{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,2,5]],"date-time":"2026-02-05T07:27:02Z","timestamp":1770276422800,"version":"3.49.0"},"reference-count":34,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2020,1,28]],"date-time":"2020-01-28T00:00:00Z","timestamp":1580169600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2020,1,28]],"date-time":"2020-01-28T00:00:00Z","timestamp":1580169600000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"funder":[{"DOI":"10.13039\/501100009738","name":"Anna och Edwin Bergers Stiftelse","doi-asserted-by":"publisher","id":[{"id":"10.13039\/501100009738","id-type":"DOI","asserted-by":"publisher"}]},{"name":"The Swedish Children Heart Association Both funders gave small project grants"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Sci Rep"],"abstract":"<jats:title>Abstract<\/jats:title><jats:p>Clinical evaluation of intracardiac shunts in children is not straightforward. Echocardiography can only diagnose the presence of a shunt but does not estimate the shunt ratio. This can be a critical factor that influences treatment options. In this single-center, prospective, observational, method-comparison study, we validate the ability of a novel monitoring device COstatus to estimate the intracardiac shunt ratio (Qp\/Qs) of pulmonary (Qp) to systemic (Qs) blood flow in young children before and after corrective cardiac surgery. The indicator dilution technology COstatus monitor was compared to two other more invasive reference techniques, perivascular ultrasonic flow probes (placed around the pulmonary truncus and ascending aorta) and the oximetric shunt equation (using arterial and venous blood gases). Our study revealed that the COstatus monitor detected intracardiac shunts with high sensitivity and specificity but there was some underestimation of the shunt ratios compared to the reference techniques.<\/jats:p>","DOI":"10.1038\/s41598-020-58347-2","type":"journal-article","created":{"date-parts":[[2020,1,28]],"date-time":"2020-01-28T11:03:18Z","timestamp":1580209398000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":4,"title":["Estimation of intracardiac shunts in young children with a novel indicator dilution technology"],"prefix":"10.1038","volume":"10","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-3596-3486","authenticated-orcid":false,"given":"Theodor Skuli","family":"Sigurdsson","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Lars","family":"Lindberg","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2020,1,28]]},"reference":[{"key":"58347_CR1","doi-asserted-by":"publisher","first-page":"516","DOI":"10.1136\/adc.77.6.516","volume":"77","author":"SM Tibby","year":"1997","unstructured":"Tibby, S. M., Hatherill, M., Marsh, M. J. & Murdoch, I. A. Clinicians\u2019 abilities to estimate cardiac index in ventilated children and infants. Arch. Dis. Childhood. 77, 516\u2013518 (1997).","journal-title":"Arch. Dis. Childhood."},{"key":"58347_CR2","doi-asserted-by":"publisher","first-page":"568","DOI":"10.1007\/s00134-005-2569-5","volume":"31","author":"JR Egan","year":"2005","unstructured":"Egan, J. R. et al. Clinical assessment of cardiac performance in infants and children following cardiac surgery. Intensive Care Med. 31, 568\u2013573 (2005).","journal-title":"Intensive Care Med."},{"key":"58347_CR3","doi-asserted-by":"crossref","first-page":"560","DOI":"10.1542\/peds.2010-2920","volume":"128","author":"J Lemson","year":"2011","unstructured":"Lemson, J., Nusmeier, A. & van der Hoeven, J. G. Advanced hemodynamic monitoring in critically ill children. Pediatrics. 128, 560\u2013571 (2011).","journal-title":"Pediatrics."},{"key":"58347_CR4","doi-asserted-by":"publisher","first-page":"1019","DOI":"10.1111\/j.1460-9592.2008.02720.x","volume":"18","author":"JJ Skowno","year":"2008","unstructured":"Skowno, J. J. & Broadhead, M. Cardiac output measurement in pediatric anesthesia. Paediatr. Anaesth. 18, 1019\u20131028 (2008).","journal-title":"Paediatr. Anaesth."},{"key":"58347_CR5","doi-asserted-by":"publisher","first-page":"143","DOI":"10.1016\/j.earlhumdev.2010.01.032","volume":"86","author":"WP de Boode","year":"2010","unstructured":"de Boode, W. P. Cardiac output monitoring in newborns. Early Hum. Dev. 86, 143\u2013148 (2010).","journal-title":"Early Hum. Dev."