Hetherington, R. R. & Utting, J. E. A simple study of awareness and dreaming during anaesthesia. BJA Br. J. Anaesth. 42, 535\u2013542 (1970).","journal-title":"BJA Br. J. Anaesth."},{"key":"54270_CR35","doi-asserted-by":"publisher","first-page":"609","DOI":"10.1213\/00000539-198806000-00041","volume":"67","author":"MJ Bloom","year":"1988","unstructured":"Bloom, M. J. EEG Atlas for Anesthesiologists. Anesth. Analg. 67, 609\u2013610 (1988).","journal-title":"Anesth. Analg."},{"key":"54270_CR36","doi-asserted-by":"publisher","first-page":"1095","DOI":"10.1093\/bja\/55.11.1095","volume":"55","author":"VC Magni","year":"1983","unstructured":"Magni, V. C., Frost, R. A., Leung, J. W. C. & Cotton, P. B. A randomized comparison of midazolam and diazepam for sedation in upper gastrointestinal endoscopy. Br. J. Anaesth. 55, 1095\u20131101 (1983).","journal-title":"Br. J. Anaesth."},{"key":"54270_CR37","doi-asserted-by":"publisher","first-page":"1158","DOI":"10.1213\/ANE.0000000000001175","volume":"122","author":"Y Chen","year":"2016","unstructured":"Chen, Y. et al. Amnesia of the operating room in the B-Unaware and BAG-RECALL clinical trials. in. Anesthesia and Analgesia 122, 1158\u20131168 (2016).","journal-title":"Anesthesia and Analgesia"},{"key":"54270_CR38","first-page":"S917","volume":"26","author":"D Wang","year":"2015","unstructured":"Wang, D. et al. Auditory evoked potentials in patients with major depressive disorder measured by Emotiv system. Biomed. Mater. Eng. 26, S917\u2013S923 (2015).","journal-title":"Biomed. Mater. Eng."},{"key":"54270_CR39","doi-asserted-by":"publisher","first-page":"e907","DOI":"10.7717\/peerj.907","volume":"3","author":"J Thie","year":"2015","unstructured":"Thie, J. et al. Validation of the Emotiv EPOC EEG system for research quality auditory event-related potentials in children. PeerJ 3, e907 (2015).","journal-title":"PeerJ"},{"key":"54270_CR40","doi-asserted-by":"publisher","first-page":"81","DOI":"10.1016\/j.berh.2005.09.006","volume":"20","author":"JW Johansen","year":"2006","unstructured":"Johansen, J. W. Update on bispectral index monitoring. Best Practice and Research: Clinical Anaesthesiology 20, 81\u201399 (2006).","journal-title":"Best Practice and Research: Clinical Anaesthesiology"},{"key":"54270_CR41","doi-asserted-by":"publisher","first-page":"274","DOI":"10.1097\/YCT.0000000000000551","volume":"34","author":"M Isserles","year":"2018","unstructured":"Isserles, M. et al. Simple Electroencephalographic Treatment-Emergent Marker Can Predict Repetitive Transcranial Magnetic Stimulation Antidepressant Response - A Feasibility Study. J. ECT 34, 274\u2013282 (2018).","journal-title":"J. ECT"},{"key":"54270_CR42","doi-asserted-by":"publisher","first-page":"2114","DOI":"10.1016\/j.neuropsychologia.2009.04.013","volume":"47","author":"SK Loo","year":"2009","unstructured":"Loo, S. K. et al. Cortical activity patterns in ADHD during arousal, activation and sustained attention. Neuropsychologia 47, 2114\u20132119 (2009).","journal-title":"Neuropsychologia"},{"key":"54270_CR43","doi-asserted-by":"publisher","first-page":"1443","DOI":"10.1016\/j.neuroimage.2006.11.004","volume":"34","author":"A Delorme","year":"2007","unstructured":"Delorme, A., Sejnowski, T. & Makeig, S. Enhanced detection of artifacts in EEG data using higher-order statistics and independent component analysis. Neuroimage 34, 1443\u20131449 (2007).","journal-title":"Neuroimage"},{"key":"54270_CR44","unstructured":"Rosner, B. Fundamentals of biostatistics - Page xiv. 859 (2010)."},{"key":"54270_CR45","doi-asserted-by":"publisher","first-page":"1469","DOI":"10.1088\/0967-3334\/36\/7\/1469","volume":"36","author":"TS Grummett","year":"2015","unstructured":"Grummett, T. S. et al. Measurement of neural signals from inexpensive, wireless and dry EEG systems. Physiol. Meas. 36, 1469\u20131484 (2015).","journal-title":"Physiol. Meas."