{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,31]],"date-time":"2026-10-31T00:34:31Z","timestamp":1793406871074,"version":"4.5.0"},"reference-count":27,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2020,1,24]],"date-time":"2020-01-24T00:00:00Z","timestamp":1579824000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2020,1,24]],"date-time":"2020-01-24T00:00:00Z","timestamp":1579824000000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"funder":[{"name":"Italian Ministry of Health and Fondazione Roma","id":[{"id":"https:\/\/ror.org\/00gtjrz72","id-type":"ROR","asserted-by":"crossref"}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Sci Rep"],"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:p>Corneal tomography is an important tool to identify and follow up eyes with keratoconus. Our study evaluate the repeatability of the automatic measurements provided in keratoconic eyes by a new anterior-segment optical coherence tomographer (AS-OCT) combined with Placido-disk topography (MS-39, CSO) and assess their agreement with the corresponding measurements taken with a rotating Scheimpflug camera combined with Placido-disk topography (Sirius, CSO). Mean simulated keratometry, posterior and total corneal power, total corneal astigmatism, corneal asphericity, thinnest corneal thickness, epithelial thickness, corneal diameter, and aqueous depth were evaluated. Repeatability was assessed using test\u2013retest variability, the coefficient of variation, and the intraclass correlation coefficient; agreement was assessed by the 95% limits of agreement. Good repeatability was achieved for most parameters. Moderate repeatability was found for total corneal astigmatism measurements. The repeatability of mean simulated keratometry and total corneal power measurements worsened with more severe stages of keratoconus with a statistically significant relationship between the individual coefficient of variation and corneal power values. Agreement with the Scheimpflug camera was moderate for aqueous depth and thinnest corneal thickness and poor for most other measured parameters. The good repeatability of automatic measurements suggests the new AS-OCT device to be a viable option in clinical practice of eyes with keratoconus.<\/jats:p>","DOI":"10.1038\/s41598-020-57926-7","type":"journal-article","created":{"date-parts":[[2020,1,24]],"date-time":"2020-01-24T06:03:17Z","timestamp":1579845797000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":47,"title":["Repeatability of anterior segment measurements by optical coherence tomography combined with Placido disk corneal topography in eyes with keratoconus"],"prefix":"10.1038","volume":"10","author":[{"ORCID":"https:\/\/orcid.org\/0000-0001-6035-225X","authenticated-orcid":false,"given":"Domenico","family":"Schiano-Lomoriello","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Valeria","family":"Bono","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-1148-6491","authenticated-orcid":false,"given":"Irene","family":"Abicca","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Giacomo","family":"Savini","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2020,1,24]]},"reference":[{"key":"57926_CR1","doi-asserted-by":"publisher","first-page":"297","DOI":"10.1016\/S0039-6257(97)00119-7","volume":"42","author":"YS Rabinowitz","year":"1998","unstructured":"Rabinowitz, Y. S. Keratoconus. Surv. Ophthalmol. 42, 297\u2013319 (1998).","journal-title":"Surv. Ophthalmol."},{"key":"57926_CR2","doi-asserted-by":"publisher","first-page":"293","DOI":"10.1016\/0039-6257(84)90094-8","volume":"28","author":"JH Krachmer","year":"1984","unstructured":"Krachmer, J. H., Feder, R. S. & Belin, M. W. Keratoconus and related noninflammatory corneal thinning disorders. Surv. Ophthalmol. 