},{"key":"58347_CR6","doi-asserted-by":"publisher","first-page":"513","DOI":"10.1007\/BF01711908","volume":"20","author":"J Shephard","year":"1994","unstructured":"Shephard, J., Brecker, S. & Ewans, T. Bedside assessment of myocardial performance in the critically ill. Intensive Care Med. 20, 513\u2013521 (1994).","journal-title":"Intensive Care Med."},{"key":"58347_CR7","doi-asserted-by":"publisher","first-page":"451","DOI":"10.1093\/bja\/aev356","volume":"116","author":"Y Le Manach","year":"2016","unstructured":"Le Manach, Y. & Collins, G. S. Disagreement between cardiac output measurement devices: which device is the gold standard? Br. J. Anaesth. 116, 451\u2013453 (2016).","journal-title":"Br. J. Anaesth."},{"key":"58347_CR8","doi-asserted-by":"publisher","first-page":"603","DOI":"10.1007\/s10877-015-9757-9","volume":"30","author":"K Suehiro","year":"2016","unstructured":"Suehiro, K. et al. Accuracy and precision of minimally-invasive cardiac output monitoring in children: a systematic review and meta-analysis. J. Clin. Monit. Comput. 30, 603\u2013620 (2016).","journal-title":"J. Clin. Monit. Comput."},{"key":"58347_CR9","doi-asserted-by":"publisher","first-page":"145","DOI":"10.4103\/0974-2069.115259","volume":"6","author":"RJ Stark","year":"2013","unstructured":"Stark, R. J. & Shekerdemian, L. S. Estimating intracardiac and extracardiac shunting in the setting of complex congenital heart disease. Ann. Pediatr. Cardiol. 6, 145\u2013151 (2013).","journal-title":"Ann. Pediatr. Cardiol."},{"key":"58347_CR10","doi-asserted-by":"publisher","first-page":"1220","DOI":"10.1097\/ALN.0b013e3181ee3130","volume":"113","author":"PJ Peyton","year":"2010","unstructured":"Peyton, P. J. & Chong, S. W. Minimally invasive measurement of cardiac output during surgery and critical Care: a meta-analysis of accuracy and precision. Anesthesiology. 113, 1220\u20131235 (2010).","journal-title":"Anesthesiology."},{"key":"58347_CR11","doi-asserted-by":"publisher","first-page":"423","DOI":"10.1097\/01.PCC.0b013e31816c71bc","volume":"9","author":"NM Krivitski","year":"2008","unstructured":"Krivitski, N. M., Kislukhin, V. V. & Thuramalla, N. V. Theory and in vitro validation of a new extracorporeal arteriovenous loop approach for hemodynamic assessment in pediatric and neonatal intensive care unit patients. Pediatr. Crit. Care Med. 9, 423\u2013428 (2008).","journal-title":"Pediatr. Crit. Care Med."},{"key":"58347_CR12","doi-asserted-by":"publisher","first-page":"42","DOI":"10.1097\/PCC.0b013e3182196804","volume":"13","author":"I Crittendon","year":"2012","unstructured":"Crittendon, I., Dreyer, W. J., Decker, J. A. & Kim, J. J. Ultrasound dilution: an accurate means of determining cardiac output in children. Pediatr. Crit. Care Med. 13, 42\u201346 (2012).","journal-title":"Pediatr. Crit. Care Med."},{"key":"58347_CR13","doi-asserted-by":"publisher","first-page":"870","DOI":"10.1093\/bja\/aes297","volume":"109","author":"SL Vrancken","year":"2012","unstructured":"Vrancken, S. L. et al. Influence of lung injury on cardiac output measurement using transpulmonary ultrasound dilution: a validation study in neonatal lambs. Br. J. Anaesth. 109, 870\u2013878 (2012).","journal-title":"Br. J. Anaesth."},{"key":"58347_CR14","doi-asserted-by":"publisher","first-page":"139","DOI":"10.1097\/PCC.0000000000000053","volume":"15","author":"L Lindberg","year":"2014","unstructured":"Lindberg, L., Johansson, S. & Perez-de-Sa, V. Validation of an ultrasound dilution technology for cardiac output measurement and shunt detection in infants and children. Pediatr. Crit. Care Med. 15, 139\u2013147 (2014).","journal-title":"Pediatr. Crit. Care Med."},{"key":"58347_CR15","doi-asserted-by":"publisher","first-page":"407","DOI":"10.1007\/s10877-014-9618-y","volume":"29","author":"R Saxena","year":"2015","unstructured":"Saxena, R. et al. Accuracy of the transpulmonary ultrasound dilution method for detection of small anatomic shunts. J. Clin. Monit. Comput. 29, 407\u2013414 (2015).","journal-title":"J. Clin. Monit. Comput."