{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,3,31]],"date-time":"2026-03-31T14:28:20Z","timestamp":1774967300515,"version":"3.50.1"},"reference-count":34,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2020,1,23]],"date-time":"2020-01-23T00:00:00Z","timestamp":1579737600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2020,1,23]],"date-time":"2020-01-23T00:00:00Z","timestamp":1579737600000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Sci Rep"],"abstract":"<jats:title>Abstract<\/jats:title><jats:p>The choroid is a complex vascular tissue that is covered with the retinal pigment epithelium. Ultra high speed swept source optical coherence tomography (SS-OCT) provides us with high-resolution cube scan images of the choroid. Robust segmentation techniques are required to reconstruct choroidal volume using SS-OCT images. For automated segmentation, the delineation of the choroidal-scleral (C-S) boundary is key to accurate segmentation. Low contrast of the boundary, scleral canals formed by the vessel and the nerve, and the posterior stromal layer, may cause segmentation errors. Semantic segmentation is one of the applications of deep learning used to classify the parts of images related to the meanings of the subjects. We applied semantic segmentation to choroidal segmentation and measured the volume of the choroid. The measurement results were validated through comparison with those of other segmentation methods. As a result, semantic segmentation was able to segment the C-S boundary and choroidal volume adequately.<\/jats:p>","DOI":"10.1038\/s41598-020-57788-z","type":"journal-article","created":{"date-parts":[[2020,1,23]],"date-time":"2020-01-23T11:02:58Z","timestamp":1579777378000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":29,"title":["Semantic Segmentation of the Choroid in Swept Source Optical Coherence Tomography Images for Volumetrics"],"prefix":"10.1038","volume":"10","author":[{"given":"Shingo","family":"Tsuji","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Tetsuju","family":"Sekiryu","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Yukinori","family":"Sugano","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Akira","family":"Ojima","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Akihito","family":"Kasai","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Masahiro","family":"Okamoto","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Satoshi","family":"Eifuku","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2020,1,23]]},"reference":[{"key":"57788_CR1","first-page":"129","volume":"24","author":"RW Flower","year":"1988","unstructured":"Flower, R. W. Physiology of the developing ocular vasculature. Birth Defects Orig. Artic. Ser. 24, 129\u2013146 (1988).","journal-title":"Birth Defects Orig. Artic. Ser."},{"key":"57788_CR2","doi-asserted-by":"publisher","first-page":"120","DOI":"10.1007\/BF02764304","volume":"228","author":"E Stefansson","year":"1990","unstructured":"Stefansson, E. Oxygen and diabetic eye disease. Graefes Arch. Clin. Exp. Ophthalmol. 228, 120\u2013123 (1990).","journal-title":"Graefes Arch. Clin. Exp. Ophthalmol."},{"key":"57788_CR3","doi-asserted-by":"publisher","first-page":"113","DOI":"10.1016\/S0002-9394(14)71762-3","volume":"116","author":"AF Fercher","year":"1993","unstructured":"Fercher, A. F., Hitzenberger, C. K., Drexler, W., Kamp, G. & Sattmann, H. In vivo optical coherence tomography. Am. J. Ophthalmol. 116, 113\u2013114 (1993).","journal-title":"Am. J. Ophthalmol."