},{"key":"54270_CR46","doi-asserted-by":"publisher","first-page":"158","DOI":"10.1109\/JBHI.2014.2333010","volume":"19","author":"R Mahajan","year":"2015","unstructured":"Mahajan, R. & Morshed, B. I. Unsupervised eye blink artifact denoising of EEG data with modified multiscale sample entropy, kurtosis, and wavelet-ICA. IEEE J. Biomed. Heal. Informatics 19, 158\u2013165 (2015).","journal-title":"IEEE J. Biomed. Heal. Informatics"},{"key":"54270_CR47","doi-asserted-by":"publisher","first-page":"e46","DOI":"10.1161\/STR.0000000000000158","volume":"49","author":"WJ Powers","year":"2018","unstructured":"Powers, W. J. et al. Guidelines for the Early Management of Patients With Acute Ischemic Stroke: A Guideline for Healthcare Professionals From the American Heart Association\/American Stroke Association. Stroke 49, e46\u2013e110 (2018).","journal-title":"Stroke"},{"key":"54270_CR48","doi-asserted-by":"publisher","first-page":"1139","DOI":"10.1001\/archpsyc.57.12.1139","volume":"57","author":"D Umbricht","year":"2000","unstructured":"Umbricht, D. et al. Ketamine-Induced Deficits in Auditory and Visual Context-Dependent Processing in Healthy Volunteers. Arch. Gen. Psychiatry 57, 1139 (2000).","journal-title":"Arch. Gen. Psychiatry"},{"key":"54270_CR49","doi-asserted-by":"publisher","first-page":"1660","DOI":"10.1016\/j.clinph.2006.05.011","volume":"117","author":"A Maksimow","year":"2006","unstructured":"Maksimow, A. et al. Increase in high frequency EEG activity explains the poor performance of EEG spectral entropy monitor during S-ketamine anesthesia. Clin. Neurophysiol. 117, 1660\u20131668 (2006).","journal-title":"Clin. Neurophysiol."},{"key":"54270_CR50","doi-asserted-by":"publisher","first-page":"46","DOI":"10.4065\/81.1.46","volume":"81","author":"CJ Chisholm","year":"2006","unstructured":"Chisholm, C. J. et al. Comparison of electrophysiologic monitors with clinical assessment of level of sedation. Mayo Clin. Proc. 81, 46\u201352 (2006).","journal-title":"Mayo Clin. Proc."}],"container-title":["Scientific Reports"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.nature.com\/articles\/s41598-019-54270-3.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.nature.com\/articles\/s41598-019-54270-3","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.nature.com\/articles\/s41598-019-54270-3.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2022,12,17]],"date-time":"2022-12-17T16:42:50Z","timestamp":1671295370000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.nature.com\/articles\/s41598-019-54270-3"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2019,11,28]]},"references-count":50,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2019,12]]}},"alternative-id":["54270"],"URL":"https:\/\/doi.org\/10.1038\/s41598-019-54270-3","relation":{},"ISSN":["2045-2322"],"issn-type":[{"value":"2045-2322","type":"electronic"}],"subject":[],"published":{"date-parts":[[2019,11,28]]},"assertion":[{"value":"23 August 2019","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"8 November 2019","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"28 November 2019","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"This study was supported by Grant from the Israel Society of Anesthesia (ISA) and by the SMHA-Innovation Fund-SMH-19-012. NeuroIndex LTD is the company, which developed the electrophysiological marker, presented in this work. DBS is the primary investigator and the clinical advisor of NeuroIndex Ltd. GS is the founder and chief scientist of NeuroIndex Ltd. <u>DBS and GS are spouses<\/u>. The study started prior to the establishment of NeuroIndex Ltd. However, NeuroIndex purchased the study data from DBS. The other authors do not have conflict of interest to declare in this study.","order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"17859"}}