},{"key":"58347_CR16","doi-asserted-by":"publisher","first-page":"409","DOI":"10.1093\/bja\/aer401","volume":"108","author":"SL Vrancken","year":"2012","unstructured":"Vrancken, S. L. et al. Cardiac output measurement with transpulmonary ultrasound dilution is feasible in the presence of a left-to-right shunt: a validation study in lambs. Br. J. Anaesth. 108, 409\u2013416 (2012).","journal-title":"Br. J. Anaesth."},{"key":"58347_CR17","doi-asserted-by":"publisher","first-page":"643","DOI":"10.1007\/s10877-014-9647-6","volume":"29","author":"SL Vrancken","year":"2015","unstructured":"Vrancken, S. L. et al. Hemodynamic volumetry using transpulmonary ultrasound dilution (TPUD) technology in a neonatal animal model. J. Clin. Monit. Comput. 29, 643\u2013652 (2015).","journal-title":"J. Clin. Monit. Comput."},{"key":"58347_CR18","unstructured":"Boehne, M. et al. Novel ultrasound dilution technique detects left-to-right shunts with high accuracy in children. The 3rd Congress of European Academy of Paediatric Societies (EAPS), Copenhagen, Denmark; Poster 1680 (2010)."},{"issue":"Supplement","key":"58347_CR19","first-page":"P61","volume":"39","author":"A Shia","year":"2011","unstructured":"Shia, A. et al. Saline ultrasound dilution technique as a minimally invasive way to detect intracardiac shunt in an atrial septal defect model. Crit. Care Med. 39(Supplement), P61 (2011).","journal-title":"Crit. Care Med."},{"key":"58347_CR20","doi-asserted-by":"publisher","first-page":"772","DOI":"10.1161\/01.CIR.32.5.772","volume":"32","author":"L Krovetz","year":"1965","unstructured":"Krovetz, L. & Gessner, I. A new method utilizing indicator dilution technics for estimation of left-to-right shunts in infants. Circulation. 32, 772\u2013777 (1965).","journal-title":"Circulation."},{"key":"58347_CR21","doi-asserted-by":"publisher","first-page":"703","DOI":"10.1111\/j.0954-6820.1961.tb00289.x","volume":"170","author":"G Mook","year":"1961","unstructured":"Mook, G. & Zijlstra, W. Quantitative evaluation of intracardiac shunt from arterial dye dilution curves. Demonstration of very small shunts. Acta Med. Scand. 170, 703\u2013715 (1961).","journal-title":"Acta Med. Scand."},{"key":"58347_CR22","doi-asserted-by":"publisher","first-page":"212","DOI":"10.1161\/01.CIR.14.2.212","volume":"14","author":"P Hetzl","year":"1956","unstructured":"Hetzl, P., Swan, H. & Wood, E. Quantitative estimation by indicator dilution techniques of the contribution of blood from each lung to the left-to-right shunt in atrial septal defect. Circulation. 14, 212\u2013220 (1956).","journal-title":"Circulation."},{"key":"58347_CR23","doi-asserted-by":"publisher","first-page":"400","DOI":"10.1161\/01.RES.4.4.400","volume":"4","author":"A Ramirez de Arellano","year":"1956","unstructured":"Ramirez de Arellano, A., Hetzel, P. & Wood, E. Measurement of pulmonary blood flow using the indicator dilution techniques in patients with a central arteriovenous shunt. Circ. Res. 4, 400\u2013405 (1956).","journal-title":"Circ. Res."},{"key":"58347_CR24","doi-asserted-by":"publisher","first-page":"199","DOI":"10.1016\/S0002-9149(00)80081-8","volume":"75","author":"WC Daniel","year":"1995","unstructured":"Daniel, W. C. et al. Oximetric versus indicator dilution techniques for quantitating intracardiac left-to-right shunting in adults. Am. J. Cardiology. 75, 199\u2013200 (1995).","journal-title":"Am. J. Cardiology."},{"key":"58347_CR25","doi-asserted-by":"publisher","first-page":"712","DOI":"10.1097\/ALN.0000000000002582","volume":"130","author":"TS Sigurdsson","year":"2019","unstructured":"Sigurdsson, T. S., Aronsson, A. & Lindberg, L. Extracorporeal arteriovenous ultrasound measurement of cardiac output in small children. Anesthesiology. 130, 712\u2013718 (2019).","journal-title":"Anesthesiology."},{"key":"58347_CR26","doi-asserted-by":"publisher","first-page":"671","DOI":"10.1097\/ALN.0000000000002673","volume":"130","author":"CT Trieu","year":"2019","unstructured":"Trieu, C. T., Williams, T. M., Cannesson, M. & Marijic, J. Babies and children at last: Pediatric cardiac output monitoring in the twenty-first century. Anesthesiology. 130, 671\u2013673 (2019).","journal-title":"Anesthesiology."