28, 293\u2013322 (1984).","journal-title":"Surv. Ophthalmol."},{"key":"57926_CR3","first-page":"2749","volume":"35","author":"N Maeda","year":"1994","unstructured":"Maeda, N., Klyce, S. D., Smolek, M. K. & Thompson, H. W. Automated keratoconus screening with corneal topography analysis. Invest. Ophthalmol. Vis. Sci. 35, 2749\u20132757 (1994).","journal-title":"Invest. Ophthalmol. Vis. Sci."},{"key":"57926_CR4","doi-asserted-by":"publisher","first-page":"1327","DOI":"10.1016\/S0886-3350(99)00195-9","volume":"25","author":"YS Rabinowitz","year":"1999","unstructured":"Rabinowitz, Y. S. & Rasheed, K. KISA% index: a quantitative videokeratography algorithm embodying minimal topographic criteria for diagnosing keratoconus. J. Cataract. Refract. Surg. 25, 1327\u20131335 (1999).","journal-title":"J. Cataract. Refract. Surg."},{"key":"57926_CR5","doi-asserted-by":"publisher","first-page":"480","DOI":"10.1097\/ICO.0b013e31816485d3","volume":"27","author":"AM Mahmoud","year":"2008","unstructured":"Mahmoud, A. M. et al. CLEK Study Group. CLMI: the Cone Location and Magnitude Index. Cornea. 27, 480\u2013487 (2008).","journal-title":"Cornea."},{"key":"57926_CR6","doi-asserted-by":"publisher","first-page":"1851","DOI":"10.1016\/j.jcrs.2006.06.025","volume":"32","author":"R Ambro\u0301sio Jr","year":"2006","unstructured":"Ambro\u0301sio, R. Jr., Alonso, R. S., Luz, A. & Coca Velarde, L. G. Corneal thickness spatial profile and corneal-volume distribution: tomographic indices to detect keratoconus. J. Cataract. Refract. Surg. 32, 1851\u20131859 (2006).","journal-title":"J. Cataract. Refract. Surg."},{"key":"57926_CR7","doi-asserted-by":"publisher","first-page":"2231","DOI":"10.1016\/j.ophtha.2012.06.005","volume":"119","author":"MC Arbelaez","year":"2012","unstructured":"Arbelaez, M. C., Versaci, F., Vestri, G., Barboni, P. & Savini, G. Use of a support vector machine for keratoconus and subclinical keratoconus detection by topographic and tomographic data. Ophthalmology. 119, 2231\u20132238 (2012).","journal-title":"Ophthalmology."},{"key":"57926_CR8","doi-asserted-by":"publisher","first-page":"2425","DOI":"10.1016\/j.ophtha.2012.06.023","volume":"119","author":"Y Li","year":"2012","unstructured":"Li, Y., Tan, O., Brass, R., Weiss, J. L. & Huang, D. Corneal epithelial thickness mapping by Fourier-domain optical coherence tomography in normal and keratoconic eyes. Ophthalmology. 119, 2425\u20132433 (2012).","journal-title":"Ophthalmology."},{"key":"57926_CR9","doi-asserted-by":"publisher","first-page":"1544","DOI":"10.1097\/ICO.0b013e3182a7f39d","volume":"32","author":"XJ Ma","year":"2013","unstructured":"Ma, X. J., Wang, L. & Koch, D. D. Repeatability of corneal epithelial thickness measurements using Fourier-domain optical coherence tomography in normal and post-LASIK eyes. Cornea 32, 1544\u20131548 (2013).","journal-title":"Cornea"},{"key":"57926_CR10","doi-asserted-by":"publisher","first-page":"173","DOI":"10.3928\/1081597X-20130129-08","volume":"29","author":"KM Rocha","year":"2013","unstructured":"Rocha, K. M., Perez-Straziota, C. E., Stulting, R. D. & Randleman, J. B. SD-OCT analysis of regional epithelial thickness profiles in keratoconus, postoperative corneal ectasia, and normal eyes. J. Refract. Surg. 29, 173\u2013179 (2013).","journal-title":"J. Refract. Surg."},{"key":"57926_CR11","doi-asserted-by":"publisher","first-page":"485","DOI":"10.1016\/j.jcrs.2011.10.027","volume":"38","author":"E Szalai","year":"2012","unstructured":"Szalai, E., Berta, A., Hassan, Z. & Modis, L. Jr. Reliability and repeatability of swept-source Fourier-domain optical coherence tomography and Scheimpflug imaging in keratoconus. J. Cataract Refract. Surg. 38, 485\u2013494 (2012).","journal-title":"J. Cataract Refract. Surg."