},{"key":"57788_CR4","doi-asserted-by":"publisher","first-page":"1178","DOI":"10.1126\/science.1957169","volume":"254","author":"D Huang","year":"1991","unstructured":"Huang, D. et al. Optical coherence tomography. Science 254, 1178\u20131181 (1991).","journal-title":"Science"},{"key":"57788_CR5","doi-asserted-by":"publisher","first-page":"1864","DOI":"10.1364\/OL.18.001864","volume":"18","author":"EA Swanson","year":"1993","unstructured":"Swanson, E. A. et al. In vivo retinal imaging by optical coherence tomography. Opt. Lett. 18, 1864\u20131866 (1993).","journal-title":"Opt. Lett."},{"key":"57788_CR6","doi-asserted-by":"publisher","first-page":"510","DOI":"10.1097\/IAE.0b013e3181eef053","volume":"31","author":"I Maruko","year":"2011","unstructured":"Maruko, I. et al. Subfoveal choroidal thickness after treatment of Vogt-Koyanagi-Harada disease. Retina 31, 510\u2013517, https:\/\/doi.org\/10.1097\/IAE.0b013e3181eef053 (2011).","journal-title":"Retina"},{"key":"57788_CR7","doi-asserted-by":"publisher","first-page":"271","DOI":"10.5301\/EJO.2010.5848","volume":"21","author":"K Sayanagi","year":"2011","unstructured":"Sayanagi, K., Pelayes, D. E., Kaiser, P. K. & Singh, A. D. 3D Spectral domain optical coherence tomography findings in choroidal tumors. Eur. J. ophthalmology 21, 271\u2013275, https:\/\/doi.org\/10.5301\/EJO.2010.5848 (2011).","journal-title":"Eur. J. ophthalmology"},{"key":"57788_CR8","doi-asserted-by":"publisher","first-page":"6256","DOI":"10.1167\/iovs.16-20161","volume":"57","author":"F Zheng","year":"2016","unstructured":"Zheng, F. et al. Choroidal Thickness and Choroidal Vessel Density in Nonexudative Age-Related Macular Degeneration Using Swept-Source Optical Coherence Tomography Imaging. Invest. Ophthalmol. Vis. Sci. 57, 6256\u20136264, https:\/\/doi.org\/10.1167\/iovs.16-20161 (2016).","journal-title":"Invest. Ophthalmol. Vis. Sci."},{"key":"57788_CR9","doi-asserted-by":"publisher","first-page":"499","DOI":"10.1097\/iae.0000000000000742","volume":"36","author":"KK Dansingani","year":"2016","unstructured":"Dansingani, K. K., Balaratnasingam, C., Naysan, J. & Freund, K. B. En Face Imaging of Pachychoroid Spectrum Disorders with Swept-Source Optical Coherence Tomography. Retina 36, 499\u2013516, https:\/\/doi.org\/10.1097\/iae.0000000000000742 (2016).","journal-title":"Retina"},{"key":"57788_CR10","doi-asserted-by":"publisher","first-page":"1792","DOI":"10.1016\/j.ophtha.2010.01.023","volume":"117","author":"I Maruko","year":"2010","unstructured":"Maruko, I. et al. Subfoveal choroidal thickness after treatment of central serous chorioretinopathy. Ophthalmology. 117, 1792\u20131799, https:\/\/doi.org\/10.1016\/j.ophtha.2010.01.023 (2010).","journal-title":"Ophthalmology."},{"issue":"4","key":"57788_CR11","doi-asserted-by":"publisher","first-page":"2674","DOI":"10.1167\/iovs.13-13338","volume":"55","author":"Paulina Haas","year":"2014","unstructured":"Haas P., Esmaeelpour M., Ansari-Shahrezaei S., Drexler W. & Binder S. Choroidal thickness in patients with reticular pseudodrusen using 3D 1060-nm OCT maps. Invest Ophthalmol. Vis. Sci. 55, https:\/\/doi.org\/10.1167\/iovs.13-13338 (2014).","journal-title":"Investigative Opthalmology & Visual Science"},{"key":"57788_CR12","doi-asserted-by":"publisher","first-page":"80","DOI":"10.1016\/j.ajo.2016.01.011","volume":"164","author":"Eduardo A. Novais","year":"2016","unstructured":"Novais E. A. et al. Choroidal Neovascularization Analyzed on Ultrahigh-Speed Swept-Source Optical Coherence Tomography Angiography Compared to Spectral-Domain Optical Coherence Tomography Angiography. Am. J. Ophthalmol. 