},{"key":"58347_CR27","doi-asserted-by":"publisher","first-page":"469","DOI":"10.1093\/bja\/aet382","volume":"112","author":"M Boehne","year":"2014","unstructured":"Boehne, M. et al. Determination of cardiac output by ultrasound dilution technique in infants and children: a validation study against direct Fick principle. Br. J. Anaesth. 112, 469\u2013476 (2014).","journal-title":"Br. J. Anaesth."},{"key":"58347_CR28","doi-asserted-by":"publisher","first-page":"159","DOI":"10.1113\/jphysiol.1897.sp000684","volume":"22","author":"G Stewart","year":"1897","unstructured":"Stewart, G. Researches on the circulation time and on the influences which affect it. J. Physiology. 22, 159\u2013183 (1897).","journal-title":"J. Physiology."},{"key":"58347_CR29","doi-asserted-by":"publisher","first-page":"534","DOI":"10.1152\/ajplegacy.1932.99.3.534","volume":"99","author":"WF Hamilton","year":"1932","unstructured":"Hamilton, W. F., Moore, J. W., Kinsman, J. M. & Spurling, R. G. Studies on the circulation. Am. J. Physiology. 99, 534\u2013551 (1932).","journal-title":"Am. J. Physiology."},{"key":"58347_CR30","doi-asserted-by":"publisher","first-page":"799","DOI":"10.1213\/ANE.0b013e3181cc885a","volume":"110","author":"DA Reuter","year":"2010","unstructured":"Reuter, D. A. et al. Cardiac output monitoring using indicator-dilution techniques: basics, limits, and perspectives. Anesth. Analg. 110, 799\u2013811 (2010).","journal-title":"Anesth. Analg."},{"key":"58347_CR31","doi-asserted-by":"publisher","first-page":"M671","DOI":"10.1097\/00002480-199609000-00072","volume":"42","author":"DA Dean","year":"1996","unstructured":"Dean, D. A., Jia, C. X. & Cabreriza, S. E. Validation study of a new transit time ultrasonic flow probe for continuous great vessel measurements. ASAIO J. 42, M671\u2013676 (1996).","journal-title":"ASAIO J."},{"key":"58347_CR32","doi-asserted-by":"publisher","first-page":"563","DOI":"10.1053\/j.jvca.2004.07.005","volume":"18","author":"M Botero","year":"2004","unstructured":"Botero, M. et al. Measurement of cardiac output before and after cardiopulmonary bypass: Comparison among aortic transit-time ultrasound, thermodilution, and noninvasive partial CO2 rebreathing. J. Cardiothorac. Vasc. Anesthesia. 18, 563\u2013572 (2004).","journal-title":"J. Cardiothorac. Vasc. Anesthesia."},{"key":"58347_CR33","doi-asserted-by":"publisher","first-page":"307","DOI":"10.1016\/S0140-6736(86)90837-8","volume":"8","author":"JM Bland","year":"1986","unstructured":"Bland, J. M. & Altman, D. G. Statistical methods for assessing agreement between two methods of clinical measurement. Lancet. 8, 307\u2013310 (1986).","journal-title":"Lancet."},{"key":"58347_CR34","doi-asserted-by":"publisher","first-page":"630","DOI":"10.1177\/0962280211402548","volume":"22","author":"GY Zou","year":"2013","unstructured":"Zou, G. Y. Confidence interval estimation for the Bland-Altman limits of agreement with multiple observations per individual. Stat. Methods Med. Res. 22, 630\u2013642 (2013).","journal-title":"Stat. Methods Med. Res."}],"container-title":["Scientific Reports"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.nature.com\/articles\/s41598-020-58347-2.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.nature.com\/articles\/s41598-020-58347-2","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.nature.com\/articles\/s41598-020-58347-2.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2022,12,6]],"date-time":"2022-12-06T06:18:23Z","timestamp":1670307503000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.nature.com\/articles\/s41598-020-58347-2"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2020,1,28]]},"references-count":34,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2020,12]]}},"alternative-id":["58347"],"URL":"https:\/\/doi.org\/10.1038\/s41598-020-58347-2","relation":{},"ISSN":["2045-2322"],"issn-type":[{"value":"2045-2322","type":"electronic"}],"subject":[],"published":{"date-parts":[[2020,1,28]]},"assertion":[{"value":"31 May 2019","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"14 January 2020","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"28 January 2020","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"The authors declare no competing interests.","order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"1337"}}