},{"key":"57926_CR12","doi-asserted-by":"publisher","first-page":"1934","DOI":"10.1016\/j.jcrs.2012.06.049","volume":"38","author":"J Aramberri","year":"2012","unstructured":"Aramberri, J. et al. Dual versus single Scheimpflug camera for anterior segment analysis: precision and agreement. J. Cataract Refract. Surg. 38, 1934\u20131949 (2012).","journal-title":"J. Cataract Refract. Surg."},{"key":"57926_CR13","doi-asserted-by":"publisher","first-page":"2731","DOI":"10.1016\/j.jcrs.2015.07.035","volume":"41","author":"EJ Kim","year":"2015","unstructured":"Kim, E. J. et al. Repeatability of posterior and total corneal curvature measurements with a dual Scheimpflug\u2013Placido tomographer. J. Cataract Refract. Surg. 41, 2731\u20132738 (2015).","journal-title":"J. Cataract Refract. Surg."},{"key":"57926_CR14","doi-asserted-by":"publisher","first-page":"425","DOI":"10.1016\/j.jcrs.2009.09.034","volume":"36","author":"L Wang","year":"2010","unstructured":"Wang, L., Shirayama, M. & Koch, D. D. Repeatability of corneal power and wave- front aberration measurements with a dual-Scheimpflug Placido corneal topographer. J. Cataract Refract. Surg. 36, 425\u2013430 (2010).","journal-title":"J. Cataract Refract. Surg."},{"key":"57926_CR15","doi-asserted-by":"publisher","first-page":"186","DOI":"10.1016\/j.jcrs.2014.04.037","volume":"41","author":"A Cervino","year":"2015","unstructured":"Cervino, A., Dominguez-Vicent, A., Ferrer-Blasco, T., Garc\u00eda-Lazaro, S. & Albarran-Diego, C. Intrasubject repeatability of corneal power, thickness, and wavefront aberrations with a new version of a dual rotating Scheimpflug-Placido system. J. Cataract Refract. Surg. 41, 186\u2013192 (2015).","journal-title":"J. Cataract Refract. Surg."},{"key":"57926_CR16","doi-asserted-by":"publisher","first-page":"471","DOI":"10.1016\/j.jcrs.2018.02.015","volume":"44","author":"G Savini","year":"2018","unstructured":"Savini, G., Schiano-Lomoriello, D. & Hoffer, K. J. Repeatability of automatic measurements by a new anterior segment optical coherence tomographer combined with Placido topography and agreement with 2 Scheimpflug cameras. J. Cataract Refract. Surg. 44, 471\u2013478 (2018).","journal-title":"J. Cataract Refract. Surg."},{"key":"57926_CR17","doi-asserted-by":"publisher","first-page":"1809","DOI":"10.1016\/j.jcrs.2011.04.033","volume":"37","author":"G Savini","year":"2011","unstructured":"Savini, G., Barboni, P., Carbonelli, M. & Hoffer, K. J. Repeatability of automatic measurements by a new Scheimpflug camera combined with Placido topography. J. Cataract Refract. Surg. 37, 1809\u20131816 (2011).","journal-title":"J. Cataract Refract. Surg."},{"key":"57926_CR18","doi-asserted-by":"publisher","first-page":"812","DOI":"10.1016\/j.jcrs.2014.06.043","volume":"41","author":"C Temstet","year":"2015","unstructured":"Temstet, C. et al. Corneal epithelial thickness mapping using Fourier-domain optical coherence tomography for detection of form fruste keratoconus. J. Cataract Refract. Surg. 41, 812\u2013820 (2015).","journal-title":"J. Cataract Refract. Surg."},{"key":"57926_CR19","doi-asserted-by":"publisher","first-page":"456","DOI":"10.1016\/S0886-3350(98)80284-8","volume":"24","author":"JH Krumeich","year":"1998","unstructured":"Krumeich, J. H., Daniel, J. & Kn\u00fclle, A. Live-epikeratophakia for keratoconus. J. Cataract Refract. Surg. 24, 456\u2013463 (1998).","journal-title":"J. Cataract Refract. Surg."},{"issue":"845","key":"57926_CR20","first-page":"847","volume":"93","author":"SD Klyce","year":"2009","unstructured":"Klyce, S. D. Chasing the suspect: keratoconus. Br. J Ophthalmol. 