164, https:\/\/doi.org\/10.1016\/j.ajo.2016.01.011 (2016).","journal-title":"American Journal of Ophthalmology"},{"issue":"8","key":"57788_CR13","doi-asserted-by":"publisher","first-page":"899","DOI":"10.1001\/jamaophthalmol.2015.1320","volume":"133","author":"Marco Antonio Bonini Filho","year":"2015","unstructured":"Bonini Filho, M. A. et al. Association of Choroidal Neovascularization and Central Serous Chorioretinopathy With Optical Coherence Tomography Angiography. JAMA Ophthalmol. 133, https:\/\/doi.org\/10.1001\/jamaophthalmol.2015.1320 (2015).","journal-title":"JAMA Ophthalmology"},{"issue":"3","key":"57788_CR14","doi-asserted-by":"publisher","first-page":"325-329.e1","DOI":"10.1016\/j.ajo.2010.04.018","volume":"150","author":"Varsha Manjunath","year":"2010","unstructured":"Manjunath, V., Taha, M., Fujimoto, J. G. & Duker, J. S. Choroidal thickness in normal eyes measured using Cirrus HD optical coherence tomography. Am. J. Ophthalmol. 150, https:\/\/doi.org\/10.1016\/j.ajo.2010.04.018 (2010).","journal-title":"American Journal of Ophthalmology"},{"issue":"6","key":"57788_CR15","doi-asserted-by":"publisher","first-page":"3532","DOI":"10.1167\/iovs.14-13868","volume":"55","author":"Jorge Ruiz-Medrano","year":"2014","unstructured":"Ruiz-Medrano, J. et al Macular choroidal thickness profile in a healthy population measured by swept-source optical coherence tomography. Invest Ophthalmol. Vis. Sci. 55, https:\/\/doi.org\/10.1167\/iovs.14-13868 (2014).","journal-title":"Investigative Opthalmology & Visual Science"},{"key":"57788_CR16","doi-asserted-by":"publisher","first-page":"3202","DOI":"10.1167\/iovs.14-15669","volume":"56","author":"L Zhang","year":"2015","unstructured":"Zhang, L. et al. Validity of Automated Choroidal Segmentation in SS-OCT and SD-OCT. Invest. Ophthalmol. Vis. Sci. 56, 3202\u20133211, https:\/\/doi.org\/10.1167\/iovs.14-15669 (2015).","journal-title":"Invest. Ophthalmol. Vis. Sci."},{"key":"57788_CR17","doi-asserted-by":"publisher","first-page":"42112","DOI":"10.1038\/srep42112","volume":"7","author":"J Mazzaferri","year":"2017","unstructured":"Mazzaferri, J., Beaton, L., Hounye, G., Sayah, D. N. & Costantino, S. Open-source algorithm for automatic choroid segmentation of OCT volume reconstructions. Sci. rep. 7, 42112, https:\/\/doi.org\/10.1038\/srep42112 (2017).","journal-title":"Sci. rep."},{"key":"57788_CR18","doi-asserted-by":"publisher","first-page":"15787","DOI":"10.1364\/oe.21.015787","volume":"21","author":"L Duan","year":"2013","unstructured":"Duan, L., Hong, Y. J. & Yasuno, Y. Automated segmentation and characterization of choroidal vessels in high-penetration optical coherence tomography. Opt. Express 21, 15787\u201315808, https:\/\/doi.org\/10.1364\/oe.21.015787 (2013).","journal-title":"Opt. Express"},{"issue":"8","key":"57788_CR19","doi-asserted-by":"publisher","first-page":"1313","DOI":"10.3390\/ijms17081313","volume":"17","author":"Lucas Pastur-Romay","year":"2016","unstructured":"Pastur-Romay, L. A., Cedron, F., Pazos, A. & Porto-Pazos, A. B. Deep Artificial Neural Networks and Neuromorphic Chips for Big Data Analysis: Pharmaceutical and Bioinformatics Applications. Int. J. Mol. Sci. 17, https:\/\/doi.org\/10.3390\/ijms17081313 (2016).","journal-title":"International Journal of Molecular Sciences"},{"key":"57788_CR20","doi-asserted-by":"publisher","first-page":"3627","DOI":"10.1364\/boe.8.003627","volume":"8","author":"AG Roy","year":"2017","unstructured":"Roy, A. G. et al. ReLayNet: retinal layer and fluid segmentation of macular optical coherence tomography using fully convolutional networks. Biomed. Opt. express 8, 3627\u20133642, https:\/\/doi.org\/10.1364\/boe.8.003627 (2017).","journal-title":"Biomed. Opt. express"},{"key":"57788_CR21","doi-asserted-by":"publisher","first-page":"640","DOI":"10.1109\/tpami.2016.2572683","volume":"39","author":"E Shelhamer","year":"2017","unstructured":"Shelhamer, E., Long, J. & Darrell, T. Fully Convolutional Networks for Semantic Segmentation. IEEE Trans. pattern Anal. Mach. Intell. 