93(845), 847 (2009).","journal-title":"Br. J Ophthalmol."},{"issue":"Suppl 1","key":"57926_CR21","first-page":"5","volume":"86","author":"K N\u00e6ser","year":"2008","unstructured":"N\u00e6ser, K. Assessment and statistics of surgically induced astigmatism. Acta Ophthalmolog. Scand. 86(Suppl 1), 5\u201328 (2008).","journal-title":"Acta Ophthalmolog. Scand."},{"key":"57926_CR22","unstructured":"International Organization for Standardization. Accuracy (Trueness and Precision) of Measurement Methods and Results. Part 1. General Principles and Definitions. Geneva, Switzerland, ISO 5725-1 (1994)."},{"key":"57926_CR23","doi-asserted-by":"publisher","first-page":"744","DOI":"10.1136\/bmj.313.7059.744","volume":"313","author":"JM Bland","year":"1996","unstructured":"Bland, J. M. & Altman, D. G. Statistics notes: measurement error. B.M.J. 313, 744 (1996).","journal-title":"B.M.J."},{"key":"57926_CR24","doi-asserted-by":"publisher","first-page":"661","DOI":"10.1016\/j.ophtha.2007.05.035","volume":"115","author":"DL Budenz","year":"2008","unstructured":"Budenz, D. L., Fredette, M. J., Feuer, W. J. & Anderson, D. R. Reproducibility of peripapillary retinal nerve fiber thickness measurements with stratus OCT in glaucomatous eyes. Ophthalmology. 115, 661\u2013666 (2008).","journal-title":"Ophthalmology."},{"key":"57926_CR25","doi-asserted-by":"publisher","first-page":"30","DOI":"10.1037\/1082-989X.1.1.30","volume":"1","author":"KO McGraw","year":"1996","unstructured":"McGraw, K. O. & Wong, S. P. Forming inferences about some intra-class correlation coefficients. Psychol. Meth. 1, 30\u201346 (1996).","journal-title":"Psychol. Meth."},{"issue":"1","key":"57926_CR26","doi-asserted-by":"publisher","first-page":"307","DOI":"10.1016\/S0140-6736(86)90837-8","volume":"8","author":"JM Bland","year":"1986","unstructured":"Bland, J. M. & Altman, D. G. Statistical methods for assessing agreement between two methods of clinical measurement. Lancet 8(1), 307\u2013310 (1986).","journal-title":"Lancet"},{"key":"57926_CR27","doi-asserted-by":"publisher","first-page":"2598","DOI":"10.1016\/j.jcrs.2015.06.029","volume":"41","author":"C McAlinden","year":"2015","unstructured":"McAlinden, C., Khadka, J. & Pesudovs, K. Precision (repeatability and reproducibility) studies and sample-size calculation. J. Cataract Refract. Surg. 41, 2598\u20132604 (2015).","journal-title":"J. Cataract Refract. Surg."}],"container-title":["Scientific Reports"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.nature.com\/articles\/s41598-020-57926-7.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.nature.com\/articles\/s41598-020-57926-7","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.nature.com\/articles\/s41598-020-57926-7.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2022,12,6]],"date-time":"2022-12-06T01:22:57Z","timestamp":1670289777000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.nature.com\/articles\/s41598-020-57926-7"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2020,1,24]]},"references-count":27,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2020,12]]}},"alternative-id":["57926"],"URL":"https:\/\/doi.org\/10.1038\/s41598-020-57926-7","relation":{},"ISSN":["2045-2322"],"issn-type":[{"value":"2045-2322","type":"electronic"}],"subject":[],"published":{"date-parts":[[2020,1,24]]},"assertion":[{"value":"4 July 2019","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"6 January 2020","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"24 January 2020","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"The authors declare no competing interests.","order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"1124"}}