39, 640\u2013651, https:\/\/doi.org\/10.1109\/tpami.2016.2572683 (2017).","journal-title":"IEEE Trans. pattern Anal. Mach. Intell."},{"key":"57788_CR22","doi-asserted-by":"publisher","first-page":"177","DOI":"10.1007\/978-3-319-67561-9_20","volume":"10554","author":"M Chen","year":"2017","unstructured":"Chen, M., Wang, J., Oguz, I., VanderBeek, B. L. & Gee, J. C. Automated segmentation of the choroid in EDI-OCT images with retinal pathology using convolution neural networks. Fetal, infant. ophthalmic Med. image analysis: Int. Workshop, FIFI 2017, 4th Int. Workshop, OMIA 2017, held conjunction MICCAI 2017, Que. City, QC, Canada, September 14 10554, 177\u2013184 (2017).","journal-title":"Fetal, infant. ophthalmic Med. image analysis: Int. Workshop, FIFI 2017, 4th Int. Workshop, OMIA 2017, held conjunction MICCAI 2017, Que. City, QC, Canada, September 14"},{"key":"57788_CR23","unstructured":"Kei Otsuka. Medical Image Segmentation Using SegNet, https:\/\/www.mathworks.com\/matlabcentral\/fileexchange\/66448-medical-image-segmentation-using-segnet, MATLAB Central File Exchange. Retrieved July 9 (2019)."},{"key":"57788_CR24","doi-asserted-by":"publisher","first-page":"19413","DOI":"10.1364\/oe.18.019413","volume":"18","author":"SJ Chiu","year":"2010","unstructured":"Chiu, S. J. et al. Automatic segmentation of seven retinal layers in SDOCT images congruent with expert manual segmentation. Opt. Express. 18, 19413\u201319428, https:\/\/doi.org\/10.1364\/oe.18.019413 (2010).","journal-title":"Opt. Express."},{"key":"57788_CR25","doi-asserted-by":"publisher","DOI":"10.1186\/s12859-017-1934-z","volume":"18","author":"CT Rueden","year":"2017","unstructured":"Rueden, C. T. et al. ImageJ2: ImageJ for the next generation of scientific image data. BMC bioinformatics. 18, 529, https:\/\/doi.org\/10.1186\/s12859-017-1934-z (2017).","journal-title":"BMC bioinformatics."},{"key":"57788_CR26","doi-asserted-by":"publisher","first-page":"4971","DOI":"10.1167\/iovs.11-7729","volume":"52","author":"M Hirata","year":"2011","unstructured":"Hirata, M. et al. Macular choroidal thickness and volume in normal subjects measured by swept-source optical coherence tomography. Invest. Ophthalmol. Vis. Sci. 52, 4971\u20134978 (2011).","journal-title":"Invest. Ophthalmol. Vis. Sci."},{"key":"57788_CR27","doi-asserted-by":"publisher","first-page":"4404","DOI":"10.1167\/iovs.18-24665","volume":"59","author":"E Chandrasekera","year":"2018","unstructured":"Chandrasekera, E., Wong, E. N., Sampson, D. M., Alonso-Caneiro, D. & Chen, F. K. Posterior Choroidal Stroma Reduces Accuracy of Automated Segmentation of Outer Choroidal Boundary in Swept Source Optical Coherence Tomography. Invest. Ophthalmol. Vis. Sci. 59, 4404\u20134412, https:\/\/doi.org\/10.1167\/iovs.18-24665 (2018).","journal-title":"Invest. Ophthalmol. Vis. Sci."},{"key":"57788_CR28","doi-asserted-by":"publisher","first-page":"1694","DOI":"10.1364\/boe.6.001694","volume":"6","author":"L Beaton","year":"2015","unstructured":"Beaton, L. et al. Non-invasive measurement of choroidal volume change and ocular rigidity through automated segmentation of high-speed OCT imaging. Biomed. Opt. express 6, 1694\u20131706, https:\/\/doi.org\/10.1364\/boe.6.001694 (2015).","journal-title":"Biomed. Opt. express"},{"key":"57788_CR29","doi-asserted-by":"publisher","first-page":"134","DOI":"10.1364\/boe.4.000134","volume":"4","author":"V Kajic","year":"2013","unstructured":"Kajic, V. et al. Automated three-dimensional choroidal vessel segmentation of 3D 1060 nm OCT retinal data. Biomed. Opt. express. 4, 134\u2013150, https:\/\/doi.org\/10.1364\/boe.4.000134 (2013).","journal-title":"Biomed. Opt. express."},{"key":"57788_CR30","doi-asserted-by":"publisher","first-page":"86","DOI":"10.1364\/boe.3.000086","volume":"3","author":"V Kajic","year":"2012","unstructured":"Kajic, V. et al. Automated choroidal segmentation of 1060 nm OCT in healthy and pathologic eyes using a statistical model. Biomed. Opt. express 3, 86\u2013103, https:\/\/doi.org\/10.1364\/boe.3.000086 (2012).","journal-title":"Biomed. Opt. express"},{"key":"57788_CR31","doi-asserted-by":"publisher","first-page":"7510","DOI":"10.1167\/iovs.12-10311","volume":"53","author":"L Zhang","year":"2012","unstructured":"Zhang, L. et al. Automated segmentation of the choroid from clinical SD-OCT. Invest. Ophthalmol. Vis. Sci. 53, 7510\u20137519, https:\/\/doi.org\/10.1167\/iovs.12-10311 (2012).","journal-title":"Invest. Ophthalmol. Vis. Sci."},{"key":"57788_CR32","unstructured":"Hogan, M. J. Histology of the human eye. 202\u2013392 (Saunders, 1971)."},{"key":"57788_CR33","doi-asserted-by":"publisher","first-page":"1603","DOI":"10.1097\/IAE.0b013e31820f4b39","volume":"31","author":"I Maruko","year":"2011","unstructured":"Maruko, I., Iida, T., Sugano, Y., Ojima, A. & Sekiryu, T. Subfoveal choroidal thickness in fellow eyes of patients with central serous chorioretinopathy. Retina 31, 1603\u20131608, https:\/\/doi.org\/10.1097\/IAE.0b013e31820f4b39 (2011).","journal-title":"Retina"},{"key":"57788_CR34","doi-asserted-by":"publisher","first-page":"357","DOI":"10.1089\/jop.2014.0160","volume":"31","author":"M Gharbiya","year":"2015","unstructured":"Gharbiya, M. et al. Choroidal Thickness Changes After Intravitreal Antivascular Endothelial Growth Factor Therapy for Age-Related Macular Degeneration: Ranibizumab Versus Aflibercept. J. Ocul. Pharmacol. Ther. 31, 357\u2013362, https:\/\/doi.org\/10.1089\/jop.2014.0160 (2015).","journal-title":"J. Ocul. Pharmacol. Ther."}],"container-title":["Scientific Reports"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.nature.com\/articles\/s41598-020-57788-z.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.nature.com\/articles\/s41598-020-57788-z","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.nature.com\/articles\/s41598-020-57788-z.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2022,12,6]],"date-time":"2022-12-06T06:13:31Z","timestamp":1670307211000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.nature.com\/articles\/s41598-020-57788-z"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2020,1,23]]},"references-count":34,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2020,12]]}},"alternative-id":["57788"],"URL":"https:\/\/doi.org\/10.1038\/s41598-020-57788-z","relation":{},"ISSN":["2045-2322"],"issn-type":[{"value":"2045-2322","type":"electronic"}],"subject":[],"published":{"date-parts":[[2020,1,23]]},"assertion":[{"value":"14 August 2019","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"7 January 2020","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"23 January 2020","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"The authors declare no competing interests.","order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"1088"}}